• Title/Summary/Keyword: 국소화

Search Result 413, Processing Time 0.026 seconds

Botulinum A toxin for the treatment of focal hyperhidrosis -5 cases- (국소화 다한증에 대해 보툴리늄 독소를 이용한 치료 -5례보고-)

  • Lee, Song-Am;Kim, Kwang-Taik;Park, Sung-Min;Chung, Bong-Kyu;Sun, Kyung;Kim, Hyoung-Mook;Lee, IIn-Sung
    • Journal of Chest Surgery
    • /
    • v.33 no.3
    • /
    • pp.268-272
    • /
    • 2000
  • Thoracic sympathicotomy has been used safely and successfully to treat essential hyperhidrosis. However, it has been difficult to treat compansatory hyperhidrosis after thoracic sympathicotomy and focal hyperhidrosis. The sweat glands were innervated by post-ganglionic sympathetic fibers with acetylcholic serving as the transmitter. Botulinum A toxin has been reported to block neuro-transmission at the cholinergic autonomic nerve terminals. Prospecting its effect for the sweat gland, we treated 5 patients with focal hyperhidrosis with botulinum A toxin. Three patients received bilateral thoracic sympathectomy (1 case) and sympathicotomy(2 case) via VAT. The hyperhidrosis area was marked with betadine and was subdivided into squares of 2$\times$2 cm(4$\textrm{cm}^2$) each. Botulinum A toxin was injected intracutaneously in a dosage of 2.5U/0.1ml(100U/4ml) /4$\textrm{cm}^2$. A total dose of 100U of Botulinum A toxin was injected into the affected sites. Subjective assessment of sweat production by the patients using a visual analogue scale showed a 20~70% improvement. During the follow-up period, no toxic effects were observed.

  • PDF

Robust iris recognition for local noise based on wavelet transforms (국부잡음에 강인한 웨이블릿 기반의 홍채 인식 기법)

  • Park Jonggeun;Lee Chulhee
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.121-130
    • /
    • 2005
  • In this paper, we propose a feature extraction method for iris recognition using wavelet transforms. The wavelet transform is fast and has a good localization characteristic. In particular, the low frequency band can be used as an effective feature vector. In iris recognition, the noise caused by eyelid the eyebrow, glint, etc may be included in iris. The iris pattern is distorted by noises by itself, and a feature extraction algorithm based on filter such as Wavelets, Gabor transform spreads noises into whole iris region. Namely, such noises degrade the performance of iris recognition systems a major problem. This kind of noise has adverse effect on performance. In order to solve these problems, we propose to divide the iris image into a number of sub-region and apply the wavelet transform to each sub-region. Experimental results show that the performance of proposed method is comparable to existing methods using Gabor transform and region division noticeably improves recognition performance. However, it is noted that the processing time of the wavelet transform is much faster than that of the existing methods.

Monte Carlo Photon and Electron Dose Calculation Time Reduction Using Local Least Square Denoising Filters (국소 최소자승 잡음 감소 필터를 이용한 광자선 및 전자선 몬테칼로 선량 계산 시간 단축)

  • Cheong Kwang-Ho;Suh Tae-Suk;Cho Byung-Chul;Jin Hosang
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.138-147
    • /
    • 2005
  • The Monte Carlo method cannot have been used for routine treatment planning because of heavy time consumption for the acceptable accuracy. Since calculation time is proportional to particle histories, we can save time by decreasing the number of histories. However, a small number of histories can cause serious uncertainties. In this study, we proposed Monte Carlo dose computation time and uncertainty reduction method using specially designed filters and adaptive denoising process. Proposed algorithm was applied to 6 MV photon and 21 MeV electron dose calculations in homogeneous and heterogeneous phantoms. Filtering time was negligible comparing to Monte Carlo simulation time. The accuracy was improved dramatically in all situations and the simulation of 1 $\%$ to 10$\%$ number of histories of benchmark in photon and electron dose calculation showed the most beneficial result. The empirical reduction of necessary histories was about a factor of ten to fifty from the result.

  • PDF

Pseudo Continuous Arterial Spin Labeling MR Imaging of Status Epilepticus (간질중첩증의 동맥 스핀 라벨링 자기공명영상)

  • Yi, Min-Kyung;Choi, Seung-Hong;Jung, Keun-Hwa;Yoon, Tae-Jin;Kim, Ji-Hoon;Sohn, Chul-Ho;Chang, Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.142-151
    • /
    • 2012
  • Purpose : The purpose of this study was to describe arterial spin labeling MR image findings of status epilepticus. Materials and Methods: A retrospective chart review within our institute revealed six patients who had been clinically diagnosed as status epilepticus and had also undergone MR imaging that included ASL in addition to routine sequences. Results: Six patients with status epilepticus were studied by conventional MR and arterial spin labeling imaging. All patients showed increased regional CBF correlating with EEG pathology. Notably, in two patients, conventional MRI and DWI showed no abnormal findings whereas pCASL demonstrated regional increased CBF in both patients. Conclusion: Arterial spin labeling might offer additional diagnostic capabilities in the evaluation of patients with status epilepticus.

Hepatocellular Carcinoma with Right Atrial Invasion Detected by PET/CT (우심방에 침범한 간세포암을 PET/CT로 진단한 1예)

  • Kim, Ji-Hoon;Kim, Eun-Sil;Yu, Ji-Won;Ahn, Seok-Jin;Jung, Jun-Oh;Kim, So-Yon;Kim, Young-Jung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.414-418
    • /
    • 2008
  • The role of positron emission tomography (PET) with F-18 fluorodeoxyglucose (F-18 FDG) in the diagnosis of hepatocellulcar carcinoma (HCC) has been limited because of a variable FDG uptake in HCC. However, the usefulness of PET/CT for detecting extrahepatic metastasis and monitoring of the treatment response in HCC has been reported. A 55-year-old man with a hepatitis B surface antigen-positive, was admitted to our hospital due to dyspnea, general weakness and body weight loss for one month. Chest X-ray showed multiple reticulo-nodular densities on both lower lung fields, which implies metastatic lesions. F-18 FDG PET/CT revealed consecutively intense hypermetabolic mass in right hepatic lobe, inferior vena cava and right atrium. We report a case of HCC with IVC and right atrium invasion identified by F-18 FDG PET/CT.

LORETA analysis of EEG responding to positive/negative emotional stimuli for different sensitivities of behavioral activation and inhibition systems (긍/부정 감성자극에 대한 행동활성화체계 및 행동억제체계 민감도에 따른 뇌파의 LORETA 분석)

  • Kim Wuon-Shik;Jin Seung-Hyun
    • Science of Emotion and Sensibility
    • /
    • v.8 no.4
    • /
    • pp.403-413
    • /
    • 2005
  • The purpose of the present study was to investigate the responses to positive/negative emotional stimuli for the different sensitivities of behavioral activation system (BAS) and behavioral inhibition system (BIS). We recorded If-channel EEG data for 8 BAS sensitive subjects an48 BIS sensitive subjects. EEGs were analyzed with LORETA (Low-resolution electromagnetic tomography) From scalp-recorded electrical potential distribution, LORETA computes the three-dimensional intracerebral distributions of current density for specified EEG frequency bands. hs results , significant differences between the BAS sensitive group ant the BIS sensitive group appeared LORETA alpha activities over the prefrontal lobe and the cingulate gyrus. Prefrontal regions and limbic system including cingulate gyrus are involved in emotional processing. Moreover, subjects with the high BAS sensitivity. responded more sensitively to the positive stimulation than subjects with the high BIS sensitivity. Therefore, our results suggest the possibility of correlation between BAS/BIS sensitivity and positive/negative emotional stimuli.

  • PDF

The Performance of Ictal Brain SPECT for Localizing Epileptogenic Foci in Temporal Lobe Epilepsies (측두엽 간질에서 발작기 뇌관류 SPECT의 간질병소 국소화 성능)

  • Kim, Eun-Sil;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Chang, Kee-Hyun;Lee, Sang-Kun;Chung, Chun-Kee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.287-293
    • /
    • 1995
  • Anterior temporal lobectomy has become a widely used resective surgery in patients with medically intractable temporal lobe epilepsies. Prerequisites of this resection include the accurate localization of the epileptogenic focus and the determination that the proposed resection would not result in unacceptable postoperative memory or language deficits. The purpose of this study was to evaluate the performance of ictal SPECT compared to MRI findings for localization of epiletogenic foci in this group of patients. 11 patients who had been anterior temporal lobectomy were evaluated with ictal $^{99m}Tc$-HMPAO SPECT and MRI. MRI showed 8/11(73%) concordant lesion to the side of surgery and ictal SPECT also showed 8/11(73%) concordant hyperperfusion. In 3 cases with incorrect or nonlocalizing findings of MRI, ictal SPECT showed concordant hyperperfusion. In 2 cases confirmed by pre-resectional invasive EEG, MRI showed bilateral and contralateral lesion but ictal SPECT showed concordant hyperperfusion. 3 delayed injection of ictal SPECT showed discordant hyperperfusion. Thus, ictal SPECT was a useful method for localizing epileptogenic foci in temporal lobe epilepsis and appeared complementay to MRI.

  • PDF

Electronic Structures and Magnetism of MgCCo3(001) (MgCCo3(001)표면의 전자구조와 자성)

  • Jin, Ying-Jiu;Lee, Jae-Il
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.3
    • /
    • pp.94-98
    • /
    • 2004
  • The electronic structures and magnetism of MgCCo$_3$(001) surface terminated by the plane with the MgCo-Term (Mg, Co terminated) and the CCo-Term (C, Co terminated) were investigated using the all-electron full-potential linearized augmented Plane-wave method. For the MgCo-Term, the magnetic moment of Co atom of the surface is strongly enhanced to 1.00$\mu$$_{B}$, while the magnetic moment of Co atom of the subsurface is similar to that of the center layers. For the CCo-Term, the magnetic moments of Co atoms are enhanced to 0.75 and 0.80$\mu$$_{B}$ for the surface and subsurface layers, respectively. The magnetic moments of C and Mg atoms are coupled antiferromagnetically to that of the neighbour Co atoms. From the calculated density of states, we see that the enhancements of magnetic moments of Co atoms are closely related to localization of the Co-3d states.

Super-Pixels Generation based on Fuzzy Similarity (퍼지 유사성 기반 슈퍼-픽셀 생성)

  • Kim, Yong-Gil;Moon, Kyung-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.147-157
    • /
    • 2017
  • In recent years, Super-pixels have become very popular for use in computer vision applications. Super-pixel algorithm transforms pixels into perceptually feasible regions to reduce stiff features of grid pixel. In particular, super-pixels are useful to depth estimation, skeleton works, body labeling, and feature localization, etc. But, it is not easy to generate a good super-pixel partition for doing these tasks. Especially, super-pixels do not satisfy more meaningful features in view of the gestalt aspects such as non-sum, continuation, closure, perceptual constancy. In this paper, we suggest an advanced algorithm which combines simple linear iterative clustering with fuzzy clustering concepts. Simple linear iterative clustering technique has high adherence to image boundaries, speed, memory efficient than conventional methods. But, it does not suggest good compact and regular property to the super-pixel shapes in context of gestalt aspects. Fuzzy similarity measures provide a reasonable graph in view of bounded size and few neighbors. Thus, more compact and regular pixels are obtained, and can extract locally relevant features. Simulation shows that fuzzy similarity based super-pixel building represents natural features as the manner in which humans decompose images.

Development of a Current-Type Electromagnetic Flowmeter to Obtain the Liquid Mean Velocity in Two-Phase Slug Flow (슬러그류 액상속도 측정용 전류형식 전자기유량계 개발)

  • Kang, Deok-Hong;Ahn, Yeh-Chan;Kim, Jong-Rok;Oh, Byung-Do;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1951-1956
    • /
    • 2004
  • The transient nature and complex flow geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et $al.^{(1)}$). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. To do this, the velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for the simulated slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are required for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

  • PDF