• Title/Summary/Keyword: 근위 상완골 골절

Search Result 53, Processing Time 0.037 seconds

Treatment of Two- and Three-Part Fracture of Proximal Humerus using LCP (잠김 압박 금속판(LCP)을 이용한 상완골 근위부 이분 및 삼분 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Park, Deok-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.204-211
    • /
    • 2007
  • Purpose: To evaluate the result and complication of treatment using Locking Compression Plate (LCP) for fracture of proximal humerus. Materials and Methods: Between 2004 and 2006, 21 patients with two-part and three-part fractures of the proximal humerus were treated by LCP fixation. Their average age was 54.9 years. Postoperative mean follow-up period was 22.9 months. The reduction was qualified and complication were assessed with final radiographs. The functional outcome was evaluated by Neer's rating system. Results: By Neer's functional evaluation, mean score of shoulder function was 86.3 and 18 case (86%) had excellent or satisfactory results. There was one case of nonunion but no infection or avascular necrosis of the humeral head. No correlation was found between the final result and the type of fracture, age, gender or quality of reduction. Conclusion: We obtained satisfactory result of LCP fixation for fracture of proximal humerus in this study. LCP fixation for proximal humerus fracture is a reliable method to obtain satisfactory reduction, rigid fixation and early exercise.

Operative Treatment with Locking Compression Plate (LCP) in Proximal Humerus Fracture (잠김 압박 금속판을 이용한 상완골 근위부 골절의 치료)

  • Ha, Sung-Sik;Kim, Jae-Young;Hong, Ki-Do;Sim, Jae-Chun;Kang, Jung-Ho;Park, Kwang-Hee
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.137-142
    • /
    • 2008
  • Purpose: To evaluate the clinical and radiographic results of the treatment of a proximal humerus fracture with a locking compression plate(LCP). Materials and Methods: This study reviewed the results of 24 cases of a proximal humerus fracture treated with a LCP from January 2005 to April 2007, after a follow up of more than 12 months. There were 8 males and 16 females with a mean age of 68.9(33-90) years. The clinical results were evaluated using the Neer's evaluation criteria, and the radiographic results were evaluated using the bone union time and Paavoleinen method. Results: The mean time for bone union was 11.9 weeks. Using the Neer's functional evaluation, 21 cases of the 24 patients (87%) showed excellent or satisfactory results. Twenty two cases (91%) showed good results according to the Paavoleinen method. The complications encountered were metal failure (1 patient), AVN of the humeral head (1 patient) and joint stiffness (1 patient). Conclusion: The LCP demonstrated good results in the treatment of a proximal humerus fracture and has relatively fewer complications than other internal fixators.

Minimal Invasive Plate Osteosynthesis in Proximal Humerus Fractures (상완골 근위부 골절에서의 최소 침습적 금속판 술식)

  • Shin, Sang-Jin;Do, Nam-Hun;Song, Mi-Hyun;Sohn, Hoon-Sang
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: In this study we introduced minimal invasive plate osteosynthesis (MIPO) and analyzed clinical outcomes to determine the effectiveness of this intervention in proximal humerus fractures. Materials and Methods: We studied 27 patients including 16 cases with a 2-part fracture, 10 cases with a 3-part fracture, and 1 case with a 4-part fracture. Clinical outcomes were evaluated using UCLA score, KSS score and recovery of range of motion. Time to union and humerus neck-shaft angle change were estimated by radiologic assessment. The average follow up period was 19 months. Results: UCLA scores were "excellent" for 15 patients, "good" for 12 patients. The mean KSS score was 91.4 at final follow-up. The average shoulder range of motion was $167.2^{\circ}$ in forward elevation. Bone union occurred by 14.1 weeks postoperatively. Humerus neck-shaft angle recovery was "excellent" in 24 patients and "moderate" in 3 patients. There were no complications such as axillary nerve paralysis, deep infection, or subacromial impingement of the plate. Conclusion: MIPO for proximal humerus fractures is an effective procedure if performed with sufficient understanding of the anatomical structures. MIPO leads to minimized dissection of soft tissue, low complication rates and early recovery of range of motion.

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

Recurrent Shoulder Dislocation and Proximal Humerus Fracture in Neurofibromatosis Type I - A Case Report - (제 1형 신경 섬유종증 환자에서 발생한 재발성 견관절 탈구 및 근위 상완골 골절 - 1예 보고 -)

  • Hwang, Tae Hyok;Cho, Hyung Lae;Wang, Tae Hyun;Yang, Hui Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.135-140
    • /
    • 2013
  • We report a case of recurrent shoulder dislocation and combined proximal humerus fracture in neurofibromatosis type I. A twenty-year-old male patient with known neurofibromatosis type I presented with right shoulder dislocation and proximal humerus fracture following a minor trauma. His injured arm also had large plexiform neurofibromas on the elbow, and the dislocation of the shoulder joint was proven to be recurrent. Bony deformation of the humerus and scapula were revealed on X-ray and computed tomography, as well as multiple neurofibromatic changes of the deltoid and periscapular muscles were noted on magnetic resonance imaging. Open reduction and capsular reconstruction were performed and humeral fracture was stabilized with a reconstruction plate. Satisfactory union and functional result were achieved and the dislocation did not recur until the 7-month followup after the procedure. Recurrent shoulder dislocation and combined proximal humerus fracture in neurofibromatosis type I are rare complications. However, it should still be considered in the orthopaedic evaluation process of the diseases.

Shoulder Arthropalsty for Fractures (골절에서의 견관절 인공관절술)

  • 전재명
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2003.11a
    • /
    • pp.175-180
    • /
    • 2003
  • 상완골 근위부 골절의 치료를 위해서 실시하는 상완골 두 치환술은 고난도의 수술이다. 그러나 수술 수기에 만전을 기하고 골절을 위해서 특별하게 고안된 치환물을 사용하면 통증을 해소되는 것은 물론이며 대부분의 견관절 기능도 회복이 가능하다고 생각한다. 또한 보다 좋은 결과를 얻기 위해서는 치환물과 수술 수기 등에 대해서 지속적인 개선이 매우 중요하다고 생각한다.

  • PDF