• Title/Summary/Keyword: 교통용량

Search Result 380, Processing Time 0.03 seconds

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

A Study on the Evaluation of Economic Benefit for Railway Transshipment System with Non-Powered Turntable (무동력 회전장치를 이용한 철도환적시스템의 경제성 평가에 관한 연구)

  • Kim, Kwanghee;Kim, Hyundeok
    • Journal of Korea Port Economic Association
    • /
    • v.29 no.4
    • /
    • pp.1-25
    • /
    • 2013
  • The purpose of this paper is to estimate economic benefits for the investment of railway transshipment system with non-powered turntable. The freight transport by railway can have decided advantages over trucks in terms of energy efficiency, emissions and cost for certain freight movements, just as transportation in the metropolitan region can have great advantages over driving truck. But the freight transport by truck should gain significant mobility benefits from a freight railway system. Thus, the railway transshipment system with non-powered turntable which is coupled railway transport advantages with load transport advantages has been developed and used in the european countries. This research has conducted the empirical analysis, by calculating the investment of railway transshipment system with non-powered turntable. The key factor for the economic benefits for the non-powered turntable is the utilizing throughputs. This demand is influenced by the throughput in the railway transshipment system. The main results of this paper are as follows: railway transshipment system with non-powered turntable does not have economic benefit for investment. We recommend that the plan for investment has to be considered the modification.

A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels (도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구)

  • Yoo, Yong-Ho;Yoo, Ji-Oh;Kim, Hyo Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.553-560
    • /
    • 2014
  • The road tunnel install a vent for the purpose of ventilation and smoke control. Ventilation equipment capacity(number of jet fans) depends on from the condition that of the pressure and ventilation resistance. Pressure and the resistance under operating vehicle have affected on the drag coefficient. The drag coefficient of the tunnel have affected by the blockage effect and slipstream effects. However, when calculating the ventilation fan, are not properly consider taking into account such effects. Therefore, ventilation force may have been slightly overestimated. This paper describes the drag coefficient through a numerical analysis to calculate the equivalent resistance area that reflects the vehicle distance, and examined the equivalent resistance area. The ventilation coefficient corresponding to the result heavy vehicle mixing ratio of the present study was not clear. Equivalent resistance area had reduced by about 86% compared to the road design handbook current standards. Also it had analyzed and reduced to 62.2% compared to Korea Highway Corporation ventilation design criteria ratio, which is the old standard.

Friction loss of multi-purpose stormwater tunnel simulated by Flow 3D (Flow 3D를 이용한 다목적 수로 터널의 마찰 손실 산정)

  • Lee, Du Han;Kim, Jung Hwan;Chung, Gunhui
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.14-21
    • /
    • 2017
  • The extreme floods recently are have been attributed global warming, The development of a canal tunnel to prevent floods by making a bypass or undercurrent to flood discharge in a major flooding area is required because urban flooding in heavy rainfall occurs frequently, increasing the impermeability according to lack of capacity in sewage to urbanization by the existing urban basin. In this study, a numerical simulation was performed to support design standards for a multi-purpose waterway tunnel combined road tunnel of canal tunnel. The numerical simulation showed that the size of the friction loss occurring in the tunnel section of the same channel occurred more than the theoretically calculated frictional loss derived from the numerical simulations. This is probably due to the additional frictional loss caused by the change in the flow structure due to the geometry of the pipe when the shape of the channel is non-circular. The increase in friction loss was more pronounced in the laminar flow than in the turbulent flow. Depending on the shape of the conduit, the friction loss should be adjusted for accurate flow calculations. This result can provide the basin information about the design of flood by a pass conduit.

Cause and Countermeasure of Inundation Damage in Underground Space (우리나라 지하공간 내수침수피해 원인 및 대책)

  • Cho, Jae-Woong;Choi, Woo-Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.420-420
    • /
    • 2011
  • 도시지역의 내수침수피해는 거의 매년 발생하고 있으며, 반지하와 같은 거주공간이 매우 취약한 상태이다. 특히 최근에는 지하철, 지하상가 등이 대규모 개발되고 복합네트워크화 되어 지하공간의 침수대책과 대피방안 마련이 시급한 상황이다. 일본의 경우 2000년 토카이 호우피해 후 통합유출해석 모형을 개발하였으며, 1999년 및 2003년 후쿠오카 침수피해 발생 후 특정도시하천침수피해대책법을 제정, 1999 후쿠오카, 2004년 하마마츠, 2008년 카누마 피해 후 일본 방재연구소에서는 실시간 1차원 지표범람모형과 모니터링을 통한 실시간 내수침수지도를 개발하였다. 특히 지하공간에 대해서는 "지하공간에 유입하는 범람수가 계단상 보행자게에 주는 위험성에 관한 연구" 등 실험을 바탕으로 각종 지하공간 침수대책 매뉴얼 및 지하시설의 침수시 피난확보계획 지침, 지하공간 침수대책 가이드라인 등 인명피해를 줄이고자하는 노력이 계속되어 오고 있다. 우리나라는 2006년 경기도 고양시 3호선 정발산역이 침수되었으며, 2010년 서울시 지하철 2호선 사당역 및 4호선이 침수되는 등의 지하철 침수피해와 2010년 서울시 광화문 지하상가, 인천시 부평구 우림라이온스 벨리, 우남플라자, 계양구 농협하나로마트, 서원아파트 등의 지하상가와 지하다층의 침수피해가 발생하였다. 특히 2006년 3호선 정발산역 침수는 17시간이나 지하철이 불통되었고 이로 인하여 심각한 교통 체증이 유발 되었다. 본 연구에서는 2010년 집중호우로 인한 서울, 인천지역의 지하공간 침수피해를 중심으로 최근 10년간 지하공간 침수피해사례로부터 대표적인 침수피해 원인 및 특성을 정리하였으며, 그 결과 지하공간 침수의 주요원인은 지상공간의 침수류가 지하공간으로 유입하고, 지하공간의 배수설비 용량부족, 지하공간으로의 유입을 방지하기위한 방지턱, 차수판, 침수시 비상전원 공급, 침수시 지하공간 대피 매뉴얼의 부재 등 다양한 원인이 있는 것으로 나타났다. 특히, 소방방재청에서 고시한 '지하공간 침수방지를 위한 수방기준'에 지하공간 침수 방지를 위한 각종 시설의 설치 및 대피 경로지정 등에 대한 기준이 마련되어 있으나, 지하공간 중 유동인구가 가장 많은 지하철역에서 조차 침수에 대한 행동매뉴얼이나 대피에 대한 가이드라인이 마련되지 않은 것으로 나타났다. 따라서, 지하공간 침수를 방지하기 위하여 센서를 이용한 자동 차수판과 경보기 설치, 지하공간의 사람들이 안전한 대피로를 찾을 수 있도록 지상공간 및 지하공간 출입구를 모니터링 할 수 있는 CCTV의 설치, Dry Area를 두어 비상대피 할 수 있는 공간의 마련 등 시설적인 부분에 대하여 '지하공간 침수방지를 위한 수방기준'을 더욱 강화할 필요가 있으며, 지상공간의 침수 상황을 고려한 지하공간의 대피매뉴얼 또는 가이드라인 등의 수립이 필요하다. 또한 이와 더불어 재산 및 인명피해를 더욱 효율적으로 줄일 수 있도록 실시간 예 경보를 위한 침수해석 모형의 개발이 시급하다.

  • PDF

Three-Car following model parameter estimation and vehicle tinting impact analysis using time-space GPS data (시공간 GPS자료를 활용한 연속차량 3대의 차량추종모형 파라메터 추정과 차량틴팅의 영향분석)

  • Kim, Hye-Won;Lee, Chung-Won
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.6
    • /
    • pp.15-23
    • /
    • 2011
  • Driving directly in front of the driver of a vehicle driving in front of the vehicle and it is commonly known is affected. Responding to the car in front of the driver and the vehicle in front, and these follow the model is known as Three-Car-Following Model. Platoon vehicles to follow behind the driver's visibility is affected by the a tinted vehicle, and Parameters of the model is estimated to be affected also. In this study, in Three-Car-Followng Model parameters were estimated. and the parameter values differ about whether and how analysis was performed by the level of Visible Light Transmission Percentage. RTK GPS receiving data through field experiment analyzed based on sensitivity of three car by Visible Light Transmission Percentage and ${\gamma}$. And With statistical verification of driving directly in front of the driver in front of the vehicle and that the moving vehicle is influenced also confirmed. Also Visible Light Transmission Percentage is lowered, the vehicle in front of the driver's behavior showed sensitive reactions. In the further need to research for influence analysis of traffic flow capacity by the level of VLT.

Motivation of the Satellite DMB Use and Genre Consumption (위성 DMB 이용 동기와 장르 소비: 장르 선호도, 레퍼토리, 소비유사성을 중심으로)

  • Chon, Bum-Soo;Kim, Jung-Kee
    • Korean journal of communication and information
    • /
    • v.36
    • /
    • pp.374-398
    • /
    • 2006
  • This paper attempts to identify motivations of the satellite DMB use and to examine the relationship between user motivations and structure of genre consumption. Firstly, this paper identified motivational dimensions for satellite DMB usage. The results of the factor analysis revealed three dimensions: information-seeking, entertainment-oriented and social communication. It accounts for 69.9% of the variances found within this data. Secondly, the results of the regression analyses suggested that both information seeking and entertainment-oriented motivations were closely related to genre preferences of satellite DMB contents. In addition, these two motivations predicted genre repertoires and similarity in genre consumption. In conclusion, motivations of the satellite DMB use were the best predictors for explaining the structure of genre consumption.

  • PDF

Development of optimal cross-section design methods for bored utility tunnels: case study of overseas typical cross-sections and design criteria (터널식 공동구 최적단면 설계기술 개발: 해외 표준단면 사례 및 설계기준 분석)

  • Park, Kwang-Joon;Yun, Kyoung-Yeol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1073-1090
    • /
    • 2018
  • Since the domestic utility tunnels were built mainly in the development project of the new city, they are all in the form of cut-and-cover box tunnel. But, in the case of overseas construction of utility tunnels for existing urban areas, the bored tunnel types are mainly adopted. It is reasonable to install bored tunnels in a downtown area because it is difficult to block the roads or install bypass roads due to heavy traffic and civil complaints. In order to activate the utility tunnels in bored type, it is necessary to secure optimized cross-sectional design technology considering the optimal supplying capacity and mutual influencing factors (Thermal Interference, electrolytic corrosion, efficiency of the maintenance, etc.) of utilities (power cables, telecommunication cables, water pipes, etc.). The optimal cross-section design method for bored utility tunnels is ultimately to derive the optimal arrangement technique for the utilities. In order to develop the design methods, firstly, the cases of tunnel cross-section (Shield TBM, Conventional Tunneling) in overseas shall be investigated to analyze the characteristics of the installation of utilities in the section and installation of auxiliary facilities, It is necessary to sort out and analyze the criteria related to the inner cross-section design (arrangement) presented in the standards and guidelines.

Method for increasing rail operation capacity of capital high speed rail with expanding the high speed railway service (고속철도 서비스 확대를 위한 수도권 고속철도 확충 방안 고찰)

  • Roh, Beung-Guk;Kim, Young-Bea;Shin, Dong-Won
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1254-1268
    • /
    • 2009
  • In 1998, because of the economic crisis called IMF Crisis in Korea, Kyungbu high speed railway project could run by modifying the original plan to open it as a 1st phase only by utilizing the existing railway lines from Seoul to Siheung and the other one from Daegu to Pusan. The modified plan includes that the line from Daegu to Pusan will be constructed as a second phase in next time. Starting railway operation with the changed plan, the combined application operation of high speed rail, passenger rail and freight rail was caused partly from Seoul to Siheung to run into capital area. As a result, the opinion for additional railway line construction is insisted continuously because the operation volume of passenger rail was forced to be reduced, the service quality of it was decreased and it became difficult to add new high speed services. Moreover, with regard to Honam high speed rail, the new construction plan of station in Kangnam metro area as a basement station for starting from Suseo was changed to the plan of turning out at Osong because of the economic effectiveness and this kept resident people in Kangnam metro area and southern Kyungki area unable to get the opportunity of high speed rail service benefit. After beginning of Kyungbu high speed railway operation, national transportation system developments are focused on high speed rail, and when the second phase construction of Kyungbu high speed rail, beginning operation of Kyungjeon line, Jeolla line double track construction, Honam high speed rail in 2014, is completed, the demand for high speed rail will be increased and it is unavoidable to make Kwangmyung station as a basement station and to reduce the number of passenger rail operation. At this moment, it is valuable to consider adding the railway line capacity in capital area to improve the transferring service for citizen who live in area without Kyungbu high speed rail station and to expand the service area from Kangbuk to Kangnam and southern Kyungki area. Accordingly, in this paper, the effective rail operation method, facility plan and the other issue to be reviewed for increasing capital high speed railway lines will be mentioned.

  • PDF

Utilizing the Idle Railway Sites: A Proposal for the Location of Solar Power Plants Using Cluster Analysis (철도 유휴부지 활용방안: 군집분석을 활용한 태양광발전 입지 제안)

  • Eunkyung Kang;Seonuk Yang;Jiyoon Kwon;Sung-Byung Yang
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.1
    • /
    • pp.79-105
    • /
    • 2023
  • Due to unprecedented extreme weather events such as global warming and climate change, many parts of the world suffer from severe pain, and economic losses are also snowballing. In order to address these problems, 'The Paris Agreement' was signed in 2016, and an intergovernmental consultative body was formed to keep the average temperature rise of the Earth below 1.5℃. Korea also declared 'Carbon Neutrality in 2050' to prevent climate catastrophe. In particular, it was found that the increase in temperature caused by greenhouse gas emissions hurts the environment and society as a whole, as well as the export-dependent economy of Korea. In addition, as the diversification of transportation types is accelerating, the change in means of choice is also increasing. As the development paradigm in the low-growth era changes to urban regeneration, interest in idle railway sites is rising due to reduced demand for routes, improvement of alignment, and relocation of urban railways. Meanwhile, it is possible to partially achieve the solar power generation goal of 'Renewable Energy 3020' by utilizing already developed but idle railway sites and take advantage of being free from environmental damage and resident acceptance issues surrounding the location; but the actual use and plan for these solar power facilities are still lacking. Therefore, in this study, using the big data provided by the Korea National Railway and the Renewable Energy Cloud Platform, we develop an algorithm to discover and analyze suitable idle sites where solar power generation facilities can be installed and identify potentially applicable areas considering conditions desired by users. By searching and deriving these idle but relevant sites, it is intended to devise a plan to save enormous costs for facilities or expansion in the early stages of development. This study uses various cluster analyses to develop an optimal algorithm that can derive solar power plant locations on idle railway sites and, as a result, suggests 202 'actively recommended areas.' These results would help decision-makers make rational decisions from the viewpoint of simultaneously considering the economy and the environment.