• Title/Summary/Keyword: 구리수은막전극

Search Result 2, Processing Time 0.017 seconds

Potentiometric Back Titration of Isoniazid in Pharmaceutical Dosage Forms Using Copper Based Mercury Film Electrode (구리수은막 전극에을 사용한 이소니아자이드의 전위차 역적정)

  • Gajendiran, M.;Nazer, M.M. Abdul Kamal
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.4
    • /
    • pp.620-625
    • /
    • 2011
  • A simple, rapid potentiometric back titration of Isoniazid (INH) in the presence of Rifampicin (RIF) in tablets and syrups is described. The method is based on the oxidation of INH by a known excess of copper (II) ion and the back titration of unreacted copper (II) ion potentiometrically with ascorbic acid using a lab-made Copper Based Mercury Film Electrode (CBMFE). The titration conditions have been optimized for the determination of 1.0-10.0 mg of INH in pure and dosage forms. The precision and accuracy of the method have been assessed by the application of lack-of-fit test and other statistical methods. Interference was not caused by RIF and other excipients present in dosage forms. Application of the method for INH assay in tablets and syrups was validated by comparison of the results of proposed method with that of the British Pharmacopoeia (BP) method using F- and t- statistical tests of significance.

Anodic Stripping Voltammetric Determinations of Zinc, Cadmium, Lead and Copper in Freshwater and Sediment (담수 및 퇴적물에 함유된 아연, 카드뮴, 납 및 구리의 산화전극 벗김 전압전류법 정량)

  • Hahn, Young Hee;Yoo, Jeong Yeon
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.4
    • /
    • pp.180-185
    • /
    • 1997
  • Zinc, cadmium, lead and copper were simultaneously determined by depositing metals at - 1.200 V vs. a Ag/AgCl(sat. KCl) reference electrode for 150 seconds on a hanging mercury drop electrode(HMDE) or a thin mercury film electrode(TMFE), followed by scanning towards anodic direction using differential pulse voltammetric(DPASV) and square wave voltammetric(SWASV) techniques. The linear calibration curves were obtained for four metal ions simultaneously determined by DPASV with a HMDE in the concentration range between 20 and 100 ppb. However, the linear calibration plots were obtained only for $Cd^{2+}$ and $Pb^{2+}$ in the simultaneous determinations with a TMFE in the concentration range up to 100 ppb using DPASV and up to 10 ppb using SWASV. DPASV with a TMFE was about 15 times more sensitive than DPASV with a HMDE for simultaneous determinations of $Cd^{2+}$ and $Pb^{2+}$. SWASV was about 5 times more sensitive than DPASV at a TMFE. Concentrations of zinc in seven different sediment samples determined by DPASV with a HMDE and inductively coupled plasma-mass spectrometry were compared, resulting with an excellent correlation coefficient of 0.9993 and with no significant difference between two methods after t-test.

  • PDF