• Title/Summary/Keyword: 굴절동등

Search Result 3, Processing Time 0.015 seconds

A Comparison of Refractive Components in Anisometropia and Isometropia (굴절부등안과 동등안의 양안 굴절요소 차이 비교)

  • Shim, Hyun-Seog;Shim, Jun-Beom;Kim, Eun-Suck
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • Purpose: This study was to compare differences between both eyes in corneal powers, axial lengths, anterior chamber depths in anisometropia and isometropia, and to investigate the relationship between anisometropia and refractive components. Methods: The subject was a total of 83 patients, anisometropia 45 patients (90 eyes) and isometropia 38 patients (76 eyes) from 2.7 to 15.3 years old, prescribed eyeglasses and contact lenses by refraction from July 2010 to August 2010 in Gwangju City B eye clinic. Axial length, anterior chamber depth, corneal curvature, and corneal refractive power were measured using IOL Master. Refractive error was measured using an Auto-refractometer. Results: Anisometropia was a statistically significant difference in axial length, binocular refractive components, refractive error, and axial length, Axial length/corneal radius (AL/CR) ratio showed a statistically significant difference in anisometropia and isometropia. The major cause of anisometropia all 45 subjects was the axial length. Among the refractive components axial length, AL/CR had a strong correlation, but corneal refractive power had no correlation. Anterior chamber depth had a weak correlation. Conclusions: This study found that refractive error was the most axial ametropia caused by the axial length. The main cause of anisometropia was the axial length, but refractive components had a weak correlation.

Autofocusing Mechanism of a Triple-Magnification Infrared System (3중 배율 적외선 영상 장비의 자동 초점 조절 방안)

  • Jung, Hyojung;Jeong, Suseong;Yang, Yunseok;Lee, Yongchun;Han, Jeongsu
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.314-320
    • /
    • 2020
  • The optics used in an infrared imaging system has a strong refractive-index change according to temperature, so an autofocus control function is essential for a military infrared imaging system with a wide operating-temperature range. In this study, we design a triple-magnification infrared imaging system, and to compensate for the change in refractive index according to temperature we measure the change in the lens focus according to temperature. The autofocus control function was implemented by using the measured movement amount, and we could obtain an image with satisfactory resolution performance over a wide range of operating temperatures.

Evaluation of the Bioequivalence of Simvastatin 20mg Tablets in Healthy Volunteers (조코 정에 대한 엘바스타 정의 생물학적 동등성 평가)

  • Yun, Hwi-yeol;Kang, Wonku;Kwon, Kwang-il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.15 no.1
    • /
    • pp.41-45
    • /
    • 2005
  • 심바스타틴은 cholesterol 생합성 과정에서 속도 조절 효소인 HMG-CoA reductase의 강력한 상경적 길항약으로서 고지혈증 치료에 널리 쓰이는 약물이다. 심바스타틴 제제인 MSD 사의 조코 20 mg정을 대조약으로 하여 시험약인 유영 제약의 엘바스타 20mg정의 생물학적 동등성 평가를 하기 위해 22명의 건강한 지원자를 모집하였다. 지원자를 두 군으로 나누어 2정씩 투여하였고 $2{\times}2$ 교차시험을 실시하였다. 심바스타틴의 혈장 중의 농도를 정량하기 위하여 발리데이션된 LC/MS/MS를 사용하였다. 채혈 시간은 투약 전 및 투약 후 0.5, 1, 1.5, 2, 2.5, 3, 4, 6, 8, 10, 12 시간에 걸쳐 총 12시점에 걸쳐 시행하였다. 생물학적 동등성을 판정하기 위한 파라미터로 12시간까지의 혈장 중 농도곡선 하 면적 ($AUC_{12hr}$)과 최고 혈중 농도($C_{max}$)를 사용하였다. 12시간 까지의 혈중 농도 곡선 하 면적의 기하 평균은 $17.30ng{\cdot}ml/hr$(시험약)과 $17.35ng{\cdot}ml/hr$(대조약)으로 나타났다. 최고 혈중 농도의 경우 각 각 5.08 ng/ml(시험약)과 5.20 ng/ml(대조약)으로 관찰 되었다. $AUC_{12hr}$의 경우 로그변환한 평균치 차의 $90{\%}$ 신뢰구간이 log0.8510 - log1.1694이었고, $C_{max}$의 경우 log0.8176 - log1.1649로 계산되어 두 항목 모두 log0.8-log1.25이어야 한다는 식품의약품 안전청과 FDA의 기준을 모두 만족시켰다. 이상의 결과를 종합하면 시험약 엘바스타 정 20mg은 대조약 조코정 20 mg에 대하여 생물학적 동등한 것으로 판정되었다.트리머 전기비저항 탐사를 수행하였다. 이를 통해 하저에 케이블을 설치하는 방식에 비해 매우 신속하고 경제적으로 하저에 분포하는 이상대의 분포범위와 발달방향을 규명할 수 있었다.대에 대해 가장 효과적이다. 모델과 현장 적용 결과들을 통해 GRM SSM 방법을 이용하여 불규칙한 굴절면을 가진 지층들에 대해 좀 더 신뢰할 수 있는 정밀한 탄성파 속도를 산출할 수 있음을 보여주고 있다.별한 주의를 기울여야 한다.EX>$\alpha/\beta$=10인 경우 $62.0\~121.9\;Gy_{10}$ (중앙값: $93.0\;Gy_{10}$)의 분포를, ${\alpha/\beta}=3$인 경우 $93.6\~187.3\;Gy_3$ (중앙값=$137.6\;Gy_3$ )의 분포를 보였다. MD-BED $Gy_3$는 직장합병증 발생과의 관계는 통계적으로 유의하였고, 방광합병증과는 유의하지 않았다. 직장합병증과의 연관성은 MD-BED $Gy_3$보다 개별 환자의 직장전벽 총 선량 BED값인 R-BED $Gy_3$가 훨씬 더 높았다. 요도카테터 풍선의 후방지점이 대변하는 방광의 총 선량 BED값인 V-BED $Gy_3$도 방광합병증과 경향성 테스트에서 통계적 유의성을 보였다. 하지만, 어떠한 방사선선량도 골반제어율과 의미 있는 상관관계를 보이지 않았다. 본 기관에서 주치의의 선호도에 따라 강내근접치료가 외부방사선치료의 중간에 시행되는 형태인 샌드위치기법과 외부방사선치료 후반부에 시행되는 순차적 기법으로 구분하였을 때, 두 방식간 치료성적 및 합병증의 차이는 없었다. 총 치료기간에 대한 분석에서는 치료기간이 길어질수록 재발 위험이 커지는 경향을 보였으나, 나이 및 병기, 종양의 크기, MD-BED $Gy_{10}$

  • PDF