• Title/Summary/Keyword: 구조시험

Search Result 5,851, Processing Time 0.03 seconds

Compression Test of Subelement and Tension Test of Hoop Ring for Stiffness Evaluation of Conical Composite Lattice Structures (콘형 복합재 격자 구조의 강성 평가를 위한 Subelement의 압축 시험 및 후프 링의 인장 시험)

  • Jeon, Min-Hyeok;Kong, Seung-Taek;No, Hae-Ri;Kim, In-Gul;Lee, Sang-Woo
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.169-175
    • /
    • 2020
  • The compression and tension test were performed to evaluate the stiffnesses of the conical composite lattice structures and results of test were compared with finite element analysis results. Because of difficulty to perform simple tension and compression test due to conical shape, suitable specimens and jig for test were made. Subelements extracted from the structure were prepared for compression test. Compression test of subelement was performed and compressive strains in fiber direction were measured. Compressive stiffness of the helical rib was verified by finite element analysis results. For stiffness of hoop rib, hoop ring specimens were extracted from the structure. Tension test of hoop ring specimen was performed to apply bending deformation to hoop rib. Stiffness of hoop rib was verified by finite element model considering various fiber volume fraction in thickness direction.

저궤도 지구관측위성 비행모델 정현파 가진시험 결과 분석

  • Kim, Gyeong-Won;Kim, Chang-Ho;Im, Jae-Hyeok;Kim, Won-Seok;Kim, Seon-Won;Hwang, Do-Sun
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.32.1-32.1
    • /
    • 2011
  • 이 논문에서는 저궤도 지구관측위성 비행모델의 정현파 가진시험 결과에 대하여 분석하였다. 정현파 가진시험은 발사환경시험중의 하나로서, 저주파 대역의 정현파 진동 환경하에서 인공위성의 안정성을 검증하는데 그 목적이 있다. 정현파 가진시험의 입력선도는 발사체로부터 선정되어진다. 발사체로부터 선정된 입력선도는 극한의 경우를 고려한 선도이므로 실제 정현파 가진시험시에는 입력선도에 적절한 노칭을 적용하여야 한다. 노칭은 주구조물의 대한 1차 노칭과 부가 구조물에 대한 2차 노칭으로 구분이 되어 적용되었다. 정현파 가진시험의 전후에는 저수준 정현파가진시험을 수행하였으며, 주파수 응답함수를 비교함으로서 구조적으로 문제가 없는지를 확인하였다. 시험 후, 육안검사를 통하여 구조 부재가 이상이 없는지를 최종 확인하였으며, 인공위성비행모델이 정현파 가진 환경하에서 충분히 안전함을 확인하였다.

  • PDF

The Study on Structural Strength Test Technique by Using Compressed Air Type Loading Method (공기압식 외력부가방법을 이용한 구조강도 시험기법 연구)

  • Kim, Jong-Hwan;Lee, Kee-Bhum;Kim, Ho-Yeon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.376-381
    • /
    • 2010
  • The structural strength tests are usually performed to evaluate the structural strength and to verify the structural design and analysis of the vehicle structures. In this paper, the development of a compressed loading type apparatus to load distributed force over the surface of vehicle structure subjected to external loads was described. This apparatus is for structural materials which are easily to fail because of concentrated stresses. This apparatus can apply loads to specimens without any damage on the test specimen's surfaces by using flexible membrane and can be applicable to several kinds of surface profile of structures. The structural strength tests for the flat structure and curved structure with this apparatus were successfully performed, and the test results showed that this type of loading apparatus can be adequate to verify the structural integrity of the fragile structures.

A Study on Structural Test and Derivation of Standard Finite Element Model for Composite Vehicle Structures of Automated People Mover (자동무인경전철 복합재 차체 구조물의 구조 시험 및 해석적 검증에 의한 유한요소 모델 도출 연구)

  • Ko, Hee-Young;Shin, Kwang-Bok;Kim, Dae-Hwan
    • Composites Research
    • /
    • v.22 no.5
    • /
    • pp.1-7
    • /
    • 2009
  • The vehicle structure of Automated People Mover(APM) made of aluminum honeycomb sandwich with WR580INF4000 glass-fabric epoxy laminate facesheets was evaluated by structural test and finite element analysis. The test of the vehicle structure was conducted according to JIS E 7105. The structural integrity of vehicle structure was evaluated by stress, deflection and natural frequency obtained from dial-gauge and acceleration sensor. And the proposed finite element models were compared with the results of structural test. The results of finite element analysis showed good agreement with those of structural test. Also, in order to improve the stiffness of vehicle structure, the modified underframe model with reinforced side sill was proposed in design stage. The composite vehicle structures with modified underframe model had the improved structural stiffness about 44%.

Structural Behaviors of Precast Concrete Box Structures Using Recycled Aggregate (순환골재 콘크리트 박스 구조의 거동)

  • Byun, Keun-Joo;Song, Ha-Won;Kim, Ho-Jin;Nam, Jin-Won;Kim, Ki-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.93-102
    • /
    • 2006
  • In order to use a recycled aggregate concrete for precast concrete box structures, the structural behaviors should be analytically and experimentally evaluated. In this study, full-scale precast concrete box structures are manufactured using the recycled aggregate (30% replacement) and natural aggregate. Then, the flexural failure test and shear failure test as well as water leakage lest for the structures arc carried out. First of all, test results of compressive strength show that recycled aggregate concrete is only 4% lower than normal concrete. In the flexural and shear failure test, the structural performances of precast box using the recycled aggregate concrete are 95% of the capacities of normal precast concrete box or more. Especially, the water leakage test shows that leakage pressure of recycled concrete box is more than the critical value, 60kPa, as well as 9% higher than normal precast concrete box. These test results are analyzed and compared with results of finite clement analysis. The comparison shows that test results are more excellent than analytical results. Also, the comparison confirms the applicability of recycled aggregate concrete for the use as practical precast concrete box structure.

  • PDF

Stiffness, Rigidity and Vibration Prevention in Precision Machine Foundation Design (장비기초설계의 강성 및 진동저감에 관한 연구)

  • Park Ok-Jeoung;Kim Jin-Ho;Jeon Han-Jun
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.994-1000
    • /
    • 2004
  • 대형시험장비가 설치되는 실험실의 계획에서 장비의 진동은 간과할 수 없는 고려사항이다. 따라서 시험장비를 지지하는 구조물과 기초의 설계시 시험장비의 운행 중 발생하는 공진을 피할 수 있는 구조적 체계의 진동특성에 대한 적절한 평가가 요구된다. 본 논문은 동적특성을 얻기 위해 바닥구조물의 FE 모델링에 관하여 기술하였다. 또한 진동저감을 위한 시험장비기초의 설계를 위해 tuning, 진동기준. 방진시스템을 검토하였다. 시험장비의 진동을 줄이는 최선의 방법은 low tuning 이였으며 이의 구현을 위해 방진스프링과 함께 단단한 콘크리트 블록위에 시험장비를 설치하였다. 총체적인 방진시스템의 구조적 진동특성은 이동성, 힘, 속도 스펙트라를 이용해 표현되었다. 전달과 지점이동 FRF의 비를 시뮬레이션을 통해 비교함으로서 바닥 슬래브의 진동전달 정도가 관찰되었다.

  • PDF

금속재 세미 모노코크 콘형 구조체의 정적 구조 시험

  • Park, Soon-Hong;Jang, Young-Soon;Yi, Yeong-Moo
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.129-142
    • /
    • 2005
  • A semi-monocoque truncated cone structure, which is a main structure for the payload adapter of KSLV-I, was designed. Static test was performed to confirm the reliability of the cone structure under the design loads. Strains and displacements are measured during four load cases; the compressive axial, pure bending, pure shear, and combined loading conditions. The results showed that the cone structure satisfies the design requirements. An equivalent axial load was applied to the cone structure so that the global buckling of the cone structure occurred. The measured buckling load was compared with the predicted one by finite element method. The results show a good agreement.

  • PDF

Structural Health Monitoring System for "Uldolmok" Tidal Current Power Pilot Plant and Its Applications (울돌목 시험조류발전소에 대한 구조건전성감시 시스템 구축 및 활용)

  • Yi, Jin-Hak;Park, Jin-Soon;Park, Woo-Sun;Lee, Kwang-Soo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.114-118
    • /
    • 2009
  • 이 논문에서는 울돌목 시험조류발전소에 구축 중인 구조건전성 감시시스템의 계획, 설치 및 활용에 대하여 소개하였다. 현재 시험조류발전소에 설치된 센서로는 전기저항식 변형률계, 광섬유 FBG(Fiber Bragg Grating) 센서, 압전형 MFC(Macro Fiber Composite) 센서, 2축 경사계, 서보형 가속도계 등과 같은 지지구조물의 구조거동을 감시하기 위한 센서와 토크 센서, RPM 센서 등 발전 계통에 대한 감시를 위한 센서, 그리고 H-ADCP(Horizontal Acoustic Doppler Current Profiler)와 같은 외력조건에 대한 계측 장비 등이 있다. 센서 설치 후 현재까지 부분적으로 계측된 자료를 소개하고, 향후 건전성 감시시스템 개선 계획을 소개하였다.

  • PDF

Assessment of Structural Performance of Transparent Noise Barrier Consisting of Steel-FRP Composite Frame (강재-FRP 합성단면 프레임 투명방음판 구조성능 평가)

  • Lee, Dae-Yong;Kim, Jin-Kook;Kim, Sang-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.956-959
    • /
    • 2007
  • 기존 투명방음판용 알루미늄 프레임의 구조적 단점을 보완할 수 있는 강재-FRP(Fiber Reinforced Plastic) 합성단면 구조재를 개발하였으며, 아울러 조립이 간편하고 외부 충격에 의해 쉽게 분리가 되지 않는 삽입형 수평재-수직재 코너연결부 상세를 개발하였다. 개발된 강재-FRP 합성단면 구조재와 코너연결재를 결합하여 프레임을 형성하고 그 사이에 투명패널을 삽입함으로써 길이 4m, 높이 1m 투명방음판 시작품을 완성하였으며, 이렇게 완성된 투명방음판 시작품을 대상으로 KS 4770-1 구조성능 평가시험을 수행하였다. 한국도로공사 교량부 시험하중에 대해 설계된 강재-FRP 합성단면 프레임 투명방음판의 구조성능 평가결과, FRP 의 추가적인 구조강성 증가 효과로 인해 한국도로공사 교량부 시험하중을 약간 상회하는 KS 2 호 등급시험하중까지도 만족시키고 있음을 확인할 수 있었다.

  • PDF

The Method of Structural Test Pattern Extraction for Object-Oriented Framework Test (객체지향 프레임워크의 구조적 테스트 패턴 추출방법)

  • 김장래;전태웅
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10a
    • /
    • pp.445-447
    • /
    • 2000
  • 객체지향 프레임워크는 다수의 응용 소프트웨어 개발에 반복적으로 재사용되므로 철저한 시험이 요구될 뿐만 아니라 재사용시 확장된 프레임워크에 대해서도 추가적인 시험이 필요하다. 본 논문에서는 재사용시 다양한 형태의 객체 구조들로 개조, 확장될 수 있는 프레임워크의 가변부위에 대해 구조적 테스트 패턴들을 프레임워크의 합성 패턴들로부터 조직적으로 추출하는 방법을 기술한다. 여기서 제안된 방법은 가변부위 클래스 구조의 테스트 모델을 정형 명세화하고, 이로부터 시험에 필요한 구조적 테스트 패턴을 추출하는 방법을 제공한다.

  • PDF