• Title/Summary/Keyword: 구조벽

Search Result 1,091, Processing Time 0.023 seconds

Structural Effect on Curtailment of Upper Shear Wall in Frame-Shear Wall Structure (골조-전단벽 구조에서 상부 전단벽 미배치의 구조효과)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.18-25
    • /
    • 2016
  • This research purposed to study a structural effect on curtailment of upper shear wall in frame-shear wall structures, using MIDAS-Gen. In this study, the analysis variables were the story number of curtailment of upper shear wall, change of column section in every 2 stories and change of shear wall thickness in every 2 stories. In order to analyse a structural effect on curtailment of upper shear wall in frame-shear wall structures, we studied the distribution of shear force and overturning moment according to curtailment of shear wall, the inflection point of shear wall from shear force/overturning moment and the lateral stiffness. The results of study proposed the quantitative influence that the curtailment of upper shear wall in frame-shear wall structures had on the structural performance such as lateral stiffness. Furthermore, it is verified that the results of study can be very helpful in catching the materials on the structure design for a reasonable frame-shear wall system.

진동기초에서의 진동전파차단

  • Heo, Young
    • Computational Structural Engineering
    • /
    • v.6 no.1
    • /
    • pp.26-29
    • /
    • 1993
  • 진동전파차단효과는 방진구가 가장 좋으나, 기술적인 문제에 의해 방진벽을 설치하는경우에 방진벽에 의한 진동전파차단효과는 여러 연구들에 의해 다음과 같이 요약된다. - 방진벽은 진동원에 가깝게 설치할수록 좋다. - 방진벽과 지반의 강성비가 클수록 방진벽의 진동차단성능은 우수하다. - 콘크리트보다 더 높은 강도의 방진벽도 더 좋은 결과를 나타내지 않는다.

  • PDF

A Study on the Measurement of Wall Shear Rate in the Abdominal Aortic Aneurysm (복부대동맥류 벽 전단변형률 측정에 관한 연구)

  • 오성은;이계한
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.181-187
    • /
    • 2000
  • 동맥의 일부분이 팽창하는 동맥류는 파열로 인한 높은 사망률을 야기한다. 동맥류의 발생 및 파열에는 혈관벽의 구조적 약화와 혈류에 의한 응력이 중요한 역할을 하며, 혈류에 의해 혈관벽에 가해지는 전단응력은 간접적으로 혈관벽 구조를 변화시키고, 직접적으로 혈관벽에 응력을 가하므로 동맥류 파열에 영향을 미치는 중요한 혈류역학적 인자이다. 동맥류가 자주 발생하는 복부대동맥류 모델을 제작하여 정상류와 맥동류 유동에서 광색성 염료를 이용한 유동가시화 방법으로 벽 전단변형률을 측정하였다. 벽전단변형률은 동맥류 내부에서 감소하여 음의 값을 가지며, 동맥류 최대확장부 후부에서 다시 증가하여 확장부가 끝나는 위치에서 동맥 벽에 비해 약 1.5배 정도의 큰 전단변형률 값을 가졌다. 동맥류 최대확장부 후부에서는 벽전단변형률의 방향의 바뀌며, 위치에 따른 전단변형률의 변화가 크게 나타났다. 맥동류 유동에서는 동맥류의 위치에 따라 시간에 따른 벽전단형률 파형이 측정되었다. 동맥류 내부에서는 전단변형률의 크기가 작고 그 방향이 시간에 따라 변화가 심하였으므로 혈관벽의 구조변화가 발생하기 쉬운 지역으로 지목된다. 동맥류 최대 확장부 후부는 위치 및 시간에 따른 전단변형률의 변화가 심하며, 혈관벽 응력이 최대값을 갖는 지역이므로 동맥류의 파열이 발생하기 쉬운 지역으로 예측된다.

  • PDF

Analysis of the Structural Safety of a Wind-Protecting Wall Using ANSYS/CFX (ANSYS와 CFX를 이용한 방풍벽의 구조 안전성 분석)

  • Yum Sung-Hyun;Kim Chul-Soo;Choi Young-Don
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.138-148
    • /
    • 2006
  • This study was carried out to evaluate the structural safety fur both the attached wind-protecting wall in greenhouse and the detached one installed outside. Regarding the attached wind-protecting wall in greenhouse, the analysis was conducted by doing a fluid-structure coupled field analysis using both CFX-5.7 and ANSYS 8.1 and also under the design condition of an instantaneous maximum wind velocity of $30.9m{\cdot}s^{-1}$. Three kinds of the width ranged from 30 to 90cm were considered in this study. With regard to the detached wind-protecting wall, the structural saffty was analyzed under the pressure difference of 1,117 Pa which corresponded to a wind velocity of $50m{\cdot}s^{-1}$ and the analytical results were also compared with theoretical ones. The result showed that there was little difference in the distribution of velocity overall and total pressure on the lateral side according to the width of the attached wind-protecting wall, but greenhouse with wind-protecting widths of 30 to 60cm has been reinforced to the extent of about 11% when compared with the case of being without the wall. The result also showed that the detached wind-protecting wall with a main-column interval of 3m was not stable so that it was necessary for the detached wind-protecting wall to be adequately reinforced to secure structural stability. Finally, there was great difference between analytical results and theoretical studies. The difference meant that there was some possibility of including errors when a theoretical study was done in three dimensional structure.

Development of Efficient Seismic Analysis Model using 2D T-Shape Rigid-body for Wall-Frame Structures with a Central Core (이차원 T형강체를 이용한 중심코어를 가진 전단벽-골조 구조물의 효율적인 지진해석모델 개발)

  • Park, Yong-Koo;Lee, Dong-Guen;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.9-17
    • /
    • 2013
  • In this study, an efficient analytical model for the dynamic analysis of tall buildings with a shear wall-frame structural system has been proposed. A shear wall-frame structural system usually consists of a core wall showing flexural behavior and a frame presenting shear behavior. Therefore, the deformed shape of the shear wall-frame structural system is shown by the combination of flexural mode and shear mode. These characteristics should be considered when an efficient analytical model is developed. To this end, the effect of shear wall and frame on the dynamic behavior of a tall building with a dual system has been separately investigated. In this study, the structural characteristics of a separated individual shear wall model and the frame model without shear wall has been evaluated. In order to consider the effect of the shear wall in the frame model without shear wall, a rigid body was used instead of the shear wall. Each equivalent model for the separated shear wall part and frame part has been independently developed and two equivalent models were then combined to create an efficient analytical model for tall buildings with a shear wall-frame structural system. In order to verify the efficiency and accuracy of the proposed method, time history analyses of tall buildings with a shear wall-frame system were performed. Based on analytical results, it has been confirmed that the proposed method can provide accurate results, requiring significantly reduced computational time and memory.

Seismic Performance Evaluation of Hexagonal Blocks Infilled RC Frames (육각형 블록을 이용한 채움벽 RC 골조의 채움벽 내진성능평가)

  • Chang, Kug Kwan;Seo, Dae Won;Ko, Tae Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.116-124
    • /
    • 2011
  • RC frames with unreinforced masonry infiledl walls are common in worldwide. Since infilled walls are normally considered as non-structural elements, their presence is often ignored by engineers. In this study, to improve the seismic performance of masonry walls, hexagonal block was developed and the influence of masonry infilled wall on the seismic performance of reinforced concrete(RC) frames that were designed in accordance with current code provisions without the consideration of earthquake loadings are investigated. Two 1/2 scale, single story, single bay, frame specimens were tested. The parameters investigated included that the strength of infilled wallls with respect to that of the lateral load history. The experimental results indicate that infilled walls can significantly improve the lateral stiffness and strength of RC frames. The lateral loads developed by the infilled frame specimen is higher than that of the bare frame. It also indicates that infilled walls can be potentially used to improve the performance of existing nonductile frames. For this purpose. methods should be developed to avoid irreparable damage and catastrophic failure.

Development of Efficient Seismic Analysis Model using 3D Rigid-body for Wall-Frame Structures with an Eccentric Core (삼차원 T형강체를 이용한 편심코어를 가진 전단벽-골조 구조물의 효율적인 지진해석모델 개발)

  • Park, Yong-Koo;Lee, Dong-Guen;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.19-28
    • /
    • 2013
  • In a shear wall-frame structural system, the structural response is determined by the interaction between the shear wall in bending mode and the frame in shear mode. In order to effectively consider these characteristics of a shear wall-frame structure, the simplified numerical model using the T-shape rigid body was suggested in the previous study. Based on the previously proposed model, an efficient numerical model for a wall-frame structure with an eccentric core has been proposed in this study. To this end, the previously proposed 2D model is extended to the 3D model and it is enhanced by considering torsion effects. As a result, the enhanced model can be applied to the analysis of a wall-frame structure with an eccentric core as well as a centric core.

Efficient Three Dimensional Analysis of High-Rise Shear Wall Building with Openings (개구부가 있는 고층 벽식 구조물의 효율적인 3차원 해석)

  • 김현수;남궁계홍;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.351-365
    • /
    • 2002
  • The box system that is composed only of reinforced concrete walls and slabs we adopted on many high-rise apartment buildings recently constructed in Korea. And the framed structure with shear wall core that can effectively resist horizontal forces is frequently adopted for the structural system for high-rise building structures. In these structures, a shear wall may have one or more openings for functional reasons. It is necessary to use subdivided finite elements for accurate analysis of the shear wall with openings. But it would take significant amount of computational time and memory if the entire building structure is subdivided into a finer mesh. An efficient analysis method that can be used regardless of the number, size and location of openings is proposed in this study. The analysis method uses super element, substructure, matrix condensation technique and fictitious beam technique. Three-dimensional analyses of the box system and the framed structure with shear wall core having various types of openings were performed to verify the efficiency of the proposed method. It was confirmed that the proposed method have outstanding accuracy with drastically reduced time and computer memory from the analyses of example structures.

An Experimental Study on the Structural Performance of Lightly Reinforced Concrete Frame Retrofitted with Concrete Block and Cast-In Place Infilled Wall (블록 끼움벽과 현장타설 끼움벽으로 보강된 비내진 상세 철근콘크리트 골조의 구조성능에 관한 실험적 연구)

  • Choi, Chang-Sik;Lee, Hye-Yeon;Kim, Sun-Woo;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.199-206
    • /
    • 2005
  • In many other countries framed structures with inadequate lateral strength and stiffness have been strengthened by providing reinforced concrete infilled wall. There is a general agreement among researchers those infilled walls have 3-5times greater lateral strength compared with bare frame. The main objective of this research is to investigate the behavior and strength of reinforced concrete frames infilled with concrete block and cast-in-place reinforced concrete panels used for strengthening the structure against seismic action. For this purpose three 1/3 scale, one-bay, one-story reinforced concrete infilled frames were tested under reversed cyclic loading simulating the seismic effect. The results indicate that infilled walls increase both strength and stiffness significantly under lateral loads. Especially Strength capacity and initial stiffness of CIP infilled wall increased 3.8 times and 6.6 times higher than lightly reinforced concrete frame.

Stiffness-based Optimal Design of Shear Wall-Frame Structure System using Sensitivity Analysis (민감도 해석을 이용한 전단벽-골조 구조시스템의 강성최적설계)

  • Lee Han-Joo;Kim Ho-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.1 s.71
    • /
    • pp.63-71
    • /
    • 2006
  • This study presents the effective stiffness-based optimal technique to control Quantitatively lateral drift for shear wall-frame structure system using sensitivity analysis. To this end, the element stiffness matrices are constituted to solve the compatibility problem of displacement degree of freedom between the frame and shear wall. Also, lateral drift constraint to introduce the approximation concept that can preserve the generality of the mathematical programming and can effectively solve the large scaled problems is established. And, the section property relationships for shear wall and frame members are considered in order to reduce the number of design variables and differentiate easily the stiffness matrices. Specifically, constant-shape assumption which is uniformly varying in size during optimal process is applied in frame structure. The thickness or length of shear wall can be changed depending on user's intent. Two types of 20 story shear wall-frame structure system are presented to illustrate the features of the stiffness-based optimal design technique.