• Title/Summary/Keyword: 근접효과

Search Result 708, Processing Time 0.034 seconds

Analysis of the Combat Effectiveness of FFG with Guided-Rocket on the Threats of Multiple USV (다수 무인수상정 위협에 대한 호위함용 유도 로켓의 전투효과도 분석)

  • MIN, Seungsik;OH, Kyungwon;RYU, Jaekwan
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.5
    • /
    • pp.58-65
    • /
    • 2020
  • In this paper, the combat effectiveness of ship guidance rockets to counter the threat of multiple USV(Unmanned Surface Vehicle) was analyzed in three cases. The probability of sinking a number of USVs approaching by distance was compared using various weapon systems and guided rocket systems installed on the naval vessels. As a result of the analysis, it was found that the combat effectiveness of the guided rocket was improved compared to the close defense system of the anti-ship missile installed on the naval vessels.

Vibration Control of Offshore Platform using Tuned Mass Damper (동조질량감쇠기를 이용한 해양구조물의 진동제어)

  • Kim, Ju Myung;Lee, Gyu Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.73-79
    • /
    • 2004
  • Tuned Mass Damper (TMD) was applied to control the vibration of an offshore structure due to ocean waves. The errors caused by the linearization of the fluid-structure interaction effect and the phenomena when using the linearized equation of motion in TMD design were analyzed. To determine the performance of TMD in controlling vibration, both regular waves with varying periods and irregular waves with different significant wave heights were used. When the offshore structure received regular waves with a period similar to the first natural period of structure. TMD performed well in terms of response reduction. Such was not the case for the other periods. however, In the case of irregular waves, TMD triggered the reduction of structural response for waves with relatively small significant wave height. For irregular waves with relatively big significant wave height, however, TMD did not show any control effect. Therefore, TMD is useful in reducing offshore structural vibration due to ambient waves, thereby helping secure fatigue life.

An empirical study on the effect of distance decay for the relocated firms using distance-decay function by industrial types in the Seoul Metropolitan Area (거리조락함수를 이용한 수도권 지역간 기업이동 거리감쇄효과 실증 연구)

  • An, Youngsoo;Lee, Seungil
    • Journal of the Korean Regional Science Association
    • /
    • v.31 no.2
    • /
    • pp.47-61
    • /
    • 2015
  • The purpose of this study to empirical analysis of the effects of distance-decay for the relocated firms in the Seoul Metropolitan Area(SMA). In addition, this study was constructed distance-decay function for the relocated firms by industrial types using a general distance-decay function. The data of relocated firms in the SMA extracted from the spatial database which was constructed in an previous research. The industrial type divided into 3 parts which are construction, manufacturing, and service. The result of empirical analysis by each industrial type of the effect of distance-decay, the explanatory power($R^2$) of the each function were all high. In the construction, the adjusted $R^2$ of the distance-decay function was 0.728, the manufacturing was 0.802 and the service was 0.812. It means the effect of distance decay for the relocated firms in construction industrial type more big than the effects of distance decay for the manufacturing and service industrial types.

A Study on Securing Ship Survivability focused on a Cost and Effectiveness Analysis for Air Defense Performance (대공방어성능에 대한 비용효과분석을 중심으로 한 함정생존성 확보방안 연구)

  • Choi, Sung-Lin;Park, Dong-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2579-2586
    • /
    • 2014
  • It is crucial to set up early the required performance of surface ship for preventing the risk factors such as an excess of performance, cost and period in development stage. In this study, MOP and MOE are proposed to establish the method for deriving alternatives, MOP represents the defensive effect for anti ship missiles and MOE is the ratio of cost and performance. The 16 engagement scenarios which selectively install RF decoy, RF jammer, CIWS and anti air missile are suggested. The simulation results by using NORAM tool operated by ROK Navy show that the ship survivability is 0.605~0.975 and MOP is 0.301~0.887. The analyzed results represent the operating scenario with RF decoy, RF jammer and short range anti air missile is the best cost and effectiveness measure.

Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Comparison of Area Pricing and Cordon Pricing in General Equilibrium Models (구역혼잡통행료와 진입통행료의 비교)

  • Yu, Sang-Gyun;Jeong, Chang-Mu;Lee, Hyeok-Ju
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.2
    • /
    • pp.145-155
    • /
    • 2009
  • This paper compares the relative performances of area and cordon tolls as opposed to the first-best congestion tolls with respect to alleviation of traffic congestion and social welfare. The comparison is done in the monocentric city where all the jobs are located at the city center. The study shows that the size of charging zones is similar in the two second-bests, but that the optimal toll level is higher in area pricing than in cordon pricing. Area pricing schemes turn out to perform better than cordon pricing schemes as measured by average speeds and daily average travel time. Accordingly, the former is shown to increase the social welfare more than the latter. In the case of the cordon tolls, the residents at the charging zones are exempted from the tolls. In this way, cordon tolls invite people into the most congested areas over the optimal level while partially negating the whole spirit of the congestion tolls.

Control Effect of Vibration According to the Application Ratio of Electronic Detonator for Tunnel Blasting (터널발파시 전자뇌관 적용 비율에 따른 진동저감 효과 연구)

  • JongWoo Lee;TaeHyun Hwang;NamSoo Kim;KangIl Lee
    • Explosives and Blasting
    • /
    • v.42 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Through existing research and construction cases during tunnel blasting, the electronic blasting method is reported to be more effective in reducing blast vibration than the normal blasting method. However, due to the high price of electronic detonators, they are only used in some blasting sites where security objects are located nearby. Accordingly, this study performed tunnel blasting tests by adjusting the ratio of electronic and non-electronic detonators. And through the research results, the reduction effect of blasting vibration according to the detonator ratio was evaluated. The research results showed that the reduction effect of blast vibration was greatest when 100% electronic detonator was applied. In addition, when more than 52% of the electronic detonator was applied, it was found that the reduction effect was similar to the reduction effect when 100% of the detonator was used.

Physicochemical Properties and Antioxidant Activities of Maillard Reaction Products from Defatted Hydrolyzed Soybean Protein with Various Sugars (탈지대두단백 산 가수 분해물과 당의 반응에 의하여 생산된 Maillard Reaction Products의 이화학적 특성 및 항산화성)

  • Kim, Yoon-Sook;Moon, Ji-Hye;Kim, Myung-Hee;Choi, Hee-Don;Park, Yong-Kon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.1
    • /
    • pp.62-69
    • /
    • 2009
  • Maillard reaction products (MRPs) were produced from aqueous solution of various sugars with defatted hydrolyzed soybean protein (DFHSP) with different temperatures and pressures. Physicochemical properties of MRPs were investigated; also, DPPH and hydroxyl radical scavenging activity and sensory properties were evaluated. MRPs from ribose and DFHSP had the highest reactivity with larger pH reduce, higher browning index increase and higher antioxidant activity than other MRPs from other sugars. The antioxidant activities were increased with increasing temperatures and pressures of reaction. The highest antioxidant activity and sensory preference were obtained from MRPs with ribose at $140^{\circ}C$ with 2.8 kg/$cm^2$ for 30 mins.

The Dose Characteristics of Designed Ir-192 Micro-source for Brachytherapy (근접조사용 Ir-192 마이크로선원의 디자인과 선량 특성)

  • 최태진;김진희
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.81-89
    • /
    • 2003
  • The dose distributions of designed Ir-192 micro-source were investigated by dose computations which were accomplished by employing shape of encapsule material and thickness of the source for self-absorption. The computation dose derived from air-kerma rate (S$_{k}$ ) and dose rate constant (Λ) includes the anisotropy of dose distribution around the source. We got the dose rate constants in a water medium is 1.154 cGy h$^{-1}$ U$^{-1}$ . The size of the source was 0.5 mm in diameter and 3.5 mm in length and it was encapsuled in 1.1 mm$\Phi$${\times}$5.5 mm of stainless steel sealed with 0.3 mm of filter thickness. The tissue dose of reference point at 1.0 cm radial distance of the source axis was delivered 1.154 Uh$^{-1}$ (1.3167${\times}$10$^{-3}$ cGy/mCi-sec) from the S$_{k}$ 4.108U/mCi of Ir-192 source. The filtration effect contributed to air-kerma strength as exponential filtering effect of 86.2% in total attenuation, but self-absorption was 88.4% from radial dose distributions. In particular, the dose attenuations showed a rapid anisotropic distributions as 56% of reference dose along to $\pm$10 degrees from the tip of source axis and 50% for of that to source-cable direction. We persist in use the large diameter of applicator will avoid the dose anisotropy by the filtered attenuation effects along the axis of Ir-192 micro-source.

  • PDF