• Title/Summary/Keyword: 교합면형태

Search Result 118, Processing Time 0.028 seconds

A ROENTGENOCEPHALOMETRIC STUDY ON THE DEPTH OF THE ANTEGONIAL NOTCH AND THE CRANIOFACIAL MORPHOLOGY IN CLASS III MALOCCLUSION (제3급 부정교합자의 악각전절흔 심도와 두안면골격 형태에 관한 두부방사선 계측학적 연구)

  • Kim, Hyung-Soo;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.19 no.1 s.27
    • /
    • pp.123-135
    • /
    • 1989
  • This study was undertaken to investigate the relationship between the depth of antegonial notch and the craniofacial morphology, and to predict the mandibular growth direction & potential in class III malocclusion. The computerized analyses were carried out on longitudinal lateral cephalometric radiographs of 50 children with class III malocclusion, divided into two groups ; 30 deep notch subjects (more than 2.6mm) and 20 shallow notch subjects (less than 1.5mm). The conclusions were as follows: 1. The mandibular growth direction in deep notch group was more vertically directed than in shallow notch group. 2. Deep notch group had shorter anterior & posterior cranial base than shallow notch group. 3. There was not significant difference between deep & shallow notch groups in the amount of mandibular growth during treatment period. 4. Notch depth increased in both deep & shallow notch groups during treatment period.

  • PDF

Convergence analysis of cusp variation symmetry of the mandibular second premolars using 3-dimensional virtual models - Focusing on college students in Jeollabuk-do (3차원 가상모형을 이용한 하악 제2소구치 교두 변이 대칭성에 대한 융복합적 분석 - 전북지역 일부 대학생을 중심으로)

  • Nam, Shin-Eun
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.317-323
    • /
    • 2022
  • This study aimed to qualitative analyze the cusp variation pattern of the mandibular second premolars using a three-dimensional virtual models, and to analyze the left-right bilateral symmetry with a quantitative analysis of the tooth surface area according to the cusp variation. 127 virtual mandibular second premolars were prepared and individual absolute/relative cusp area, total crown area and groove form were analyzed using RapidForm2004(INUS technology INC, Seoul, Korea). Independent t-test, Kruskal-Wallis test and chi-square were performed. As a result, the groove form showed high bilateral symmetry between the left and right sides. Based on the left side of groove form, the bilateral symmetry was 100.0% for the U pattern, and 73.7% for the H patterned, and 78.9% for the Y pattern(p<.001). The finding could be as a meaningful reference for manufacturing CAD/CAM dental prostheses, and it is expected that further studies will be conducted on more samples including the mandibular second premolar immediately after eruption.

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

Cephalometric difference according to the differential treatment methods in Class III malocclusion; (제 III급 부정교합 환자들의 각 치료법에 따른 측모두부방사선사진 계측치의 비교)

  • Baik, Hyoung Seon
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.197-208
    • /
    • 1997
  • Class III malocclusion patients can be approached with many different types of treatment methods, and thus, each patient's problems must be accurately evaluated to allow selection of the best possible treatment method. Cephalometric analysis is an essential part of diagnosis and treatment planning of orthodontic patients, and it would certainly be helpful if reliable cephalometric guidelines could be set. The author divided 482 Class III malocclusion patients(253 males and 229 females) into fourgroups according to different types of treatment methods they have received to correct imbalance between upper and lower jaws: 1) orthopedic appliance (face mask & RPE), 2) camouflage treatment with fixed appliance, 3) surgical-orthodontic treatment, 4) cross-bite correction with removable plates/ functional appliance. Cephalometric values at the time of first clinical examination were compare among the four groups. Cephalometric analysis indicates the following results: 1)the amounts of antero-posterior and vertical skeletal discrepancies and dental compensation were greatest in surgery group 2) SNB, Wits, distance from Nasion Perpendicular Plane to point a facial angle, facial convexity, and APDI were greater in orthopedic appliance group than fixed appliance(camouflage) group, but there was no statistical difference 3) removable plates/ functional appliance group showed least amounts of skeletal discrepancies and dental compensation with statistical significance.

  • PDF

A STUDY ON CEPHALOMETRIC EVALUATION OF MIXED DENTITION CHILDREN WITH NORMAL OCCLUSION (Ricketts 분석법에 의한 혼합치열기 정상교합 아동의 두부방사선계측학적 평가에 대한 연구)

  • Lee, Sang-Min;Jung, Tae-Ryun;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.248-261
    • /
    • 1999
  • In order to define a current set of Korean children norm with mixed dentition, following study was done. The subjects were 102 healthy dentition contestants(48boys, 54girls). Standardized lateral head roentgenograms were taken, and Ricketts analysis was done. Results were as follows: 1. Length of anterior cranial base, posterior facial height, corpus length were longer in male than in female(p<0.05), and Porion was located posteriorly in male than in female(p<0.01). 2. Through facial depth, Pogonion of male was more forwardly positioned(p<0.05), mandible was significantly steeper in female, and maxillary anterior teeth were significantly tipped forward in male(p<0.05). 3. Variables such as length of anterior cranial base, upper molar position(p<0.01) and corpus length(p<0.05) were significantly changed by age. 4. Maxillary height, facial depth, mandibular plane angle, convexity were changed by age, but not significantly(p>0.05).

  • PDF

Clinical study on the comparison of gold and zirconia wear in an implant-supported fixed prosthesis (임플란트 지지 고정성 보철물에서 금과 지르코니아의 마모 비교에 대한 임상 연구)

  • Kim, Jee-Hwan;Yang, Seung-Won;Oh, NamSik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.252-259
    • /
    • 2017
  • Purpose: The purpose of this study was to compare and analyze the wear of a prosthesis for 6 months after restoration with implant-supported fixed dental prosthesis made of either zirconia or gold. Materials and Methods: This study was conducted on patients requiring implant-supported fixed dental prostheses on first or second molar from January, 2015 to January, 2016. A total of 47 prostheses and antagonists were examined. Occlusal surface was recorded by impression of each prosthesis and antagonist 1 week and 6 months after prosthesis delivery. The digital files were created by impression scan. Occlusal shapes of 1 week and 6 months were compared and wear of prostheses and antagonists was analyzed. The Mann-Whitney test was used to analyzed the result data underwent normality test using SPSS (Version 23.0, IBM Corporation) Results: Mann-Whitney test revealed that there was no statistically significant difference in the median amount of mean vertical wear for 6 months in zirconia ($50.84{\mu}m$) and gold ($42.84{\mu}m$) prostheses (P > 0.05). When the opposing teeth were natural, the median amount of mean vertical wear of zirconia and gold prostheses was $47.72{\mu}m$ and $41.97{\mu}m$, respectively, and the median amount of mean vertical wear of enamel was $47.26{\mu}m$ and $44.59{\mu}m$, respectively. Statistical analysis showed no significant difference (P > 0.05). Conclusion: Despite the short study period and the small number of experimental groups, zirconia and gold showed no significant difference in wear during the first 6 months. Opposing natural enamel also showed no significant difference in the wear.

Comparison of arch form between Koreans and Egyptians (한국인과 이집트인의 치열궁 형태 비교)

  • Jang, Kab-Soo;Suk, Kyung-Eun;Bayome, Mohamed;Kim, Yoon-Ji;Kim, Seong-Hun;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.334-341
    • /
    • 2010
  • Objective: The purpose of this study was to evaluate morphologic differences in the mandibular arch between Egyptian and Korean subjects. Methods: The Egyptian sample consisted of 94 mandibular casts (35 Class I, 32 Class II and 27 Class III). The Korean sample consisted of 462 mandibular casts (114 Class I, 119 Class II, and 135 Class III). The most facial portion of 13 proximal contact areas was digitized from photocopied images of the mandibular dental arches. Clinical bracket points were calculated for each tooth. The subjects were grouped according to arch form to compare the frequency distribution of the 3 arch forms between the ethnic groups in each Angle classification. Results: Egyptians had significantly narrower intermolar and intercanine widths ($p$ < 0.001), and shallower intermolar and intercanine depths ($p$ < 0.001) than Koreans. There was an even frequency distribution of the 3 arch forms within the Egyptian group ($p$ = 0.46). However, in the Korean group, the most frequent arch form was the square arch form (46.7%), while the frequency of the tapered arch form was significantly lower (18.8%). Conclusions: These results might provide helpful information in evaluating morphologic differences between ethnic groups in selection of preformed superelastic archwires.

Effects of occlusal load on the stress distribution of four cavity configurations of noncarious cervical lesions: A three-dimensional finite element analysis study (네 가지 형태의 비우식성 치경부 병소의 3차원 유한요소법적 응력분석)

  • Jeon, Sang-Je;Park, Jeong-Kil;Kim, Hyeon-Cheol;Woo, Sung-Gwan;Kim, Kwang-Hoon;Son, Kwon;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.359-370
    • /
    • 2006
  • The objective of this study was to investigate the effect of excessive occlusal loading on stress distribution on four type of cervical lesion, using a three dimensional finite element analysis (3D FEA). The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. Four different lesion configurations representative of the various types observed clinically for teeth were studied. A static point load of 500N was applied to the buccal and lingual cusp (Load A and B). The principal stresses in lesion apex, and vertical sectioned margin of cervical wall were analyzed. The results were as follows 1. The patterns of stress distribution were similar but the magnitude was different in four types of lesion 2. The peak stress was observed at mesial corner and also stresses concentrated at lesion apex. 3. The compressive stress under load A and the tensile stress under load B were dominant stress. 4. Under the load, lesion can be increased and harmful to tooth structure unless restored.

Finite element analysis on the connection types of abutment and fixture (수종의 내부연결형 임플란트에서 연결부의 형태에 따른 응력분포의 유한요소 분석)

  • Jung, Byeong-Hyeon;Lee, Gyeong-Je;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.119-127
    • /
    • 2012
  • Purpose: This study was performed to compare the stress distribution pattern of abutment-fixture connection area using 3-dimensional finite element model analysis when 5 different implant systems which have internal connection. Materials and methods: For the analysis, a finite element model of implant was designed to locate at first molar area. Stress distribution was observed when vertical load of 200 N was applied at several points on the occlusal surfaces of the implants, including center, points 1.5 mm, 3.0 mm away from center and oblique load of 200 N was applied $30^{\circ}$ inclined to the implant axis. The finite element model was analyzed by using of 3G. Author (PlassoTech, California, USA). Results: The DAS tech implant (internal step with no taper) showed more favorable stress distribution than other internally connected implants. AS compare to the situations when the loading was applied within the boundary of implants and an oblique loading was applied, it showed higher equivalent stress and equivalent elastic strain when the loading was applied beyond the boundary of implants. Regardless of loading condition, the abutments showed higher equivalent stress and equivalent elastic strain than the fixtures. Conclusion: When the occlusal contact is afforded, the distribution of stress varies depending on the design of connection area and the location of loading. More favorable stress distribution is expected when the contact load was applied within the diameter of fixtures and the DAS tech implant (internal step with no tapering) has more benefits than the other design of internally connected implants.

Finite Element Stress Analysis of Bone Tissue According to the Implant Connection Type (2종의 임플란트 내부결합구조체에 따른 치조골상 유한요소응력 분석)

  • Byun, Ook;Jung, Da-Un;Han, In-Hae;Kim, Seong-Ryang;Lee, Chang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.259-271
    • /
    • 2013
  • The purpose of this study was to make the stress distribution produced by simulated different load under two types of internal connection implant system (stepped and tapered type) by means of 3D finite element analysis, The finite element model was designed with the parallel placement of the one fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st molar. Two models were loaded with 200 N magnitude in the vertical direction on the central position of the crown, the 1.5 mm and 3 mm buccal offset point from the central position of the fixture. The oblique load was applied at the angle of $30^{\circ}$ on the crown surface. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual dimension. The results were as follows; 1. The loading conditions of two internal connection implant systems (stepped and tapered type) were the main factor affecting the equivalent bone strain, followed by the type of internal connections. 2. The stepped model had more mechanical stability with the reduced max. stress compared to $11^{\circ}$ tapered models under the distributed oblique loading. 3. The more the contact of implant-abutment interface to the inner wall of implant fixture, the less stress concentration was reduced.