• Title/Summary/Keyword: 교차교정

Search Result 36, Processing Time 0.034 seconds

A Study on the Branch Composition of an Optimum Polarization Diversity by Considering XPD in Indoor Radio Environments (실내무선 환경에서 XPD를 고려한 최적편파 다이버시티의 브랜치 구성에 관한 연구)

  • 하덕호;이주현;윤영석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.302-311
    • /
    • 1999
  • In this paper, in order to suggest an optimal polarization diversity composition method in indoor radio wave propagation environments, the variation of the cross polarization discrimination(XPD) was theoretically analyzed by a computer simulation and compared to the actual measured data. From the results, it can be seen that the cross polarization discrimination of the case, a circularly polarized antenna was used at the transmitting end as well as the vertical and horizontal polarized antenna branches were used at receiving end (CV-CH), is lower than that of the case, horizontal polarized antenna at the transmitting end as well as the horizontal and vertical polarized antenna branches at the receiving end(HH-HV), and that of the case, vertical polarized antenna at the transmitting end as well as the vertical and horizontal polarized antenna branches at the receiving end(VV-VH). In this paper, to get more effective CV-CH polarization diversity composition, the amount of cross polarization discrimination values at the signals received by horizontal polarized antenna is compensated and the polarization diversity effect through the cumulative probability distribution is estimated. From the evaluation results, it was found that the polarization diversity effect was better at the compensated case than at the uncompensated case. On the other hand, it can be known that the polarization diversity effect is getting better as the cross polarization discrimination values are getting lower, and also be known that the effect can be improved if a transmitting antenna is composed of the ellipse polarized antenna by adjusting the axial ratio of the circularly polarized antenna and, a receiving antenna is made up of the vertical and horizontal polarized antenna branches.

  • PDF

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.

A method of Pseudo-stereoscopic image detection and correction (Pseudo-stereoscopic 영상 자동 판별 및 보정 방법)

  • Park, Young-Soo;Hur, Nam-Ho
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.07a
    • /
    • pp.244-247
    • /
    • 2010
  • 입체 영상의 왼쪽과 오른쪽이 서로 바뀐 'pseudo-stereoscopic' 영상에서는 올바른 입체감을 느끼기 어려운데, 이를 해결하기 위해서는 직접 눈으로 보고 'pseudo-stereoscopic' 영상 여부를 판단하여 두 영상을 바꿔줘야 하는 불편함이 있었다. 따라서 본 논문에서는 입체 영상 사이에 갖고 있는 특성을 이용하여, pseudo-stereoscopic 영상을 자동으로 확인하고, 이를 바꿔주는 방법을 제시하고자 한다. 이를 위해 입체 영상으로부터 카메라의 종류를 확인하여, 교차축 카메라의 경우는 교정화 과정을 수행한다. 그리고 한 쪽 영상에서 선택한 비교 영역과 다른 쪽 영상의 대응 영역 사이의 변이 값을 비교함으로써 pseudo-stereoscopic 영상을 판단하고, 올바르게 바꿔줌으로써 시청자가 올바른 입체감을 느낄 수 있도록 하였다.

  • PDF

The Study on the Use of a Cylindrical Ionization Chamber for the Calibration of a 6 MeV Electron Beam (6 MeV 전자 빔의 교정에 원통형 이온함의 사용에 관한 연구)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Choi, Jin-Ho;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • The standard dosimetry systems based on an absorbed dose to water recommend to use a planeparallel chamber for the calibration of such a low-megavoltage electron beam as a nominal energy of 6 MeV. For this energy ranges of an electron beam a cylindrical chamber should not be used for the routinely regular beam calibration, but the feasibility of the temporary use of a cylindrical chamber was studied to give temporary solutions for special situations users meet. The PTW30013 chambers and the electron beam quality of $R_{50}=2.25\;g/cm^2$ were selected for this study. 10 PTW30013 chambers, a cylindrical type of chamber, were calibrated in KFDA, the secondary standards dosimetry laboratories, and given the absorbed dose-to-water calibration factors, respectively. A "temporary" $k_{Q,Q_0}$ for each chamber were calculated using the absorbed dose determined by a cross-calibrated planeparallel chamber, with the result of an average 0.9352 for 10 chambers. This value for PTW30013 chamber was used to determine an absorbed dose to water at the reference depth. The absorbed doses determined by PTW30013 chambers were in an agreement within 2% with that by ROOS chamber. In a certain situation where a cylindrical chamber be used instead of a planeparellel chamber, the value of 0.9352 might be useful to determine an absorbed dose to water in the same beam quality of electron beam as this study.

  • PDF

Three dimensional structural analysis between dental arch and basal bone in normal occlusion (정상교합자의 치열궁과 기저골 형태에 대한 3차원적 연구)

  • Kim, Jee-Tae;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.224-236
    • /
    • 2011
  • Objective: The purpose of this study was to analyze the dental and basal arch forms in patients with normal occlusion using the computed tomography (CT) imaging method. Methods: CT images were taken from 27 normal occlusion subjects (male, 15; female, 12) and these images were reconstructed into three-dimensional models. A 3D-coordinate system was formed by setting the middle of the facial axis (FA) point of the maxillary central incisors as the origin. The morphology of the maxilla and mandibular dental and basal arches were analyzed by sectioning parallel to the maxillary occlusal plane. Results: There was no significant difference between A point and B point and between the maxillary 1st molars in both sides of the maxillary and mandibular basal bone. The dental arch was located more labially than the basal arch in the anterior portion. The bucco-lingual crossover of the dental arch and basal arch was formed at the molar region in the maxilla, and at the premolar region in the mandible. Conclusions: This study will help provide three-dimensional diagnostic information about the relationship between basal and dental arches in patients who have severe dental compensation and inappropriate jaw relationships.

Evaluation of the Ergonomic Method and Musculoskeletal Symptoms in Dental Hygienist (치과위생사의 근골격계질환 자각증상과 인간공학적 평가)

  • Oh, Na-Rae;Kim, Hae-Kyeong;Jeong, Mi-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.234-243
    • /
    • 2012
  • The purpose of this study was to estimate the prevalence of musculoskeletal symptoms and work-related factors of these symptoms in dental hygienists. The self-administered questionnaire was surveyed and collected from August 1-12 of 2011 targeting 210 dental hygienists Seoul, Gyeonggi, Daegu, Pohang. Except 5 people whose responses are not clear and who suffered accident, the analysis was made on 205 people. Data analysis was performed using the chi square test and multiple logistic regression analysis using the SPSS WIN(ver 18.0) program, RULA and, REBA. The overall Experience rate of musculoskeletal symptoms was 95.6% (196/205). The specific Experience rate of musculoskeletal symptoms for different regions of the body were as follows:The highest was shown 82.4% in Neck-shoulders(R), 78% in Neck, 69.8% in shoulders(R), 66.3%in Wrist(R). Therefore, Improvements of working environments in dental clinics are needed to prevent musculoskeletal disease development in dental hygienists.

SEMI-LONGITUDINAL STUDY ON GROWTH AND DEVELOPMENT OF CHILDREN AGED 6 TO 17 -Part III : GROWTH CHANGE OF CRANIOFACIAL HARD TISSUE (한국인 6-17세 아동의 성장과 발육에 관한 준종단적 연구 -제 3 세부 과제 : 두개 및 안면 경조직의 성장변화)

  • Hwang, Chung-Ju;Kil, Jea-Kyoung;Lim, Seon-A
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.469-485
    • /
    • 1996
  • Orthodontic patients are individuals that grow and develop ; therefore selection of the proper time for orthodontic treatment is considered to be one of most difficult and yet difficult factor. Since the development of cephalometric X-ray, amount and Pattern of craniofacial growth change with aging could be predicted and be came useful in the process of orthodontic treatment. The relationship between the mean values of cephalometric measurements and body height and weight was studied among the groups(boys and girls) of Korean children from the ages 6-years to 17-years. 409 boys and 437 girls with no abnormality in growth and development and no history of orthodontic treatment from the ages of 6 years to 17 years were chosen as subjects Cephaloment X-ray were taken for 3 years and hard tissue analysis based on Burstone's COGS, which was devided into measurements of 6 parts(Cranial base, Maxillar and Mandible, Dental measurements). The relationship between craniofacial growth and height & weight was studied. The following conclusions were obtained : 1. The maximum growth in the measurements of cranial base, N-Ar(FH), N-Ba(FH) corresponded with the age with the maximum increase in body height & weight in both boys and girls. 2. Genial angle gradually decreased with aging in both boys and girls. 3. N-ANS(L) showed greater amount of growth than ANS-Ne(L), and this had greater influence on facial profile. 4. N-A-$Pog^{\circ}$ decreased with aging, and mandibular growth exceeded maxillary growth in amount and rate. 5. Length of Y-axis Increased, but Y-axis to FH plane remained constant. This show that mandible grows at a constant angulation to cranial base. 6. As permanent teeth erupt, interincisal angle deceased.

  • PDF

Study on the Applicability of Semiconductor Compounds for Dose Measurement in Electron Beam Treatment (전자선 치료 분야의 선량 측정을 위한 반도체 화합물의 적용가능성 연구)

  • Yang, Seungwoo;Han, Moojae;Shin, Yohan;Jung, Jaehoon;Choi, Yunseon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • In this study, it was intended to replace the existing plane parallel ionization chamber, which requires cross-calibration in electron beam treatment. The semiconductor compounds HgI2 was fabricated as detector, and the characteristics of HgI2 detector for the 6, 9 and 12 MeV electron beam was analyzed in the linear accelerator. It was also intended to evaluate the possibility of substitution with existing detectors and their applicability as electron beam dosimetry and to use them as a basic study of the development of electronic beam dosimeter. As a result of reproducibility, RSD was 0.4246%, 0.5054%, and 0.8640% at 6, 9, and 12 MeV energy, respectively, indicating that the output signal was stable. As a result of the linearity, the R2 was 0.9999 at 6 MeV, 0.9996 at 9 MeV, and 0.9997 at 12 MeV showed that the output signal is proportional to HgI2 as the dose is increased. The HgI2 detector of this study is highly applicable to electron beam measurement, and it may be used as a basic research on electron beam detection.

Case of Acute Hemolytic Transfusion Reaction due to Anti-Fya Alloantibody in a Patient with Autoimmune Hemolytic Anemia (자가면역용혈환자에서 항-Fya 동종항체에 의한 급성용혈성수혈반응 1예)

  • Choi, Seung Jun;Nah, Hyunjin;Kim, Yundeok;Kim, Sinyoung;Kim, Hyun Ok
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.320-327
    • /
    • 2018
  • A 72-year-old man with general weakness visited the outpatient clinic of the hematology department. The patient had been treated under the diagnosis of autoimmune hemolytic anemia for 2 years. His hemoglobin level at the time of the visit was 6.3 g/dL, and a blood transfusion was requested to treat his anemia. The patient's blood type was A, RhD positive. Antibody screening and identification test showed agglutination in all reagent cells with a positive reaction to autologous red blood cells (RBCs). He had a prior transfusion history with three least incompatible RBCs. The patient returned home after receiving one unit of leukoreduced filtered RBC, which was the least incompatible blood in the crossmatching test. After approximately five hours, however, fever, chills, dyspnea, abdominal pain, and hematuria appeared and the patient returned to the emergency room next day after the transfusion. The $anti-Fy^a$ antibody, which was masked by the autoantibody, was identified after autoadsorption using polyethylene glycol. He was diagnosed with an acute hemolytic transfusion reaction due to $anti-Fy^a$ that had not been detected before the transfusion. In this setting, it is necessary to consider the identification of coexisting alloantibodies in patients with autoantibodies and to become more familiar with the method of autoantibody adsorption.

A Clinical Study on Bone Grafting of Alveolar Clefts (치조열 환자의 골이식에 대한 임상적 연구)

  • Ryu, Sun-Youl;So, Kwang-Sub
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.3
    • /
    • pp.256-262
    • /
    • 1998
  • The aim of this study was to evaluate treatment plan and treatment procedure such as bone graft material, timing of bone graft and orthodontic treatment in 31 alveolar cleft bone graft patients treated at the Department of Oral and Maxillofacial Surgery of Chonnam University Hospital from Jan. 1992 to Dec. 1996. Results obtained were as follows : In total 31 patients of alveolar bone grafts, males(64.5%) were more than females(35.5%). The patients' age ranged between 2 - 33 years of age. Secondary bone grafting was the highest incidence(58.1%) when procedures were undertaken in patients between 6 - 16 years of age. In distribution of cleft side, unilateral clefts(93.5%) were the major part with the left side was larger than the right side. The Missing teeth were found most in lateral incisor, the supernumary teeth were found most between lateral incisor and canine. The most common occlusion before operation was class III malocclusion and anterior cross-bite(65.1%), orthodontic treatment was performed similarly between before and after the bone graft. The most common combined operation with alveolar bone graft was secondary cheiloplasty. The complications were 6 cases of bone defect, a case of oronasal fistula, 3 cases of dehiscence. PMCB and DFDB were used bone graft materials. In marginal bone height after operation, PMCB grafts were higher than DFDB grafts and marginal bone level was increased in the PMCB group but not in the DFDB group.

  • PDF