• Title/Summary/Keyword: 굴절성능

Search Result 147, Processing Time 0.029 seconds

Improvement of the performance of SPPCM using mixed polarized beam and cylindrical lens (혼합 편광빔과 원주면렌즈를 사용한 SPPCM의 성능 개선)

  • Yi, Eun-Hyeong;Kim, Seong-Wan;Kim, Cheol-Su;Kim, Jong-Yun;Lee, Seung-Hee;Lee, Soo-Joong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.56-63
    • /
    • 1999
  • Conventional method to improve the response time of the Cat-SPPCM was to increase fanning beam using cylindrical lens. But, in this case the temporal instability of this SPPCM is increased, and fanning beam plays a role as noise, so that it decreases the reflectivity. Thus, fanning beam must be controlled to improve the properties of SPPCM. In this paper, we propose the method to increase the reflectivity of SPPCM and decrease the response time by focusing line-shaped input beam into photorefractive crystal using cylindrical lens and decrease the temporal instability of output beam by using mixed-polarized beam instead of simple extraordinary polarized beam. Optical experiments show that the reflectivity of proposed SPPCM is increased twice and the response time is reduced by 15 times. Also, we observed that the temporal instability of SPPCM is reduced when the polarization angle of the mixed-polarized beam is between $10^{\circ}$ and $30^{\circ}$ . We used a $45^{\circ}-cut\;BaTiO_3$ crystal which has high electro-optical coefficients in optical experiments.

  • PDF

Design of Aspheric Imaging Optical System having 24mm Focal Length for MWIR with Facing Symmetric Lenses (마주보는 대칭렌즈를 가지는 MWIR용 초점거리 24mm의 비구면 결상광학계 설계)

  • Lee, Sang-Kil;Kim, Boo-Tae;Lee, Dong-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.183-189
    • /
    • 2018
  • This study deals with the design and development of imaging optics having 24mm focal length for MWIR ($3{\sim}5{\mu}m$) with two symmetrical lenses facing each other. We used CodeV in our optical design, and we performed the optimization process to have the resolution and angle of view satisfying the user's requirements. The materials of lenses were limited to two types, including KCIR035 with a refractive index of 1.7589, developed in Korea. The optical system designed in this way consists of two aspherical lenses made of KCIR035 material having the same shape and one spherical lens made of Si. Here, the arrangement of the two aspherical lenses is characterized by having a symmetrical structure facing each other. And this optical system has a resolution of MTF value of 0.35 or more at a line width of 20 lp / mm. Therefore, it is considered that this optical system has the capability to be applied to a thermal imaging camera using a $206{\times}156$ array MWIR detection device having a pixel size of $25{\mu}m$.

A Comparative Study on the Local Transmittance Homogeneity of the Ocular Lens (안경 렌즈의 국소적 투과율 균일도 비교 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Jang, Yun-Seog;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.471-476
    • /
    • 2015
  • Purpose: We have analyzed the transmittance distribution of various ocular lenses using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The local transmittance of the laser which is focused on the surface of the spectacle lens was measured by using the photo-detector, lock-in amplifier and motorized-stage. 25 multi-coated lenses with non-tinted of 5 groups and 45 multicoated lenses with tinted of 9 groups were analyzed as a sample respectively. Results: Average and deviation of local transmittance for nontinted lenses were measured almost uniformly with various refractive index and coating. However, deviation of transmittance of for tinted lenses was analyzed as about 3.7 times larger than that of non-tinted lenses. Inhomogeneity of local transmittance of for tinted lenses was also analyzed as about 3.1 times larger than that of non-tinted lenses. Conclusions: We could analyze that standard deviation of transmittance and inhomogeneity of local transmittance of for tinted lenses is larger than that of non-tinted lenses using the local transmittance microscope. These analysis using local transmittance microscope can be utilized as a way to evaluate lens performance and improve optical homogeneity.

Elli-Situ 2000 (in situ, 실시간 표면 및 박막 모니터 장비)

  • 방현용;주한용
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.46-46
    • /
    • 2000
  • 과학기술 및 산업의 발달로 인하여 실험 중 또는 공정 상에서 in situ, 실시간으로 측정하고 분석하며 이를 되먹임하는 품질제어의 중요성이 대두되고 있다. 반도체 공정 또는 박막제조 공정 중에서 박막의 두께, 굴절율, 물질의 조성비 등을 알아내는 것이 긴요한 과제로 대두되고 있으며, 이를 위하여 공정중인 제품의 품질을 실시간으로 평가하는 장비가 요구되고 있는 것이다. 나아가 공정중의 예상하지 못한 시료의 특성변화를 그대로 감지하여 적절히 보정해 주는 되먹임 기법은 높은 수율을 보장하는 첨단기법이라 할 수 있다. 이러한요구에 부응할 수 있는 본 제품(Elli-situ 2000)은 박막의 두께 표면변화를 sub 의 정밀도를 가지고 in situ, 실시간으로 정밀 측정할 수 있는 첨단 계측장비로서 빛의 편광상태 변화를 측정하기 때문에 공정 중의 시료에 영향을 주지 않는 비간섭 특성과 비접촉 특성의 장점 뿐만 아니라 공기중에서는 물론 진공이나 액체 등의 매질에서도 사용될 수 있어서 매질에 대한 제약이 거의 없다는 장점도 가지고 있다. 편광상태의 제어 및 측정을 필요한 광학장비의 경우, 제작이 까다롭기 때문에 대부분 가격이 높은 편이고 사용방법이나 측정 데이터에 대한 해석이 어렵다는 단점이 있으나, Elli-situ 2000의 경우 상용화된 외국제품(국내제품은 없슴)과 비교하여 성능 및 가격경쟁력에 있어서도 우위에 있으며 간단, 명료한 장비조작 및 컴퓨터를 사용한 구동의 전자동화를 이룸으로써 초보자도 쉽게 측정하고 데이터를 처리할 수 있도록 하였다. 또한 취부대의 경우, 진공포트 플랜지의 표준규격(2-3" Del-Seal 플랜지 규격)에 맞춤으로써 기존의 진공챔버에 부착하여 진공에 전혀 영향을 주지 않는 상태에서 시료의 변화를 in situ, 실시간으로 정밀 측정할 수 있도록 하였다. 하였다.O 박막은 산소 가스압력과 기판온도, 인가 전류를 변화시켜가며 증착하였으며 이에 따른 박막의 결정성 변화를 알아보았다. 기판온도를 실온에서 점차 증가시켜나가면 $\Delta$$\theta$50은 급격히 감소하며 30$0^{\circ}C$에서는 결정성이 우수한 막을 얻을 수 있었다. 또한 산소 가스 압력이 0.5~1mTorr에서 $\Delta$$\theta$50은 양호한 값을 나타내었지만 그 이상에서는 c-축 배향성이 나빠짐을 확인하였다. 따라서 대향타겟식스퍼터 장치를 이용하여 ZnO 박막을 증착시 가스압력 0.5~1mTorr, 기판온도 20$0^{\circ}C$이상의 막 제작조건에서 결정성이 우수하게 나타나는 것을 확인할 수 있었다. gluten이 단단해졌음을 알수 있었다. 유화제 stearly 칼슘, 혹은 hemicellulase를 amarans 10% 대체한 밀가루에 첨가하면 확연히 비용적을 증대시킬 수 있다는 사실을 알 수 있었다. quinoa는 명아주과 Chenopodium에 속하고 페루, 볼리비아 등의 고산지에서 재배 되어지는 것을 시료로 사용하였다. quinoa 분말은 중량의 5-20%을 quinoa를 대체하고 더욱이 분말중량에 대하여 0-200ppm의 lipase를 lipid(밀가루의 2-3배)에 대하여 품질개량제로서 이용했다. 그 결과 quinoa 대량 7.5%에서 비용적, gas cell이 가장 긍정적 결과를 산출했고 반죽의 조직구조가 강화되었다. 또 quinoa 대체에 의해 전분-지질 복합제의 흡열량이 증대된 것으로부터 전분-지질복합제의 형성 촉진이 시사되었다.이것으로 인하여 호화억제에 의한 노화 방지효과가 기대되었지만 실제로 빵의 노화는 현저히 진행되었다. 이것은

  • PDF

Effect of SPR Chip with Nano-structured Surface on Sensitivity in SPR Sensor (나노형상을 가진 표면플라즈몬공명 센서칩의 감도 개선 효과)

  • Cho, Yong-Jin;Kim, Chul-Jin;Kim, Namsoo;Kim, Chong-Tai;Kim, Tae-Eun;Kim, Hyo-Sop;Kim, Jae-Ho
    • Food Engineering Progress
    • /
    • v.14 no.1
    • /
    • pp.49-53
    • /
    • 2010
  • Surface plasmon resonance (SPR) which is utilized in thin film refractometry-based sensors has been concerned on measurement of physical, chemical and biological quantities because of its high sensitivity and label-free feature. In this paper, an application of SPR to detection of alcohol content in wine and liquor was investigated. The result showed that SPR sensor had high potential to evaluate alcohol content. Nevertheless, food industry may need SPR sensor with higher sensitivity. Herein, we introduced a nano-technique into fabrication of SPR chip to enhance SPR sensitivity. Using Langmuir-Blodgett (LB) method, gold film with nano-structured surface was devised. In order to make a new SPR chip, firstly, a single layer of nano-scaled silica particles adhered to plain surface of gold film. Thereafter, gold was deposited on the template by an e-beam evaporator. Finally, the nano-structured surface with basin-like shape was obtained after removing the silica particles by sonication. In this study, two types of silica particles, or 130 nm and 300 nm, were used as template beads and sensitivity of the new SPR chip was tested with ethanol solution, respectively. Applying the new developed SPR sensor to a model food of alcoholic beverage, the sensitivity showed improvement of 95% over the conventional one.

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

LSTM Based Prediction of Ocean Mixed Layer Temperature Using Meteorological Data (기상 데이터를 활용한 LSTM 기반의 해양 혼합층 수온 예측)

  • Ko, Kwan-Seob;Kim, Young-Won;Byeon, Seong-Hyeon;Lee, Soo-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.603-614
    • /
    • 2021
  • Recently, the surface temperature in the seas around Korea has been continuously rising. This temperature rise causes changes in fishery resources and affects leisure activities such as fishing. In particular, high temperatures lead to the occurrence of red tides, causing severe damage to ocean industries such as aquaculture. Meanwhile, changes in sea temperature are closely related to military operation to detect submarines. This is because the degree of diffraction, refraction, or reflection of sound waves used to detect submarines varies depending on the ocean mixed layer. Currently, research on the prediction of changes in sea water temperature is being actively conducted. However, existing research is focused on predicting only the surface temperature of the ocean, so it is difficult to identify fishery resources according to depth and apply them to military operations such as submarine detection. Therefore, in this study, we predicted the temperature of the ocean mixed layer at a depth of 38m by using temperature data for each water depth in the upper mixed layer and meteorological data such as temperature, atmospheric pressure, and sunlight that are related to the surface temperature. The data used are meteorological data and sea temperature data by water depth observed from 2016 to 2020 at the IEODO Ocean Research Station. In order to increase the accuracy and efficiency of prediction, LSTM (Long Short-Term Memory), which is known to be suitable for time series data among deep learning techniques, was used. As a result of the experiment, in the daily prediction, the RMSE (Root Mean Square Error) of the model using temperature, atmospheric pressure, and sunlight data together was 0.473. On the other hand, the RMSE of the model using only the surface temperature was 0.631. These results confirm that the model using meteorological data together shows better performance in predicting the temperature of the upper ocean mixed layer.