• Title/Summary/Keyword: 근거리난시

Search Result 14, Processing Time 0.031 seconds

A Study for the Change and Distribution of Far Sighted and Near Sighted Astigmatism Power according to Age (연령에 따른 원·근거리 난시의 굴절력 변화에 대한 연구)

  • Joo, Seok-Hee;Park, Seong-Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.25-36
    • /
    • 2007
  • We researched the change of astigmatism power when the fixation point moved from far distance to near distance. Astigmatism power was measured by using both eyes open-view auto-refractometer. We divided the ages between 5 and 67 years old into 12 groups with 1,598 healthy eyes(male-698 eyes and female-900 eyes) without eyes problems and experiences of eyes operations. The mean power in far astigmatism showed that with-the-rule of the total astigmatism: -0.79D, with-the-rule of the corneal astigmatism: -1.07D and against-the-rule of the residual astigmatism : -0.79D were found most respectively. The correlation between cornea astigmatism and total astigmatism was y=0.7493 x + 0.5661 r=0.6510, residual astigmatism and total astigmatism was y=0.248 x - 0.5926 r=0.2598 and corneal astigmatism and residual astigmatism was y=-0.4439 x - 0.1813 r=-0.5551 in the far distance. The mean power in near astigmatism showed that with-the-rule of total astigmatism : -0.92D, with-the-rule of corneal astigmatism : -1.12D, against-the-rule of residual astigmatism : -0.87D were found most respectively. In the near distance, The correlation between corneal astigmatism and total astigmatism was y=0.6872 x + 0.5934 r=0.6204, residual astigmatism and total astigmatism was y=0.303 x - 0.6066 r=0.3165, corneal astigmatism and residual astigmatism was y=-0.46 x - 0.0626 r=-0.5322. When the fixation point moved far distance to near distance, the differences of power according to the type of astigmatism were total astigmatism: $-0.07D{\pm}0.44D$, corneal astigmatism: $-0.04D{\pm}0.54D$ residual astigmatism:$0.01D{\pm}0.53D$. Most of astigmatism refractive power was increased except for oblique-the -astigmatism. When the fixation point moved far distance to near distance, the change of astigmatism refractive power showed total astigmatism: 540 eyes(33.7%), corneal astigmatism: 638 eyes(39.9%), residual: 841 eyes(52.6%).

  • PDF

A Study on the Accommodative Astigmatism of Near Vision (근거리 주시 시 조절성 난시에 대한 연구)

  • Lee, Hark-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.327-331
    • /
    • 2011
  • Purpose: The purpose of this study was an accurate grasp of the astigmatic change due to eyes accommodation on near vision and suggested problems occurring accommodative astigmatism using near glasses. Methods: 154 subjects(308eyes) from 20 to 40 years selected for this study who had many opportunity of near vision. First, far vision corrective refraction measured using the phoropter, and then both eyes opened simultaneously for maintaining the function of binocular put away dot chart 40 cm. One eye was fogging and the other eye measured near vision astigmatism axis and degrees astigmatism using cross cylinder, and then compared with far astigmatism. Results: Increased degree of astigmatism persons on near vision more than decreased or did not changed degree of astigmatism persons, which could affect visual acuity more than 0.75 diopters in 30 eyes with an increase of 9.7% of total subjects. Direct astigmatism and oblique astigmatism were increased on near vision. Astigmatic axes were rotated base in direction on both eyes and 66.9% of subjects were more than ${\pm}$5$^{\circ}$ rotation. Due to the rotation axis of astigmatism, residual astigmatism is expected to occur and expect to adversely affect the eyes. Conclusions: Long-term using the glasses without correction of increased astigmatic and rotated axis on near vision should occur new residual astigmatism and increase the asthenopia also. Considered to be taken astigmatic change on near vision during near refraction examination.

A Study for the Change of Astigmatism Axis When the Fixation Point Moved Far Distance to Near Distance (원거리에서 근거리 주시 시 난시축 변화에 대한 연구)

  • Joo, Seok-Hee;Sim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.47-59
    • /
    • 2007
  • When the fixation point moved far distance to near distance, the change of astigmatism type in total astigmatism showed no-changed eyes: 1,020 eyes (63.8%), changed eyes: 578 eyes(36.1 %). The change of with-the-rule into oblique-astigmatism, oblique-astigmatism into with-the-rule, against-the-rule into oblique-astigmatism of change was plenty the most respectively. In corneal astigmatism was no-changed eyes: 1,164 eyes (72.8%), changed eyes: 434 eyes(27.1%). The change of with-the-rule into oblique-astigmatism, oblique-astigmatism into with-the-rule, against-the-rule into with-the-rule astigmatism was plenty the most respectively. In residual astigmatism is no-changed eyes: 935 eyes(58.5%), changed eyes: 663 eyes(41.4%). The change of with-the-rule into oblique-astigmatism, oblique-astigmatism into against-the-rule, against-the-rule into oblique-astigmatism was plenty the most respectively. When the fixation point moved far distance to near distance, the change of astigmatism axis in total astigmatism was no-changed eyes: 761 eyes(48.5%), cyclotorsioned eyes the above 10 degrees: 837 eyes(52.3%). In corneal astigmatism was no-changed eyes: 846 eyes(52.9%), cyclotorsioned eyes the above 10 degrees : 752 eyes(47%). In residual astigmatism was no-changed eyes: 614 eyes(38.4%), cyclotorsioned eyes the above 10 degrees : 984 eyes(62.5%). The magnitude of cyclotorsion of astigmatism axis in total astigmatism was Counter clockwise rotation: 31 degrees, clockwise rotation: 20 degrees. In coneal astigmatism was Counter clockwise rotation: 25 degrees, clockwise rotation: 27 degrees. In residual astigmatism was Counter clockwise rotation: 33 degrees, clockwise rotation: 35 degrees.

  • PDF

A Study of Accommodative Response on Emmetropia (정시안의 조절반응량에 관한 연구)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Joo, Seog-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.187-192
    • /
    • 2006
  • The purpose of this research was to measurement real accmmnodative response amount of emmetropia using both eyes open-view auto-refractometer. We classified 377(male 146, female 231)eyes showing good naked vision at least 1.0, with a spherical equivalent refraction of under ${\pm}0.50D$ and cylindercal refraction of under -0.75D, from 10 to 59(mean $25.8{\pm}12.4$) years into 5 groups with 10 year interval and analyzed change of the near astigmatism and accommodative response amount to distinction of age. Age comparison, total mean 1.47D, 10 years age group 1.63D, 20 years age group 1.57D, 30 years age group 1.71D, 40 years age group 0.97D, and 50 years age group 0.05D. It was no difference between 10 to 30 years age group, But it showed the decre8.se which is remarkable from above 40 years age group and it does not almost response from above 50 years age group. Sexual difference, the man appeared some highly in male(mean $26.4{\pm}12.3$ years) 1.56D m female(mean $26.4{\pm}12.3$) 1.43D. Near-astigmatism power change, mean +0.12D, 10 years age group +0.06D, 20 years age group +0.16D, 30 years age group +0.09D, 40 years age group +0.05D, and 50 years age group +0,06D. No significant difference of astigmatism powers among the an groups, but from all years age group the astigmatism power appeared more highly far-astigmatism than near-astigmatism. Near-astigmatism axis change in the far-astigmatism changes at under ${\pm}10^{\circ}$ 103 eyes, above ${\pm}10^{\circ}$ rotation clockwise direction 108 eyes, above ${\pm}10^{\circ}$ rotation counter-clockwise direction 101 eyes. It was analyzed near-astigmatism axis change.

  • PDF

The Evaluation of Reliability for Exam Distance of Visual Acuity (시력검사거리에 따른 원거리 시력검사 신뢰성 평가)

  • Chun, Young-Yun;Choi, Hyun-Soo;Park, Seong-Jong;Lee, Seok-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • Purpose: We aimed to evaluate reliability of eye exam for visual acuity as a function of distance. Methods: There were 39 patients (78 eyes) who had visual acuity 1.0 or more at 5 meters. We measured refractive power of patients at each distances, 5 meters, 4 meters and 3 meters. Automatic chart (LCD-700, Hyeseong Optic. Co., Korea) used for visual acuity, skiascope (Beta 200, Heine, Germany) and auto refractometer (RK-5, Canon, Japan) used as for objective refraction. Accommodation was examined by minus lens addition methods, and Accommodative lag was examined by grid chart for reading distance. Results: Being compared to 3 meter test, Amount of corrected spherical refractive power decreased by $0.10{\pm}0.38$ D, astigmatism decreased by $0.05{\pm}0.10$ D, and axis of astigmatism rotated toward to temporal by $2.64{\pm}18.75$ degrees for right eyes, by $11.43{\pm}48.55$ degrees for left eyes in case of 5 meter test. Changes of corrected refraction and astigmatism were slightly correlated (r=-0.31, r=-0.29). Conclusions: Because corrected refraction power and amount of astigmatism decreased and axis of astigmatism tends to turn the temporal direction according to exam distance, examination distance of visual acuity should improved as to 5 meters.

Analysis of Adaptation for The first-time Progressive Lenses Glasses Wearers (누진렌즈 안경 처음 착용자의 적응도 분석)

  • Shim, Jun-Beom;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.117-122
    • /
    • 2011
  • Purpose: This study analyzed the factors related to adaptation of people who wears progressive lenses glasses for the first time. Methods: 463 presbyopia (Aged 41~78) without any ocular diseases with the progressive lens glasses were prescribed from 2010 to 2011 at B clinic in the Gwangju city. Progressive lenses adaptation were analyzed according to gender, age, distance refractive state, presbyopic addition, progressive lens design, the old glasses, astigmatism type, and anisometropia etc. High, mid and low-adapted groups were categorized as the status of wearing progressive lenses glasses, re-wearing, occasionally wearing and failed to weraing, respectively. Results: Men showed significantly higher adaptation (p=0.02) than women. Presbyopic addition (p=0.05) and progressive lens design (p=0.02) were statistically significant. However, it was found that there was so statistical significance for the factors of age, distance refractive state, the old glasses, astigmatism type, and anisometropia. Conclusions: According to the results of this study, when progressive lenses were prescribed, we should consider for adaptation gender, presbyopic addition, and progressive lens design etc.

Clinical Study on Tendency of Addition Power with Age (연령별 노안 가입도 경향에 관한 임상적 연구)

  • Kim, Mi-Yeon;Kim, Jae-Gwang;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.131-135
    • /
    • 2006
  • The purposes of this study is examining a wearing tendency of a progressive multifocal lens. We measured refractive error values using subjective and objective refraction method with subjects in 40-65 ages. Also, we investigated and analyzed distribution of addition power and wearing tendency of progressive multifocal lens. Detected addition powers were ranged of +0.75D - +3.00D. In case of average addition, they were detected with +1.18D in 40's, +1.55D - +1.97D in 50's and +2.38D in above 61's age. The distributions of visual ability at a distant were measured that the hyperopia and hyperopic astigmatism 43%, the myopia and myopic astigmatism characteristic astigmatism 7% appeared highly with 36%. The male who uses the interior aspect multi focal lens with the short-range work were appeared the male 20%, the woman 19%.

  • PDF

A Clinical Study on Presbyopia in Wearing the Near Spectacle for the First Time (근용 안경을 최초 장용하는 노안에 대한 임상적 연구)

  • Yoo, Jong-Sook;Lim, Hyeon-Seon;Lee, Soo-Cheon;Hwang, Jung-Hee;Kim, Hyo-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.103-107
    • /
    • 2008
  • Purpose: This research measured the near addition powers of presbyopia in wearing the near spectacle for the first time. Methods: We evaluated age, sex, working group, spherical power and cylindrical power and measured the power of refractive error performed the both eyes (310 eyes) of 155 subjects subjectively noncycloplegic and power of addition using the cross cylinder method. Results: There were measured the near addition powers in the range of +0.75D ~ +1.75D. In case of the average addition, they were measured with +1.06D in subjects under 43 years of age, +1.08D in 44 to 46 years, +1.23D in 47 to 49 years and +1.46D in over 50 years of age. The average age in subjects was 47.6 years old and 74 male, 81 female, 71 near sighted working group and 83 far sighted working group. Conclusions: Near addition was correlated with age, working group and cylindrical power (P<0.05, P<0.05, P<0.05).

  • PDF

Clinical Efficacy of Bunny Multifocal Intraocular Lens after Cataract Surgery (버니 다초점인공수정체의 임상적 효용성)

  • Cho, Myung Ho;Park, Jae Yeong;Park, Byung Gun;Lee, Jong Soo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1129-1136
    • /
    • 2018
  • Purpose: To compare the postoperative clinical outcomes after cataract surgery and implantation using the BunnyLens $MF^{(R)}$ and $ReSTOR^{(R)}$ multifocal intraocular lenses. Methods: Sixty-five eyes implanted with multifocal intraocular lenses were divided into two groups involving either $ReSTOR^{(R)}$ (39 eyes) or BunnyLens $MF^{(R)}$ (26 eyes) lenses. In these two groups, the distant and near visual acuity, astigmatism, spherical equivalent, and contrast sensitivity test were examined at preoperative and postoperative 1 week, 8 weeks, and 24 weeks. We compared the clinical efficacy between the two groups before and after cataract surgery using statistical analysis. Results: The mean value of distant and near visual acuity, and spherical equivalent of both groups after intraocular lens implantation were significantly improved, compared with the preoperative values (p < 0.05), while there was no significant differences between the two groups (p > 0.05). The means of postoperative distant and near visual acuity, astigmatism, and contrast sensitivity test were not significantly different between $ReSTOR^{(R)}$ and BunnyLens $MF^{(R)}$ lenses (p > 0.05). The mean numeric error of spherical equivalent at the final postoperative 24 weeks was $-0.17{\pm}0.50$ diopters (D) for the $ReSTOR^{(R)}$ lenses and $-0.34{\pm}0.52D$ for the BunnyLens $MF^{(R)}$ lenses (p > 0.05). Conclusions: BunnyLens $MF^{(R)}$ and $ReSTOR^{(R)}$ lenses showed no significant difference in clinical efficacy, including distance and near vision, spherical equivalent error, and contrast sensitivity test after cataract surgery. However, it should be noted that BunnyLens $MF^{(R)}$ lenses had a tendency toward myopic shift compared with $ReSTOR^{(R)}$ lenses.

Correlations between Exophthalmetry and Visual Functions (안구돌출도와 시기능의 상관관계 분석)

  • Kim, Guenhei;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.325-331
    • /
    • 2015
  • Purpose: This study was to find the correlation between exophthalmetry and visual functions. Methods: Exophthalmetry and visual functions of 200 adults without ophthalmophathy and general disease were examined. Exophthalmetry were measured with Hertel's exophthalmometer. Visual functions (myopia, distance exophoria, near exophoria, near point of convergence, near point of accommodation) were measured for three times. Results: The exophthalmetry was $13.59{\pm}1.10mm$. Myopia, distance exophoria, near exophoria, near point convergence, and near point accommodation were measured as $-2.48{\pm}1.91D$, $3.51{\pm}1.78{\Delta}$, $5.73{\pm}2.44{\Delta}$, $9.63{\pm}2.82cm$, and $21.73{\pm}10.28cm$. With increasing exophthalmetry, the unaided visual acuity, myopia and astigmatism were decreased. On the other hand, distance exophoria, distance esophoria, near exophoria, near point of convergence and near point of accommodation were significantly increased, while exophthalmetry was increased. Conclusions: The relationship between visual functions and exophthalmetry were found to be statistically significant. It could be used as the clinical criteria for prescription of binocular inspections.