• Title/Summary/Keyword: 국부 거동

Search Result 443, Processing Time 0.022 seconds

Formulating the Local Displacement and Local Moments of a Plate Stiffened with Open Ribs According to the Loading Sizes (재하 크기에 따른 개단면 리브 보강판의 국부 처짐과 국부 모멘트의 정형화)

  • Chu, Seok Beom
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.267-278
    • /
    • 2013
  • In this study, stiffened plates with open ribs are analyzed to estimate and formulate the local displacement and local moments according to square loading sizes. For the local behaviors of plates stiffened with rectangular and reverse T ribs, the ratio functions according to the dimensions of stiffened plates are obtained at each square loading size. Analytical results show that values of the basic stiffened plates are different but the ratio functions of each square loading size are similar and the difference of the ratio functions between rectangular ribs and reverse T ribs are small, so the ratio functions can be unified by integrating the loading sizes regardless of the rib type. The application of the unioned ratio functions to L type ribs and rectangular loading shows good accuracies. Therefore, the local behaviors of plates stiffened with open ribs can easily be obtained by using the unioned ratio functions proposed in this study.

Experimental Study on the Similitude of Small-Scale Models in Cyclic Lateral Behaviors of RC Shear Wall Subassemblages (RC벽식 부분구조의 반복 횡하중 거동에서의 축소모델 상사성 실험연구)

  • Lee, Han-Seon;Cho, Chang-Seok;Lee, Sang-Ho;Oh, Sang-Hoon;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.805-816
    • /
    • 2010
  • For earthquake simulation test it is essential to make sure the similitude in behaviors between the full scale prototype and the reduced scale model. This paper presents the test results obtained through the cyclic lateral-force test, on two-story RC wall subassemblages. A lower 2-story portion of the prototype structure was selected as subassemblages. The global behavior such as the strength and ductility, and the local behavior such as flexural, shear and uplift deformation were measured. The test results of the 3 : 5 scale specimens representing the prototype were compared with those of 1 : 7 scale models. Two types of subassemblages were used: One with lintel beams and one without lintel beams. The comparison shows that 1 : 7 scale model simulated in general successfully the global and local behaviors of the prototype.

Study on the Ultimate Strength of Gusset Plate-Circular Hollow Section(CHS) Joint Stiffened with Rib-plate by End Restraint (단부 구속을 받는 리브 보강 플레이트 원형강관 X형 접합부의 극한내력 도출에 관한 연구)

  • Kim, Woo-Bum;Park, Hyun-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.383-398
    • /
    • 2012
  • A finite element analysis study was performed to investigate the behavior and strength of a Plate-Circular Hollow Section joint stiffened with Rib-plate, Since The strength of plate-Circular Section joint is reduced by joint of stress and local plastic deformation which is caused by wall moment, rib plates are attached to the upper and lower Plate-Circular Hollow Section joint for redistribution of stress. The behaviors of joints stiffened with Rib-plate according to shape of rib and reinforcing method, etc are different from those of joints which is not stiffened. However, the criterion of hollow structural section was limited on some parts. Therefore, this study intends to investigate the behavior and structural capacity of Plate-Circular Hollow Section joints stiffened with Rib-plate and compare the Finite element analysis with the Design Equation. Finally, this study proposes the reasonable ultimate strength formula through the comparisons with other design guide.

Local Buckling of Built-up Square Tubular Compression Members Fabricated with HSA800 High Performance Steels under Concentric Axial Loading (중심압축력을 받는 건축구조용 고성능강(HSA800) 용접 각형강관 압축재의 국부좌굴)

  • Yoo, Jung-Han;Kim, Joo-Woo;Yang, Jae-Keun;Kang, Joo-Won;Lee, Dong-Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.435-442
    • /
    • 2012
  • Recently, high performance(strength) steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using high performance steel, material properties of high performance rolled steel building structures. HSA800 was compared with the requirements of Korean Standards(KS) for HSA800. Welded square tube stub columns with variables of width-to-thickness ratios are planned in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio and uniaxial compressive tests are carried out. In addition, the local buckling behaviors of stub columns obtained finite element analysis were compared with those of test results.

Evaluation on Applicability of Built-up Square Tubular Compression Members Fabricated with HSA800 High Performance Steel Considering Local Buckling (국부좌굴을 고려한 건축구조용 고성능강(HSA800) 조립각형강관 압축재의 적용성 평가)

  • Yoo, Jung Han;Kim, Joo Woo;Yang, Jae Guen;Kang, Joo Won;Lee, Dong Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.223-231
    • /
    • 2013
  • Recently, high-performance steels have been increasingly used for structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper offers a series of basic study for the design specification of structural members using high performance steel, that is material properties of HSA800 (High-performance rolled steel for building structures). Built-up square tube stub columns with variables of width-to-thickness ratios are planned as a parametric study in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio. In addition, the buckling behaviors of stub columns obtained finite element (FE) analysis were compared with those from experimental tests. The verified FE model was used for parametric study and checked applicability of high-strength steel on current design specification.

Deformation Behavior of Locally Stiffness-variant Stretchable Substrates Consisting of the Island Structure (섬(Island) 구조로 이루어진 강성도 국부변환 신축성 기판의 변형 거동)

  • Oh, Hyun-Ah;Park, Donghyeun;Shin, Soo Jin;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.117-123
    • /
    • 2015
  • In order to develop stretchable substrate technology for stretchable devices, locally stiffness-variant stretchable substrates were processed with two polydimethylsiloxane elastomers of different stiffnesses and their deformation behavior was characterized. Low-stiffness substrate matrix and embedded high-stiffness island of the stretchable substrate were formed by using Dragon Skin 10 of the elastic modulus of 0.09 MPa and Sylgard 184 of the elastic modulus of 2.15 MPa, respectively. A stretchable substrate was fabricated to a configuration of 6.5 cm length, 0.4 cm thickness, and 2.5 cm width. The elastic modulus of a stretchable substrate was increased from 0.09 MPa to 0.13~0.33 MPa by embedding a Sylgard 184 island of 1 cm width and 1~6 cm length into the center part of the Dragon Skin 10 substrate matrix. The elastic modulus of a stretchable substrate was improved to 0.16~0.2 MPa by embedding a Sylgard 184 island of 4 cm length and 0.5~1.5 cm width and to 0.1421~0.154 MPa by embedding a Sylgard 184 island of 2 cm length and 0.5~1.5 cm width. With increasing the tensile strain of a stretchable substrate, deformation restriction of the locally stiffness-variant Sylgard 184 island was further enhanced due to substantial increase in the strength difference between Sylgard 184 and Dragon 10 at large strain.

Local Buckling Behavior of Stub H-shaped Columns Fabricated with HSA800 High Performance Steels under Concentric Axial Loading (중심압축력을 받는 건축구조용 고성능강(HSA800) 용접H형 단주의 국부좌굴거동)

  • Lee, Kangmin;Lee, Myung Jae;Oh, Young Suk;Kim, Tae Soo;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.289-297
    • /
    • 2013
  • In this study, the local buckling behavior of steel built-up columns, fabricated with grade 800MPa high performance (HSA800), was investigated to verify the suitability of width-to-thickness ratio limits adopted by the current design code. For this purpose, an experimental program was designed and performed for HSA800 steel column specimens with various width-to-thickness ratios. Then the experimental results were compared and verified with finite element analysis results. The parametric analytical studies with various width-to-thickness ratios were also performed to investigate the missing data from the limited experimental studies. From the experimental and analytical studies, It was found that the finite analysis models could reasonably estimate the test results within the 5.3% average differences. The local buckling behaviors of HSA800 steel columns were found to be largely depend on the values of initial imperfection introduced into finite element analyses.

Numerical simulation of local scour around porous type fish reef (다공성 인공어초의 국부세굴 특성 분석 수치모형실험)

  • Yoon, Jae Seon;Lee, Ji-Hun;Shin, Choong Hun;Ha, Taemin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.233-233
    • /
    • 2019
  • 본 연구에서는 3형식 다공성 인공어초의 국부세굴 발생에 따른 인공어초의 안정성 검토를 위하여 3차원 수치모형인 FLOW-3D의 Sediment 모듈을 적용하여 분석을 실시하였다. 실험파랑 설정을 위하여 인공어초 설치 예정지인 서해 대상해역(대청도, 연평도 인근)의 100년 빈도 설계파랑을 적용하였으며, Bretschneider-Mitsuyasu 스펙트럼 기법을 통하여 파랑을 재현하였다. 원형상격자 조건은 최대 0.1m~2.0m에 해당하며, 수치모형실험 해석 시간을 고려하여 입사파랑의 진행방향으로 인공어초의 1/2 폭에 해당하는 X축(190개), Y축(80개), Z축(110~180개) 영역에 대한 격자조건 설정하고 분석을 실시하였다. 분석은 인공어초 하중에 따른 동적 거동을 반영하는 FSI(Flood Structure Interaction)기법을 적용하였으며, 분석결과 인공어초 구조물 하단의 돌출부분에서 세굴발생이 확인되었으며, 최대세굴심은 3형식 인공어초의 규격 및 단위체적당 중량이 클수록 높게 발생하였다.

  • PDF

Determination of Efficient Shear Stud Spacing in Steel-Concrete Panel(SCP) considering Local Buckling Behavior (국부좌굴 현상을 고려한 강판 콘크리트 패널의 효율적인 스터드 배치 간격 설정)

  • Kim, JoungRae;Lee, WonHo;Kwak, Hyo-Gyoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.479-484
    • /
    • 2017
  • In this paper, finite element analysis of Steel-Concrete panel(SCP) was conducted considering the local buckling behavior and the optimized design of shear studs arrangement was studied by comparing with design guidelines. If the spacing of the studs of SCP is widened, it is easy to be manufactured and the weight fo members become lighter. On the other hand, the steel plate would be vulnerable to the local buckling behavior. Therefore, the guidance and design of SCP limit the maximum spacing of the studs to prevent the development of shear cracks and local buckling, however this is based on the design criteria of the other composite structures. Parameter studies with changes in stud spacing on steel plate and SCP are conducted and the obtained result was compared with values given in design guidelines.

Modelling for Cyclic Behavior of the Panel Zone (패널 영역의 주기거동에 대한 모델링)

  • Kim, Kee Dong;Lee, Hak Eun;Ko, Man Gi;Kil, Heung Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.1 s.30
    • /
    • pp.139-147
    • /
    • 1997
  • 본 논문은 단조하중(monotonic loading)하의 강재 보-기둥의 절점의 패널 영역 거동을 연구한 논문(Kim 1997)의 후속 논문으로 주기하중에 대한 패널영역의 거동을 해석하기 위한 이력법칙(hysteretic rules)에 관한 것이다. 제안된 이력법칙은 실험결과와 합당한 상관관계를 보여주었고, 이 이력법칙을 사용한 패널영역요소의 해석 결과가 실험결과와 잘 일치하는 것으로 나타났다. 한편 보강판(a doubler plate)을 갖는 패널영역에 대한 해석과 실험결과로 부터 보강판이 패널영역전달력 (panel zone shear force)을 저항하는데 있어 부분적인 효과만 있다는 것을 알 수 있었다. 제안된 패널영역요소는 구조물의 전체 거동과 국부 변형을 기존의 패널영역요소(bilinear panel zone element)보다 정확하게 예측 할 수 있었다.

  • PDF