• Title/Summary/Keyword: 금속 인공물

Search Result 77, Processing Time 0.027 seconds

Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.

인공관절의 수명 향상을 위해 PIII&D (Plasma Immersion Ion Implantation & Deposition) 기술로 제조된 인공관절용 NbN 박막의 마모 특성 평가

  • Park, Won-Ung;Jeon, Jun-Hong;Mun, Seon-U;Choe, Jin-Yeong;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.189-189
    • /
    • 2011
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등으로 인하여 발생하는 관절의 손상 부위를 대체하기 위해 고안된 관절의 인공 대용물이다. 인공 관절 중 인공 고관절의 경우 관절 운동을 하는 라이너(Liner)와 헤드(Head) 부분이 인공관절의 수명을 결정하게 되는데, 헤드 부분에 메탈소재와 라이너 부분에 고분자 소재를 사용하는 MOP (metal on polymer) 구조의 인공관절은 충격흡수의 장점이 있는 반면 wear debris에 의한 골용해로 인하여 관절이 느슨해지는 문제점이 발생하여 재 시술의 주요 원인이 되고 있다. 또한 메탈 헤드의 마모로 인한 금속이온의 용출은 세포 독성의 문제를 야기하여 인공관절의 수명을 낮추는 또 하나의 요인이 되고 있다. 따라서 인공관절의 수명을 늘리기 위해 DLC, ZrO, TiN 등의 높은 경도 값을 갖는 박막을 금속 헤드 위에 증착하여 상대재인 인공관절용 고분자 소재의 마모량을 줄이고자 하는 연구가 활발하게 진행 되고 있다. 본 연구에서는 PIII&D (Plasma Immersion Ion Implantation & Deposition)공정을 이용하여 Co-Cr-Mo 합금 소재 niobium nitride (NbN) 박막을 증착하여 상대제인 UHMWPE (ultra high molecular polyethylene)의 마모를 줄이고자 하는 연구를 진행하였다. 마모량을 감소시키기 위하여, 박막 증착전에 질소를 이온주입하는 pre-ion implantation 공정을 도입하였으며, 또한 Co-Cr 합금과 NbN박막 사이의 접착력을 증가시키기 위하여 박막의 증착 초기에 이온주입과 증착을 동시에 수행하는 dynamic ion mixing공정을 수행하였다. NbN 박막의 특성을 평가하기 위해 XRD, XPS, AFM 등의 분석을 수행하였으며, 상대재인 초고분자량 폴리에틸렌의 마모량을 측정하기 위해 Pin-on-disk tester를 이용하여 마모 실험을 진행하였다. 마모 실험 결과, pre-ion implantation 공정을 도입한 경우 현재 상용화 되어있는 Co-Cr 합금에 비하여 마모량을 2배 이상 감소시키는 것을 확인 할 수 있었으며, dynamic ion mixing 공정을 도입한 경우 장시간의 마모 시험에 대한 마모 특성이 향상 되는 것을 확인 할 수 있었다.

  • PDF

The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT (PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰)

  • Park, Min Soo;Ham, Jun Cheol;Cho, Yong In;Kang, Chun Goo;Park, Hoon-Hee;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.35-43
    • /
    • 2012
  • Purpose : PET/CT performed CT-based attenuation correction generates the beam hardening artifact by metallic implant. The attenuation correction causes over or underestimate of the area adjacent to metallic hip prosthetic material and change of $^{18}F$-FDG uptake. Also, the image quality and the diagnosability on genitourinary disease are reduced. Therefore, this study will evaluate the usefulness of MAR (Metal Artifact Reduction) algorithm method to improve the image quality on PET/CT. Materials and Methods : PET/CT was performed by fixing hip prosthesis in SPECT/PET phantom. In PET images with and Without MAR algorithm, the Bright streak, Dark streak, Metal region and Background area that appeared on CT were confirmed, and the change of each SUV (standardized uptake value) was analyzed. Also, in 15 patients who underwent total hip arthroplasty, each MAR algorithm and Without MAR algorithm and non attenuation correction was evaluated. Results : In PET image Without MAR algorithm, SUV of Bright streak region was $0.98{\pm}0.48$ g/ml; Dark streak region was $0.88{\pm}0.02$ g/ml; Metal region was $0.24{\pm}0.16$ g/ml, Background area was $0.91{\pm}0.18$ g/ml. In SUV of PET image with MAR algorithm, Bright streak region was $0.88{\pm}0.49$ g/ml, Dark streak region was $0.63{\pm}0.21$ g/ml, Metal region was $0.06{\pm}0.07$ g/ml, Background was $0.90{\pm}0.02$ g/ml. SUV generally decreased when applying MAR algorithm. In PET image Without MAR algorithm, SUVs of Bright region were higher than those measured in the Background, and it was false positive uptake. But, in PET image with MAR algorithm, SUVs of Bright region were similar to the Background, and false positive uptake disappeared. Conclusion : MAR algorithm could reduce an increase of $^{18}F$-FDG uptake due to attenuation correction in the hip surrounding tissue. However, decrease of SUV in Dark streak region should be considered in the future. Therefore, this study propose that the diagnostic accuracy can be improved in genitourinary diseases adjacent to metallic hip prosthesis, if provided PET images with and Without MAR algorithm, and non attenuation correction images at the same time.

  • PDF

Design and Fabrication of Composite Sandwich Payload Platform and Strut Tubes for Satellite Main Body Structures (인공위성 본체 복합재료 샌드위치 플랫폼 및 튜브 스트럿 구조물의 설계 및 제작)

  • Roh, Hui-Seok;Choi, Heung-Seop;Ha, Jae-Seon;Son, Won-Gi;Kim, Cheol;Lee, Ju-Hun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.228-232
    • /
    • 2002
  • 본 연구에서는 다목적 실용위성 2호기에 적용된 금속 구조물 중 알루미늄 샌드위치 패널 구조인 탑재체 플랫폼과 튜브 스트럿(tube strut) 구조에 복합재료 응용기술을 적용하였다. 복합재료 구조로의 대체 설계에서도 관성하중 및 음향진동등과 같은 극심한 발사환경과 더불어 운용하게 될 우주 열환경을 고려하였다. 연구의 목적은 금속소재보다 비강도, 비강성이 우수한 복합재료를 위성 구조물에 사용함으로써 무게를 경량화함에 있다.

  • PDF

Reduction of Metal Artifact by Using VAT-SEMAC in MRI (VAT-SEMAC을 이용한 보철물에 의한 허상 감소)

  • Kim, Hyung-Tae;Lim, Jong-Nam;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.227-232
    • /
    • 2019
  • MRI examination for patients with metal objects has in poor image quality. Metallic implants can result in poor image because magnetic susceptibility causes signal loss and distortion and makes poor imaging, which is called magnetic susceptibility artifact or metal artifact. There are several approaches to reduce metal artifacts. In this study, we study the reduction of metal artifact by VAT and SEMAC techniques. A metal implant used for orthopedic surgery was attached to the phatom and the distortion caused by the artifact was measured under T1WI and T2WI protocols. Several techniques of VAT only and VAT and SEMAC for the reduction of metal artifact were compared. The metal artifact showed a reduction of at least 8% to a maximum of 26% in the VAT-SEMAC. The VAT-SEMAC technique can be applied to patients with orthopedic implants to improve image quality. If scan time and image quality are simultaneously considered in VAT-SEMAC technique, metal artifact will be reduced in clinical practice.

Distribution of TOC and metals in the surface sediments of the Lake Shihwa (시화호 표층 퇴적물의 유기탄소와 금속의 분포)

  • Kim, Kyung-Tae;Kim, Eun-Soo;Cho, Sung-Rok;Park, Jun-Kun;Kim, Jong-Kun;Lee, Jeong-Moo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2008.05a
    • /
    • pp.159-164
    • /
    • 2008
  • In order to understand the spatio-temporal distribution of geochemical parametrs in surface sediments of the artificial Lake Shihwa in the vicinity of Kyunggi Hay in Korea, surface sediments were sampled at 14 sites in July 2007 and analyzed by CHN analyzer and ICP/MS. Metal concentrations in the sediments tended to be decreasing from the head to the mouth of the Lake Shihwa because of extreme pollutant discharge from various kinds of anthropogenic sources such as the Banweol and Shihwa Industrial Complex and cities. With the deposition of fine-grained sediments, high metal concentrations were also observed in the central part of lake. Although various programs(improvement of wastewater collection and treatment system, sea-lake water exchange etc) to improve the environmental conditions around the Lake Shihwa after dike construction were carried out, it was not dear to reach a good environmental quality. Therefore, further environmental programs should be conducted continuously for environmental improvement.

  • PDF

첨단과학기술현장 - 조직공학의 오늘과 내일

  • Hyeon, Won-Bok
    • The Science & Technology
    • /
    • v.32 no.7 s.362
    • /
    • pp.71-75
    • /
    • 1999
  • 몇해 전만 해도 대부분의 과학자들은 신장이나 심장과 같은 인간의 조직은 장기제공자로부터 직접 이식을 받거나 또는 플라스틱, 금속 그리고 컴퓨터칩으로 만든 완전 인공부붚므오만 대체할 수 있다고 믿고 있었다. 또 많은 사람들은 생세포와 인공폴리머의 혼성물인 바이오인공장기는 결코 제작할 수 없으며 이식용 인간장기의 부족을 충당할 수 있는 유일한 길은 동물의 장기를 사용하는 것 뿐이라고 생각했다. 그러나 앞으로는 조직공학이라는 새로운 생명과학기술의 진보로 간질환 환자가 자기의 간세포와 플라스틱섬유로 만든 '네오(신)장기' 이식으로 병을 치유할 수 있고 인슐린에 의존하던 당뇨병환자가 대체용 췌장 덕에 인슐린주사를 자주 맞을 필요가 없게 되며 신장병환자는 누구든지 자기의 세포로 키운 새로운 신장을 이식할 수 있게 되어 신장투석기의 모습이 세상에서 사라지게 되는 시대를 기대할 수 있게 되었다. 또 우리 몸을 형성하는 육체의 '부품'을 사고 팔 수 있는 시대가 뜻밖에도 빨리 다가올지 모른다고 생각하고 있는 과학자들도 있다.

  • PDF

Osteolysis-Related Bioabsorbable Suture Anchor Fixation in a Medial Collateral Ligament Avulsion Fracture during Total Knee Arthroplasty (슬관절 인공관절 치환술 중 발생한 내측 측부 인대 견열 골절에 대해 생흡수성 봉합 나사못을 이용한 고정 후 발생한 골용해)

  • Huh, Jung-Wook;Park, Man-Jun;Hong, Seong-Hwak;Park, Joon-Hyung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.545-549
    • /
    • 2020
  • Although rare, the treatment options for a medial collateral avulsion fracture during total knee arthroplasty (TKA) range from conservative management using a cast and orthosis to internal fixation using metal screws. Bioabsorbable suture anchors have been used to replace metal fixators with distinct advantages, such as biocompatibility, radiolucency, and unnecessary second removal surgery, but complications, such as osteolysis, have been reported. This paper reports a potential risk of an extensive osteolysis-related suture anchor fixation of a medial collateral ligament (MCL) avulsion fracture during TKA in conjunction with a literature review.

Behavior Analysis of the Treated Femur and Design of Composite Hip Prosthesis (대퇴부 거동 해석 및 복합재료 보철물 설계)

  • 임종완;하성규
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.119-130
    • /
    • 2002
  • The nonlinear finite element program has been developed to analyze the design performance of an artificial hip prosthesis and long term behavior of a treated femur with stems made of composite material after cementless total hip arthroplasty(THA). The authors developed the three dimentional FEM models of femoral bone with designed composite stem which was taken with elliptic cross section of 816 brick elements under hip contact load and muscle farce in simulating single leg stand. Using the program, density changes, stress distributions and micromotions of the material femoral bone were evaluated by changing fiber orientation of stems for selected manufacturing method such as plate cut and bend mold. The results showed that the composite materials such as AS4/PEEK and T300/976 gave less bone resorption than the metallic material such as cobalt chrome alloy, titanium alloy and stainless steal. It was found that increasing the long term stability of the prosthesis in the femur could be obtained by selecting the appropriate ply orientation and stacking sequence of composite.

Fabrication of surveyed crown and repairing the artificial teeth for existing removable partial denture using digital technology: a case report (디지털 방식을 이용한 기존 국소의치 맞춤 보철 제작과 심미적인 인공치 수리 증례)

  • Ina Kim;Eunji Oh;Sang-Won Park;Hyun-Pil Lim;Kwi-dug Yun;Chan Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.82-90
    • /
    • 2024
  • It often happens that a removable partial denture needs to be repaired due to tissue changes in the remaining alveolar ridge, fracture of the denture, or fracture of the abutment tooth. There are several advantages to retrofitting a customized surveyed crown under the existing RPD. Retrofitting a crown to the RPD decreases the economic burden to the patient and avoids the need for several appointments to fabricate a new RPD. It is difficult for artificial teeth used to repair dentures due to fractured natural teeth to have a shape similar to that of natural teeth, and to repair aesthetic artificial teeth, it is necessary to manufacture customized artificial teeth similar to the shape of each patient's teeth. Recently, CAD/CAM technology has been used to fabricate customized prosthetics on existing RPD to achieve high retention and fitness accuracy, and by manufacturing customized artificial teeth, more aesthetic and harmonious artificial tooth repair is possible. This is a case in which a denture was repaired using a digital method to fabricate a customized prosthesis on an existing partial denture and customized artificial teeth that mirrored the adjacent dentition, saving time and cost, simplifying the process, and achieving aesthetically and functionally satisfactory results.