• Title/Summary/Keyword: 교차교정

Search Result 36, Processing Time 0.132 seconds

A LIGHT AND ELECTRON MICROSCOPIC STUDY OF CHANCES IN INTERMAXILLARY SUTURE DURING THE RAPID MAXILLARY EXPANSION OF YOUNG ADULT DOGS (유성견 급속정중이개시 정중구개봉합부위의 조직학적 변화에 대한 연구)

  • Lee, Doo-Hee;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.153-162
    • /
    • 1996
  • Rapid maxillary expansion is widely used for the correction of anteroposterior discrepancies, constriction of the maxillary arch, etc. This experiment was undertaken to examine the serial changes in the osteogenesis as well as the collagen fiber bundles in the intermaxillary suture during the rapid maxillary expansion treatment. Four young female dogs aged 6 to 8 months old and not showing menarche yet were used for the experiment. The maxillary impression of dogs were taken, expansion device cast and Hyrax screw soldered at the midline in the 1st premolar area. RME device was delivered to the dogs and the activation of 0.25 mm per quarter-turn was done 2 times per day for 10 days until 5 mm separation was made. Separation of the maxilla was confirmed by X-ray. The animals were sacrificed on 0, 15, 30, 60 days from the finish of maxillary separation and preparations for light microscopy and surface electron microscopy were made. The sutures were cut into frontal serial sections for examination of the histological reactions. The following results were obtained and the conclusions made. 1. The edges of the two palatal plates bordering the midpalatal suture which at the beginning of the retention period were mainly composed of compact bone, underwent extensive resorption followed by new bone formation and gradually became spongy bone rich in bone marrow which in the 60 day retention animal became the compact bone with short intermaxillary suture space. During this transformation, newly formed trabecular bone tissues were added to the original margin. 2. Throughout the expansion period, the collagen fibers underwent successive changes such as stretching, loss of polarity, and finally fibrillogenesis. Towards the end of the expansion procedure, sharpey's fiber formation in newly formed bones were observed. 3. Bony spicules were found in the initial stage of retention on occlusal topographic X-rays, which later were confirmed to have ossified. 4. Judging from the histological changes occuring during the experimental expansion, excessive expansion will cause an excessive bleeding, and retard the remodeling of intermaxillary suture. According to the above results, the bone remodeling after rapid maxillary expansion was preceded by the migration of migratory cells into the intermaxillary suture area. The bone remodeling phenomena were on-going during the 2 months retention sample.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Clinical Analysis of Ectopic Kidney in Children (소아 이소성 신장의 임상적 고찰)

  • Yook Jin-Won;Kim Ji-Hong;Kim Myung-Joon;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.196-202
    • /
    • 1999
  • Purpose : When the mature kidney fails to reach its norml location in the renal fossa, the condition is known as ectopic kidney. Presenting symtoms can be various and it generally depend on the associated anomaly. Beside urologic anomalies such as hydronephrosis and vesicoureteral reflux, various anomalous vascular net work, skeletal anomaly or genital anomaly can be observed in this condition. Methods : Sixteen children with ectopic kidney was studied retrospectively to analyse initial presentation, accompanied anomaly and prognosis. Results : 56% of the children were accompanied with other urologic anomalies such as true incontinence and vesicoureteral reflux that required surgical treatment. 31% of children were either diagnosed incidentally during evaluation of other non-urologic disease or during follow-up evaluation of abnormal antenatal renal sonogram. Conclusion : Ectopic kidney can be often misdiagnosed as tumorous condition or as a surgical condition depend on the abnormal location of the kidney. Careful evaluation using abdominal sonogram, DMSA, VCUG and abdominal CT scan should be performed in order to search for associated anomalous condition and for proper management.

  • PDF

Elementary School Students' Amounts of Sugar, Sodium, and Fats Exposure through Intake of Processed Food (초등학생의 주요 가공식품으로부터 섭취하는 당, 나트륨, 지방류 등의 노출실태 조사 연구)

  • Kang, Moon-Hee;Yoon, Ki-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.1
    • /
    • pp.52-61
    • /
    • 2009
  • The purpose of this study was to investigate the extent of excessive sugar, sodium, cholesterol, and saturated fat consumptions by elementary school students through processed food's intake. A survey study was conducted with 384 fourth and sixth grade students and their mothers from two schools in Seoul and Gyeonggi province. The data were analyzed for the frequency analysis, chi-square test and Pearson correlation using the SPSS/Windows (ver. 15.0). Results showed that students consumed high amounts of sugars through processed milk and carbonated beverages, and yogurt. Additionally, they had high sodium and saturated fat levels in their diet through Ramen. There was significant correlation (p<0.01) between mothers' purchasing and students' intake of processed food. Overall, both students and mothers had some knowledge on the impact of sodium on human health. About 50 percent of the respondents did not have accurate information about cholesterol, saturated fat, and trans fat. More than 50 percent of students and mothers had no nutritional education on the risk of excessive intake of sugar, sodium, cholesterol, saturated fat, and trans fat. Top twenty percent of the students had 39.7 g of sugar, 940.1 mg of sodium, 17.8 mg of cholesterol, and 11.2 g of saturated fat through processed foods per day on the average. These results suggest that execution of nutritional education about processed food is needed for high risk group of elementary school students and their mothers. Moreover, government must enact the regulation and policy for the food industry to reduce the risky nutrients from children's favorite processed food.

A Study on Accuracy and Usefulness of In-vivo Dosimetry in Proton Therapy (양성자 치료에서 생체 내 선량측정 검출기(In-vivo dosimety)의 정확성과 유용성에 관한 연구)

  • Kim, Sunyoung;Choi, Jaehyock;Won, Huisu;Hong, Joowan;Cho, Jaehwan;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.171-180
    • /
    • 2014
  • In this study, the authors attempted to measure the skin dose by irradiating the actual dose on to the TLD(Thermo-Luminescence Dosimeter) and EBT3 Film used as the In-vivo dosimetry after planning the same treatment as the actual patient on a Phantom, because the erythema or dermatitis is frequently occurred on the patients' skin at the time of the proton therapy of medulloblastoma patient receiving the proton therapy. They intended to know whether there is the usefulness for the dosimetry of skin by the comparative analysis of the measured dose values with the treatment planned skin dose. The CT scan from the Brain to the Pelvis was done by placing a phantom on the CSI(Cranio-spinal irradiation) Set-up position of Medulloblastoma, and the treatment Isocenter point was aligned by using DIPS(Digital Image Positioning System) in the treatment room after planning a proton therapy. The treatment Isocenter point of 5 areas that the proton beam was entered into them, and Markers of 2 areas shown in the Phantom during CT scans, that is, in all 7 points, TLD and EBT3 Film pre-calibrated are alternatively attached, and the proton beam that the treatment was planned, was irradiated by 10 times, respectively. As a result of the comparative analysis of the average value calculated from the result values obtained by the repeated measurement of 10 times with the Skin Dose measured in the treatment planning system, the measured dose values of 6 points, except for one point that the accurate measurement was lacked due to the measurement position with a difficulty showed the distribution of the absolute dose value ${\pm}2%$ in both TLD and EBT Film. In conclusion, in this study, the clinical usefulness of the TLD and EBT3 Film for the Enterance skin dose measurement in the first proton therapy in Korea was confirmed.

Cytologic Screening for Cervical Cancer and Factors Related to Cervical Cancer (대구시(大邱市) 기혼(旣婚) 여성(女性)의 자궁경부암(子宮頸部癌) 유병률(有病率)과 그 관련요인(關聯要因))

  • Jeon, Yong-Jae;Lee, Chi-Young;Chun, Byung-Yeol;Kam, Sin;Yeh, Min-Hae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.3 s.35
    • /
    • pp.428-440
    • /
    • 1991
  • This study was conducted to estimate the prevalence rate of cervical cancer and to investigate its risk factors. 5,417 asymptomatic married women were screened from March, 1984 to December, 1990 in Taegu city. Of 5,417 examinees, 3,817 (70.46%) were normal, 1,542 (28.7%) showed inflammatory change, 51 (0.94%) were dysplasia and 7 (0.13%) were carcinoma in situ or invasive carcinomas. The prevalence of abnormal finding (dysplasia, carcinoma in situ or invasive carcinoma) was 1,070 per 100,000 population. The prevalence of dysplasia was 940 per 100,000 and that of carcinoma in situ or invasive carcinoma was 130 per 100,000. Age-adjusted prevalence rate for abnormal finding adjusted with standard population of Taegu city was estimated to be 850 per 100,000. The prevalence of cervical cancer was significantly increased with age (P<0.05). The prevalence of cervical cancer was significantly decreased with age at marriage and educational level (P<0.05). The history of induced abortion and the number of pregnancies were significantly associated with the prevalence of cervical cancer (p<0.05), whereas, the number of parity was not. Age at marriage was significantly associated with the prevalence of cervical cancer after stratification by age (p<0.05). However, the level of education, parity, induced abortion, number of pregnancies were not significant. Inflammation and human papiloma virus infection were associated with cervical cancer with odds ratio of 13.48 (95% confidence interval $7.80{\sim}23.40$) and 474.29 (95% confidence interval $196.80{\sim}1143.10$), respectively. In conclusion, for early detection of cervical cancer it should be recommended to perform mass cytological screening. In particular, regular and periodic cytologic screening, starting at age 25, for cervical cancer should be recommended for those women who have frequent cervical inflammation and for those women married before age of 20.

  • PDF