• Title/Summary/Keyword: 구내스캔

Search Result 24, Processing Time 0.023 seconds

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.

Usage of digital technique to facilitate communication between dentist, dental lab technician, and patients in diagnosis and restoration for maxillary anterior implant: a case report (디지털 기법을 활용한 치과의사, 기공사, 그리고 환자 간의 효과적인 소통을 통한 전치부 임플란트의 진단 및 심미수복 증례)

  • Bang, Haemin;Jang, Woohyung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.42-51
    • /
    • 2022
  • Esthetic restoration of maxillary anterior implant heavily depends on the direction of installation of implant fixture. In patients with malpositioned implant, it is crucial to communicate the limitations of prosthetic outcome with the patient before starting on a restoration. To facilitate the communication, three-dimensional virtual representation by superimposing facial and intraoral digital scans with Computed Tomography (CT, dicom file) was used for visualization of the limitations of prosthesis. Through digital diagnostic wax-up, the profile of right maxillary anterior incisor implant was expected to be protrusive, which the patient was not satisfied with. Since the patient already had done root canal treatment on left maxillary anterior incisor due to previous trauma, a new prosthetic design including both right and left maxillary anterior incisors was presented to the patient. The second design was chosen and his comments were delivered to dental lab. The patient was satisfied with the new prosthesis, aesthetically and functionally.

Digital approach for fabrication of zirconia restoration with optimal gingival adaptation after tooth extraction: A case report (발치 후 지르코니아 보철물 제작에서 최적의 연조직 적합 형성을 위한 디지털 치료 증례)

  • Mai, Hang Nga;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.217-220
    • /
    • 2020
  • Conventionally, when a zirconia fixed dental restoration is planned, the interim restoration is made manually and the final restoration is fabricated by the silicone impression taking at the prosthodontic stage. This conventional workflow does not provide direct relation between interim and final restorations. Moreover, the predictability of the final restoration could be low. Nowadays, the CAD/CAM based restoration fabrication and related digital techniques are developed and being applied in dentistry in multiple ways. This case report introduces a digital workflow for fabricating an optimal gingival adaptation and predictability of monolithic zirconia restoration by using CAD/CAM interim restoration, intra oral scan, and image superimposition technique in a case that required tooth extraction.

Posterior rehabilitation considering mandibular movement with digital facebow transfer and virtual articulator: A case report (디지털 안궁이전과 가상교합기를 이용하여 하악의 운동을 고려한 구치부 수복 증례)

  • Kim, Min-Beom;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.431-441
    • /
    • 2022
  • The digital facebow device records the trajectory of the mandibular movement where it is then reflected on the computer-aided design software, leading to an improvement on treatment outcomes of prosthetic restorations. In this clinical case, using a digital technology, an implant placement and prosthetic restoration were done in a patient who has lost maxillary and mandibular molars. Following an intraoral scan, a surgical stent for implant surgery was fabricated based on digital diagnostic wax-up, and implants were installed. After six months of sufficient osseointegration, customized abutments and the first temporary prostheses were delivered. Then two months later, at an abutment level, an intraoral scan and digital facebow transfer device were used to mount the intraoral scan data on a virtual articulator, and record the mandibular movements. Once the second temporary prostheses were fabricated and delivered on a basis of the mandibular movement, the definitive zirconia prostheses were designed and delivered based on a stabilized occlusion that was duplicated via double scan technique.

3D analysis of soft tissue around implant after flap folding suture (Flap folding suture를 활용한 판막의 고정에 따른 임플란트 주변 연조직 3차원 부피 변화 관찰)

  • Jung, Sae-Young;Kang, Dae-Young;Shin, Hyun-Seung;Park, Jung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.130-137
    • /
    • 2021
  • Purpose: The various suture techniques can be utilized in order to maximize the keratinized tissue healing around dental implants. The aim of this study is to compare the soft tissue healing pattern between two different suture techniques after implant placement. Materials and Methods: 15 patients with 18 implants were enrolled in this study. Simple implant placement without any additional bone graft was performed. Two different suture techniques were used to tug in the mobilized flap near the healing abutment after paramarginal flap design. Digital intraoral scan was performed at baseline, post-operation, stitch out, and 3 months after operation. The scan data were aligned using multiple points such as cusp, fossa of adjacent teeth, and/or healing abutment. After subtracting scan data at baseline with other time-point results, closed space indicating volume increment of peri-implant mucosa was selected. The volume of the close space was measured in mm3. The volume between two suture techniques at three time-points was compared using nonparametric rank-based analysis. Results: Healing was uneventful in both groups. Both suture technique groups showed increased soft tissue volume immediately after surgery. The amount of volume increment significantly decreased after 3 months (P < 0.001). Flap folding suture group showed higher median of volume increment than interrupted suture group after 3 months without any statistical significance (P > 0.05). Conclusion: After paramarginal flap reflection, the raised flaps stabilized by flap folding suture showed relatively higher volume maintenance after 3-month healing period. However, further studies are warranted.

Fabrication of complete denture using CAD-based vertical dimension increase and monolithic disc: a case report (CAD를 이용한 수직 고경 증가와 monolithic disc를 사용한 총의치 수복 증례)

  • Hyeon, Kim;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.242-248
    • /
    • 2022
  • Recently, through the development of CAD/CAM technology, it is also being used for fabricating dentures. Compared to conventional methods, when digital dentures are fabricated, the fabrication process is facilitated, and the number of visits to hospitals is reduced and errors are reduced. In this case, the vertical dimension was increased using a CAD program in a patient who needed vertical dimension recovery due to the use of old dentures, and the final denture was fabricated using a monolithic disc through the milling method. The centric relation was recorded using existing dentures, and using the information from the intraoral scan and the existing denture model scan, a trial denture was fabricated and delivered to the patient to evaluate the midline and occlusion. Based on the evaluation of the trial denture, the final denture was fabricated using a milling method and a monolithic disc, and the final denture showed satisfactory results functionally and aesthetically.

Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report (수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례)

  • Lim, Hyun-jeong;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.

Maxillary complete denture rehabilitation in flabby tissue patient considering of function and stability: A clinical report (Flabby tissue 환자에서 기능과 안정을 고려한 편악 총의치 수복 증례)

  • Choi, Youngkyun;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.422-430
    • /
    • 2021
  • It is very difficult to achieve denture support, stability and retention in single-maxillary complete denture patients with flabby tissue. A 57-year-old male patient was uncomfortable with the existing denture and wanted treatment. The reduction of flabby tissue was confirmed using the treatment denture. Non-pressure impression was obtained using an intraoral scanner during the definitive denture process. This is reported because the resulting denture improved when observing the retention, support and stability of the denture during occlusion.

A case report of single crown restoration using an intraoral scanner for occlusal evaluation (단일 치관 수복 시 구강스캐너를 이용한 교합평가 활용 증례보고)

  • Song, Jun-Beom;Lee, Jong-Hyuk;Ha, Seung-Ryong;Choi, Yu-Sung;Choi, Sun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.341-349
    • /
    • 2021
  • The evaluation of occlusion using digital methods is easier and simpler in terms of recording, comparison, analysis, and objectivity compared to existing methods such as articulating paper and occlusion foil. The purpose of this case report was utilizing the digital method for evaluating occlusion. The occlusion of patient requiring full veneer crown restoration was evaluated using an intraoral scanner (i500, Medit, Seoul, Korea) at every visit. The occlusion was also assessed using conventional articulating paper and a digital occlusal analysis system (Dental prescale II, GC corp., Tokyo, Japan) for comparison. Throughout the treatment process, the intraoral scanner and the conventional articulating paper method showed similar outcomes. The results suggest that the use of digital evaluation system is highly probable in the near future.

Full mouth rehabilitation of a worn dentition using digital guided tooth preparation: a case report (과도한 구치부 마모를 보이는 환자에서 digital guided tooth preparation을 이용한 완전 구강 회복 증례)

  • Kim, Yong-Kyu;Yeo, In-Sung Luke;Yoon, Hyung-In;Lee, Jae-Hyun;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.80-90
    • /
    • 2022
  • With the development of digital dentistry, it is being applied in various ways of dental treatment. This case report presents the definitive prosthesis designed in advance with a re-established vertical dimension and the digital technology, which determined the amount of tooth preparation, in order to preserve as much tooth structure as possible in a patient with pathological wear of the posterior teeth and loss of vertical dimension. For accurate tooth preparation, the guides of the occlusal and axial surfaces were digitally and additively manufactured. Then, aesthetics and anterior guidance were established at the provisional stage. The information of the provisional restoration was delivered to the definitive stage by double scanning. The digital technology, including the virtual planning and the guided tooth removal, produced the definitive restorations satisfactory to both the patient and clinician.