• Title/Summary/Keyword: 군 지연

Search Result 754, Processing Time 0.044 seconds

Type-Based Group Delay Equalizer Considering the Nonlinear Phase Distortion of HPA (HPA의 비선형 위상 왜곡을 고려한 타입기반 군 지연 등화기)

  • Kim, Yongguk;Jo, Byung Gak;Baek, Gwang Hoon;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.10
    • /
    • pp.895-902
    • /
    • 2012
  • In this paper, we propose a novel equalizer to compensate for the group delay including AM/PM nonlinear distortion characteristics by the nonlinear power amplifier (PA). The group delay characteristic is a nonlinear non-constant time delay that appears differently depending on each frequency component. The phase distortion by AM/PM characteristics arising from the power amplifier is a major factor to increase group delay. By the group delay distortion, the signal in the constellation expands and is rotated. Considering the problem mentioned above, the nonlinear time delay that appears differently depending on each frequency component is classified as a static group delay and AM/PM characteristic of PA, the different phase transitions depending on the size of input signal as a dynamic group delay. Static group delay estimates and compensate for phase distortions in the frequency domain with type-based method and dynamic group delay compensates for phase rotation in the time domain. We confirmed that the group delay compensation techniques were enough to compensate the group delay characteristics including AM/PM characteristics of the power amplifier.

Effects of Group Delay and Non-linear Characteristics in Ka-Band High Data Rate Satellite Communication System (Ka 대역 초고속 위성통신 시스템에 대한 군지연 및 비선형 특성의 영향)

  • 김영완;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.4
    • /
    • pp.600-610
    • /
    • 2001
  • The effects of group delay and non-linear characteristics on high data rate(HDR) satellite channel are presented in this paper Based on the modeling of group delay and non-linear characteristics the system performances which provide various data rate services were analyzed in Ka-band satellite channel. As the transmission data rate is increased, the degradation due to these channel characteristics is severely increased. The linear component of group delay and the AM-AM component of non-linear characteristics severely affect the system performance. To efficiently provide the various service via the same transmission system it is necessary to equalize the primary impairment factors. The optimum operating points of HDR satellite transmission system are implemented by considering the analyzed results on channel characteristics.

  • PDF

The study was to investigate the Spontaneous therapy, TENS and Ice therapy of Biceps brachii after induction of DOMS (자연치유와 경피신경전기자극치료, 그리고 냉치료가 지연성근육통이 유발된 위팔두갈래근의 통증과 근력 및 근활성도에 미치는 영향)

  • Kim, Keun-Jo;Lee, Cu-Rie;Jung, Byeong-Ok;Bang, Hyun-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.491-494
    • /
    • 2009
  • 본 논문에서는 비우세 팔굽관절 굽힘근육에 원심성운동을 실시하여, 지연성근육통을 유발시킨 후, 자연치유과 경피신경전기자극치료, 그리고 냉치료의 효과를 조사하는데 그 목적이 있다. 자연치유군과 경피신경 전기자극치료군, 그리고 냉치료군의 평가를 위해 팔꿉관절의 운동시에 시상통증척도(VAS), 최대 염력, 실 효치 값을 측정하여 평가하였다. 대상자는 신체적 결함이 없는 30명의 성인을 대상으로 하였고, 대상자들은 지연성근육통 유발 후, 3개의 군인 자연치유군, 경피신경전기자극치료군, 냉치료군으로 나누었고, $60^{\circ}$/초의 등속성 각속도에서 최대 근력으로 운동시에 최대 연력과 실효치 값, 그리고 시상통증척도를 측정하여 평가하였다. 1. 시상통증척도는 경피신경전기자극치료군의 치료3일차에서 다른 군과 다른 기간에 비해 가장 낮은 수치를 나타내었고, 통계적으로 유의하였다(p<.05). 2. 최대 염력은 경피신경전기자극치료군의 치료3일차에서 다른 군과 다른 기간에 비해 가장 높은 수치를 나타내었고, 통계적으로 유의하였다(p<.05).3. 실효치 값은 경피신경전기자극치료군의 치료3일차에서 다른 군과 다른 기간에 비해 가장 높은 수치를 나타내었고, 통계적으로 유의하였다(p<.05). 이상의 연구 결과로 보아 경피신경전기자극치료는 지연성근육통에 대하여 자연 치유나 냉치료에 비해 더욱 효과적인 치료 방법임을 알 수 있다. 그러므로, 지연성근육통을 가진 환자의 치료 시에 경피신경전기자극치료의 적용은 권장되어야 한다.

  • PDF

A Study on the Synthesis of a Self-Equalized Dual-Passband Filter (군지연 등화된 두 개의 통과대역을 갖는 필터의 합성에 관한 연구)

  • Lee Juseop;Uhm Man Seok;Park Jong Heung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.19-25
    • /
    • 2005
  • This paper describes a synthesis method for a self-equalized dual-passband filter. Compared to conventional dual-passband filter, a self-equalized dual-passband filter can reduce BER(bit error rate) in digital data communications and does not need an external equalizer for group-delay equalization. To validate the synthesis technique, a 10-pole dual-mode dual-passband filter which has two self-equalized 5-pole elliptic response passband is synthesized.

Comparison of Results Between Immediate Fixation Group and Delayed Reconstruction Group in Displaced Mid-shaft Fractures of the Clavicle (쇄골 전위성 간부 골절에서 조기 고정술 군과 지연 재건술 군 간의 결과 비교)

  • Kim, Doo-Sub;Rah, Jung-Ho;Yoon, Yeo-Seung;Lee, Chang-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.61-66
    • /
    • 2009
  • Purpose: Several authors have reported excellent results of delayed reconstruction of non-union & malunion in displaced mid-shaft fractures of the clavicle and these results were equal to that of immediate fixation. But direct comparison between these treatments is rare. We evaluated the results between the immediate fixation group and delayed reconstruction group for treating displaced mid-shaft fractures of the clavicle. Materials and Methods: We studied the results of 18 cases with immediate fixation of displaced mid-shaft fractures of the clavicle and 15 cases with delayed reconstruction of non-union & malunion after conservative management, and these cases were seen from March 2000 to February, 2006. The final postoperative outcome was analyzed according to the clinical outcomes with using the Constant score and the radiological findings of bony union. Results: The constant score was low in the delayed reconstruction group compare to that of the immediate fixation group (p value=0.045). For the pain score & the activities of daily living score, a statistically significant difference was seen between the two groups (p<0.05), but not for the range of motion score & the power score (p>0.05). Radiological findings of bony union were seen for both groups at an average of 8.8 weeks for the immediate fixation group and at an average of 9.8 weeks for the delayed reconstruction group. Conclusion: Though the delayed reconstruction group was shown good clinical and radiological results, the immediate fixation group had a significantly better pain score, a better activities of daily living score and a better Constant score. It is important to choose the initial treatment option for displaced mid-shaft fractures of the clavicle after sufficient explanation to patients about the merits and demerits between these two treatment options.

Microwave Group Delay Time Adjuster Using Resonance Circuit (공진 회로를 이용한 마이크로파 군지연 시간 조정기)

  • Seo Su-Jin;Park Sang-Keun;Choi Heung-Jae;Jeong Yong-Chae;Yun Jae-Hun;Kim Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.8 s.111
    • /
    • pp.739-745
    • /
    • 2006
  • This paper presents a method to control group delay tine using a resonance circuit. The group delay time adjuster(GDTA) that can control signal group delay time comprises a variable capacitance and a variable equivalent inductor. These are coupled in parallel at a node and also controlled by two bias voltages separately, A variable equivalent inductor is realized a transmission line terminated a variable capacitor. Group delay time can be controlled by change of capacitance and inductance, but the resonating frequency is fixed. When the proposed GDTA is fabricated on RFID Korean frequency band$(908.5{\sim}914 MHz)$, a group delay variation is obtained about 3 ns.

Randomized Trial of Early Versus Late Alternating Radiotherapy/ Chemotherapy in Limited-Disease Patients with Small Cell Lung Cancer (국한성병기 소세포폐암 환자에서 조기 혹은 지연 교대 방사선-항암제치료의 전향적 비교연구)

  • Lee Chang Geol;Kim Joo Hang;Kim Sung Kyu;Kim Sei Kyu;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.116-122
    • /
    • 2002
  • Purpose : A randomized prospective study was conducted to compare the efficacy of early or late alternating schedules of radiotherapy, and carboplatin and ifosfamide chemotherapy in patients with limited-disease small cell lung cancer. Materials and Methods: From August 1993 to August 1996, a total of 44 patients with newly diagnosed, limited-disease small cell lung cancer, PS $H0\~2$, wt $loss<10\%$ were enrolled in a randomized trial which compared early alternating radiotherapy (RT)/chemotherapy (CT) and late alternating RT/CT. The CT regimen included ifosfamide $1.5\;g/m^2$ IV, d1-5 and carboplatin AUC 5/d IV, d2 peformed at 4 week intervals for a total of 6 cycles. RT (54 Gy/30 fr) was started after the first cycle of CT (early arm, N=22) or after the third cycle of CT (late arm, N=22) with a split course of treatment. Results : The pretreatment characteristics between the two arms were well balanced. The response rates in the early $(86\%)$ and late $(85\%)$ arm were similar. The median survival durations and 2-year survival rates were 15 months and $22.7\%$ in the early arm, and 17 months and $14.9\%$ in the late arm (p=0.47 by the log-rank test). The two-year progression free survival rates were $19.1\%$ in the early arm and $19.6\%$ in the late arm (p=0.52 by the log-rank test). Acute grade 3 or 4 hematologic and nonhematologic toxicities were similar between the two arms. Eighteen patients $(82\%)$ completed 6 cycles of CT in the early arm and 17 $(77\%)$ in the late arm. Four patients received less than 45 Gy of RT in the early arm and two in the late arm. There was no significant difference in the failure patterns. The local failure rate was $43\%$ in the early arm and $45\%$ in the late arm. The first site of failure was the brain in $24\%$ of the early arm patients compared to $35\%$ in the late arm (p=0.51). Conclusion : There were no statistical differences in the overall survival rate and the pattern of failure between the early and late alternating RT/CT in patients with limited-disease small cell lung cancer.

A Design of a 5 GHz Low Phase Noise Voltage Tuned Dielectric Resonator Oscillator Using Loop Group Delay (루프 군지연을 이용한 저위상 잡음 5 GHz 전압제어 유전체 공진기 발진기 설계)

  • Son, Beom-Ik;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.269-281
    • /
    • 2014
  • In this paper, a systematic design of a low phase noise voltage-tuned dielectric resonator oscillator(VTDRO) using loop group delay is proposed. Designed VTDRO is closed-loop type and consists of a cascade connection of a resonator, phase shifter, and amplifier. Firstly, a reference VTDRO is fabricated and its phase noise and electrical frequency tuning range are measured. Both the phase noise and electrical frequency tuning range depend on the loop group delay. Then, a required value of loop group delay for a new VTDRO with a low phase noise can be systematically computed. In addition, its phase noise and electrical frequency tuning range can be theoretically estimated using those obtained from the measurement of the reference VTDRO. When the loop group delay increases, the phase noise decreases and the electrical frequency tuning range also decreases. The former predominantly depends on the resonator structure. Therefore we propose a systematic design procedure of a resonator with high group delay characteristics. The measured loop group delay of the new VTDRO is about 700 nsec. The measured phase noise of the new VTDRO show a state-of-the-art performance of 154.5 dBc/Hz at 100 kHz frequency offset and electrical frequency tuning range of 448 kHz for a voltage change of 0~10V. The oscillation power is about 4.39 dBm.

A Comparison of Outcomes after Early and Delayed Reconstruction in the Acute Anterior Cruciate Ligament Injuries (급성 전방십자인대 손상 환자에서 조기 재건군과 지연 재건군의 결과 비교)

  • Lee, Soo Won;Kim, Sung Hwan;Kim, Yoon Gi
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.34-39
    • /
    • 2012
  • Purpose: This study performed to compare degree of joint stiffness and clinical results between early and delayed reconstruction of acute anterior cruciate ligament (ACL) injuries. Materials and Methods: Thirty-four Patients who underwent ACL reconstruction between March 2008 and October 2010 enrolled this study. We divided the patient into 2 groups, early reconstruction group underwent surgery before a week, delayed reconstruction group underwent surgery after 3 weeks, before 6 weeks. All the patients underwent aggressive joint motion exercise till surgery and enrolled post operative rehabilitation program including self exercise. We checked range of motion, the Lachman test, the pivot shift test, the Lysholm score, the International Knee Documentation Committee (IKDC) score and the Tegner score to evaluate the results. Results: At the final follow up. The Lysholm score was 91.82 in the early group and 94.83 in the delayed group. All the cases were rated above B (near normal) on IKDC score (P=0.217, P=0.845). The Tegner score was 6.7 in the early reconstruction group and 7.1 in the delayed group (P=0.840), there was no difference between the groups for the range of motion (P=0.873, P=0.873), no complication such as deep vein thrombosis or infection, no difference in the Lachman test, pivot shift test (P=0.606, P=0.118). Conclusion: We could obtain satisfactory clinical results in both the early and delayed reconstruction groups of acute ACL injuries. Therefore, the early reconstruction of ACL performed before a week could be one of the treatment options for acute ACL injury.

  • PDF

The effect of loading time on the stability of mini-implant (교정력 부하시기에 따른 교정용 미니 임플란트의 안정성)

  • Lee, Seung-Yeon;Cha, Jung-Yul;Yoon, Tae-Min;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.149-158
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the stability of mini-implants in relation to loading time. Methods: A total of 48 mini-implants (ORLUS, Ortholution, Korea) were placed into the buccal alveolar bone of the mandible in 8 male beagle dogs. Orthodontic force (200-250gm) was applied immediately for the immediate loading group while force application was delayed for 3 weeks in the delayed loading group. For the subsequent loading periods (3, 6, 12 weeks), BIC (bone implant contact) and BV/TV (bone volume/total volume) and mobility test were carried out. Results: The immediate loading group showed no changes in BIC from 3 to 12 weeks, while the delayed loading group showed a significant increase in BIC between 3 and 12 weeks (p<0.05). The BV/TO of the delayed loading group significantly increased from 6 to 12 weeks of loading (p<0.05), while the BV/TV of the immediate loading group decreased from 3 to 12 weeks of loading. However, there was no significant difference in BV/TV between experimental groups. The mobility of the immediate loading group was not significantly different from that of the delayed loading group after 12 weeks of loading (p<0.05). Conclusions: These results showed that immediate loading does not have a negative effect on the stability of mini-implants compared to the early loading method in both the clinical and histomorphometric point of view.