• Title/Summary/Keyword: 국제전자기술위원회

Search Result 50, Processing Time 0.023 seconds

Evaluation of Angle Optimization on Edge Test Device Setting in Modulation Transfer Function (변조전달함수 방법에서 엣지 장치 설정에 대한 각도 최적화 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • This study was purpose to evaluation of Modulation Transfer Function in Measurements by using the International electrotechnical commission standard(IEC 62220-1) which were edge device each angle by using edge method. In this study was Aero(Konica, Japan) image receptor which is a indirect Flat panel detector(FPD) was used. The size of matrix 1994 × 2430 (14"× 17" inch) which performed 12 bit processing and pixel pitch is 175 ㎛. The results of shown as MTF measurements at IEC standard. The amount of data seemed reasonable and at an MTF value of 0.1 the spatial frequencies were 2.56 cycles/mm at an angle of 2.4°. MTF value of 0.5 the spatial frequencies were 1.32 cycles/mm at an angle of 2.4°. This study were to evaluate MTF by setting each angle 2.0°~2.8° degrees the most effective optimal edge angle and to suggest the quantitative methods of measuring by using IEC.

Evaluation of Resolution Characteristics by Using Chart Device Angle (차트 각도를 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.375-380
    • /
    • 2021
  • This study aim was quantitative assessment of MTFs of spectrum of the square wave chart images and Coltman chart images for 0°, 1.7°, 2.2°, 2.9°, 4.1° by using chart method. In general device was AccuRay-650 (DK Medical System, Korea) used, indirect flat panel detector(FPD) Aero (Konica, Japan) used and MATLAB R2019a (MathWorks, USA) used. The result of comparison for each angle of MTF the edge image was highest quantitatively value for MTF finding of showed the best value of 0.1 based on the frequency of 3.5 mm-1, value of 0.1 based on the square wave was frequency of 3.0 mm-1 and value of 0.1 based on the Coltman transform was frequency of 2.4 mm-1. In this study it was significant that the methodology of the international Electro-technical Commission was applied mutandis by using the Fujita method within 2~3°.

The effect of electromagnetic of the electrostatic discharge device with the high-voltage air discharge (고전압 기중방전을 갖는 정전 방전장치의 전자기 영향)

  • Kim, Myoung-Seok;Oh, Joon-Sick;Han, Gyu-Hwan;Park, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1482-1483
    • /
    • 2006
  • 고전압 방전시험 장치는 국제전기기술위원회 규격(IEC 61000-4-2)에서 규정하고 있는 콘덴서 방식을 사용하며, 매우 짧은 시간에 방전함으로서 펄스 형태의 방전전류가 통전된다. 이러한 정전기적인 방전에 의해 전자기기에 고장을 발생시키며 이를 검증하는 방법으로 정전기 내성시험법이 있다. 본 논문에서는 첫째로 방전장치가 발생하는 잡음 전계량을 측정하였고, 둘째로 방전장치를 시험시료에 근접하는 방법에 따른 시험시료에 미치는 영향을 실험을 통해 검증하였고, 셋째로 근접방법에 따른 정전유도 현상이 시험시료에 미치는 영향을 실험적으로 검증하였다. 이러한 세 가지 현상을 바탕으로 시험시료가 고전압 방전장치를 근접 방전하여 방전을 유발시켰을 때의 전자파의 영향에 내성을 갖고 있는지를 검증하는 새로운 시험방법을 제안하였다.

  • PDF

A Study on the effect of the revised Use of the Object Catalogue for ENC (전자해도 객체 카탈로그 입력지침 개정에 따른 영향에 관한 연구)

  • Ko, Hyun-Joo;Oh, Se-Woong;Suh, Sang-Hyun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.11a
    • /
    • pp.86-87
    • /
    • 2011
  • Use of the Object Catalogue for ENC(UOC) which can be important reference to encoding detailed attribute for ENC has been prohibited to the revision. Recently new edition is developed through the discussion of IHO TSMAD working group, therefore, it is expected to have a effect to production systems, encoders and ECDIS OEMs. In this study, revised UOC was analyzed and compared to previous documents. In conclusion, the effects to the related systems, encoders and OEMs, and their implecations are drawn from that.

  • PDF

21세기 에너지개발과 고압직류(HVDC) 송전의 역할

  • 변종달
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.283
    • /
    • pp.62-67
    • /
    • 2000
  • 미국전기전자학회(IEEE)의 1999년도 파워 엔지니어링 소사이어티(PES) 윈터 미팅이 미국 뉴욕시에서 개최되었으며, 여기에서는 고압직류(HVDC)송전 기술이 21세기의 에너지개발 프로그램에서 수행하게 될 역할에 대한 발표가 있었다. 패널리스트들은 HVCD 기술이 앞으로 어떻게 활용될 것이며, 직류송전의 유리한 점을 적용시킬 수 있는 전세계의 지역, 기대되는 HVDC 기술의 혁신 그리고 이들이 민간주도로 이루어질 수 있을 것인가에 대하여 초점을 맞추었다. 그들을 또한 전력공급산업에 나타나고 있는 HVDC 송전연계 시스템에 대한 규제철폐의 충격에 대하여 토의하였으며, 기술혁신이 직류 변환소이 건설비를 감축시킬 수 있을 것인지에 대한 논의도 있었다. 제기된 문제에는 아래의 것이 포함되어 있다. - 기설 교류 송전시스템을 직류방식으로 전환시키는 상황이 발생할 수 있을 것인가? -투자자 소유의 독집 직류방식 송전선로 프로젝트가 실현될 수 있을 것인가? -시스템 성능을 본질적으로 개선 시킬 수 있도록 직류방식 송전시스템에 적용시킬 수 있는 개선책은 무엇인가? PES의 에너지개발 및 발전위원회의 국제분과위원회 위원장인 토마스 J. 하몬스 씨(영국 스코틀랜드의 글래스고 대학)가 세션의 좌장을 맡았으며, 매니토바 하이드로(캐나다)의 데니스 우드포드씨가 모더레이터 역을 맡았다. 그리고 하몬스 씨와 우드포드 씨가 이 세션을 계획$\cdot$준비하였다. 이 문제에서 국제적인 시야를 가지는 패널리스트들은 HVDC 송전기술의 장래에 대한 전망을 가지는데 비하여 북아메리카에 국한된 시야를 가지는 패널리스트들은 HVDC 사용에 대한 장래의 잠재성을 낮게 보고 있는 것이 흥미로운 일이다.

  • PDF

Research of Electric Pilotage Service using Intelligence Aids to Navigation System (인공지능 항로표지 시스템을 이용한 전자도선 서비스에 관한 연구)

  • GANG, Yongsoo;JEONG, Haesang;KIM, Jeong-Rok;GUG, Seung-Gi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.107-108
    • /
    • 2019
  • In the past, regional pilot service is provided by individual pilots directly on board each ship, but it will be difficult to provide this type of service in the near future when autonomous vessels are activated. This can be seen as the need for automation and intelligence of pilot service and provision of remote control system. In this paper, we propose a method, system, and service target that can carry out the electronic pilot service through the intelligence aids to navigation for smart port operation.

  • PDF

Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography (간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Kim, Ki-Won;Kwon, Kyung-Tae;Jung, Jae-Yong;Son, Jin-Hyun;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.457-462
    • /
    • 2018
  • The purpose of this study was to compare image quality of indirect digital radiography (IDR) system using the International Electro-technical Commission standard (IEC 62220-1), and to suggest the analysis of noise power spectrum (NPS) which were applied to IEC 62220-1 in medical imaging. In this study, Pixium 4600 (Trixell, France) which is indirect flat panel detector (FPD) was used. The size of image receptor (IR) is $7{\times}17$ inch (matrix $3001{\times}3001$) which performed 14bit processing and pixel pitch is $143{\mu}m$. In IEC standard, NPS evaluation were applied to RQA3, RQA5, RQA7 and RQA9. Because of different radiation quality, each region of interesting (ROI) were compared. The results of NPS indicated up to $3.5mm^{-1}$ including low Nyquist frequency. RQA5 indicated the lowest NPS and the others indicated higher NPS results relatively. NPS result of ROI a38 was higher than ROI a92 and this result indicated that there are more noise in left (cathode) than right (anode). This study were to evaluate NPS by using different radiation quality and setting the each ROI, and to suggest the quantitative methods of measuring NPS.

Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography (간접평판형 검출기에서 변조전달함수 측정 시 Edge 각도에 따른 비교 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.259-263
    • /
    • 2019
  • This study was purpose to compare image quality of Indirect digital radiography (IDR) system by using the International electro-technical commission standard(IEC 62220-1) which were applied to IEC in medical imaging. To evaluation the analysis of Modulation transfer function(MTF) measurements edge device each angle by using edge method. In this study, Aero (Konica, Japan) which is Indirect flat panel detector(FPD) was used, the size of image receptor matrix $1994{\times}2430$ which performed 12bit processing and pixel pitch is $175{\mu}m$. In IEC standard method were applied to each angle were compared. The results of shown as LSF at $2.0^{\circ}$ and $3.0^{\circ}$ angeles. Shape is constant and shows smooth shape. The amount of data seemed reasonable and 2.19 cycles/mm and 2.01 cycles/mm at a spatial frequency of $2.0^{\circ}$ and $3.0^{\circ}$ at an MTF value of 0.1. At an MTF value of 0.5, the spatial frequencies were $2.0^{\circ}$ and 1.11 cycles/mm and 0.93 cycles/mm at an angle of $3.0^{\circ}$. This study were to evaluate MTF by setting the each $2{\sim}3^{\circ}$ each angle and to suggest the quantitative methods of measuring by using IEC.

Calculation of the Magnetic Field Homogeneity in the Induction coil for the Magnetic Field Immunity Test (자기장 내성평가용 유도코일의 자기장 균일도 계산)

  • 유권상;김창석
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.4
    • /
    • pp.64-70
    • /
    • 1994
  • the magnetic field homogeneities of the induction coils of various sizes and shapes were investigated in order to prepare for the magnetic field immunity test under the power frequency, the pulse and the damed oscillatory fields recommended by the IEC. For this purpose, we analyzed the magnetic field homogeneities in the two induction coils with $1m\times1m$, and $1m\times2.6m$, , and the double square coils with 0.8m and 0.6m spaced. The testing volume within $\pm$3dB in the double square coil with 0.8m spaced in twice bigger than single square coil with 1m side in the z-direction.

  • PDF

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.