• Title/Summary/Keyword: 극저온 블로워

Search Result 5, Processing Time 0.022 seconds

Design and Performance Test of a Cryogenic Blower for Space Thermal Environment Simulation (우주 열환경 모사용 소형 극저온 블로워 설계 및 성능평가)

  • Seo, Heejun;Ahn, Sungmin;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.833-839
    • /
    • 2013
  • Thermal vacuum test should be performed prior to launch to verify satellites' functionality in a harsh space environment which is represented by extremely cold temperatures and vacuum conditions. A thermal vacuum chamber which consists of a vacuum vessel, a pumping system, and a thermal control system are used to perform thermal vacuum tests of a satellite system and its components. A cryogenic blower is a core component of the closed loop thermal control system for thermal vacuum chambers. This paper describes the fan design of the cryogenic blower, the design of the thermal protection interface between the driving part and the fluid part, which were verified by thermal and structural analyses. The performance of the cryogenic blower is confirmed by similarity test on the test bench.

열진공 챔버용 열제어 시스템 이중화 개념 설계

  • Seo, Hui-Jun;Heo, Hwan-Il
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.120.1-120.1
    • /
    • 2013
  • 우주 궤도환경은 $10^{-5}$ torr 이하의 고진공 및 $100^{\circ}C$의 고온과 $150^{\circ}C$이하의 극저온 환경으로 특징지어지며, 위성체 및 위성체 부품은 이와 같은 우주 궤도환경에서의 성능검증이 필수적이다. 지상에서 이와 같은 환경을 모사하기 위해서는 열진공챔버가 사용되며, 열진공 챔버는 진공배기계와 열제어 시스템으로 구성된다. 특히 위성체 또는 위성부품의 열환경을 모사하기 위해 기체 질소를 이용한 폐회로 열제어 시스템이 사용된다. 폐회로 열제어 시스템은 슈라우드, 극저온 블로워, 히터 등으로 구성이 된다. 열제어 시스템의 신뢰성을 높이기 위해서는 핵심 부품인 극저온 블로워의 이중화가 필요하다. 본 논문에서는 위성체 및 위성체 부품의 열진공 시험에 사용되는 열진공 챔버 열제어 시스템의 핵심인 극저온 블로워의 이중화를 위한 기구 설계 및 제어로직 설계 등이 포함되어 있다.

  • PDF

Design and Performance Tests of a Cryogenic Blower for a Thermal Vacuum Chamber (열진공 챔버용 극저온 블로워 설계 및 성능평가)

  • Seo, Heejun;Cho, Hyokjin;Park, Sungwook;Moon, Gueewon;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.11
    • /
    • pp.1008-1015
    • /
    • 2015
  • Thermal vacuum test should be performed prior to launch to verify satellites' functionality in extremely cold/hot temperatures and vacuum conditions. A thermal vacuum chamber used to perform the thermal vacuum tests of a satellite system and its components. A cryogenic blower is a core component of the gaseous nitrogen (GN2) closed loop thermal control system for thermal vacuum chambers. A final goal of this research is development of cryogenic blower. Design requirements of a blower are 150 CFM flow rate, 0.5 bara pressure difference, hot and cold temperatures. This paper describes the performance analysis of impeller by 1D, CFD commercial software, the design of the thermal protection interface between the driving part and the fluid part. The performance of the cryogenic blower is confirmed by test at the standard air condition and is verified by on the thermal vacuum chamber at the real operating condition.

Design and Performance Test of a Closed Loop Thermal Control System for Thermal Vacuum Chamber (열진공 챔버용 폐회로 열제어시스템 설계 및 성능평가)

  • Seo, Heejun;Cho, Hyokjin;Park, Sungwook;Moon, Gueewon;Jung, Sanghun;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.88-97
    • /
    • 2016
  • A closed loop thermal control system simulates space thermal environment to verify the satellites' functionality in extremely cold/hot temperature. It is composed of a cryogenic blower, thermal shroud, heater, cryogenic valves. This paper presents an overview of closed loop thermal control system's design parameter and test results for control parameter. A capacity of blower is calculated through energy balance equation and an advantage/disadvantage for a shroud material and a type was analysed. The thermal control system is controlled by a constant density of fluid in the system. A requested performance of closed loop thermal control system was verified by measuring a homogeneity and stability of shroud through control parameter such as density and RPM of blower.

입구 압력에 따른 열진공 시험용 베이스플레이트의 열유동 특성에 관한 수치해석적 연구

  • Go, Tae-Sik;Seo, Hui-Jun;Jo, Hyeok-Jin;Park, Seong-Uk;Im, Seong-Jin;Mun, Gwi-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.140.2-140.2
    • /
    • 2014
  • 인공위성은 우주공간의 고진공 상태와 태양 복사열에 의한 고온 및 극저온이 반복되는 가혹한 환경으로 인해 주요 부품의 기능장애가 초래되므로 발사전 지상에서 열진공 시험장비를 이용한 열진공시험을 수행한다. 위성체의 열진공 시험에 사용되는 열교환기인 베이스플레이트(Baseplate)는 우주 열환경을 모사하기 위하여 직접 방열판 표면에 고온 및 저온의 유체를 공급하여 시험 요구에 따른 필요한 열을 공급하게 된다. 일반적으로 우수한 성능의 위성체 부품의 검증을 위해서 지상의 열환경 시험은 접촉식 히터 및 열교환기를 사용하게 되는데, 이때 적절한 히터 및 블로워 파워를 선정하고 챔버 슈라우드와 열교환에 있어 간섭이 없도록 장비를 운용해야 한다. 본 연구에서는 상용프로그램을 이용하여 열진공 시험용 베이스플레이트에 대하여 전산해석을 수행하였으며, 이를 통해 베이스플레이트 내의 작동 유체의 입구 압력에 의한 열진공 시험용 열교환기의 성능 특성을 관찰하였다.

  • PDF