• Title/Summary/Keyword: 근단공

Search Result 6, Processing Time 0.016 seconds

EFFECT OF CANAL TAPERING IN TEETH OF VARIOUS APICAL SIZE & CROSS-SECTIONAL CONFIGURATION ON MICROLEAKAGE (다양한 치근단공 크기와 근관단면의 형태를 가지는 치아에서 taper의 정도가 미세누출에 미치는 영향)

  • Kim, Jung-Hee;Lee, Kyung-Ha;Lee, Se-Joon;Yu, Mi-Kyung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.95-101
    • /
    • 2005
  • The aim of this study was to evaluate the microleakage of teeth according to root canal preparation with & without apical enlargement in various size of apical foramen. 60 extracted one canal roots were cross-cutted at 5 mm from root apex and divided into two groups according to their apical foramen size of large (L) and small (S). Each group was subdivided into two groups accordance with their cross-sectional configuration at 5 mm from apex, round (R) and ovoid (O); SR Group, SO Group LR Group, LO Group. Each group was shaped in .02 taper by Quantec series Nickel-Titanium (NiTi) rotary file, obturated by lateral condensation method. Leakage was measured using a fluid transport model under 40 $cmH_2O$ pressure. After the leakage test, blocks which had showed the leakage retreated with .04 taper and ,06 taper and evaluated the degree of fluid filtration in each group. The data was analysed statistically using chi-square test and fisher's exact test. The results obtained were as follows : 1. Significant difference in leakage was found in groups which had different apical foramen size in .02 taper instrumentation (p < 0.05), but not in .04 taper instrumentation (p > 0.05) 2. The difference in microleakage according to the shape of canal was not evident at 5 mm from apex (p > 0.05). 3. There was correlation between .02 taper instrumentation and .04 taper instrumentation in LR group, LO group (p < 0.05).

APICAL PREPRATION SIZE IN INFECTED ROOT CANALS (감염근관에서의 apical preparation size)

  • Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.1
    • /
    • pp.1-4
    • /
    • 2010
  • The final preparation (MAF) size in infected root canals is still controversial. Nonetheless, recent studies demonstrated that larger apical preparation sizes produces a greater reduction in remaining bacteria and dentinal debris as compared to smaller apical preparation sizes. Therefore, clinicians should be practiced with treatment strategies guided by evidence-based information, especially in infected/failed root canals.

RADIOGRAPHIC STUDY OF THE POSITION OF APICAL FORAMEN IN ENDODONTIC THERAPY. (근관치료시(根管治療時) 근단공(根端孔)의 위치(位置)에 관(關)한 X-선학적(線學的) 고찰(考察))

  • Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.5 no.1
    • /
    • pp.35-40
    • /
    • 1979
  • The author observed thy actual position of apical foramen and the radiographic appearance of files when the files were filled through canals to the external surface of apical foramen in 280 canals of extracted teeth. All the teeth were radiographed by bisecting technic and once again Walton's projection was employed on mandibular molars. The results were as followings. 1. Sixty five percents of 280 canals were actually classed as having foramina deviant from true apex of root. 2. 160 of 280 canals(Fifty seven percents) appeared to be filled short of apex on the radiograph. 3. When Walton's projection was employed to open up two mesial canals of mandibular molars and compared to straight-on projection, twelve of 120 canals Ten percent appeared to be different in radiographic appearence.

  • PDF

SPECTROPHOTOMETRIC ANALYSIS ON THE SEALING EFFECT OF ULTRASONIC OBTURATION OF THE ROOT CANAL (초음파(超音波) 근관충진법(根管充眞法)의 폐쇄효과(閉鎖效果)에 관(關)한 분광광도계(分光光度界) 측정(測定))

  • Kim, Yang-Lag
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.46-57
    • /
    • 1990
  • The purpose of this study was to spectrophotometrically investigate the sealing effect of the ultrasonic canal obturation with softened gutta-percha utilizing an endosonic plugger by means of ultrasonic vibrations and heat. The 120 extracted human central and lateral incisors with single root were randomly selected, and the root canals were instrumented up to size #60 file by conventional method. The prepared canals were obtruated with gutta-percha by lateral condensation method, McSpadden technique and ultrasonic condensation method, with or without sealer. All specimens were immersed in 2% methylene blue in an incubator at $37^{\circ}C$ for 10 days. The teeth were then dissolved in 5ml of 60% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data statistically evaluated usint two-way ANOVA and Student's t-test. The results were as follows : No statistically significant difference in leakage was observed between the lateral condensation method and ultrasonic condensation method, with and without sealer. When sealer was used or not, McSpadden technique showed significantly greater leakage than lateral or ultrasonic condensation method. Statistical analysis of the data indicated that the canals obturated in conjunction with sealer demonstrated less dye leakage than the canals obturated without sealer(p<0.01), except McSpadden technique. The ultrasonic condensation method appeared comparable sealing ability to the lateral condensation method.

  • PDF

Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block (Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교)

  • Yoon, Min-Jung;Song, Min-Ju;Shin, Su-Jung;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.59-65
    • /
    • 2011
  • Objectives: The purpose of this study is to compare the apical transportation and working length change in curved root canals created in resin blocks, using 3 geometrically different types of Ni-Ti files, K3, NRT, and Profile. Materials and Methods: The curvature of 30 resin blocks was measured by Schneider technique and each groups of Ni-Ti files were allocated with 10 resin blocks at random. The canals were shaped with Ni-Ti files by Crown-down technique. It was analyzed by Double radiograph superimposition method (Backman CA 1992), and for the accuracy and consistency, specially designed jig, digital X-ray, and CAD/CAM software for measurement of apical transportation were used. The amount of apical transportation was measured at 0, 1, 3, 5 mm from 'apical foramen - 0.5 mm' area, and the alteration of the working length before and after canal shaping was also measured. For statistics, Kruskal-Wallis One Way Analysis was used. Results: There was no significant difference between the groups in the amount of working length change and apical transportation at 0, 1, and 3 mm area (p = 0.027), however, the amount of apical transportation at 5 mm area showed significant difference between K3 and Profile system (p = 0.924). Conclusions: As a result of this study, the 3 geometrically different Ni-Ti files showed no significant difference in apical transportation and working length change and maintained the original root canal shape.

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.