• Title/Summary/Keyword: 금속 부착

Search Result 258, Processing Time 0.033 seconds

Study on the Development of Finishing Design Methods for Building Structures Using the Metal Films (금속피막에 의한 건축 마감 의장 기법 개발에 관한 연구)

  • Lim, Ji-Taek;Jung, Hwa-Rang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.183-189
    • /
    • 2018
  • In this study, the bond strength between concrete and metal films was investigate according to changing water content ratio of substrate concrete by pull-out test in order to develop the new finishing design methods for building structures using the metal films. The following conclusions were obtained as a result of the studies. It was find that the colour of metal did not change before and after the metal spraying. Also, the water content ratio of substrate concrete must be controlled under 10% weight to confirm the standard bond strength of finishing material to concrete. 2.5 MPa. To enhance the bond strength between concrete and metal films, it is very effective to strengthen the concrete surface using the agent which strengthen the concrete surface and seal the pore of metal film by the sealing agents. Therefore, the control of concrete surface treatment and water content ratio are necessary to secure the bond strength of metal films.

Design of RFID Metal Tag Antenna with a Minimum Effect according to Attached Metal Surface Size (부착 금속면 크기에 따른 영향을 최소화 한 RFID 메탈 태그 안테나의 설계)

  • HwangBo, Chang;Seo, Seung-Up;Lee, Yun-Bok;Yang, Myo-Geun;Seong, Won-Mo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.978-984
    • /
    • 2008
  • In this paper, we propose a RFID metal tag antenna with a minimum by size of a metal surface to attach. This proposed tag antenna is a patch antenna which is able to stick on metal surface and designed for very slim structure ($119{\times}30{\times}1.6$ mm) antenna that is matched to a chip impedance. This has a loop coupling feeding and consists of a inner radiator and a outer radiator. The outer radiator activates the current to concentrate on the inner radiator regardless of metal size to attach. Also the tag antenna is designed by CST microwave tool and the performance is measured in the anechoic chamber. The optimum antenna has 3.77 % of the matching bandwidth($S_{11}<-10$ dB). The readable range of the tag antenna is about 2.9 m on metal(max. size $700{\times}700$ mm) and 5.5 m in free space according to the measurement results.

Design of Electric Transformer Supply Chain System using Metal Surface Mountable RFID Tag (금속 표면 실장용 RFID 태그를 이용한 변압기 자재 관리 시스템 설계)

  • Park, Chong-Ryol;Yun, Kee-Bang;Eom, Ki-Hwan
    • 전자공학회논문지 IE
    • /
    • v.48 no.4
    • /
    • pp.7-12
    • /
    • 2011
  • This paper described a metal mount RFID tag that works reliably on metallic surface. The proposed method is to use commercial RFID tags, Styrofoam103.7 material is attached on back side of RFID tag. Styrofoam103.7 material which has 2.5 mm thickness and 1.03 relative permittivity, was attached on back side of RFID tag. In order to verify the performance of proposed method, we evaluated the experiment on the supply chain system of electric transformers using RFID. The experimental results on supply chain of electric transformers show that the proposed tags can communicate with readers from a distance of 2 m. The results of recognition rates are comparable to commercial metallic mountable tags.

Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment (고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • The introduction of advanced water treatment facilities has increased as the conventional purification method cannot remove the substance clearly. However, the internal waterproofing and Anticorrosion materials of the advanced water treatment facility using ozone deteriorate due to the oxidation power of ozone and affects the concrete, which causes a decrease in durability. This study is to evaluate the ozone resistance according to the type of spray metal and the surface treatment method of the coating, and the bond strength after ozone treatment in order to develope a finishing method to prevent deterioration of concrete structure of water treatment facility using metal spraying method as a way to construct metal panel with excellent ozone resistance and chemical resistance by an easier way than the previous. The Experimental results show that spray metal Ti has superior ozone resistance even after spraying. It is considered to be the most suitable method for ozone resistance and bond performance by finishing using Teflon sealing as surface treatment method.

An Experimental Study to Secure Electromagnetic Pulse Shielding Performance of Concrete Coated by an Arc Metal Spraying Process (아크 금속 용사 공법에 의해 코팅된 콘크리트의 전자기파 차폐 성능 확보를 위한 실험적 연구)

  • Jang, Jong-Min;Jeong, Hwa-Rang;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.519-527
    • /
    • 2021
  • In this study, an electromagnetic pulse shielding effect was obtained by applying the arc metal spraying method to the ordinary concrete. For this study, to evaluate the electrical properties in the thickness of the metal sprayed coating, 8 types of metals(Cu, CuAl, CuNi, CuZn, Al, Zn, ZnAl, AlMg) were sprayed as coatings with a thickness of 100, 200 and 500㎛. The electrical conductivity on the surface was measured with a 4-pin probe, and an electromagnetic wave shielding effect test was performed according to KS. Based on the test results, 200 ㎛ was proposed as an optimal metal coating thickness for electromagnetic pulse shielding, and it was thermally sprayed on a 300×300×100mm concrete specimen to analyze the electromagnetic wave shielding performance. However, in the area of adhesion strength, the maximum was 1.11MPa, which was found to be less than 74% of the target performance.

고온고습 환경에서 태양전지 모듈의 성능 향상을 위한 연구

  • Kim, Ju-Hui;O, Won-Uk;Bae, Su-Hyeon;Kim, Dong-Hwan;Park, No-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.494.1-494.1
    • /
    • 2014
  • 태양광은 세계적으로 유망한 에너지 중의 하나이며, 태양광 모듈은 실제 옥외 조건에 따라 다르지만 장기 신뢰성과 수명을 보장하기 위해 최소 20년 이상을 안정적으로 작동될 필요성이 있다. 하지만 실제 태양전지는 옥외에 장기 노출됨에 따라 성능이 저하되며, 그 원인으로는 셀 균열, 부식, 접착 강도 손실 및 박리, 그리고 변색 등이 있다. 본 논문에서는 부식으로 인한 성능 저하를 완화하기 위해 희생금속을 이용하여 태양전지 모듈의 성능 향상에 대해 연구하였다. 태양전지는 4 cell 결정질 실리콘 태양전지 미니 모듈을 이용하였고, 희생금속의 영향을 확인하기 위해 두 종류의 시료를 준비하였다. 한 시료에는 Al 희생금속을 태양전지 리본 위에 부착하였으며, 나머지 한 시료는 비교 시료로 Al 희생금속을 부착하지 않았다. 시료는 $85^{\circ}C$ 85%의 상대습도인 고온고습 조건에서 2500시간을 진행하였다. 그리고 2500시간의 고온고습 시험이 진행된 시료의 전기적 특성을 분석하였다. 시험 결과, 희생금속이 없을 경우 28.8%의 출력 저하가 있었으며, 희생금속이 있을 경우 19.3%의 출력 저하가 확인되었다. 또한, 희생금속이 없을 경우, 충실도는 21.5% 감소하였으며, 단락전류 역시 약 6% 정도 감소하였다. 반면, 희생금속이 있을 경우, 충실도는 16.1%로 감소하였고, 단락전류는 거의 변화가 없었다.

  • PDF

UHF Band RFID Tag Antenna Mountable on metallic Object (금속에 부착 가능한 UHF 대역 RFID 태그 안테나)

  • Jung Jun-Mo;Yu Byung-Gil;Jung Byung-Woon;Lee Byung-Je
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.5 no.1 s.9
    • /
    • pp.65-70
    • /
    • 2006
  • A UHF band RFID passive tag antenna, which can be attached on metallic objects, is proposed. The proposed tag antenna is more insensitive to the size of the metallic object than conventional PIFAs or IFAs. It is constructed on a multi-layer and its size is reduced by using a 'L' slit. Performances of the antenna is analyzed by Ansoft's HFSS and measured using a back-scattering method. The simulated and measured data are obtained with varying the size of metallic object.

  • PDF

Fabrication of RFID Coil for Metal Surface (금속 표면 부착용 RFID 코일 제작)

  • Lee, Seong-Ho;Seo, Joung-Hyoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.7
    • /
    • pp.754-760
    • /
    • 2008
  • In this paper, we introduce an RFID planar coil whose inductance does not change when it is attached on the metal surface. The coil is designed considering the inductance reduction on metal surface so that the inductance is the inverse times the reduction rate, and copper pour is placed in the bottom layer of the coil. This coil configuration is very simple and effective in constructing RFID systems for managing objects with metal surface because it prevents inductance reduction on metal surface.

Tack welding for One Side $CO_2$ Arc Welding ($CO_2$ 편면 용접 의 가접 방법)

  • 김화연
    • Journal of Welding and Joining
    • /
    • v.2 no.1
    • /
    • pp.1-3
    • /
    • 1984
  • $CO_2$ 편면 용접은 편면 잠호 용접과 함께 작업 능률 향상, 작업 환경 개선 등의 잇점을 가지고 있어 국내의 조선소에서 많이 사용하고 잇는 용접 기법 중의 하나이다. $CO_2$ 편면 용접을 시공하기 위해서 가접보다는 strong back을 많이 사용하는데 strongback의 부착은 전 면과 후면에 부착시키는 2가지 경우가 있다. strongback을 전면에 부착할 경우 아아크는 strongback의 위치마다 중단된다. 후면에 부착할 경우 strongback으로 인한 아아크 중단은 없 어지나 용접사가 자세를 바꾸지 않고 한 번에 용접할 수 있는 최대 용접장은 1m정도이다. 이때 용접장 1m마다 아아크는 중단되게 된다. 이러한 아아크 중단부에는 용착 금속의 수축으로 인한 수축공(shrinkage hole)이 내재되어 용접 금속의 품질을 떨어뜨리므로 이를 제거하기 위해 용접 중 또는 용접 후에 gouging을 해야할 필요가 생긴다.

  • PDF

Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System (방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능)

  • Oh, Chang-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • A currently used roof green system with multi layers has a low constructability. Therefore a new integrated waterproof & root barrier sheet and roof green box unit system was developed using steel plate fixture and cone type fixture by electromagnetic induction heating method. This study was proceeded to evaluate adhesion performance of two types of fixtures on Engineering PE, TPO, PVC sheet in a normal condition, repeated heating and cooling condition. As a result, adhesion load on Engineering PE sheet showed the highest value. The adhesion loads of steel plate fixture showed higher value as heating temperature was getting higher. However adhesion loads of cone type fixture showed opposite tendency. Regarding to the test conditions, test results of normal condition, repeated heating and cooling condition showed same value. The cone type fixture using butyl tape showed 7 times lower adhesion load than that of cone type fixture using electromagnetic heating and 28% lower adhesion load in a repeated heating and cooling condition than a usual condition.