• Title/Summary/Keyword: 교합분석

Search Result 803, Processing Time 0.021 seconds

Comparative Study on Wear Resistance and Hardness of Several Artificial Resin Teeth (수종의 인공 레진 치아의 마모저항성과 경도에 관한 비교 연구)

  • Choi, Yu-Sung;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.129-146
    • /
    • 2008
  • The aim of this study was to compare and analyze wear resistance of acrylic resin tooth in denture opposing to different types of restoration materials. Also, it aimed to compare and analyze the hardness of three various types of resin artificial teeth when using five different types of denture detergents. In this study three types of artificial teeth were used. As ordinary acrylic resin tooth $Trubyte^{(R)}Biotone^{(R)}$ (Dentsply, U.S.A.) was used, and as high hardness resin tooth Endura $Posterio^{(R)}$ (Shofu, Japan) and Physio $Duracross^{(R)}$ (Nissin, Japan) were used. To compare wear resistance, gold alloy, dental porcelain, and composite resin were used as opposing restorations. In addition, with three types of resin tooth stated above, five types of denture detergents, which are $Yuhanrox^{(R)}$ (Yuhanclorox, Korea), $Polident^{(R)}$ (Yuhan Co., Korea), $Cidex^{(R)}OPA$ (Johnson & Johnson Medical Co., Korea), $Hexamedin^{(R)}$ (Bukwang Pharm Co., Korea) and Daihan sterile $water^{(R)}$ (Daihan Pharm Co., Korea) were used to compare and analyze the effects denture detergents have on the surface hardness. The results of this study were as follow : 1. When composite resin and dental porcelain were used as the opposing restorations, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in ascending order showed decrease of cusp height with significant difference (p<0.05). 2. When gold alloy was used as opposing restoration, there was decrease in the cusp height in order of $Trubyte^{(R)}Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ and $Trubyte^{(R)}$ $Biotone^{(R)}$ especially showed significant decrease in high cusp height as compared to two other types of artificial tooth (p<0.05). 3. When composite resin, gold alloy and dental porcelain were used as opposing restorations, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in order decreased greatly in weight and these three materials showed significant difference (p<0.05). 4. Comparing the experiment values, decrease in strength had significant difference in all resin artificial teeth before and after the denture detergents were used (p<0.05). 5. When resin artificial teeth were subsided in $Yuhanrox^{(R)}$, $Cidex^{(R)}OPA$, and $Hexamedin^{(R)}$, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in order showed decrease in hardness, and $Trubyte^{(R)}$ $Biotone^{(R)}$ especially showed significant high decrease hardness as to other two types of artificial teeth (p<0.05). Therefore, Physio $Duracross^{(R)}$ seems to have superior wear resistance, and together with Endura $Posterio^{(R)}$, it presents excellent hardness as compared to $Trubyte^{(R)}$ $Biotone^{(R)}$. However, since this study is fragmentary, it should be given careful consideration and more study need to be done before making a definitive conclusion.

Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique (다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구)

  • Kim, Dong-Wook;Choi, Yu-Sung;Jo, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.343-358
    • /
    • 2011
  • As implant treatment has become popular, lots of different shapes and materials of the implant upper component have been supplied. And there are also diverse reports about failures including loosening of the abutment screw which is one of the most common reason. Purpose : The purpose of this study is to find out how different screw tightening orders and methods influence on screw loosening according to the different connection systems. The upper component was fabricated by casting method. After fabricating master models that are precisely attached to the upper component, 5 experimental models each for the external connection system and internal connection system were fabricated using splinting impression technique. First, to find out the influence of the screw tightening order, screws were tightened in 3 orders; 1-2-3-4, 2-3-1-4, 2-4-3-1. After tightening, removal torque values (RTV) of each group was measured. And also to find out the influence of screw tightening method, a model with 2-3-1-4 screw tightening order was tightened with 30 Ncm at one time(1-step method) and the RTV was compared with the same order group (2-3-1-4) in the 2 step method. In the external connection system, RTV appeared significantly lower in group 2-3-1-4 than group 2-4-3-1 (p<0.05). And also in the internal connection system, the RTV of group 2-3-1-4 appeared significantly lower than that of group 2-4-3-1 and 1-2-3-4 (p<0.05). When comparing the tightening number of the screw without considering the screw tightening order, the first tightened screw appeared significantly higher RTV than the second one in the external connection system (p<0.05), however there was no significant difference from the first tightened screw to the last tightened screw in the internal connection system. And there was no statistically significant difference between the two screw tightening methods in both internal and external connection system. In the comparison of external and internal connection system, each RTV appeared 16.27 Ncm and 14.25 Ncm and appeared as a statistically significant difference (p<0.05). There was a significant difference in RTV measured according to the screw tightening order. The lowest RTV appeared in the groups started tightening from the middle. There was also a significant difference in RTV between the two connection system groups. A further study is needed to find out the influence factors in RTV and also a study is required related to the load condition.

Clinical Assessment and Cephalometric Characteristics in Patients with Condylar Resorption (하악과두흡수 환자의 임상적 평가 및 악안면 골격형태에 대한 연구)

  • Koo, Seon-Ju;Kim, Kyun-Yo;Hur, Yun-Kyung;Chae, Jong-Moon;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.91-102
    • /
    • 2009
  • Condylar resorption, or condylysis can be defined as progressive alteration of condylar shape and decrease in mass. Condylar resorption is a poorly understood progressive disease that affects the TMJ and that can result in malocclusion, facial disfigurement, TMJ dysfunction, and pain. The aim of this study was to investigate clinical assessment and cephalometric characteristics in 224 patients with condylar resorption, who visited in the Department of Oral Medicine Kyungpook National University Hospital at 2006, by use of panorama, transcranial view and lateral cephalometric radiograph. The results were as follows; 1. Clinical assessment 1) Total number of patients who visited with chief complaints of TMD were 2419 and 224 (9.3%) among them revealed the condylar resorption, Among patients group with condylar resorption, female was 183 and male was 41, females were predominant. 2) Patient's age ranged from 12 to 70 and mean age was 30.6 years old with a strong predominance for 10s and 20s. Distribution of a showed as follows; 10s was 26.3%, 20s was 34,8%, 30s was 13.8%, 40s was 11.2%, 50s was 7.1%, 60s was 6.3% and 70s was 0.4%. 3) Most of the patients had parafunctional habit. 4) The case of showing the pain in condylar resorption was 145, the case of not showing the pain was 79. 5) Treatment duration of the patients was relatively short. 2. Cephalometric Characteristics 1) ANB which means the retruding of the mandible increased significantly than normal group. The ANB of female was lager than male group as the means of ANB were 5.05 in female and 3.57 in male, 2) SN-GoMe and FMA increased in resorption patients, but FH-PP did not show any significant difference. The FMA of female was lager than male group as the means were 31.69 in female and 30.44 in male. 3) Total posterior facial height was significantly smaller and total anterior facial height showed no significant increase as compared with those of the normal group. Condylar resorption was predominant in young female which was caused by more vertical facial pattern in female than male and increase of parafunctional habit in young age. It was thought that the patients who have a risk factor increasing the compressive stress at condyle caused by obliquely inclined masseter and medial pterygoid show high prevalence of condylar resorption.