• Title/Summary/Keyword: 근관만곡

Search Result 58, Processing Time 0.022 seconds

COMPARISON OF MAINTENANCE OF CANAL CURVATURE IN CURVED CANALS SHAPED WITH FOUR DIFFERENT FILE TYPES (만곡근관에서 수종의 File을 이용한 근관형성시 만곡도 변화에 대한 비교 연구)

  • Shin, Joo-Hee;Kwon, O-Yang;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.388-395
    • /
    • 1997
  • Maintaining the original canal path during instrumentation is a challenge in narrow curved canals. This study compared the maintenance of the original canal path of curved root canals during instrumentation with two kinds of stainless steel K-files(Brassler USA & Mani Japan), K-flexofiles(Maillefer Swiss) and Ni-Ti files(Brassler USA, Savannah, GA) using circumferential filing technique to # 40 MAF on 60 extracted human molars. Buccal and mesial canals with minimal initial curvature of 20 degrees were used. The maximal initial curvature was 41.5 degrees. Sixty curved canals divided into four groups according to file type(Group 1 : Ni-Ti file, Group 2 : K-flexofile, Group 3: K-file(Brassler), Group 4 : K-file(Mani)). Radiographs of canals were obtained before and after canal shaping. And postoperative radiographs were compared with preoperative radiographs using superimposition method. Data analysis was performed using Covariance analysis and paired-comparison test. The results observed were as follow ; 1. The angle of curvature was better maintained with Ni-Ti file than with stainless steel files. (p<0.01) 2. There was no significant difference in maintaining canal curvature between K-flexofile, Brassler$^{(R)}$ K-file and Mani$^{(R)}$ K-file, although there was some differences in mean values of postoperative canal curvature. 3. Paired-comparison t test revealed significant differences within each of the three stainless steel file types when comparing the mean differences before and after instrumentation, but no significant differences were observed within Ni-Ti file group.

  • PDF

Microleakage Assessment of a Pozzolan Cement-based Mineral Trioxide Aggregate Root Canal Sealer (포졸란 시멘트를 기반으로 하는 근관전색제의 치근단부 미세누출 평가)

  • Kim, Mijun;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • This study aimed to assess microleakage of Endoseal MTA when it is used as a root canal sealer and a root canal filling material compared with conventional endodontic treatment materials Forty-two mature human permanent teeth with a single root canal were divided randomly into three experimental groups (n = 10) and two control groups (n = 6). Group A was obturated with AH $plus^{(R)}$ and gutta-percha (GP). Group E1 was obturated with Endoseal MTA and GP. Group E2 was obturated with Endoseal MTA only. The positive control group was obturated with GP only and the negative control group was obturated in the same way as the experimental groups. The samples were kept in saline solution for 24 hours and were immersed in 0.2% rhodamine B dye solution for 24 hours. Then the samples were split longitudinally and the micoleakage was assessed under a stereomicroscope. Complete microleakage was detected in all positive control group samples, whereas no microleakage was detected in the negative control group. There was no statistically significant difference between the experimental groups in the Kruskal-Wallis test. These results suggest that Endoseal MTA has potential use as a root canal sealer and a root canal filling material.

PULP REVASCULARIZATION OF IMMATURE FIRST PERMANENT MOLARS WITH APICAL PERIODONTITIS : CASE REPORT (치근단 치주염을 가진 미성숙 제1대구치의 치수 재혈관화 : 증례 보고)

  • Jeon, Hye-Jin;Yang, Yeon-Mi;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.192-198
    • /
    • 2012
  • Revascularization of the pulp in a necrotic, infected immature tooth with apical periodontitis was attempting several years. Revascularization of partially necrotic pulp in an immature tooth is based on the concept that vital dental stem cells can survive pulpal necrosis. Revascularization procedure obtains longer and thicker roots in teeth with necrotic pulp diagnosis. Pulp revascularization for immature permanent molars can be possibly applied on cases having difficulty to use conventional root canal treatment due to abnormally thin root canal wall or severe root curvature. Also, when an uncooperative patient does not agree with sedative treatment the revascularization can be useful. And a patient with disability who is barely cooperative can be another indication of this treatment. In this case report, pulp revascularization using triple-antibiotics, metronidazole, ciprofloxacine and minocycline, was applied on the immature first permanent molar infected by caries.

THE EFFECT OF CANAL OBTURATION ACCORDING TO THE DEPTH OF THE SYSTEM B PLUGGER TIP IN THE TYPE IV CANAL (제 IV 형 근관에서 System B Plugger tip의 깊이에 따른 근관 충전 효과)

  • Choi, Hee-Won;Kim, Soo-Mee;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.518-525
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of the apical sealing according to the depth of the System B Plugger tip when root canal was filled with gutta-percha and sealer by Continuous Wave of Condensation technique in the Type IV canal. 50 simulated resin blocks with J-shaped curvature canals were instrumented by ProTaper (Dentsply Maillefer, Ballagiues, Switzerland) Ni-Ti files using the crown-down technique. Type IV canals were made using a broken ProTaper F3 Ni-Ti file for making a ledge at 3mm short from the working length. And ProTaper F1 Ni-Ti file was used for perforating resin block. The prepared Type IV canals were randomly divided into three experimental groups of 15 each according to the depth of System B Plugger tip. All of experimental groups were obturated with Continuous Wave of Condensation technique. The length of gutta-percha and sealer in lingual of the Type IV canals was measured with a measuring digital calliper under magnifying glass (${\times}2.3$). The results are as follows : 1. In control group, there was no gutta-percha and sealer in lingual canal. 2. 3 mm group showed relatively more gutta-percha than 5mm or 7 mm group (p<0.05). 3. 7 mm group did not showed gutta-percha and relatively more void were observed than 3mm or 5 mm group. (p<0.05) In conclusion, within the limits of the results of this experiment, the 3 mm depth of System B Plugger tip was acceptable for obturating the Type IV canal.

A STUDY OF INSERTION DEPTH OF GUTTA PERCHA CONES AFTER SHAPING BY NI-TI ROTARY FILES IN SIMULATED CANALS (레진모형 근관에서 Ni-Ti 파일로 근관성형 후 거타퍼챠콘의 근관내 삽입깊이에 대한 연구)

  • Cho, Hyun-Gu;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.550-558
    • /
    • 2007
  • The purpose of this study was to evaluate the insertion depth of several brands of master gutta percha cones after shaping by various Ni-Ti rotary files in simulated canals. Fifty resin simulated J-shape canals were instrumented with ProFile, ProTaper and HEROShaper. Simulated canals were prepared with ProFile .04 taper #25(n=10), .06 taper #25(n=10), ProTaper F2(n=10), HEROShaper .04 taper #25(n=10) and .06 taper #25(n=10). Size #25 gutta percha cones with a .04 & .06 taper from three different brands were used: DiaDent; META; Sure-endo. The gutta percha cones were selected and inserted into the prepared simulated canals. The distance from the apex of the prepared canal to the gutta percha cone tip was measured by image analysis program. Within limited data of this study, the results were as follows 1. When the simulated root canals were prepared with HEROShaper, gutta-percha cones were closely adapted to the root canal. 2. All brands of gutta percha cones fail to go to the prepared length in canal which was instrumented with ProFile, the cones extend beyond the prepared length in canal which was prepared with ProTaper. 3. In canal which was instrumented with HEROShaper .04 taper #25, Sure-endo .04 taper master gutta percha cone was well fitted(p < 0.05). 4. In canal which was instrumented with HEROShaper .06 taper #25, META .06 taper master gutta percha cone was well fitted(p < 0.05). As a result, we concluded that the insertion depth of all brands of master gutta percha cone do not match the rotary instrument, even though it was prepared by crown-down technique, as recommended by the manufacturer. Therefore, the master cone should be carefully selected to match the depth of the prepared canal for adequate obturation.

ABILITY OF NICKEL-TITANIUM FILES IN MAINTAINING THE ORIGINAL CURVATURE OF A CURVED ROOT CANAL AND ITS ANALYSIS BY FINITE ELEMENT METHODS (만곡 근관 형성시 니켈-티타늄 파일의 만곡 유지 능력과 그에 대한 유한요소법적 분석)

  • Park, Han-Soo;Lim, Sung-Sam;Bae, Kwang-Shik;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.220-227
    • /
    • 1997
  • The purpose of our study is to evaluate the ability of nickel-titanium(NiTi) files in maintaining the original curvature of a curved root canal during canal preparation. Curved canals on translucent resin blocks were prepared with NiTi and stainless steel files, and they were placed at the platform which can reproduce the same position. The unprepared and prepared canal forms were accurately compared by double exposure technique of photography. By finite element methods we also analyzed stress distributions of NiTi and stainless steel files in a curved canal. The results were as follows : 1. NiTi files were excellent in maintaining the original curvature of a curved canal than stainless steel files after canal preparation. 2. The results of canal preparation with these files were well verified by the analysis of stress distributions using finite element methods.

  • PDF

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

EFFECT OF VARIOUS CANAL PREPARATION TECHNIQUES USING ROTARY NICKEL-TITANIUM FILES ON THE MAINTENANCE OF CANAL CURVATURE (수종의 엔진구동형 Nickel-Titanium file을 이용한 근관형성 방법이 근관만곡도 유지능력에 미치는 영향)

  • Lee, Cheol-Hwan;Cho, Kyung-Mo;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.41-49
    • /
    • 2003
  • There are increasing usage of Nickel-Titanium rotary files in modern clinical endodontic treatment because it is effective and faster than hand filing due to reduced step. This study was conducted to evaluate the effect of canal preparations using 3 different rotary Nickel-Titanium files that has different cross sectional shape and taper on the maintenance of canal curvature. Simulated resin block were instrumented with Profile(Dentsply, USA), GT rotary files(Dentsply, USA), Hero 642(Micro-Mega France), and Pro-Taper(Dentsply, USA). The image of Pre-instrumentation and Post-instrumentation were acquired using digital camera and overspreaded in the computer. Then the total differences of canal diameter, deviation at the outer portion of curvature, deviation at the inner portion of curvature, movement of center of the canal and the centering ratio at the pre-determined level from the apex were measured. Results were statistically analyzed by means of ANOVA, followed by Scheffe test at a significance level of 0.05. The results were as follows; 1. Deviation at the outer portion of curvature, deviation at the inner portion of curvature were showed largest in Pro-Taper so also did in the total differences of canal diameter(p<0.05). 2. All the groups showed movements of center Profile combined with GT rotary files and Hero 642 has no difference but Pro-Taper showed the most deviation(p<0.05). 3. At the 1, 2, 3mm level from the apex movements of center directed toward the outer portion of curvature, but in 4, 5 mm level directed toward the inner portion of curvature(p<0.05). As a results of this study, it could be concluded that combined use of other Nickel-Titanium rotary files is strongly recommended when use Pro-Taper file because it could be remove too much canal structure and also made more deviation of canal curvature than others.

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file (Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교)

  • Lim, Yoo-Kyoung;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.385-396
    • /
    • 2007
  • The aims of this study were to compare the shaping effect and safety between single length technique recommended by manufacturer and crown-down technique using Mtwo rotary file and to present a modified method in use of Mtwo file. Sixty simulated root canal resin blocks were used. The canals were divided into three groups according to instrument and the manner of using methods. Each group had 20 specimens. Group MT was instrumented with single length technique of Mtwo, group MC was instrumented with crown-down technique of Mtwo and group PT was instrumented with crown-down technique of ProTaper. All of the rotary files used in this study were operated by an electric motor. The scanned canal images of before and after preparation were superimposed. These superimposed images were evaluated at apical 1 to 8 mm levels Angle changes were calculated. The preparation time, weight loss, instrument failure and binding, canal aberrations, and centering ratio were measured. Statistical analysis of the three experimental groups was performed with ANOVA and Duncan's multiple range tests for post-hoc comparison and Fisher's exact test was done for the frequency comparison. In total preparation time, group MT and group MC were less than group PT. In the aberrations, group MT had more elbows than those of group MC and group PT. The binding of group MC was least and group MT was less than group PT (P < 0.05). Under the condition of this study, crown-down technique using Mtwo rotary file is better and safer method than single length technique recommended by the manufacturer.

A Study on the Shaping Ability of Three Different Rotary Nickel-Titanium Instruments in Simulated Curved Root Canal (만곡 근관에서 다양한 엔진 구동형 Nickel-Titanium 파일의 근관 성형능력에 대한 연구)

  • Kim, Kyoung-A;Chon, Seong-Min;Kwon, Su-Mi;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.293-302
    • /
    • 2007
  • I. Objectives The purpose of this study was to compare the shaping ability between the single length technique performed with Mtwo instruments (VDW, Munich, Germany) and the crown-down technique using K3 (SybronEndo, West Collins, CA, USA) and RaCe (FKG, La Chaux-de-Fonds, Switzerland) instruments. II. Materials & Methods Forty five curved canals in resin blocks were equally divided in to three groups. Group 1 (Mtwo) was instrumented used the full length of canal according to the manufacturer's instructions. The simulated canals was prepared to an instrument size of 35, 0.04 taper canal terminus. In group 2 (Race) and group 3 (K3) was instrumented in a crown-down manner and prepared to an instrument size of 30, 0.06 taper canal terminus. Pre- and post-instrumentation images were scanned and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 7 measuring points, beginning 1mm from the end point of preparation. Differenced of centering ratio were statistically analyzed using One-way ANOVA followed by Duncan's test. II. Results & Conclusion There was no significant difference on 1, 2, 3 and 7mm measuring point. At 4 and 5 measuring point, significant difference showed between the Mtow instruments and other two instruments. (p<0.05)