• Title/Summary/Keyword: 금속 용사

Search Result 93, Processing Time 0.031 seconds

An Experimental Study on the Permeability Evaluation of Metal Spray System by Concrete Surface Treatment (콘크리트 표면처리방법에 따른 금속용사 피막의 투수성 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.34-35
    • /
    • 2015
  • Recently, introduction of Advanced water treatment facilities has been increasing due to serious domestic water pollution. Ozone is a strong oxidizing materials in the advanced water treatment facilities. However, due to such a strong oxidation, Ozone eroded waterproofing/corrosion on the concrete surface and caused performance degradation. Therefore, in this study, permeability experiment of metal spraying system by concrete surface treatment was conducted.

  • PDF

An Experimental Study on the Permeability Evaluation of Metal Spray System by Metal Spray Coating Surface Treatment (콘크리트 표면처리방법에 따른 금속용사 피막의 투수성 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.50-51
    • /
    • 2016
  • Ozone is a strong oxidizing materials in the advanced water treatment facilities. However, due to such a strong oxidation, Ozone eroded waterproofing/corrosion on the concrete surface and caused performance degradation. Therefore, in this study, permeability experiment of metal spraying system by concrete surface treatment was conducted.

  • PDF

Study on the Development of Finishing Design Methods for Building Structures Using the Metal Films (금속피막에 의한 건축 마감 의장 기법 개발에 관한 연구)

  • Lim, Ji-Taek;Jung, Hwa-Rang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.183-189
    • /
    • 2018
  • In this study, the bond strength between concrete and metal films was investigate according to changing water content ratio of substrate concrete by pull-out test in order to develop the new finishing design methods for building structures using the metal films. The following conclusions were obtained as a result of the studies. It was find that the colour of metal did not change before and after the metal spraying. Also, the water content ratio of substrate concrete must be controlled under 10% weight to confirm the standard bond strength of finishing material to concrete. 2.5 MPa. To enhance the bond strength between concrete and metal films, it is very effective to strengthen the concrete surface using the agent which strengthen the concrete surface and seal the pore of metal film by the sealing agents. Therefore, the control of concrete surface treatment and water content ratio are necessary to secure the bond strength of metal films.

Characterization of Modified Surface Manufactured by PTA(Plasma Transferred Arc) Spray (PTA 용사에 의해 제조된 표면개질부의 특성에 관한 연구)

  • Ji Jung-Hun;Yoo Yeon-Gon;Kim Gwang-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.92-95
    • /
    • 2004
  • 플라즈마 트랜스퍼드 아크(PTA) 용사는 플라즈마 아크 용접 장치에 선형의 용접봉을 이용하는 대신 분말 형태의 용접재를 주입하여 주로 마모나 부식에 노출되는 금속의 표면에 적용하여 금속 표면의 내식 내마모 특성을 향상시키는 기술이다. 본 논문에서는 용사전류가 표면개질부에 미치는 기하학적 형상 및 미세조직에 미치는 영향에 대하여 알아보았다. 낮은 전류에서는 접합이 이루어지지 않았고 높은 전류에서는 모재로 희석되어 들어가는 현상을 보였다.

  • PDF

An experimental study on the application of Cathodic Protection method applying Zn-Al metal spray on the RC structure (Zn-Al 금속용사 전기방식 공법의 콘크리트 구조물 적용성에 관한 실험적 연구)

  • Han, Man-Hae;Lee, Han-Seung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.429-432
    • /
    • 2008
  • Cathodic Protection Method was introduced as a corrosion protection method of metals under the ground or sea. Since 1970, it was applied to corrosion protection method of reinforced concrete structures. After 1990, this method has been used around the world, and its usability was proved. But this method has some problems on the aspect of construction and economy. In order to solve these problems, Cathodic Protection Method by using high durable metal spray was developed. First, the specimen was covered with anodic materials (Zn, Al) by using metal spray. And a performance of corrosion protection was confirmed by measuring corrosion current of specimen. Through the result of experiment, it is possible to know that Cathodic Protection Method by using high metal spray is good to protect to corrosion on reinforced concrete structures.

  • PDF

Study on Metal Microfilter Coated with Ceramics by Using Plasma Thermal Spray Method (플라즈마 용사를 이용한 복합세라믹 미세필터 연구)

  • Song, In-Gyu;Lee, Young-Min;Shin, Hyun-Myung;Choi, Hae-Woon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1035-1040
    • /
    • 2011
  • This research was performed on a microfilter made of a hybrid material (ceramic + metal) that was coated with ceramics on the metal-filter surface by using the thermal spray method. The ceramic powders used were $Al_2O_3+40TiO_2$ powder with a particle size of $20{\mu}m$ and $Al_2O_3$ (98%+)powder with a particle size of $45{\mu}m$. The metal filters were filter-grade $20{\mu}m$, $30{\mu}m$, and $50{\mu}m$ sintered metal powder filters (SIKA-R 20 IS, 30 IS, 50 IS; Sinter Metals Filters) and filter-grade $75{\mu}m$ sintered mesh filter with five layers. Ceramic-coated filters that were coated using the thermal spray method had a great influence on powder material, particle size, and coating thickness. However, these filters showed a fine performance when used as micro-filters.

An Evaluation of Slip Coefficient in High Strength Bolt Joint using Zn/Al Metal Spray Corrosion Resistance Method (Zn/Al 금속용사 방식공법을 적용한 고력볼트 접합부의 미끄럼계수 평가)

  • Kim, Tae-Soo;Lee, Han-Seung;Tae, Sung-Ho;Ahn, Hyun-Jin;Oh, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.114-122
    • /
    • 2007
  • In high strength bolted joints, the corrosion of base material causes the reduction of slip resistance of the joints. In this study, tensile tests on slip-critical joints utilizing Zn/Al metal spraying corrosion resistance method were carried out in order to prevent the corrosion and meet the required mechanical characteristics of joints. In addition, slip coefficient and surface roughness were calculated. The key parameters were surface finishing condition and thickness of coating with the identical geometry in all specimens. From the results, it is found that the slip coefficient of the joints with coated finish after sand blast treatment as well as those of non-coated joints with only sand blast treatment were similar or superior to 0.45, which is a specification criteria of slip coefficient in friction-typed joints.

Effect of spray parameters on cavitation erosion behavior of HVOF coating (캐비테이션-에로젼 특성에 미치는 HVOF 용사조건의 영향)

  • Byeon, Eung-Seon;Yu, In-Jun;Lee, Gyu-Hwan;Park, Yul-Min
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.115-115
    • /
    • 2009
  • 캐비테이션-에로젼은 침식부식과 유사한 형태의 침식에 의한 손상이다. 즉, 고속의 애체흐름에 노출된 금속 표면을 따라 압력변화에 의해서 생성된 기포들이 파괴되는 것과 관련하여 일어나는 표면손상의 한 형태이다. 본 연구에서는 캐비테이션-에로젼 손상을 억제하기 위하여 WC 서멧을 HVOF 용사하였으며, 캐비테이션-에로젼 특성에 미치는 용사조건의 영향에 중점을 비교분석하였다.

  • PDF

Hot Corrosion of NiCrAlY/(ZrO2-CeO2-Y2O3) Composite Coatings in Molten Salt (내열복합코팅 NiCrAlY/(ZrO2-CeO2-Y2O3)의 용융염 부식)

  • Lee, Jae-Ho;Lee, Dong-Bok
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.116-116
    • /
    • 2013
  • (Ni-22Cr-10Al-1Y)와 ($ZrO_2-25CeO_2-2.5Y_2O_3$)로 구성되는 금속/세라믹 복합코팅을 대기용사(ASP; air plasma spay)으로 철 기판위에 1:3, 2:2, 3:1의 무게비로 혼합하여 제조하였다. 용사된 코팅은 금속이영지역과 세라믹잉여지역으로 구별되고, 용사중에 NiCrAlY중의 Al이 선택적으로 산화되어 Al2O3가 계면에 존재하였다. 복합코팅은 $NaCl-Na_2SO_4$ 용융염에서 $800{\sim}900^{\circ}C$, 50시간 동안 부식실험을 실시하였다. 부식생성물은 NiO, $Cr_2O_3$, ${\alpha}-Al_2O_3$가 생성되는데, 부식이 진행되면서 용해되었다. 용융염 부식이 진행되는 동안에 Cr, Al이 외방확산하였고, Na, Cl, S는 내부로 확산되었다. 시간 및 온도뿐만 아니라 금속의 양이 증가할수록 코팅의 내식성은 저하되었다.

  • PDF