• Title/Summary/Keyword: 금속 용사 박막

Search Result 5, Processing Time 0.019 seconds

An Evaluation of Physical Properties of Metal Sprayed Coating According to Concrete Surface Treatment Methods (콘크리트 표면 처리 방법에 따른 금속 용사 피막의 물리적 특성 평가)

  • Jang, Jong-Min;Jang, Hyun O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.67-68
    • /
    • 2021
  • Social infrastructure facilities can be destroyed instantly when exposed to EMP (ElectroMagnetic Pulse), causing social chaos. However, concrete structures with low electrical conductivity cannot expect EMP shielding effect. Therefore, in this study, a metal sprayed thin film showing excellent EMP shielding performance was applied to a concrete structure to evaluate the metal spray welding efficiency and adhesion performance of the thin film according to the concrete surface treatment method. As a result according to the concrete surface treatment method, It was confirmed that the use of a roughening agent that generates physical irregularities in order to improve the welding efficiency and adhesion performance increases the physical performance of the concrete and metal sprayed thin film.

  • PDF

A Study on the Electromagnetic Pulse Shielding Effect of Concrete Wall Sprayed with Cu-based Metal (Cu계 금속을 용사한 콘크리트 벽체의 전자파 차폐 성능에 관한 연구)

  • Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.18-19
    • /
    • 2020
  • The ElectroMagnetic Pulse (EMP) destroys social infrastructure at once and causes social chaos. However, currently major infrastructures are constructed of concrete that does not have electromagnetic shielding performance. In this study, using the arc metal spraying method is used to evaluate the shielding performance and construction performance of concrete. The electro-magnetic shielding effect is measured by fabricating a shielding room with reference to MIL-STD-188-125, and the construction performance is evaluated by measuring the adhesion strength of thin metal sprayed film-concrete. As a result of the study, when the metal spraying method is applied, the shielding effect is higher than that of the special electro-magnetic shielding concrete, and it is considered to be more economical than the existing metal plate (3~5 mm).

  • PDF

A Study on the Electrical Conductivity and Electromagnetic Pulse Shielding Characteristics of Metal Sprayed Coating (금속 용사 피막의 전기전도도 및 전자파 차폐 특성에 관한 연구)

  • Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.8-9
    • /
    • 2020
  • In this study, the electrical conductivity and shielding effect were evaluated according to the type of metal and the thickness of Metal sprayed coating. The metals used for the test are Cu, Cu-Ni and Cu-Zn, and the thicknesses were 100, 200, 500 um. Each metal sprayed coating was evaluated for electrical conductivity and electromagnetic shielding effect. When the thickness was 200 ㎛ or more, shielding effect 80 dB or more was satisfied at 1 GHz. However, in the case of Cu-Ni, there is little electrical conductivity at a thickness of 100 um or less due to the generated voids, and electromagnetic wave shielding performance cannot be expected. Therefore, To ensure electromagnetic shielding effect of structures, it is considered that the minimum thickness of metal spraying coating should be 200 um.

  • PDF

Evaluation of physical properties of Zn-Al metal spray coating according to concrete surface and treatment method (콘크리트 표면 처리 방법 및 용사면에 따른 Zn-Al 금속 용사 피막의 물리적 특성 평가)

  • Jang, Jong-Min;Yang, Hyun Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.59-60
    • /
    • 2022
  • When a metal sprayed film of several hundred ㎛ on the concrete surface is possible to 80 dB of shielding effect electromagnetic waves (ElectroMagnetic Pulse, EMP). Therefore, in this study, as a way to secure EMP shielding performance by applying a metal spray coating showing excellent EMP shielding performance to a concrete structure, the metal spray welding efficiency and thin film adhesion performance according to the concrete spray direction and surface treatment method were evaluated. Metal sprayed efficieny according to the metal spraying direction and method was confirmed that the difference was insignificant by applying the roughening agent. However, the method of strengthening the concrete surface and applying the sealing agent show maximum adhesion strength of 3.98 MPa compared to other methods, and it is judged that this method can be utilized for the metal spraying method for concrete EMP shielding.

  • PDF

Effects of Metalized Al-2%Zn Layer on the Corrosion Behavior of Al 5083 Alloy (Al 5083 합금의 부식거동에 미치는 Al-2%Zn 용사 코팅층의 영향)

  • 김용철;김영근;이성민;고영태
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.2-2
    • /
    • 1999
  • 금속재료의 표면 특성을 높이기 위해서 여러 표면처리 방법들이 사용되어져 오고 있다. 그 중 용사법에 의한 코팅방법이 최근의 현저한 기술적인 진보와 새로운 용사재료의 개발 등에 의해 여러 분야에 널리 응흉되고 있다. 일반적으로 이 용사법에 의한 코팅층은 다리, 선박 등의 대형 구조물에 대한 내식성 향상뿐만 아니라 자동차 및 항공기 부품, 핵 반응기 등의 코팅부에 널리 이용되고 였다. 특히 해수분위기에서 주로 사용되는 설비의 내식성을 향상시킬 목적으로 사용되 는 알루마늄 및 아연 합금의 용사 코팅층은 대부분의 경우 건조한 분위기보다는 수분이 많은 수용액 환경 하에서 사용되므로, 사용 환경 중에서 용사피막의 내식성을 조사하는 연구가 요구되고 있다. 사용되는 환경하에서의 침지시험에 의한 방법도 중요하지만, 가속화된 전기화학측정에 의한 방법 또한 이용된다. 열용사법에 의한 코팅층의 전기화학적 특성을 알아보기 위해서 3.5 % NaCI 수용액 내에서 AI 5 5083 모재와 Al-2%Zn 합금의 용사 코팅층 각각에 대한, 그리고 AI 5083 모재 위 AI-2%Zn 용사층이 코팅된 경우에 대한 분극거동과 침지시간에 따른 부식전위 및 분극저항성의 특성변화, 표면의 임피던스특성 변화 등을 측정하였다. 이 결과 모재에 대한 코팅층의 희생양극성올 판단할 수 있고, 모재/코팅 사스템의 분극거동은 혼성전위이론(mixed-potential theory)에 의해 결정되었다. 용사 코팅층이 박리되어 모재가 일부 드러난 경우를 모사한 시험편올 제작하고, 시험편 표면의 각 위치에 따라 부식전위 분포를 측정하였다. 그리고 측정 데이터를 기초로 표면의 상태변화를 모사하여 용사코팅에 의한 표면에서의 방식전위분포를 시율레이션하였다. 이와 같은 표면에서의 방식전위분포 해석을 통하여, 코팅층의 희생양극성에 의한 모재의 방식범위를 판단할 수 있다.의 비저 항을 갖는 철 박막에서도 99.9% 순도의 철을 타켓으로 하여 증착된 막은 일반 저탄소 강을 타켓으로 하여 증착된 막보다 훨씬 낮은 부식속도를 보였다.TEX>$He/O_2/Ar/N_2$의 gas를 사용 한 atmospheric pressure plasma cleaning 과 $Ar/O_2$의 gas를 사용한 ICP cleaning에서 이 차전자방출계수(SEEC)가 약 1.5~2.5배 증가된 것을 알 수 있었다. 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응$\lrcorne