• Title/Summary/Keyword: 교차구멍

Search Result 26, Processing Time 0.024 seconds

Optimization of Drag-sail Storage Inspired from Blossom Method (개화형상을 모사한 가항력 돛 수납최적화)

  • Kim, Heekyung;Jung, Jinwon;Lee, Gunhee;Lee, Dongyun;Choi, Junwoo;Kim, Byungkyu
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.3
    • /
    • pp.16-21
    • /
    • 2017
  • In this paper, we propose a new folding method (the blossom method) to increase storage efficiency of drag-sail. To resolve the issue caused by increase in the thickness of the sail, we allowed margin space (offset) along the folding line and made holes at the intersection of offset lines to prevent distortion of film. In addition, to verify applicability of the blossom method, we fabricated quarter of the sail by using Mylar film and conducted a deployment experiment. If the blossom method is applied, storage ratio (storage volume: deployed area) is 1: 68.64, that is approximately 1.88 times more than the z-fold method of folding sailing.

Precise Measurement of the Steel Box Girder Using Industrial Photogrammetry Method (산업사진측량 기법에 의한 교랑 강박스거더 정밀측정)

  • Jung Sung Heuk;Lee Jae Kee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.1
    • /
    • pp.69-76
    • /
    • 2005
  • The purpose of this study was to establish the accuracy of the industrial photogrammetry system constructed with INCA2 metric camera and V-STARS system on steel box girder measurement under industrial measurement condition. The objective of the measurement was to determine the distances of plane to plane or plane to libs, precise positions of the bolt holes and angles of the plane to plane on the steel box girder using coded targets, tape targets, edge targets and target adapters. The measurement undertaken has shown that industrial photogrammetry method were a very accurate and more importantly were produced quickly to measure the steel box girder.

Ultrastructure of Degenerating Axon Terminals in the Basal Forebrain Nuclei of the Rat following Prefrontal Decortication (이마앞겉질을 제거시킨 흰쥐 앞뇌의 바닥핵무리에서 변성축삭종말의 미세구조연구)

  • Ahn, Byung-June;Ko, Jeong-Sik;Ahn, E-Tay
    • Applied Microscopy
    • /
    • v.35 no.3
    • /
    • pp.135-152
    • /
    • 2005
  • Prefrontal cortex is a psychological and metaphysical cortex, which deals with feeling, memory, planning, attention, personality, etc. And it also integrates above-mentioned events with motor control and locomotor activities. Prefrontal cortex works as a highest CNS center, since the above mentioned functions are very important for one's successful life, and further more they are upgraded every moments through memory and learning. Many of these highest functions are supposed to be generated via forebrain basal nuclei (caudate nucleus, fundus striati nucleus, accumbens septi nucleus, septal nucleus, etc.). In this experiment, prefrontal efferent terminals within basal forebrain nuclei were ultrastructurally studied. Spraque Dawley rats, weighing $250{\sim}300g$ each, were anesthetized and their heads were fixed on the stereotaxic apparatus (experimental model, David Kopf Co.). Rats were incised their scalp, perforated a 3mm-wide hole on the right side of skull at the 11mm anterior point from the frontal O point (Ref. 13, Fig. 1), suctioned out the prefrontal cortex including cortex of the frontal pole, with suction instrument. Two days following the operations, small tissue blocks of basal forebrain nuclei were punched out, fixed in 1% glutaraldehyde-1% paraformaldehyde solution followed by 2% osmium tetroxide solutions. Ultrathin sections were stained with 1% borax-toluidin blue solution, and the stained sections were obserbed with an electron microscope. Degenerating axon terminals were found within all the basal forbrain nuclei. Numbers of degenerated terminals were largest in the caudate nucleus, next in order, in the fundus striati nucleus, in the accumbens septi nucleus, and the least in the septal nucleus. Only axospinous terminals were degenerated within the caudate nucleus and the fundus striati nucleus, and they showed the characters of striatal motor control system. Axodendritic and axospinous terminals were degenerated within the accumbens septi nucleus and the lateral septal nucleus, and they showed the characters of visceral limbic system. Prefrontal role in integrating the limbic system with the striatal system, en route basal forebrain nuclei, was discussed.

A Suture Bridge Transosseous-Equivalent Technique for Bankart Lesions with Deficient Bony Stability - Technical Note - (골안정성 결손을 가진 Bankart 병변에 대한 경 골-유사 교량형 봉합술식 - 술기 보고 -)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Chang, Il-Woong;Chae, Sung-Bum
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.179-182
    • /
    • 2009
  • Purpose: Point fixation at the margin of the glenoid is a limitation of conventional arthroscopic stabilization using suture anchors, and does not afford sufficient footprint healing, especially in glenoid bone deficiency. So, we introduce an arthroscopic suture bridge transosseous-equivalent technique for bony Bankart lesions to avoid the technical disadvantage of point contact with anchor fixation and to improve mechanical stability through cross compression of the labrum. Surgical approach: The technique was adapted from the transosseous-equivalent rotator cuff repair technique using suture bridges, which improved the pressurized contact area and mean pressure between the tendon and footprint. After preparation of the glenoid bed by removal, reshaping, or mobilization of the bony lesion, two anchors (3.0 mm Biofastak, $Arthrex^{(R)}$, Naples, FL) were inserted into the superior and inferior portion of the bony Bankart lesion. Using a suture hook, medial mattress sutures were applied around the capsulolabral portion of the IGHL complex to obtain sufficient depth of glenoid coverage. A 3.5 mm pushloc anchor ($Arthrex^{(R)}$, Naples, FL) hole was made in the articular edge of the anterior glenoid rim. distal, suture bridge was applied, and proximal was inserted to mobilize the labrum in the proximal direction. This avoided the technical disadvantage of point contact with anchor fixation and decreased the level of gap formation through cross-compression of the labrum.

  • PDF

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF