• 제목/요약/키워드: 구멍확대량

Search Result 8, Processing Time 0.021 seconds

Structural Safety Analysis on Crack Propagation in Compact Tension Specimen (소형 인장 시험편 내의 크랙 전파에 대한 구조 안전해석)

  • Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • In case eccentric load is applied at compact tension specimen, the propagation behavior due to existence or nonexistence of hole, numbers and positions of holes near crack is investigated in this study. Strain energy, displacement and stress happened in specimen are examined through simulation analysis. And stress intensity factor is obtained by the basis of strain energy and deformation. When defect or hole exists in structure, the possibility of fracture can be thought to be verified by using the study result.

A Study on the Deep Hole Drilling for Refractory Metals - STS type BTA drilling for SKD11 high alloy tool steel (난삭재의 심공가공에 관한 연구 (SKD11고합금공구강에 대한 STS타입 BTA드릴 가공))

  • Sim, Sung-Bo;Kim, Chi-Ok;Kim, Cheol-Kyu
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.1 s.31
    • /
    • pp.70-78
    • /
    • 1999
  • 오늘날 기계공업 현장에서 심공드릴가공은 광범위한 응용과 양호한 생산성으로 인하여 그 요구가 증가 되고 있다. 그러므로, 본 연구는 난삭재인 SKD11고합금공구강을 여러가지 절삭조건하에서 BTA드릴가공하여 얻은 실험결과(표면조도, 진직도, 진원도, 원통도, 구멍확대량, 등)를 다루었으며 이들의 이론적 배경과 실험을 비교 분석하였다. 프레스금형 부품과 기계부품으로 사용되고 있는 SKD11고합금공구강은 기계가공이 힘든 난삭재료로서 그 어려움이 크므로 본 연구는 생산현장에 보다 나은 심공드릴가공결과와 관련 지식을 제공 할수 있다고 사료된다.

  • PDF

An Experimental Study on Micro Drilling Using Step Feed (스텝이송방식을 이용한 미세구멍가공에 관한 실험적 연구)

  • Han, J.U.;Won, J.S.;Jung, Y.G.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.12
    • /
    • pp.46-53
    • /
    • 1996
  • Micro drilling is one of the most important machining types and its necessity becomes more and more increasing in the whole field of industry. Micro drilling, however, has few the case of practical application, because it requests high techniques : manufacturing micro drill, treating chip, producting precise hole shape and progressing machining effeciency. Micro drilling has a technical problem: drill breakage from the lack of drill rigdity and the interuption of chip. It is, therefore, essential to select the proper cutting conditions and the step fed for the method solving the lack of rigidity and the interruption of chip. Especially, step feed is very efficient to avoid the breakage of drill, but bring about reducing of cutting efficiency. The study on step feed must be requested more than the present in the near future. The purpose of this paper is to investigate experimentally about cutting conditions which affect on tools and round errors and to estimate about the effect of step feed as well as optimal step feed size to solve the breakage of drill.

  • PDF

An Analytical Study on Crack Behavior Inside Standard Compact Tension Specimen with Holes (구멍들을 가진 표준 CT 시험편 내에서의 크랙 거동에 대한 해석적 연구)

  • Lee, Jung Ho;Cho, Jae Ung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.531-537
    • /
    • 2016
  • The damage and fracture of machine or structure are caused by the crack happened from the defect existed at the inside of material. The properties of crack propagation and growth characteristic must be considered because there are many cases at which these cracks are densely existed. Therefore, this study investigates the fracture property due to the position of crack and hole inside the standard compact tension (C. T.) specimen. When the concentrated load is applied eccentrically at the standard C. T. specimen, the fracture mechanical behavior due to the existence or non-existence and the position of hole near crack is investigated. As the result of analysis study, model 3 (in case of the distance of 2mm on the horizontal direction between the end part and hole as the specimen model existed with one hole near the crack) has the maximum deformation, stress and deformation energy of the most values among three models. As the distance between the crack and hole inside the specimen becomes nearer, the maximum stress becomes higher in cases of three models. Apart from the number of holes, it is seen that the maximum stress becomes higher near the crack when the hole exists near the crack inside the specimen. If the hole inside the machine or the mechanical structure is punctured by using the result of this study, it is thought that the occurred breakage or breakdown can be prevented by reducing the fracture stress happened at the specimen.

A Study on Machinability of SM55C for Deep Hole Drilling (Deep Hole 가공시 SM55C의 절삭성에 관한 연구)

  • 이충일
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.177-182
    • /
    • 1997
  • The purpose of this study is to analyze how tools, guide bush type and the change of cutting speed have effects on the diameter of cutting hole, surface roughness of workpiece and roundness during the deep hole machining of SM55C with solid BTA drill by using BTA drilling system through experiment. Conclusion reached is as follows. (1) The diameter was expanded for 25${\mu}{\textrm}{m}$ at the first section and then was reduced 0${\mu}{\textrm}{m}$ and 15${\mu}{\textrm}{m}$ respectively at the 10m and 20m section comparing to the diameter of tool with respect to the variation of cutting length. (2) It was proved that roughness was below 12S for the whole section of cutting length. (3) The roundness has been below 12${\mu}{\textrm}{m}$. Regarding the polygon phenomenon, it has bee proved that not only uneven number of angle but also even number (quadrilateral, elliptical) of angle were made. (4) Variation of diameter, surface roughness of workpiece and roundness turned out to ve the best at 70m/min of cutting speed, 0.15mm/rev of feed.

  • PDF

A Study on Machinability of SM55C for Deep Hole Drilling (Deep Hole 가공시 SM55C의 절삭성에 관한 연구)

  • 장성규
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.4
    • /
    • pp.56-63
    • /
    • 1998
  • The purpose of this is to analyze experimentally how the change of cutting speed have effects on hole over size of cutting hole, surface roughness of workpiece and roundness during the deep hole machining of SM55C with solid BTA drill using BTA drilling system. Conclusion reached is as follows. (1) The diameter was expanded for 25$\mu$m at the first section and then was reduced 0$\mu$m and 15$\mu$m respectively at the 10m and 20m section comparing to the diameter of tool with respect to the variation of cutting length at 70m/min of cutting speed. 0.15mm/rev of feed. (2) It was proved that roughness was below 8.67$\mu$m for the whole section of cutting length. (3) The roundness has been below 12$\mu$m. Regarding the polygon phenomenon, it has been proved that not only uneven best at 70m/min of cutting speed. 0.15mm/rev of feed.

Development of Venturi System for Microbubble Generation (미세기포 생성을 위한 벤츄리 시스템 개발)

  • Yun, Jeong Eui;Kim, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.10
    • /
    • pp.865-871
    • /
    • 2014
  • This study was conducted with the aim of developing a venturi-type air supply system for a microbubble generator. In order to determine the influence of the varying geometry of the venturi tube on the flow characteristics, a computational fluid dynamics (CFD) simulation was performed using the commercial CFD software ANSYS CFX-15. Furthermore, in order to elucidate the effects of variation in major design dimensions such as the air supply hole size, position of holes, and number of holes on the air supply characteristics, two-phase multiflow CFD analysis was performed. The analysis results showed that the starting point of expansion on the venturi tube with 0.75 is the best hole position and that the air supply hole size and the number of holes are linearly proportional to the amount of air.

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF