• Title/Summary/Keyword: 구조물 방호

Search Result 82, Processing Time 0.029 seconds

Evaluation of the Protection Performance of SB4 Class Concrete Barrier with Anti-Glare Function (SB4 등급 방현기능 콘크리트 방호울타리의 방호성능 평가)

  • Joo, Bongchul;Hong, Kinam;Yun, Junghyun;Lee, Jaeha;Kim, Jungho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.93-102
    • /
    • 2021
  • This paper describes the process of developing a concrete median barrier of SB4 grade with anti-glare function. The development section has a height and width of 1,270mm and 560mm, respectively. A wire mesh is placed in the center of the cross section to improve the protection performance. Collision analysis predicted that this section satisfies the strength and occupant protection performance, and that no damage to the barrier occurs. In the actual collision test, it was confirmed that this section satisfies the strength and occupant protection performance. However, damage was observed on two concrete barrier when the truck crashed. In order to improve the accuracy of the collision analysis of the concrete barrier in the future, it is considered that a study on the model development and continuous collision analysis method for domestic commercial vehicles should be carried out.

Basic Study on Fiber Composite Panel Production for Impact·Blast Resistant (방호·방폭 보강용 복합섬유 패널 제작을 위한 기초연구)

  • Kim, Woonhak;Kang, Seokwon;Yun, Seunggyu
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.235-243
    • /
    • 2015
  • The methods to improve the protection and explosion-proof performance of concrete structures include the backside reinforcement or concrete material property improvement and the addition of structural members or supports to increase the resistance performance, but they are inefficient in terms of economics and structural characteristics. This study is about the basic study on the fiber composite panel cover, and the nano-composite material and adhesive as the filler, to maximize the specific performance of each layer and the protection and explosion-proof performance as the composite panel component by improving the tensile strength, light weight, adhesion and fire-proof performances. The fiber composite panel cover (aramid-polyester ratios of 6:4 and 6.5:3.5) had a 2,348 MPa maximum tensile strength and a 1.8% maximum elongation. The filler that contained the nano-composite material and adhesive had a 4 MPa maximum tensile shear adhesive strength. In addition, the nano-composite filler was 30% lighter than the normal portland cement

A Study on Material Properties of Composite Panel for Impact·Blast Resistance (방호·방폭 보강용 복합패널의 재료특성에 관한 연구)

  • Kim, Woonhak;Kang, Seokwon
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.373-380
    • /
    • 2016
  • In order to develop composite fiber panels that can maximize the protection and blast resistance of the existing structures by improving lightweight, high-strength and fireproof performances of the single layer material of precast panels, the basic properties of the inner and outer covers that are mixed with aramid fibers (AF) and polyester fibers (PF) were evaluated in this study. Also, a basic study was performed on the performance of composite fiber panels by testing Nano-sized composite materials that are lightweight and excellent in fire resistance for their compressive strength, bending strength and tensile strength.

Study on Cracking Causes and Patterns in Median Barrier and Guardrail Concrete in RC Bridge (콘크리트 교량 방호벽의 균열원인 및 패턴 분석에 대한 연구)

  • Choi, Se-Jin;Choi, Jung-Wook;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.19-26
    • /
    • 2014
  • Concrete guide rail and median barrier are an attached RC member, however they are vulnerable to cracking due to slip form construction and large surface of member. In this study, causes and pattern of cracking are analyzed through assessment and NDT (Non-Destructive Technique) evaluation for concrete guide rail and median barrier on highway structure. For this work, analysis on drying shrinkage and hydration heat are performed considering installation period, and plastic shrinkage is also analyzed considering their environmental conditions. From the evaluation, plastic settlement around steel location, drying/ plastic shrinkage, and aggregate segregation are inferred to be the main causes of cracking in the structures. The crack causes and patterns are schematized and techniques of crack-control are suggested. Furthermore concrete guide rail/ median barrier in the bridge on the sea are vulnerable to cracking at early age so that special attentions should be paid at the stages of material selection and construction.

A Basic Research for Ductile Hybrid Fiber Composite Panels of Materials (유사연성 하이브리드 섬유를 이용한 복합패널의 구성 재료 기초 연구)

  • Kim, Woonhak;Kang, Seokwon;Hwang, Seongwoon
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.388-395
    • /
    • 2014
  • In this paper, usability and use force on the structure and does not have a big impact on the development of existing materials developed using materials to their full impact/blast resistant Complex configuration on the panel that can be implemented. Each material of the characteristics so that they can exert in layers of layer formed panels in layers. Structure of the general structure is to keep strength and endurance, maintenance and minimize the damage can be utilized for knee brace to do basic research, for creating the panel.

Development and Verification of Simplified Collision Model for Pile Protective Structures (파일형 선박충돌방호공에 대한 간이충돌모델의 개발과 검증)

  • Lee, Gye Hee
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.1
    • /
    • pp.7-12
    • /
    • 2016
  • In this study, a simplified collision model of pile protective structures against a navigation vessel was proposed and verified. The model of pile protective structure were composed by two plastic hinges at below of cap slab and the inside of ground. A nonlinear equation of motions was developed in consideration of the kinematic energy, potential energy and deformation energy in collision event. The developed simplified model were verified by the precise finite element collision analysis of the vessel and the protective structure.

사용후핵연료 중간저장(건식형태)시설의 구조 및 설비기준 개발

  • 김영상;이상국
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.247-252
    • /
    • 1996
  • 사용후핵연료 건식 중간저장시설은 설계수명기간 동안 방사능 차폐, 냉각, 보호 등과 같은 주요 기능이 확실히 보장되도록 설계 및 유지·관리되어야 한다. 이러한 주요 기능은 여러가지 설계하중 하에서 구조물의 거동을 정확히 파악한 결과를 설계에 반영함으로써 보장된다. 본 연구에서는 구조물의 건전성을 보장할 수 있는 기능적 측면과 구조적 측면에서 고려되어야 할 항목 및 내용을 국외에서 적용되고 있는 기술기준을 토대로 하고 풍하중, 홍수방호, 내진설계, 열하중해석, 철근콘크리트 및 강구조물, 기초지반과 같은 세부항목에 대한 해석 및 설계의 연구결과를 추가하여 국내 원자력법령과 시행령에 부합되는 사용후핵연료 건식중간저장시설의 구조 및 설비기준을 개발하였다.

  • PDF

Evaluation of Ballistic Performance of Ceramic-Tile-Inserted Metal Block (세라믹 타일이 삽입된 금속 블록의 최적 방호구조 연구)

  • Lee, Seunghwan;Lee, Minhyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.3
    • /
    • pp.297-304
    • /
    • 2016
  • A numerical simulation has been performed for the penetration of a long-rod penetrator into a metal block (ceramic-tile-inserted 4340-steel plate). The impact velocity is 1.5km/s at a normal incidence angle. The first two validations are conducted for a semi-infinite block measuring the depth of penetration (DOP). The material model of ceramic is the JH-2 (Johnson-Holmquist) model. The predicted DOP values are in close agreement with the experimental data. Then, the primary simulation is performed by varying the position of the confined ceramic tile for three types of thickness of ceramic tile. The residual velocity, residual mass and residual kinetic energy of the long-rod are obtained from the simulation. Based on these predicted values, the trend of the ballistic performance of the protective structure is estimated. In addition, the mass efficiency is calculated in order to determine the performance of the ceramic-tile-inserted metal block. Finally, the optimum protective structure is identified.

Impact Resistance Characteristics of Cementitious Composites Subjected to High-velocity Projectiles with Reinforcement Types (고속 발사체와 충돌한 시멘트복합체의 보강재 종류에 따른 내충격 특성 연구)

  • Seok, Won-Kyun;Kim, Young-Sun;Lee, Yae-Chan;Nam, Jeong-Soo;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.261-272
    • /
    • 2023
  • This research concentrates on the potential explosion hazards that could arise from unforeseen accidents in the rapidly proliferating hydrogen refueling stations and Energy Storage System(ESS) facilities. It underscores the pivotal role of structural protection technology in alleviating such risks. The research contributes primary data for the formulation of structure protection design by assessing the impact resistance across various reinforcement techniques used in cement composites. The experimental results elucidate that reinforced concrete, serving as the quintessential structural material, exhibits a 20% advancement in impact resistance in comparison to its non-reinforced counterpart. In situations typified by rapid loads, such as those seen with high-velocity impacts, the reinforcement of the matrix with fibers is demonstrably more beneficial than local reinforcement. These insights accentuate the importance of judiciously choosing the reinforcement method to augment impact resistance in structural design.