• 제목/요약/키워드: 근관치료

검색결과 378건 처리시간 0.026초

Digora$\textregistered$에서 노출시간의 변화가 근관치료용 file의 첨부식별에 미치는 영향 (The effects of various exposure times in the detectability on the tips of the endodontic files in Digora$\textregistered$)

  • 고지영;박창서
    • 치과방사선
    • /
    • 제27권1호
    • /
    • pp.55-71
    • /
    • 1997
  • Digora/sup (R)/ an intraoral digital radiography system utilizing image plate (IP) - has a dynamic range of exposure time which allows it to decrease the patient's exposure time and to increase diagnostic ability through image processing, transmission and storage. The purpose of this study was to evaluate the Digora/sup (R)/ system by assessing the effects of various exposure times on the detectability on the tip of the endodontic file. Examining the root canals of 45 extracted sound premolars, K -files No. 10, 15, and 20 were placed at slightly varying distances from the apex. The teeth were glued onto resin-plaster blocks. Five exposure times varying between 0.01 seconds and 0.25 seconds were used. Four observers were asked to measure the distance between the tip of the file and a reduction of crown portion, and obtained mean errors (subtracting true file length from the measured file length), comparing Digora/sup (R)/ monitors with E-plus films, which were both obtained under the same geometrical positions. The results were as follows : 1. Comparing E-plus film with Digora/sup (R)/ at 0.01 seconds, the mean errors in E-plus film showed -4.453 nun, -4.497 nun, and -3.857 nun, while the mean errors in Digora/sup (R)/ showed 0.065 nun, 0.607 nun, and 0.719 mm according to the file groups. Therefore there was a significant difference between E-plus film and Digora/sup (R)/(p<0.05). 2. By comparison of mean errors according to the various exposure times in the Digora/sup (R)/ system, the mean error at 0.01 seconds was significantly lower than that at 0.12 and 0.25 seconds in the No. 10 file group(p<0.05). And the standard deviation was the highest at 0.01 seconds. 3. Comparing E-plus film at 0.25 seconds with the Digora/sup (R)/ system, the mean errors showed a significant difference between E-plus film at 0.25 seconds and the Digora/sup (R)/ system at 0.25 seconds in No. 10 and 20 file groups(p<0.05). 4. Comparing E -plus film at 0.25 seconds with other exposure times, the mean errors showed a significant difference between E-plus film at 0.25 seconds and E-plus film at 0 .. 01 and 0.03 seconds in 10 file group(p<0.05). In the No. 15 and 20 file groups, there was a significant difference between E-plus film at 0.25 seconds and E-plus film at 0.01 seconds(p<0.05). In conclusion, Digora/sup (R)/ was better than E-plus film in detectability on the tip of the file at the exposure time of 0.01 seconds in all file groups. And we concluded that Digora/sup (R)/ can shorten exposure times up to 4% of 0.25 seconds (0.01 sec), which is adequate exposure time for premolar in E-plus film using No. 15 and 20 files.

  • PDF

Formocresol에 의한 치조골 괴사의 치험례 (NECROSIS OF ALVEOLAR BONE BY FORMOCRESOL : CASE REPORT)

  • 박철홍;이창섭;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제32권4호
    • /
    • pp.657-661
    • /
    • 2005
  • 유치의 치수절단술에 사용되는 약제로는 formocresol, ferric sulfate, 수산화칼슘 등이 있다. 그 중에서 formocresol은 치수조직의 고정능력과 높은 임상적 성공을 보임으로써 아직까지 널리 사용되고 있으나 자체독성이 매우 강하여 영구 계승치 치배의 변위나 결손, 법랑질 형성부전, 전신 흡수로 인한 돌연변이 가능성과 암유발 가능성 역시 보고되고 있다. 최근에는 formocresol의 근관내 적용시 불완전한 임시충전에 의한 미세누출로 주위 치은과 치조골의 괴사를 야기한 보고가 있으며 과잉의 formocresol을 적용하였을 경우에도 치조골의 괴사의 원인이 될 수 있다고 하였다. 본 증례는 개인치과에서 formocresol을 이용한 치수치료를 받은 후 지속되는 동통으로 인해 상악 좌측 제 2유구치를 발거하였으나, 증상이 개선되지 않아 본원에 의뢰되었다. 환아는 8세 남아로 심한 구취 및 계승 영구치 치관 주위로 환형의 치조골 괴사를 보여 부골절제술을 시행하고 1년 7개월간 관찰을 하였을 때 정상적인 치근 성장은 이루어졌으나 결손된 치조골 및 부착치은의 완전한 조직재생 소견은 관찰되지 않았다. Formocresol에 의한 치주조직에 대한 부작용은 비가역적이므로 formocresol의 사용에 있어 적응증 여부를 잘 판단해야 하며, 철저한 임시 가봉에 주의를 기울여야 할 것이다.

  • PDF

수근관증후군 환자에 대한 한방과 양방치료효과의 비교 (Comparison of Therapeutic Effect on Carpal Tunnel Syndrome between Oriental and Western Medicine)

  • 배형섭;홍진우;최창민;나병조;박성욱;문상관;박정미;고창남;조기호;김영석;정우상
    • 대한한의학회지
    • /
    • 제28권1호통권69호
    • /
    • pp.87-93
    • /
    • 2007
  • Objectives : This study was to assess the effectiveness of Oriental medical treatment on carpal tunnel syndrome, comparing its outcome with that of Western medical treatment. Methods : After being diagnosed with carpal tunnel syndrome by electromyography, subjects were enrolled in Kyung Hee Medical Center from March 2006 to January 2007. We prescribed Kejibokryung-hwan to the Oriental medical therapy group (OM group) and NSAIDS to the Western medical therapy group (WM group). Effectiveness was assessed by degree of pain using visual analog scale (VAS) before and after 3 weeks' treatment. Adverse effects were also monitored. Results : There were 21 patients in the OM group and 19 in the WM group. No statistical significant difference was detected at the baseline assessment. After 3 weeks of medication, pain was reduced about 26% in the OM group and 46% in the WM group. These findings might be explained by that more than half of the WM group received local steroid injection, which has been known to have more rapid analgesic effect that oral medication. Although pain reduction rate was higher in the WM group than in the OM group, we suggest that Oriental medical treatment is still effective, faking into consideration the fact that completely recovered cases were found only in the OM group. No adverse effect was found in either of the groups. Conclusion : This work could help us to understand the effectiveness of Oriental medical treatment on carpal tunnel syndrome.

  • PDF

근관치료시 Nd:YAG Laser 사용과 세척액에 따른 치근단 폐쇄효과의 비교 (THE EFFECTS OF ND:YAG LASER AND IRRIGANTS ON CANAL SEALING ABILITY)

  • 김진운;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.307-315
    • /
    • 2001
  • The application of Nd:YAG laser and irrigants to the root surface can change its surface configurations. The purpose of this study was to investigate the effects of Nd:YAG laser and irrigants on the apical seal of obturated canals. In this study, 66 single rooted teeth were randomly assigned to 4 group of 14 teeth each. 8 teeth were served us positive and negative controls. The teeth were divided into 6 groups as follows. Group A: Nd:YAG laser, 5% NaOCl + Rc-prep Group B: Nd:YAG laser, Saline Group C: 5% NaOCl + Rc-prep Group D: Saline Group E: Positive control Group F: Negative control 66 teeth were instrumented using Maillefer ProFile$^{\circledR}$ (Orifice Shapers, .04 taper, .06 taper Dentsply, Switzerland). Two of each group were selected at random, and the canal wall surfaces were examined under a SEM. 12 teeth of each group were obturated using by lateral condensation technique. Specimens were immersed in india ink for 7days, decalcified by 10% nitric acid, dehydrated by 75. 80. 85, 90, 95 and 100% alcohol in order cleared by methyl salicylate and then measured of dye penetration with stereomicroscope($\times$15 magnification) and Image Pro plus. The data were analyzed statistically by one-way ANOVA test and Duncan's Multiple Range test. The results were as follows : 1. The mean leakage was 0.128$\pm$0.376 for group A, 0.237$\pm$0.325 for group B, 0.397$\pm$0.468 for group C, 0.586$\pm$0.402 for group D, and there were statistically significant differences between group A and group D, group B and group D. (p<0.05). 2. Group A had better sealing ability than Group C, but there was statistically no significant differences. (p>0.05). 3. Group B had better sealing ability than Group D and there was statistically significant difference. (p<0.05). 4 Group A had better sealing ability than Group B, but there was statistically no significant difference. (p>0.05). 5. Group C had better sealing ability than Group D, but there was statistically no significant difference. (p>0.05). 6. As a result of observation under SEM, Smear layers were removed in Group A, B. but Smear layers were partially removed and smear plugs were remained in Group C, Smear layers were not removed in Group D. To be specially, Melting of smear layer were showed in Group C. 7. These results suggests that the laser has a potential in reducing the apical microleakage of obturated canals.

  • PDF

상아질 표면 젖음성이 수종 자가접착레진시멘트의 인장접착강도에 미치는 영향 (EFFECT OF DENTIN SURFACE WETNESS ON TENSILE BOND STRENGTH OF SELF ADHESIVE RESIN CEMENTS)

  • 윤성영;박세희;김진우;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제34권2호
    • /
    • pp.113-119
    • /
    • 2009
  • 본 연구의 목적은 다른 표면 젖음성을 갖는 상아질에 대한 수종의 자가접착레진시멘트의 인장접착강도를 비교하고자 하는 것이다. 이번 실험을 위해 Rely-X Unicem (3M, ESPE, St. Paul, MN, USA), Embrace Wetbond (Pulpdent, Oakland, MA, USA), Maxcem (Kerr, Orange, CA, USA) 3 종의 자기접착레진시멘트를 사용하였다. 발거한 상, 하악 대구치 60개를 미세절단기 (Acutom P-50, Struers, Copenhagen, Benmark)를 이용해 한 치아에서 $2mm{\times}2mm{\times}7mm$의 치아 시편 두개씩 얻었다. 상아질 표면을 건조 그룹은 10초간 강한 공기로 건조시켰고, 습윤 그룹은 과잉의 수분을 2 초간 거즈로 압박해 제거하였다. 상아질 표면의 젖음성을 달리한 시편에 자가접착레진시멘트를 접착한 후 상온의 상대습도 100% 상태에서 24시간 보관했고, 만능시험기 (EZ Test, Shimadzu corporation, Kyoto, Japan)를 이용해 인장접착강도를 측정했고, 분리된 접착면의 파절양상을 근관 치료용 현미경 (OPMI pro, Carl Zeiss, Oberkochen, Germany)을 이용해 20 배의 배율로 관찰하였다. $SPSS^{TM}$ Ver 10.0 (SPSS Inc., Chicago, IL, USA)을 사용하여 동일한 자가접착레진시멘트에서 상아질 젖음성에 따른 인장접착강도를 T-test로 비교하였으며, 각 자가접착레진시멘트간의 인장접착강도를 One way ANOVA test로 비교 분석하고 95% 유의수준에서 Scheffe's test로 사후검정 하였다. 실험 결과 자가접착레진시멘트의 인장접착강도는 상아질 젖음성에 영향을 받지 않았으며, 상아질 표면 젖음성과 상관없이 Maxcem의 인장접착강도가 Unicem과 Embrace의 인장접착강도보다 유의성 있는 낮은 값을 나타내었다. 또한 모든 시편의 분리된 접착면은 접착실패 양상을 나타내었다. 이상의 실험 결과로 볼 때 자가접착레진시멘트는 상아질 표면 젖음성에 상관없이 사용할 수 있을 것이라고 생각된다.

감염근관에서 분리 배양한 세균의 수종 항생제에 대한 감수성 조사 (Antibiotic Susceptibility of Bacteria Isolated from Infected Root Canals)

  • 임상수;김미광;민정범;김민정;박순낭;황호길;국중기
    • 미생물학회지
    • /
    • 제42권3호
    • /
    • pp.185-194
    • /
    • 2006
  • 본 연구는 치근관 감염병소에서 세균을 분리 및 동정하고, 8종의 항생제들에 대한 분리균주들의 감수성을 조사하기 위하여 실시하였다. 세균에 감염된 27개 치아의 괴사된 치근부 치부소직을 바비드 브로치나 페이퍼 포인트로 무균적으로 채취하였다. 치수가 채취된 부위의 바비드 브로치와 페이퍼 포인트를 500 ul의 $1{\times}PBS$ 용액에 담아 잘 혼합하고, 이를 5% 양혈이 포함된 BHI 한천배지(혈액한천배지)에 도말하여 $37^{\circ}C$ 혐기성 배양기에서 2-5일 동안 배양하였다. 혈액한천배지에서 자라난 세균은 16S rRNA 유전자(rDNA) 염기서열결정법을 이용하여 종수준으로 동정하였다. 이들 균주들의 8종 항상제에 대한 감수성은 최소성장억제농도 측정법으로 조사하였다. 본 연구결과, 101개의 세균 집락이 생겼고, Streptococcus spp. (29.7%)와 Actinomyces spp. (21.8%)가 가장 많이 검출되었다. 이들 균주들 중 9균주는 실험 도중 소실되거나 액체배지에 자라지 않아서 항생제 감수성 심험에서는 제외되었다. 각 항생제들에 대한 감수성을 조사한 결과, 분리된 균주들 중 80(87.0%) 균주가 클린다마이신에 감수성을 보였으며, 세프록심 아세틸과 테트라사이클린에 69(75.0%)가, 오그멘틴에 66(71.7%) 균주가, 페니실린 G에 63(68.5%) 균주가, 에리트로마이신에 61(66.3%) 균주가, 아목시실린에 41(44.6%) 균주가 감수성을 보였다. 그러나 시플록사신에는 29(31.5%) 균주만이 감수성을 보였다. 이러한 8종 항생제에 대한 균주들의 감수성 양상은 세균 종의 종류보다는 분리된 숙주에 따라 차이가 있었다. 이러한 결과는 치근관 감염질환의 치료에 항생제가 필요할 경우 항생제 감수성검사를 병행하는 것이 효과적임을 시사한다.

길경에서 추출한 polygalacin D가 근원세포 분화 및 근위축에 미치는 영향 (Effects of polygalacin D extracted from Platycodon grandiflorum on myoblast differentiation and muscle atrophy)

  • 송은주;허지원;장지희 ;김언미;정윤희;김민정;김성은
    • Journal of Nutrition and Health
    • /
    • 제56권6호
    • /
    • pp.602-614
    • /
    • 2023
  • 본 연구는 근생성 및 근위축 완화효능을 가진 유효소재 발굴의 필요성에 의해 polygalacin D가 근원세포 분화 및 미토콘드리아에 미치는 영향과 항암제 유도 근위축에 대한 완화효과를 각각 세포 및 동물실험을 통해 확인하고자 하였다. 그 결과, polygalacin D는 다핵을 지닌 근관세포의 수와 분화 종결인자인 MHC isoforms의 발현량을 증가시켰고 근육 내 단백질 분해 인자인 MuRF1, Smad2/3의 발현량은 유의적으로 감소시켰다. 또한 미토콘드리아 생합성 조절인자인 Pgc1α의 발현은 증가시키고 미토콘드리아 분열인자인 Drp1과 Fis1의 발현은 감소시켰다. 한편 zebrafish 동물모델을 통해 항암제 유도 근위축에 대한 개선효과를 확인한 결과, polygalacin D는 항암제에 의해 유도된 근위축과 미토콘드리아 손상을 완화시켰다. 이상의 결과들은 polygalacin D가 미토콘드리아 기능 증진을 매개로 근원세포 분화 촉진 및 근육 단백질 분해 저하 효과를 지닐 뿐만 아니라, 미토콘드리아 손상을 개선하여 항암제로 유도된 근위축에 대한 완화 효과를 나타냄을 시사한다. 따라서 본 연구를 통해 polygalacin D가 근생성 및 근위축 예방과 치료를 위한 잠재적인 유효소재로서의 가능성을 제시하였다.

섬유강화 복합레진 포스트의 결합강도에 대한 포스트 공간 적합도 및 접착 시멘트의 영향 (The influence of fitness and type of luting agents on bonding strength of fiber-reinforced composite resin posts)

  • 배꽃별;정혜윤;황윤찬;오원만;황인남
    • 구강회복응용과학지
    • /
    • 제39권4호
    • /
    • pp.187-194
    • /
    • 2023
  • 목적: 포스트와 포스트 공간의 크기 불일치는 포스트 수복 중 흔히 발생하는 문제이며, 이러한 불일치는 섬유강화 복합레진 포스트의 결합강도에 영향을 미치기 때문에 이를 보상할 수 있는 적절한 접착 시멘트가 필요하다. 연구의 목적은 섬유강화 복합레진 포스트의 결합강도에 영향을 미치는 포스트 공간의 적합도와 접착 시멘트 종류에 따른 영향을 평가하는 것이다. 연구 재료 및 방법: 발거된 30개의 하악소구치를 근관 치료한 뒤, 준비된 포스트 공간에 따라 Fitting (F)과 Mismatching (M)의 두 그룹으로 분류했다. 이들 그룹은 접착 시멘트 종류에 따라 다시 RelyX Unicem (ReX), Luxacore dual (Lux) 및 Duolink (Duo)의 세 가지 하위 그룹으로 추가로 분류했다. 이후 시편을 만들어 만능 물성 시험기 상에서 결합 강도를 측정했고 각 시편의 파절 양상을 관찰하여 분류했다. 결과: 실험의 결과로 ReX 및 Duo 하위 그룹에서는 F 그룹의 평균 결합 강도가 더 높았다. 그러나 Lux 하위 그룹은 F 그룹과 M 그룹 간에 큰 차이가 없었다. 파절 양상 분석에서 ReX 하위 그룹은 시멘트와 상아질 사이의 접착 실패만 관찰되었다. 결론: 본 연구 결과, 섬유강화 복합레진 포스트의 결합강도는 접착 시멘트의 종류, 포스트 공간과 포스트 직경의 불일치에 의해 영향을 받는 것으로 나타났다. Rex는 다른 접착 시멘트와 비교 시 유의하게 높은 결합강도를 보였다. 포스트 직경은 모든 그룹에서 F그룹이 M그룹보다 높은 결합강도를 보였으며, 이 값은 ReX와 Duo 두 그룹에서 유의한 것으로 나타났다.