• Title/Summary/Keyword: 구속

Search Result 2,419, Processing Time 0.03 seconds

A Formulation of the Differential Equation on the Equations of Motion and Dynamic Analysis for the Constrained Multibody Systems (구속된 다물체 시스템에 대한 운동 방정식의 미분 방정식화 및 동역학 해석)

  • 이동찬;이상호;한창수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.154-161
    • /
    • 1997
  • This paper presents the method to eliminate the constraint reaction in the Lagrange multiplier form equation of motion by using a generalized coordinate driveder from the velocity constraint equation. This method introduces a matrix method by considering the m dimensional space spanned by the rows of the constraint jacobian matrix. The orthogonal vectors defining the constraint manifold are projected to null vectors by the tangential vectors defined on the constraint manifold. Therefore the orthogonal projection matrix is defined by the tangential vectors. For correcting the generalized position coordinate, the optimization problem is formulated. And this correction process is analyzed by the quasi Newton method. Finally this method is verified through 3 dimensional vehicle model.

  • PDF

Dynamics Modeling of Plate Treated with Active Constrained Layer Damping (능동 구속층 감쇠 처리된 판의 동적 모델링)

  • Park, C.H.;Kim, W.C.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.124-143
    • /
    • 1997
  • 본 논문은 능동 구속층 감쇠(active constrained layer damping) 처리된 관의 동적 모델링과 정식화를 제시한다. 판의 운동방정식은 Hamilton정리를 이용하여 전개된 판, piezoelectric film 및 점탄성층의 운동방정식을 조합하므로서 유도된다. 이 운동방정식은 외부인가전압의 영향하에서 적층판의 해석적 모델을 제공할 뿐만이 아니라, 판 구조내에서 진동에너지를 감소시킬 수 있는 전단층의 효과에 대한 변위관계식을 나타낸다. 그리고 운동방정식에 대응하는 경계조건도 유도되었다. 또한 판과 능동구속층감쇠계의 동특성을 설명하기 위한 유한요소모델이 유도되었다. 이 모델의 타당성을 실온조건에서 실험적으로 입증하였다. 개발된 이론 및 실험적인 결과들은 판과 능동구속층 감쇠계가 구조진동의 감쇠를 위한 매우 유효한 수단으로 사용될 수 있음을 나타내었다.

  • PDF

Evaluation on Water Vapor Pressure and Restrained Stress of Concrete by Ring-Type Restrained Condition (링형 강관 구속 조건에 의한 콘크리트의 수증기압력과 구속응력 평가)

  • Kim, Do-Yeon;Kim, Gyu-Yong;Lee, Sang-Kyu;Son, Min-Jae;Baek, Jae-Wook;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.27-28
    • /
    • 2018
  • In this study, water vapor pressure and restrained stress were evaluated by ring-type restrained condition for compressive strength 60 and 80MPa concrete. Experimental results show that the 80MPa concrete has higher water vapor pressure and restraint stress than the 60MPa concrete, resulting in spalling occurrence. It is because, the higher the compressive strength of the concrete, the more dense the internal structure is formed.

  • PDF

Experimental Study on Concrete Steel Circular Tubes Confined by Carbon Fiber Sheet under Axial Compression Loads (탄소섬유쉬트로 구속된 콘크리트충전 원형강관기둥의 단조압축실험)

  • Park, Jai-Woo;Hong, Young-Kyun;Hong, Gi-Soup;Choi, Sung-Mo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.61-71
    • /
    • 2009
  • This paper presents the results of an experiment comparing the current circular CFT columns and circular CFT columns that were additionally confined by carbon fiber sheets (CFS) under axial loading. The main experimental parameters are the numbers of CFS layers and the diameter-to-thickness ratio. 10 specimens were prepared according to the experimental parameter plans, and axial compression tests were conducted. From the tests, the failure procedure, load-axial deformation curve, maximum axial strength, and deformation capacity of the CFT columns and confined CFT columns were compared. The test results showed that the maximum axial strengths of CFT columns additionally confined by CFS are increased higher than those of the current CFT columns, and that local buckling can be delayed due to the confinement effect of CFS.

Strength of Square Shaped CFT Stub Column Considering the Confining Effect of Concrete (콘크리트 구속효과를 고려한 정사각형 CFT단주의 강도)

  • Hwang, Won Sup;Kim, Dong Jo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.813-822
    • /
    • 2002
  • The squash strength and design strength are smaller than the experimental strength of square shaped concrete-filled steel tubular columns in a short concentrically loaded column. This study presents an evaluation procedure accounting for the confining effect of concrete. For the purpose of evaluating a confining effect of concrete, the 3D finite element method was used. The influence of parameters, width-thickness ratios, strength of the concrete and the yield strength of the steel, were examined. The suggested evaluation procedure that assembled three parameters was compared with previous experimental results. Also, the tendency of the confining effect of concrete was examined in the three types of load application.

Behavior and Ultimate Strength of Restrained Reinforced Concrete Columns (구속 철근콘크리트 기둥의 극한강도와 거동해석)

  • Park, Jae Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.23-31
    • /
    • 1992
  • In this study, Behavior of Eccentrically Loaded Restrained Concrete Slender Columns are investigated the continuation. The paper is : nonlinear constitutive relations of reinforced concrete columns are formulated, the multivariable nonlinear equation formulated in this study is solved by the incremental iterative method, the solution scheme is suitable for computer application, the proposed method bas been compared with the numerical examples and other research results and is shown to be in good agreement Accordingly, the objectives of this investigation are to use the method developed to conduct a parametric study of the different variable (Rotational Restraints,Ratio of End Restraints. End Eccentricity, Ratio of End Eccentricities,Lateral Restraint, Concrete Strength, Ratio of Reinforcement. Yield Point of Reinforcement) influencing the behavior and the ultimate strength for columns. Chosen values for different parameters and their variations are based on values encountered in practice and on results of other analylitical studies.

  • PDF

Experimental Study on Flexural Capacity of Circular Concrete Beam Confined by Carbon Fiber Tubes (탄소섬유관으로 구속된 무근 원형 보의 휨성능에 관한 실험적 연구)

  • Lee, Kyoung-Hun;Hong, Won-Kee;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.1 s.53
    • /
    • pp.37-43
    • /
    • 2007
  • Experiments for circular unreinforced concrete beams confined by carbon fiber tubes (CFT) made of carbon fiber sheets were performed. Selected test parameter was thickness of carbon fiber tube: 1.5mm (3 layers), 2.0mm (4 layers), 2.5mm (5 layers), and 3.0mm (6 layers). Based on the test results, an equation for estimating moment capacity of the circular beams confined by carbon fiber tubes was proposed. Comparison results showed good agreement up to 2.5mm (5 sheets) of the CFT thickness.

Dynamic Deformation Characteristics of Cohesionless Soils in Korea Using Resonant Column Tests (공진주시험을 이용한 국내 비점성토 지반의 동적변형특성)

  • 김동수;추연욱
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.5
    • /
    • pp.115-128
    • /
    • 2001
  • 본 논문에서는 반복하중이나 지진하중을 받는 지반-구조물 시스템의 설계에 필수적인 변수인 전단탄성계수와 감쇠비에 대한 연구를 국내에 존재하는 비점성토 지반에 대하여 수행하였다. 국내 퇴적토지반 및 풍화토지반에서 채취된 자연시료와 입도분포를 조정하여 제작한 시료를 포함하여 총 60개의 시료에 대하여 20kPa에서 500kPa의 구속응력 범위에서 공진주 시험을 수행하고, 이를 조립질 사질토, 실트 및 실트질 모래, 풍화토의 3개의 그룹으로 나누어 결과를 정리하였다. 저변형률 영역의 변형특성인 최대전단탄성계수와 최소감쇠비에 대하여 구속응력의 영향을 확인하였다. 최대전단탄성계수를 예측하는 경험식을 3개의 그룹별로 제안하였다. 최소감쇠비는 구속응력에 따른 분포영역을 제시하였다. 세립분이 적은 조립질 사질토의 경우, 비선형 변형특성이 구속응력의 영향을 뚜렷이 받고 있어 이를 주요한 변수로 고려하여 대표곡선과 분포영역을 제안하였다. 구속응력의 영향을 적게 받는 실트 및 실트질 모래와 풍화토는 구속응력에 관계없이 대표곡선과 분포영역을 제안하였다. 제안된 각 시료의 대표곡선과 기존의 Vucetic-Dobry와 Seed-Idriss가 제안한 곡선과 비교하였다. 본 논문의 연구결과는 국내지반의 비점성토 지반에 대한 지진해석이나 동하중을 받는 시스템의 해석시 유용하게 사용될 것으로 판단된다.

  • PDF

A Study on Properties of Mechanical Behaviors of Concrete Confined by Circular Steel Tube (원형강관으로 구속된 콘크리트의 역학적 거동 특성에 관한 연구)

  • 박정민;김화중
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.199-210
    • /
    • 1995
  • We could say that the concrete filled steel tube structure is superior in the vlew of various structure properties as to promote improvement of structural capacity to dtmonstrate heterogeneous material properties interdependently. The compressive strength is increased by putting to tri axial stress because lateral expansion of concrete 1s confined by the steel tube, when concrete conflned by steel tube fall under centric axial load. Also, it have an advantage that decreasr of load carrying capacity 1s small, not occuring section deficiency due to protect falling piienornonon by co~nprrssion fallurc of concrete. So this study investigated for structural behaviors yroprrtiex of concwir. confined by steel tube throughout a series of experlmerit with kcy parxncter, such as diameter-to-thickness(D / t) ratio, strength of concrete as a study on properties of structural behaviors of confined concrete confined by circular steel tube( tri axial stress). Frorn the expcrment results, the obtained results, are surnrnarised as foliow. (1) The restraint effect of concrete by steel tube was presented significantly as the D /t ratio of steel tube and the strength of filled concrete decrease, and the confined concrete by circular steel tube was increased respectively twice as much as 4-7 in deformation capacity at the ultimate strength ,compared with those of non-confined concrete, so expected to increase flexible effect of concrete. (2) The emprical formula to predict the ultimate capacity of confined concrete by steel tube and concrete filled steel tube column using restraint coefficient of concrete were proposed.

A Study on the Development of Flat-Ring Type Restrained Test Method and Performance Evaluation for Evaluating Shrinkage Cracking Properties of Concrete in Early Age (콘크리트 초기 수축균열특성 평가를 위한 판상-링형 구속시험방법의 성능평가에 관한 연구)

  • Kim, Gyu-Yong;Choi, Hyeong-Gil;Lee, Eui-Bae;Nam, Jeong-Soo;Han, Min-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.188-196
    • /
    • 2009
  • In Concrete, shrinkages occur like plastic shrinkage and drying shrinkage in the early age because of evaporation and transfer of moisture. Within the country, the crack test standardized by KS is used to test the drying shrinkage of the concrete by using the restricted drying shrinkage of Dumbbell type mold, but this test is for the cracking-point and the restricted shrinkage stress. Thus it is difficult to valuate the crack quantitative test. In this study, it is intended to develop the Flat-ring type restrained test method for the shrinkage deformation movement of the concrete and to provide the quantitative data for evaluating the cracks in concrete. And it suggest the proper specimen diameter and quantitative test method about shrinkage crack properties on Flat-ring type restrained test method. And Verified the suitability.