• Title/Summary/Keyword: 구조응답해석

Search Result 1,453, Processing Time 0.034 seconds

Long Term Monitoring of Dynamic Characteristics of a Jacket-Type Offshore Structure Using Dynamic Tilt Responses and Tidal Effects on Modal Properties (동적 경사 응답을 이용한 재킷식 해양구조물의 장기 동특성 모니터링 및 조류 영향 분석)

  • Yi, Jin-Hak;Park, Jin-Soon;Han, Sang-Hun;Lee, Kwang-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.97-108
    • /
    • 2012
  • Dynamic responses were measured using long-term monitoring system for Uldolmok tidal current pilot power plant which is one of jacket-type offshore structures. Among the dynamic quantities, the tilt angle was chosen because the low frequency response components can be precisely measured by dynamic tiltmeter, and the natural frequencies and modal damping ratio were successfully identified using proposed LS-FDD (least squared frequency domain decomposition) method. And the effects of tidal height and tidal current velocity on the variation of natural frequencies and modal damping ratios were investigated in time and frequency domain. Also the non-parametric models were tested to model the relationship between tidal conditions and modal properties such as natural frequencies and damping ratios.

Evaluation of Seismic Response Characteristics of Hong-Seong Area based on In-Situ and Laboratory Tests (현장 및 실내시험에 기초한 홍성지역 지진응답특성 평가)

  • 박덕근;김교원
    • The Journal of Engineering Geology
    • /
    • v.11 no.1
    • /
    • pp.25-35
    • /
    • 2001
  • For the ground resrxmse analysis, both in-situ and laboratory testing techniques such as downhole, SASW, resonant column and torsional shear tests were perlormed for Hong-Seong area. The grOlmd upper 30m is classified as SD since it has an average shear wave velocity as 209m/s. The response specLrums obtained by site-specific analyses generally satisfied the seismic code, but near the resonance period the motion was evaluated to be higher than the code.

  • PDF

Analysis on Formulas for Floor Vibration Response (바닥구조의 진동응답의 계산식에 대한 분석)

  • 이성수
    • Computational Structural Engineering
    • /
    • v.17 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • 이미 현존하는 건물의 경우는 진동실험을 통하여 바닥판에서의 정확한 진동응답을 찾아낼 수 있으나, 현존하지 않는 건물을 설계하고 있는 단계에서는 계산식이나 컴퓨터에 의한 동적해석으로 그 값을 예측할 수밖에 없다. 이러한 과정에서 간편하게 접근할 수 있는 방법이 국내외의 진동평가방법이나 기술지침서에 소개도어 있는 진동응답식을 이용하는 방법이다. 현존하는 건물의 경우에서도 복잡한 진동실험을 하기 전에 간단한 예비적 평가를 하기 위하여 이러한 계산식이 이용되기도 한다.(중략)

Stochastic Analysis of Base-Isolated Pool Structure Considering Fluid-Structure Interaction Effects (유체-구조물 상호작용을 고려한 면진구조물의 추계학적 응답해석)

  • Koh, Hyun Moo;Kim, Jae Kwan;Park, Kwan Soon;Ha, Dong Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.463-472
    • /
    • 1994
  • A method of stochastic response analysis of base-isolated fluid-filled pool structures subject to random ground excitations is studied. Fluid-structure interaction effects between the flexible walls and contained fluid are taken into account in the form of added mass matrix derived by FEM modeling of the contained fluid motion. The stationary ground excitation is represented by Modified Clough-Penzien spectral model and the nonstationary one is obtained by imposing an envelope function on the stationary one. The stationary and nonstationary response statistics of the two different isolation systems are obtained by solving the governing Lyapunov covariance matrix differential equations.

  • PDF

Transfer Path Analysis (전달경로 해석 사례)

  • Lee, Sang-Yeop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.349-349
    • /
    • 2010
  • 전달 경로 해석 기법은 NVH 문제 해결 프로세스에서 자주 사용되는 기법으로서 소음원 X 전달 경로= 응답 모델을 사용한 접근방식입니다. 수음(응답)점에서 문제의 진동 및 소음 응답을 고체 및 공기 음원이 응답에 미치는 기여도 또는 개별 경로, 모드, 판넬 기여도의 합으로 세분화하여 표시함으로써, 문제의 원인을 규명하고, 문제 해결 및 대책 방안에 대한 통찰력을 제시하며, NVH 문제의 해결을 위해 사용되는 필수적인 도구입니다. 본 강좌에서는 건물에 설치되는 설비의 작동 시 고체 음원 평가 및 철도 소음의 공기음과 구조음 기여도 평가를 위해 적용된 전달 경로 해석 기법 사례를 소개할 것입니다. 설비 작동시의 전달 경로 해석 기법에 의해 평가된 고체 음원의 신뢰성 확보를 위하여 $\bullet$ 직접 측정된 하중 데이터와 역행렬 기법에 의해 예측된 하중 비교 및 $\bullet$ 가진 햄머로 가진시의 가진력과 측정된 가속도 신호를 사용하여 역행렬 기법으로 계산된 하중의 비교를 수행하였습니다. 철도 소음의 공기음 및 고체음 기여도 평가를 위해서는 $\bullet$ 열차 주행중 철로에서 측정된 가속도를 사용하여 철로면에 가해지는 하중을 역행렬 기법으로 계산하였으며 $\bullet$ 철로 주변에서 거리별 측정된 소음중, 고체음의 기여도 파악을 위해서, 전달 경로 해석기법으로 예측된 고체음과 측정된 소음을 비교하였습니다.

  • PDF

Direct Design Sensitivity Analysis of Frequency Response Function Using Krylov Subspace Based Model Order Reduction (Krylov 부공간 모델차수축소법을 이용한 주파수응답함수의 직접 설계민감도 해석)

  • Han, Jeong-Sam
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.153-163
    • /
    • 2010
  • In this paper a frequency response analysis using Krylov subspace-based model reduction and its design sensitivity analysis with respect to design variables are presented. Since the frequency response and its design sensitivity information are necessary for a gradient-based optimization, problems of high computational cost and resource may occur in the case that frequency response of a large sized finite element model is involved in the optimization iterations. In the suggested method model order reduction of finite element models are used to calculate both frequency response and frequency response sensitivity, therefore one can maximize the speed of numerical computation for the frequency response and its design sensitivity. As numerical examples, a semi-monocoque shell and an array-type $4{\times}4$ MEMS resonator are adopted to show the accuracy and efficiency of the suggested approach in calculating the FRF and its design sensitivity. The frequency response sensitivity through the model reduction shows a great time reduction in numerical computation and a good agreement with that from the initial full finite element model.

Seismic Behaviors of Concrete-Suction-Type Offshore Wind Turbine Supporting Structures Considering Soil-Structure Interaction (지반-구조물 상호작용을 고려한 콘크리트 석션식 해상풍력 지지구조물의 지진거동 특성)

  • Lee, Jin Ho;Jin, Byeong-Moo;Bae, Kyung-Tae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.4
    • /
    • pp.319-327
    • /
    • 2017
  • In this study, characteristics of seismic behaviors of offshore wind turbine systems using concrete-suction-type supporting structures are investigated. Applying hydrodynamic pressure from the surrounding sea water and interaction forces from the underlying soil to the structural system which is composed of RNA, the tower, and the supporting structure, a governing equation of the system is derived and its earthquake responses are obtained. It can be observed from the analysis results that the responses are significantly influenced by soil-structure interaction because dynamic responses for higher natural vibration modes are increased due to the flexibility of soil. Therefore, the soil-structure interaction must be taken into consideration for accurate assessment of dynamic behaviors of offshore wind turbine systems using concrete-suction-type supporting structures.

Earthquake Response Analysis of an Offshore Wind Turbine Considering Fluid-Structure-Soil Interaction (유체-구조물-지반 상호작용을 고려한 해상풍력발전기의 지진응답해석)

  • Lee, Jin-Ho;Lee, Sang-Bong;Kim, Jae-Kwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.1-12
    • /
    • 2012
  • In this study, an analysis method for the earthquake response of an offshore wind turbine model is developed, considering the effects of the fluid-structure-soil interaction. The turbine is modeled as a tower with a lumped mass at the top of it. The tower is idealized as a tubular cantilever founded on flexible seabed. Substructure and Rayleigh-Ritz methods are used to derive the governing equation of a coupled structure-fluid-soil system incorporating interactions between the tower and sea water and between the foundation and the flexible seabed. The sea water is assumed to be a compressible but non-viscous ideal fluid. The impedance functions of a rigid footing in water-saturated soil strata are obtained from the Thin-Layer Method (TLM) and combined with the superstructure model. The developed method is applied to the earthquake response analysis of an offshore wind turbine model. The method is verified by comparing the results with reference solutions. The effects of several factors, such as the flexibility of the tower, the depth of the sea water, and the stiffness of the soil, are examined and discussed. The relative significance of the fluid-structure interaction over the soil-structure interaction is evaluated and vice versa.

Frequency-Domain Analysis for Motion of Floating Structures with Perforated Wall (유공벽이 설치된 부유체 동요 평가를 위한 주파수 영역 해석)

  • Jeongsoo Kim;Youn Ju Jeong;Young-Taek Kim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • As increasing demands for a floating structure expanded from offshore industry facilities to living facilities, it has emerged that necessity of techniques to reduce motions of a floating structure. This study present a floating structure with porosity on the outer surface of the floater. Under each regular and irregular wave, responses of the floater was investigated in frequency domain. The proposed structure is composed of inner and outer floaters, which are connected to each other and the outer wall is perforated, and the heave and the pitch of floaters with different perforation rates (0~30%) were compared with at both the center and the edge. The results showed that pitch responses can be decreased by increasing of perforation rate of the floater. Comparing with responses of the non-perforated floater, those of the proposed floating structure were reduced to above 10% and 2%, respectively for regular and irregular wave conditions.