• Title/Summary/Keyword: 구조보강

Search Result 2,829, Processing Time 0.022 seconds

Shear Reinforcement for Flat Plate-Column Connections Using Lattice Bars (래티스 철근을 이용한 무량판-기둥 접합부의 전단보강)

  • Ahn Kyung-Soo;Park Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.191-200
    • /
    • 2005
  • Flat plate-column connections are susceptible to brittle punching shear failure, which may result in collapse of the overall structure. In the present study, a new shear reinforcement for the plate-column connection, the lattice shear reinforcement was developed. Experimental study for the lattice shear reinforcement was performed. Shear strength and ductility of the specimens reinforced with the lattice bars were compared with those of unreinforced specimens. The test results showed that the strength and ductility of the specimens with the lattice shear reinforcement were improved by 1.37 and 9.16 times those of the unreinforced specimens, respectively. These results indicates that the lattice shear reinforcement is superior in ductility to the shear stud-rail which is popular in U.S. Based on the test results, the design method for the lattice shear reinforcement was developed.

Enhancements in Performance and Manufacturing Efficiencies of GFRP Rebar (GFRP 보강근의 성능 및 제작 효율화 방안)

  • You, Young Jun;Kim, Jang Ho;Park, Young Hwan;Park, Ji Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.110-119
    • /
    • 2012
  • Fiber reinforced polymer (FRP) reinforcing rebar with non-corrosive property is suggested as an alternative replacement to steel reinforcing rebar due to its enhanced durability and non-corrosive characteristics. Currently, a limited number of glass fiber reinforced polymer rebar (GFRP) are sold commercially due to their high cost, relatively low performances, and brittle failure characteristics. Therefore, the performance enhancements and cost reduction of GFRP rebar are needed to increase its applications in construction fields. The intent of this study is to develop high performance GFRP rebar by improving its tensile and shear properties. Also, in order to reduce manufacturing costs, factors such as material composition and manufacturing process were evaluated to improve manufacturing efficiency. Finally a GFRP rebar with enhanced material properties and less expensive than the GFRP rebar currently sold in the market was manufactured and evaluated for its application possibility in construction fields.

Structural Integrity Evaluation of Mechanically Fastened FRP Beams Under the Effects of Sustained Loads and Environments (지속하중과 환경영향을 받은 MF-FRP 보강보의 구조건전성 평가)

  • Lee, Jae-Ha;Kim, Woo-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Mechanically fastening FRP (MF-FRP) strips using nails and anchors, has been shown to provide a more ductile behavior to the strengthened structural element than using bonded FRP. To further advance the state of the knowledge on this strengthening method, the current study examined environmental effects for six months on MF-FRP beams. Reinforced concrete beams strengthened with mechanically fastened FRP strips and subjected to sustained loads for six months were exposed to outdoor weather and constant high temperatures ($40^{\circ}C$). For comparison, the behavior of RC beam with and without sustained loads was evaluated. Results from flexural tests did not show any significant degradation or change of failure mode as a result of sustained load and of environmental effects such as high temperatures and outdoor weather over a period of six months. Failure of the beams was governed by FRP delamination followed by concrete crushing as not much load applied to the nail and anchors because of slip effects.

Optimal strengthening in RC Hollow Slab Bridges using ${\mu}$-GA (${\mu}$-GA에 의한 RC 중공슬래브교의 최적보강)

  • Choi, Se-Hyu;Park, Kyung-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.169-178
    • /
    • 2010
  • In this study, the optimal strengthening by micro genetic algorithm(${\mu}$-GA) method is proposed for improvement of load-carrying capacity of RC hollow slab bridges using external prestressing. The Qeen-post type and King-post type are considered for the optimal strengthening. The type for optimal strengthening, deviator, areas of tendons and the number of anchor are calculated by ${\mu}$-GA. The objective function is constituted with dimensionless cost of tendon and steel for optimal strengthening. The constraints are formulated by design specification for bridges and anchors. The validity of this study is presented by analysis of the results after the optimal strengthening of the RC hollow slab bridge.

Performance Evaluation of Structure Strengthening Using Sprayed FRP Technique (분사식 FRP공법을 이용한 구조물 보강 성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.126-136
    • /
    • 2009
  • The sprayed FRP strengthening technique is combining the Glass fiber and Polyester resin in open air and spraying randomly at concrete's surface with high-speed compressed air. Then it strengthens the structures with a new technique evaluated the structural performance. We applied it to concrete beam and tested for flexural strength, depended on Korea Standard(KS F 2408). Then based on the result of flexural strength, the properties were proposed that applying to structures. Based on the experiment, we have evaluated structural performance by the experiment. 1/5 scale prestressed concrete I-beam were made by Korean Highway's typical drawing in 1993. With these test results, 49.8% increased in flexural strength, improvement of the behavior of serviceability state, and strengthening was surely effective for controlling deflection and crack of structure. Consequently, it can be summarized that Sprayed FRP technique has prospect to improve the performance of structure.

Buckling Test and Non-linear Analysis of Aluminium Isogrid Panel (알루미늄 lsogrid 패널의 좌굴시험 및 비선형 해석)

  • Yoo, Joon-Tae;Lee, Jong-Woong;Yoon, Jong-Hoon;Jang, Young-Soon;Yi, Yeong-Moo;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.35-40
    • /
    • 2005
  • There are many methods to reinforce the cylindrical structure for light weight design like skin-stringer and semi-monocoque. Isogrid is one of the reinforced structures to improve buckling load. Isogrid has many advantages for complex load case, internal pressure and concentrated load.In this paper, compressive buckling test and non-linear FE analysis of the isogrid panel are described. Diameter of panel is 2.4m and thickness of plate is 11.43mm. The angle which the panel accomplish is about 70 degrees and, its height is about 660mm. Local buckling, global buckling and variation of stiffness after local buckling were observed during buckling test of the panel. MSC/MARC is used for non-linear FE analysis. When analysis, initial imperfection of panel which occurred during plastic forming is considered. The results of analysis for buckling mode and buckling load have good agreements with test.

Analytical Research on Flexural Strengthened by FREP of RC Structure (RC 구조물의 FREP 휨 보강을 위한 해석적 연구)

  • Kang Sung-Hoo;Park Sun-Joon;Kim Min-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.493-500
    • /
    • 2004
  • FREP(Fiber Reinforced Epoxy Panel) are used for strengthening the damaged RC beams due to its good tensile strength, low weight, resistance to corrosion, and easy applicability. This study sets up structure equation for FREP bending reinforcement before and during the usage of RC beam. It finds the difference and finds the mechanical characteristics of rip-off failure that is caused by stress concentration in reinforcement material cutting part to estimate the performance of bending reinforcement. The result of this research can be summarized as two main consequences. The main failure of FREP reinforced concrete beam is rip-off failure and it evaluated rip-off failure of RC reinforcing bean based on the test and analytical conditions of this study. It found that stress was concentrated due to rapid change of bending rigidity in reinforced cutting part as a result of excessive reinforcement thickness of FREP. It resulted in rip-off failure. It means that it should evaluate the rip-off failure when designing reinforcement. It analyzed the reinforcement effect according to reinforced period for FREP. It found that reinforcement effect of P-Type that was reinforced during the usage decreased compared to I-Type that was reinforced before the usage. So when reinforcing a existing structure that is being used, it should consider the stress that is produced due to the fixed load.

Geosynthetic Embankment Stability on Soft Ground Considering Reinforcement Strain (보강재의 변형을 고려한 연약지반위 섬유보강성토제체의 안정해석)

  • 이광열;정진교;황재홍;홍진원;안용수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.867-874
    • /
    • 2003
  • 섬유보강재를 이용한 성토제체의 설계에서 기존의 방법은 보강재의 변형을 무시하고 흙의 변형만을 중요시하고 있다. 보강재에 의해 보강된 성토제체의 파괴면에서 보강재와 흙의 거동은 초기응력단계에서는 일체거동현상을 나타내지만 응력의 증가에 따라 변형량에서 차이를 보인다. 이러한 문제는 토공구조물의 보강재를 설계하는데 있어서 중요한 요소로서 보강효과에 큰 영향을 미칠 수 있다. 본 연구에서는 연약지반 위에 PET Mat로 보강하여 축조한 성토제체에서 보강재와 흙의 응력 - 변형거동을 수치해석을 통하여 분석하였다. 연구결과, 파괴면에서 보강재의 변형은 보강재의 인장강도 크기에 따라 큰 차이를 보이고 있다. 외부하중에 의해 보강재에 발생하는 최대응력은 보강재의 항복인장강도를 초과하지 않으며, 보강재에 발생하는 응력이 성토체에서 발생하는 응력이상일 때 이상적인 것으로 나타났다. 또한 제체의 전단파괴에 대한 안전율은 보강재의 항복인장강도가 증가할수록 증가하는데 보강재와 흙의 변형이 일치되는 이후부터는 안전율의 증가율은 거의 미미한 것으로 나타났다.

  • PDF

Seismic Retrofit of RC Exterior Beam-Column Joints Strengthened with CFRP (CFRP를 이용한 비내진 철근콘크리트 외부 보-기둥 접합부의 내진 보강)

  • Kim, Min;Lee, Ki-Hak;Lee, Jae-Hong;Woo, Sung-Woo;Lee, Jung-Weon
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.729-736
    • /
    • 2006
  • It has been shown that many Reinforced Concrete(RC) structures designed without seismic details have experienced brittle shear failures in the beam-column joint area and resulted in large permanent deformations and structural collapse. In this study, experimental investigations into the performance of exterior reinforced concrete beam-column joints strengthened with the carbon fiber-reinforced polymer(CFRP) under cyclic loading were presented. The CFRP has been applied by choosing different combinations and locations to determine the effective way to improve structural performances of joints. Eight beam-column joints were tested to investigate behaviors of each specimen under cyclic load and to compare performances of seismic retrofit. According to the experimental study, the retrofit strengthened with the CFRP provides significant improvements of flexural capacity and ductility of beam-column joints originally built without seismic details.

An Experiment Study on Verification for the Performance of Seismic Retrofit System Using of Dual Frame With Different Eigenperiod (진동주기가 다른 듀얼프레임을 이용한 내진보강시스템의 성능검증을 위한 실험적 연구)

  • Oh, Sang-Hoon;Choi, Kwang-Yong;Ryu, Hong-Sik;Kim, Young-Ju
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.91-100
    • /
    • 2018
  • The new seismic retrofit system in study propose is the Dual system, which aims to be applied to the seismically vulnerable low-story buildings. The Dual system is composed of existing structure, external retrofit frame and hysteretic steel dampers installed between former two components. The Dual system dissipates the energy by plastic deformation of steel damper caused by relative displacement due to the differences in stiffness, weight, and eigenperiod of each components. The dynamic test with shaking table was performed to verify the seismic performance of the proposed Dual system. As a result of the dynamic test, it is expected that the Dual system will improve the seismic performance due to the reduction of strain of 56% and the damage reduction of 93%, even though the energy is 1.84 times higher than that of the dual system. And the results of the study are presented as basic data of the study for setting the design range of the dual system.