• Title/Summary/Keyword: 균열특성

Search Result 2,077, Processing Time 0.034 seconds

Static Behavior of Steel-Concrete Composite Beam with Perfobond Rib Shear Connector (Perfobond rib 전단연결재가 설치된 강.콘크리트 합성보의 정적거동)

  • Ahn, Jin Hee;Chung, Hamin;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.4
    • /
    • pp.421-432
    • /
    • 2009
  • In this study, push-out and static loading tests were conducted to evaluate the behavioral characteristics of composite beams with a perfobond rib shear connector. The shear capacity of the perfobond rib was found to be proportional to its concrete strength, which is in turn affected by the increase in the concrete end-bearing strength and concrete dowel action to resist the shear force. The relative slips of the push-out specimen, however, which was used to assess the ductility of the shear connector, increased to some extent, but it no longer increased when it reached the critical concrete strength because of the flexibility of the transverse rebar in the rib hole. The static-loading-test results revealed a crack on the concrete slab in the composite beam with a perfobond rib on the side of the rib hole and transverse rebar for the applied moment and shear force to the rib hole, depending on the static loading. The shear resistance characteristics of the perfobond rib shear connector were found to resist the shear force from the relative slip on the interface of the composite beam. Thus, the sectional effect of the shear connector to the composite beam with a perfobond rib should be considered when designing the composite beam because the behavior of the composite beam can change owing to the shear connector.

Crushing Characteristics of Single Particle of Recycled Aggregate from Waste Concrete (폐콘크리트 순환골재의 단입자 파쇄 특성)

  • Park, Sung-Sik;Kim, Sang-Jung;Moon, Hong-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.12
    • /
    • pp.23-32
    • /
    • 2016
  • A single particle crushing test was carried out for recycled aggregates from waste concrete while demolishing various structures. When the recycled aggregates were used for backfill or road subbase materials, load-displacement and crushing characteristics were analyzed. The recycled aggregates with hydrates and aggregates were sorted into 40 mm size (75-40 mm) and 20 mm size (40-20 mm). At initial loading, their irregular surface was closed to and then crushed by loading plate. Such first crushing stage was called 'Surface crushing'. Further loading, some hydrate was crushed and detached from aggregate, and such process repeated several times. This state is called 'hydrate crushing'. The final state is called 'aggregate crushing' in which aggregate crushed and following load suddenly dropped down. As the load increased, such crushing cycle is repeated several times. The shapes of aggregates are round or square, and triangle or long shaped. Depending on their shapes and surface conditions, they crushed in different ways. The 63% of aggregates showed more than 50% load reduction due to aggregate crushing. The 90% load reduction occurred at 15% of aggregates. The 40 mm aggregate crushed at maximum load between 3.05-4.38 kN and 70% of crushed aggregates were less than 20 mm.

Transport Coefficients and Effect of Corrosion Resistance for SFRC (강섬유 보강 콘크리트의 수송계수 및 부식저항효과)

  • Kim, Byoung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.867-873
    • /
    • 2010
  • This study investigated the corrosion properties of reinforced concrete with the addition of steel fibers. The transport properties of steel fiber-reinforced concrete such as permeable void, absorption by capillary action, water permeability and chloride diffusion were first measured to evaluate the relationship with the corrosion of steel rebar. Test results showed a slight increase on the compressive strength with the addition of steel fibers as well as considerable improvement of penetration resistance to mass transport of harmful materials into concrete. The addition of steel fibers in reinforced concrete accelerated the initiation of steel corrosion contrary to the expected results based on the measured transport properties. The NaCl ponding surface showed the spalling failure due to the corrosion expansion of steel fibers and the cut-surface around the steel rebar showed the localized steel fiber's corrosion. The wet-dry cycling with high chloride ions as well as high temperature seems to induce the increase of salt crystallization on the pores continually and the increased pressure with the steel fiber's corrosion on the pores caused the spalling failure on the exposed surface. The microcracking on the surface therefore accelerated the movement of water, chloride ions and oxygen into the embedded steel rebar. The mechanism affecting corrosion of embedded steel reinforcement with steel fibers in this study are not yet fully understood and require further study comprising of accurate experimental design to isolate the effect of steel fiber's potential mechanism on the corrosion process.

DEM estimation of mechanical properties of conglomeratic rocks (역암의 역학적 거동 특성 파악을 위한 개별요소법의 응용)

  • Park, Young-Do;Yoo, Seung-Hak;Kim, Ki-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.42-50
    • /
    • 2006
  • 역들의 공간적 분포가 불균질하고 역의 크기가 큰 역암의 경우 암석 전체를 대표하는 물성치($E_m,\;c,\;\Phi$ 등) 구하기 위해서는 매우 큰 시험기기가 필요하다. 따라서 커다란 역을 포함하는 역암의 경우 직접 암석실내시험을 통한 물성치 산정은 현실적으로 거의 불가능하다. 이러한 문제를 극복하기 위하여 이 연구에서는 개별요소법을 이용하여 역암의 물성치를 산출하는 방법을 제안한다. 그 방법은다음과 같다. (1) 역암내의 역의 물성과 기질부의 물성을 각각 실내실험을 통하여 파악한 후 이들 (2) 두 물질의 거동양상을 구현할 수 있는 개별요소집합체의 개별요소간의 물성을 결정한다. (3) 역의 함량, 크기 모양 공간적 분포양상등의 역암 조직과 유사한 개별요소 수치해석시료를 만든 후, (4) 이를 수치 해석실험 (이축압축실험)에 사용한다. 이러한 수치해석실험을 통해 현재까지 만들어진 결과는 다음과 같다. 첫째, 역의 강도가 기질의 강도보다 높은 역암의 경우, 역의 양이 증가할수록 일축압축강도, 내부 마찰각, 점착력이 증가하지만 증가 양상은 선형이 아니다. 탄성계수의 경우 역의 양과 상관 없이 변화하지 않는다. 둘째, 역과 기질 사이 표면의 점착력이 약할 경우 이러한 표면에서 최초 미세 균열이 형성되기 시작하므로 이 점착력은 물성치를 산출하는 중요한 인자이다. 따라서, 향후 이에 대한 자세한 연구가 필요하다고 판단된다. 결론적으로,설계 또는 시공시 직접시험에 의한 물성치의 파악이 어려운 역암 또는 직접시험을 위해 대량의 시료를 필요로 하는 함력 미고결지층, 핵석층, 풍화암과 같은 시료의 물성치는 별도로 측정된 물성들 (예, 역과 기질)을 이용한 개별요소법을 통해 구할 수 있다.로 나타났다.TEX>, DIN/DIP비 표층수 $23.91\pm3.42$, 저층수 $23.43\pm3.38$이었으며, 전반적으로 해역별 수질기준 I등급 내지는 II등급을 유지하고 있었고, 공간적으로는 외해측으로 갈수록 외해수와 혼합 확산되어 양호한 수질을 나타내었다. 장기적인 변동특성은 세그룹으로 구분되어진다.기 실험결과 용출용매로 증류수와 해수를 이용했을 때, 제강 슬래그에서 용출되는 납, 구리, 카드뮴, 수은의 용출 경향의 차이를 확인할 수 있었고 이에 따라서, 납, 구리, 카드뮴의 용출 유해성은 낮기 때문에 해양구조물로의 제강슬래그 유효이용은 적합할 것으로 판단되었다.im80%$로 계산되었다. 열형광선량계로 측정된 방사선량은 각각 1.8, 1.2, 0.8, 1.2, 0.8 (70 cm 거리) cGy로 측정되었으며, 환자의 복부 표면에서의 서베이메터를 이용한 측정량은 10.9 mR/h였다. 차폐구조물의 사용 시 전체 치료 동안에 태아선량은 약 1 cGy 정도로 평가되었다. 결론 : AAPM Report No.50의 자료에 따르면, 임산부의 방사선 치료 시 태아의 방사선 피폭선량은 5 cGy 이하일 경우에 방사선 피폭에 따른 태아의 위험이 거의 없는 것으로 제시되고 있다. 본원에서 차폐 구조물을 설치하였을 경우에 측정된 태아선량은 약 1 cGy로 측정되었고, 고안된 차폐구조물은 태아에 도달하는 방사선량을 감소시키기에 적합한 설계임이 입증되었다. 아니라 일반종합병원에서도 CTX-M형 ESBL 생성 E. coli와 K. pneumoniae가 존재하며 확산 중임을 시사한다. 앞으로 CTX-M형 ESBL의 만연과 변종 CTX-M형 ESBL의 출연을 감시하기 위한

  • PDF

A Study on the Penetration Resistance and Spalling Properties of High Strength Concrete by Impact of High Velocity Projectile (고속비상체의 충돌에 의한 고강도 콘크리트의 표면관입저항성 및 배면박리성상에 관한 연구)

  • Kim, Hong-Seop;Nam, Jeong-Soo;Hwang, Heon-Kyu;Jeon, Joong-Kyu;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.99-106
    • /
    • 2013
  • Concrete materials subjected to impact by high velocity projectiles exhibit responses that differ from those when they are under static loading. Projectiles generate localized effects characterized by penetration of front, spalling of rear and perforation as well as more widespread crack propagation. The magnitude of damage depends on a variety of factors such as material properties of the projectile, impact velocity, the mass and geometry as well as the material properties of concrete specimen size and thickness, reinforcement materials type and method of the concrete target. In this study, penetration depth of front, spalling thickness of rear and effect of spalling suppression of concrete by fiber reinforcement was evaluated according to compressive strength of concrete. As a result, it was similar to results of the modified NDRC formula and US ACE formula that the more compressive strength is increased, the penetration depth of front is suppressed. On the other hand, the increase in compressive strength of concrete does not affect spalling of rear suppression. Spalling of rear is controlled by the increase of flexural, tensile strength and deformation capacity.

The Development of Multi-channel Electrical Conductivity Monitoring System and its Application in the Coastal Aquifer (다채널 전기전도도 모니터링 시스템의 개발과 연안지역 공내수 모니터링에 대한 적용 사례)

  • Shin, Je-Hyun;Hwang, Se-Ho;Park, Kwon-Gyu;Park, Yun-Seong;Byun, Joong-Moo
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.156-162
    • /
    • 2005
  • Particularly in research related to seawater intrusion the change of fluid electrical conductivity is one of major concerns, and effective monitoring can help to optimize a water pumping performance in coastal areas. Special considerations should be given to the mounting of sensors at proper depth during the monitoring design since the vertical distribution of fluid electrical conductivity is sensitive to the characteristics of seawater intrusion zone. This tells us the multi-channel electrical conductivity monitoring is of paramount consequence. It, however, is a rare event when this approach becomes routinely available in that commonly used commercial stand-alone type sensors are very expensive and inadequate for a long term monitoring of electrical conductivity or water level due to their restricted storage and difficulty of real-time control. For this reason, we have developed a real-time monitoring system that could meet these requirements. This system is user friendly, cost-effective, and easy to control measurement parameters - sampling interval, acquisition range, and others. And this devised system has been utilized for the electrical conductivity monitoring in boreholes, Yeonggwang-gun, Korea. Monitoring has been consecutively executed for 24 hours, and the responses of electrical conductivity at some channels have been regularly increased or decreased while pumping up water. It, with well logging data implemented before/after pumping water, verifies that electrical conductivity changes in the specified depths originate from fluid movements through sand layer or permeable fractured rock. Eventually, the multi-channel electrical conductivity monitoring system makes an effective key to secure groundwater resources in coastal areas.

Effect of Furrow Irrigation on the Growth and Quality of Panax Ginseng Plant in a Loam (고랑관수에 의한 수분공급이 인삼의 생육에 미치는 영향)

  • Park, Chol-Soo;Kang, Je-Yong;Lee, Dong-Yun;Ahn, Dae-Jin
    • Journal of Ginseng Research
    • /
    • v.32 no.4
    • /
    • pp.279-282
    • /
    • 2008
  • This study was conducted to compare the aerial parts growth, yield of fresh ginseng roots, quality of red ginseng roots, and photosynthesis (Fv/Fm, PSII) in leaves between non-irrigation plot and furrow irrigation plot during the ginseng growing seasons. The aerial part growth in furrow irrigation plot was higher than non-irrigation plot in all including the emergency rate, leafing rate and relatively growth rate. Root yield per 10a in irrigation plot was increased about 50% as compared with that of non-irrigation, also heaven and earth grade of red ginseng roots yield in irrigation plot was higher (40.3%) compared with that (30.6%) of non-irrigation plot in 6-years-old ginseng plant. Furrow irrigation markedly improved the ginseng quality and yield in comparison to non irrigation condition. Therefore it needs to control the soil moisture during the growing season for high yield and good qualities of ginseng roots.

Use of a Temperature as a Tracer to Study Stream-groundwater Exchange in the Hyporheic Zone (열추적자를 이용한 지하수-하천수 혼합대 연구)

  • Kim, Kue-Young;Chon, Chul-Min;Kim, Tae-Hee;Oh, Jun-Ho;Jeoung, Jae-Hoon;Park, Seung-Ki
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.525-535
    • /
    • 2006
  • A study on stream-groundwater exchange was performed using head and temperature data of stream water, streambed, and groundwater. Groundwater level and temperature were obtained from multi-depth monitoring wells in small-scale watershed. During the summer and winter season, time series of temperature data at streambed and groundwater were monitored for six months. In the winter time, we measured the temperature gradient between stream water and streambed. The observed data showed three typical types of temperature characteristics. First, the temperature of streambed was lower than that of stream water; second, the temperature of streambed and stream water was similar; and the last, the temperature of streambed was higher than that of stream water. The interconnections between the stream and the streambed were not homogeneously distributed due to weakly developed sediments and heterogeneous bedrock exposed as bed of the stream. The temperature data may be used in formal solutions of the inverse problems to estimate groundwater flow and hydraulic conductivity.

Hybrid Powder-Extrusion Process Involving the Control of Temperature Dwelling Time for Fabricating Spur Gears with Required Properties (온도 유지시간 제어를 적용한 하이브리드 분말 압출 공정을 통한 요구 특성의 스퍼기어 제조)

  • Lee, Kyung-Hun;Hwang, Dae-Won;Kim, Byung-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.8
    • /
    • pp.847-853
    • /
    • 2011
  • In this study, a hybrid powder-extrusion process involving the control of temperature dwelling time for improving the formability of Zn-22Al powder was developed and the effect of dwelling time on the mechanical properties of a spur gear with a pitch circle having a diameter of 1.8 mm was investigated. General extrusion experiments were carried out at different temperatures such as 290, 300, and $310^{\circ}C$. Spur gears with good qualities and without any surface defects were obtained in the case of extrusion temperature of $310^{\circ}C$ and ball-milling duration of 32 h. The Vickers hardness distribution was non-uniform, and after the sintering process, an internal crack was generated because of the different deformation energy between gear central part and teeth. To overcome the abovementioned problems, research on controlling the dwelling time of the extrusion temperature in the powder-extrusion process was carried out. Good-quality spur gears were obtained when the dwelling time was 15 min.

Material Characteristics and Conservation Treatment for Floral Wall in Lee Sang-beom's House and Atelier (이상범 가옥 및 화실 내 꽃담의 재료학적 특성과 보존처리)

  • Kim, So-Jin;Han, Min-Su;Lee, Won-Dong;Han, Byoung-Il
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.313-322
    • /
    • 2011
  • The floral wall of Lee Sang-beom's House and Atelier, which is No. 171 of the Registrated Cultural Heritage was conserved. In addition, materials characteristics and manufacturing technique have revealed through the scientific analysis. As a result of the analysis, samples were divided into three sections; the support layer that is made from block bricks, the paint layer and the cement mortar layer on the paint layer for the reinforcement of the construction. The higher layer lies, the finer grains it has. Furthermore, a little it was generated a small quantity of pores and calcium carbonates ($CaCO_3$) generated due to aeration of cement mortar. The patterns of letters, animals and plants pattern were expressed in the paint layer by relief and openwork. The results of qualitative analysis of the pigments of the paint layer were detected components of carbon black (C), Fe oxide ($Fe_2O_3$) and oyster shell white ($CaCO_3$, or quicklime). On the other hands, as the conservation of the floral wall, stainless frames were set up for the structural stability, the cement mortar were removed from the surface and the partly damaged and cracked areas were filled with KSE Filler A, B.