• Title/Summary/Keyword: 극한 해석

Search Result 1,002, Processing Time 0.029 seconds

Nonlinear Moment-Curvature Relations and Numerical Structural Analysis of High-Strength PSC Flexural Members (고강도 PSC 휨부재의 비선형 모멘트-곡률 관계와 전산구조해석)

  • 연정흠;이제일
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.95-104
    • /
    • 2002
  • A methods to calculate non-linear moment-curvature relations of high-strength PSC flexural members for numerical analysis has been proposed. The moment-curvature relations were calculated with assumptions of design codes and by the layer method. The results of the proposed procedures for moment-curvature relations and numerical analysis were compared with those of pre-existing tests. The absorption energy rate of the design codes was about 30% larger than that of the layer method. The ultimate load and the external work of the layer method were 90% and 85% of those of tests, respectively The ultimate load of the strength design method was 97% of that of tests, but the external work was over-estimated with 122%. The ultimate load and external work by the proposed equation of the CEB-FIP Model Code were 113% and 173% of those of tests, respectively. It show that the use of ultimate strain of 0.0035 should be over-estimated for high-strength concrete. The procedure of non-linear numerical analysis of this research could be stably simulated the behavior of concrete flexural members until the ultimate state, and calculate results of the load-deflection relation and cracking pattern were very similar with those of tests.

Bucking Behavior of Slender Reinforced High-Strength Concrete Columns (고강도 철근콘크리트 기둥의 좌굴 거동에 관한 연구)

  • 김진근;양주경
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.2
    • /
    • pp.129-139
    • /
    • 1993
  • 본 연구에서는 철근콘크리트 기둥의 거동을 예측하기 위하여 층상화 방법을 이용한 유한요소 해석방법이 제안되었다. 콘크리트의 강도와 철근비가 기둥의 극한강도와 거동에 미치는 영향을 규명하기 위하여 세장비가 10, 60, 100인 정방형 단면(80$\times$80mm)을 갖는 30개의 기둥에 대하여 실험을 수행하였다. 이때, 콘크리트의 강도는 25.5, 63.5, 86.2MPa로, 철근비는 1.98, 3.95%로 변화시켰다. 또한, 단부조건은 양단힌지로 하고, 편심량은 기둥은 양단에서 같은 방향으로 24mm로 동일하게 하였다. 본 연구에서 제안된 해석방법은 철근콘크리트 기둥의 거동을 잘 예측하며, ACI의 모멘트 확대계수법은 고강도 콘크리트 장주에 대해서는 안전측이 아닌 것으로 나타났다. 콘크리트의 강도가 기둥의 극한강도에 미치는 영향은 기둥의 세장비가 증가할수록 감소하였으며, 콘크리트의 강도가 커질수록 세장기둥의 좌굴파괴 가능성은 증가하였다. 또한, 철근비를 증가시킬 경우, 기둥의 축력이 최대가 될 때의 모멘트가 증가되었으며, 기둥의 극한강도 증가량은 단주보다는 장주에서 더 크게 나타났다. 철근비 증가에 의해 나타나는 이러한 기둥의 극한강도 증가량과 모멘트 증가량은 콘크리트의 강도가 커질수록 증대되었다.

Identification of Seismic Hysteretic Behavior of R/C Shear Walls (R/C 전단벽의 지진이력 거동에 관한 연구)

  • 오순택
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.2
    • /
    • pp.162-170
    • /
    • 1993
  • 축력과 횡력을 받는 전단벽의 휨과 전단 거동을 분리산정하기 위하여 R/C 전단벽에 관한 실험 결과에 대해 System Identification을 행한다. 이를 토대로, 전단벽의 강도 저하 계수 'R'과 극한 회전능력을 구하는 실험식을 제안한다. R/C뼈대구조-전단벽에 대한 비탄성 해석 유한요소 컴퓨터 프로그램(IDARC)을 이용하여 전단벽의 지진 이력 거동을 재현한다. Identification 결과를 Digitize한 실험 결과와의 비교에 의해 검증하고, 총변형으로부터 휨과 전단에 의한 변형요소를 해석적으로 분리 함으로서 비탄성 전단 거동과 강도 저하 계수 'R'의 산정이 가능해진다. 또한 실험 결과에 대한 회귀 분석을 통하여 전단벽의 극한 회전 능력에 대한 실험식이 얻어진다.

Design and characteristics analysis 4/2 and 6/4 SRM for high-speed air blower (고속 에어블로워용 4/2, 6/4 SRM 설계 및 특성 해석)

  • Ahn, Soo-yong;Lee, Dong-hee;Ahn, Jin-woo
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.201-202
    • /
    • 2017
  • 스위치드 릴럭턴스 전동기(Switched Reluctance Motor, 이하 SRM)은 간단한 구조와 기계적 강인성, 넓은 속도 범위를 사용할 수 있다는 장점이 있다. 하지만, SRM을 산업분야에 적용하기 위해서는 각각의 설계 변수에 따른 성능 변화에 대한 연구가 부족한 실정이며, 기기의 소형화에 대한 연구가 진행되어지고 있다. 본 논문에서는 2상 4/2극 SRM과 3상 6/4 SRM을 설계 하며, 2상 4/2극 SRM의 경우 스테퍼 회전자의 극호각과 스테퍼의 높이를 변수로 지정하여 성능을 확인하며, 3상 6/4극 SRM의 경우 2상 4/2 SRM 전동기 대비 기기의 소형화를 중점으로 설계 및 특성 해석을 수행하였다.

  • PDF

Limit Analysis of Axisymmetric Forward Extrusion (축 대칭 전방 압출의 극한 해석)

  • Kim, Byung-Min;Choi, In-Keun;Choi, Jae-Chan;Lee, Jong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.8 no.3
    • /
    • pp.93-104
    • /
    • 1991
  • Limit analysis is based on the duality theorem which equates the least upper bound to the greatest lower bound. In this study, limit analysis of axisymmetric forming problem with workhardening materials is formulated by minimizing the upper bound functional and finite element program is developed for forward estrusion. Limit loads, velocity and flow line fields are directly obtained under various process conditions and deformation characteristics such as strains, strain rates and grid distortion are obtained from the optimum velocity components by numerical calculation. The experimental observation was carried out for extrusion and compared with computed results. The good agreement between theoretical and experimental results is shown that the developed programming is very effective for the analysis of axisymmetric extrusion.

  • PDF

추계학적 시강우모의 기법을 이용한 극한강우 발생 및 시간단위 설계강우량 산정기법에 대한 평가

  • Lee, Jung-Ki;Kim, Byung-Sik;Jun, Byong-Hee;Kim, Hung-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.344-344
    • /
    • 2012
  • 추계학적 강우모의발생기법은 수문학적 분석에 널리 이용되는 방법으로서 장기간의 강우입력 자료를 이용할 수 없는 경우 과거의 관측 자료를 반복하여 이용하기 보다는 과거 관측치의 통계학적 특성을 지니고 있는 합성강우량 시계열자료를 모의하여 설계 강우량 산정 및 강우-유출모형을 이용한 장기해석 등과 같은 수문학적 해석을 위한 입력 자료를 확충하기 위해 이용된다. 그러나 최근 기후변화로 인해 수문학적 설계 강우량 산정 시 가장 중요한 강우발생 특성과 극한치의 특성이 변화하고 있기 때문에 전통적인 추계학적 강우발생기법을 이용하여 강우 시계열자료를 확충하는 것은 한계가 있을 것으로 추정되고 있다. 이에 본 논문에서는 최근 유럽 등에서 도시배수체계의 설계를 위해 널리 이용되고 있는 Bartlett-Lewis rectangular pulse 모형을 이용하여 시간단위 강수량자료를 확충하고 모의된 강우량시계열자료와 실측 강우량자료를 통계학적으로 비교하였다. 또한, 극한치 분석을 통해 변화하는 기후상황에서 적합한지를 평가하였다.

  • PDF

햅틱으로 작동되는 등반 로봇의 센싱 시스템 설계와 토크 해석

  • 김철수;윤상석;김용대;박기환;최창환;김승호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.196-196
    • /
    • 2004
  • 원자로의 원자로 해체 처리나 테러리스트의 폭탄 제거와 같은 극한 환경에서 작동하는 로봇은 계단이나 구덩이 같은 평평하지 알은 지형을 극복하기 위해서 off-load 능력이 필요하다. 극한 환경에서의 작업은 전형적으로 원격으로 조정되는 로봇을 요구한다. 본 논문에서는 향상된 관절 트랙 구조의 로봇을 제안한다. 로봇이 계단에 접촉할 때론 고려해서 조이스틱으로 햅틱 동작을 위한 센싱 시스템이 제안된다. 추가적으로, 제안된 로봇이 계단을 등반하는 알고리즘을 제안한다.(중략)

  • PDF

Behavior and Ultimate Strength of Restrained Reinforced Concrete Columns (구속 철근콘크리트 기둥의 극한강도와 거동해석)

  • Park, Jae Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.23-31
    • /
    • 1992
  • In this study, Behavior of Eccentrically Loaded Restrained Concrete Slender Columns are investigated the continuation. The paper is : nonlinear constitutive relations of reinforced concrete columns are formulated, the multivariable nonlinear equation formulated in this study is solved by the incremental iterative method, the solution scheme is suitable for computer application, the proposed method bas been compared with the numerical examples and other research results and is shown to be in good agreement Accordingly, the objectives of this investigation are to use the method developed to conduct a parametric study of the different variable (Rotational Restraints,Ratio of End Restraints. End Eccentricity, Ratio of End Eccentricities,Lateral Restraint, Concrete Strength, Ratio of Reinforcement. Yield Point of Reinforcement) influencing the behavior and the ultimate strength for columns. Chosen values for different parameters and their variations are based on values encountered in practice and on results of other analylitical studies.

  • PDF

Characteristic Analysis of Outer-Rotor Type SRM for Washing Machines (세탁기용 외전형 SRM의 특성해석)

  • Park, Bo-Ryang;Kim, A-Ran;Ahn, Jin-Woo;Lee, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.531-532
    • /
    • 2011
  • 본 논문에서는 세탁기의 DD Moter로 사용되고 있는 BLDCM을 대신하여 세탁기의 부하에 따른 세탁모드와 탈수모드의 특징에 만족시키는 외전형 SRM을 설계하였다. 이와 같은 특징을 고려하여 외전형 SRM의 극 조합으로 12/8, 18/12, 36/24 극에 대해 설계하고 유한요소해석법을 통해 외전형 SRM의 특성을 해석하였다. 본 논문에서는 세탁기용 전동기에 알맞은 구조로 18/12극이 적절한 것으로 평가되었다.

  • PDF

Assessment of the Internal Pressure Fragility of the Wolsung Unit 1 Containment Building using Nonlinear Finite Element Analysis (비선형 유한요소 해석을 이용한 월성1호기 격납건물의 내압취약도 평가)

  • Hahm, Dae-Gi;Choi, In-Kil;Lee, Hong-Pyo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.653-656
    • /
    • 2010
  • 월성 1호기 격납건물에 대하여 극한내압하중에 대한 확률론적 취약도 평가를 수행하였다. 격납건물 성능의 불확실성은 가동중 검사 결과를 통해 얻어진 재료 물성치 중앙값과 텐던 긴장력 중앙값을 적용하여 고려하였다. 격납건물은 개구부를 고려하여 3차원 유한요소로 모델링하였으며, 확률론적 취약도 평가를 위하여 대규모의 비선형 유한요소 해석 모델을 적용하기에 적합한 효율적인 취약도 평가 기법을 개발하였다. 월성 1호기 격납건물에 대한 취약도 평가 결과, 벽체 중단부가 극한내압발생으로 인한 방사능물질 누출에 가장 취약한 것으로 나타났으며, 중앙값 성능은 약 55psi, 고신뢰도 저파괴 파괴확률값인 HCLPF(High Confidence Low Probability of Failure)는 약 29psi를 나타내었다.

  • PDF