• Title/Summary/Keyword: 금속 스트립

Search Result 41, Processing Time 0.026 seconds

Evaluation of the proximal contact and comparison of methods for measuring in normal dentition (건강한 자연치열에서 인접면 접촉의 평가 및 측정방법에 따른 비교분석)

  • Ji-Eun Kim;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.198-203
    • /
    • 2023
  • Purpose. The aim of this study was to evaluate the proximal contact with a dental floss compared to a celluloid strip and a metal strip in normal dental arch and investigate what the most effective method for measuring is. Materials and methods. The subjects of this study was consisted with 20 healthy adults (10 males and 10 females) who had normal dentition. A dentist with more than 5 years of clinical experience evaluated the proximal contacts using a dental floss method, a celluloid strip method, and a metal strip method. Statistical analysis were performed by the use of Mann-Whitney U test. A P-value < .05 was considered statistically significant in all analysis. In addition, in the evaluation of proximal contact using a dental floss, the measurement of proximal contact using a celluloid strip and a metal strip was compared. Results. 80 % of all proximal contact was proper. Proper proximal contact was observed at the posterior area compared to the anterior area (P < .05). And male had proper proximal contact at the anterior area, female had proper proximal contact at the posterior area (P < .05). The consistency analysis between the results of the celluloid strip and the metal strip experiment on the results obtained from the floss using the consistency scale Kappa index shows that using celluloid strip is more advantageous than using the metal strip. Conclusion. Only 80% of all proximal contact was proper. Using celluloid strips with various thickness for evaluating of proximal contact is considered to be helpful for accurate measuring of proximal contact.

A Design of 3-Dimension Microstrip Antennas with Wide Bandwidth (광대역 3차원 마이크로스트립 안테나의 설계)

  • 오희태;조민규;김형동
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.5
    • /
    • pp.727-737
    • /
    • 1999
  • Printed microstrip antennas are known to have limitations in terms of bandwidth and efficiency all imposed by the presence of the dielectric substrate. In this paper, to overcome these limitations, rather than using a superstrate geometry, the printed circuit is etched out of metal and supported in "strategic points" by(metallic or nonmetallic) post. The main motivation for this work was to obtain the wide bandwidth microstrip antennal which exhibits a higher efficiency than conventional ones. In this paper, to increase the bandwidth, patch sizes, electrical thickness and impedance matching are considered.

  • PDF

Magnetic Sensor Using Giant Magneto-Impedance Effect (거대자기임피던스 효과를 이용한 자기 센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1057-1064
    • /
    • 2017
  • High sensitivity magnetic sensor having foreign metal detection capability is proposed utilizing giant magneto-impedance effect. Strip sensor showed the increasing output voltage when the external magnetic field was applied along with strip from strip grounding point, although the initial DC voltage varied depending on the pointing direction of strip sensor. Proposed sensor was able to eliminate more than half of background noise using active noise filter to achive high sensitivity, and it showed the capability to detect magnetized foreign metal object independent of ambient electro-magnetic noise and earth magnet. In case of ferrous sphere, the metal detection up to 0.8mm diameter was experimentally demonstrated at 5mm distance from strip sensor.

A Study on the Process Conditions Optimization for Al-Cu Metal Line Corrosion Improvement (Al-Cu 금속 배선 부식 개선을 위한 공정조건 최적화에 관한 연구)

  • Mun, Seong Yeol;Kang, Seong Jun;Joung, Yang Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.11
    • /
    • pp.2525-2531
    • /
    • 2012
  • Al-Cu alloy has been used as a circuit material for its low resistance and ease to process for long years at CMOS technology. However, basically metal is very susceptible to corrosion and which has been a long pending trouble in various fields using metal. The defect causes the reliability concerns, so improved methods are necessary to reduce the defect. In the various corrosion parameters, PR strip process conditions after metal etch and optimal cleaning solutions are controllable and increase the process margin to prevent the metal corrosion. This study proposes that chlorine residue after metal etch as the source of metal corrosion, and charges should be removed by optimizing PR strip process condition and cleaning condition.

Design of Multi-Meander Microstrip Patch Antenna for Metallic Object in u-City (u-City용 금속 부착을 위한 다중 미앤더형 마이크로스트립 패치 안테나 설계)

  • Choi, Yong-Seok;Seong, Hyeon-Kyeong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • In this paper, we present a design of meander type microstrip patch antenna which has the best quality in RFID approved international standard of 910MHz broadband, usable in metal environment. In order to be fit into the commercial tag chip on the antenna, a square shaped feeder is installed on the main body as well as in the main body. In addition, a multi meander type patching element was designed in order to reduce the main body effectively. Three antennae, Cases 1, 2 and 3, were designed and compared in the areas of broad band width, effectiveness or recognition distance according to their sizes and number of folds. The measurement result of Case 3 was determined to be the best. It was confirmed that mostly the efficiency and characteristic gain change due to antenna size and number of folds in meander type influenced the antenna recognition distance.

Propagation Characteristic in Parallel Plate Waveguide with Dielectric Layer Having Periodic Metal Strip Pattern (주기적인 금속 스트립 패턴을 갖는 유전체 층이 놓인 평행판 도파관내에서의 전파 특성)

  • Cho, Jung-Rae;Kim, Dong-Seok;Lee, Kee-Oh;Ryu, Sang-Chul;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.45-51
    • /
    • 2009
  • The propagation characteristics in parallel plate waveguide with dielectric layer having periodic metal strip pattern are investigated. PIN diode ON/OFF states are regarded as the short and open circuit, respectively, in the simulation using CST's MWS. The $11.25^{\circ}$, $22.5^{\circ}$, and $45^{\circ}$ layers which can be used for X-band 4-bit Radant lens phase shifter, are designed. The simulated results for each dielectric layer are $11.28^{\circ}$, $23.2^{\circ}$, and $46.22^{\circ}$, respectively. Also, the equivalent circuit of each layer at the operating band is realized and simulated using Agilent's ADS. The ADS simulated results are compared with the MWS simulated ones. Measured differential phase shills at the center frequency are $9.6^{\circ}$, $22.4^{\circ}$, and $43^{\circ}$, respectively.

Microstrip line tunable phase shifter (마이크로스트립 라인 가변 위상 천이기)

  • ;Mai linh
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.215-218
    • /
    • 2002
  • In this paper, we propose a microstrip line tunable phase shifter. If we vary the applied bias voltage, the relative dielectric constant of ferroelectrics also changes and we designed tunable phase shifter using Au/BSTO/MgO/Au structure. We also used a coupling structure to increase the amount of phase shift at certain frequency in a limited size and we could reduce the loss by reducing the line width.

  • PDF

Effect of Al Addition on the Microstructures of Rapidly Solidified Mg-Zn Alloy (급냉응고된 Mg-Zn합금의 응고조직에 미치는 Al첨가의 영향)

  • Kim, Yeon-Uk;Heo, Bo-Yeong
    • Korean Journal of Materials Research
    • /
    • v.7 no.6
    • /
    • pp.464-471
    • /
    • 1997
  • Melt-overflow 급냉응고장치를 이용하여 두께 약 300$\mu\textrm{m}$, 폭 10mm의 Mg-Zn합급 스트립을 연속적으로 제조하였다. 또한 알루미늄을 첨가하여, 첨가원소에 따른 결정립미세화와 기계적강도에 미치는 영향을 조사하였다. 스트립의 미세응고조직은 전자현미경(TEM, SEM)과 image analyzer를 이용하여 분석하였으며, 경도시험으로 기계적특성을 평가하였다. Mg-5wt%Zn합금 스트립의 경도는 결정립크기의 제곱근에 반비례하여 급냉응고에 의한 결정립미세화 효과로 같은 조성의 일반주조 합금보다 2배 이상의 높은 경도값을 가지며, 알루미늄을 첨가함으로서 2배 정도의 결정립미세화 효과를 얻어 경도가 더욱 증가하였다. 결정입계를 따라 생성된 금속간화합물은 마그네슘화합금의 입계부식을 방지하여 우수한 내식성을 갖는다. 따라서 적절한 합금설계와 급냉응고법을 적용시키면 마그네슘합금의 취약성을 보완하며 경량성의 장점을 최대한 활용할 수 있다.

  • PDF

Design and fabrication of rectangular waveguide-to-microstrip transition at Ka-band (Ka-band에서의 구형 도파관-마이크로스트립 변환구조의 설계 및 제작에 관한 연구)

  • 정진호;권영우;장영춘;천창율
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.7
    • /
    • pp.1770-1776
    • /
    • 1998
  • This paper presents a waveguide-to-mircostrip transition at Ka-band using antipodal finlines. Critical design parameters were identified with the help of theoretical analysis. Experimental optimization was performed together with 3-D FEM analysis in an effort to find optimum dimensions of the transition. In addition to the conventional antipodal finline transition, a new dielectric impedance transformer was introduced to further reduce the insertion loss. Optimized waveguide-to-microstrip transition showed an insertion loss of 0.3~0.4dB/transition at Ka-band. This transition provides superior reproducibility and better performance than conventional coaxcable-to-microstrip transition.

  • PDF