• Title/Summary/Keyword: 교정주기

Search Result 150, Processing Time 0.028 seconds

Loss of Corrected Visual Acuity According to Different Meridional Visual Acuity in Astigmatic Eyes (난시안에서 주경선 간 시력차이와 교정시력의 손실)

  • Jo, Na Young;Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.77-81
    • /
    • 2016
  • Purpose: This study was performed to investigate the difference of meridional visual acuity and the loss of corrected visual acuity (VA) in order to emphasis the importance of astigmatic correction. Methods: 64 subjects (122 eyes) aged $22.75{\pm}2.36years$ participated in this study. After full correction of astigmatic refractive error, VA was measured in which the direction of the slit filter was matched with astigmatic axis and $90^{\circ}$ to the astigmatic axis. Results: 52 eyes showed no difference in VA between the two direction. However 70 eyes had difference VA between them. 14 out of 52 eyes and 24 out of 70 eyes had under 1.0 in monocular VA. The astigmatic degree was higher in the existence of VA difference between the two direction than non-existence. The difference is higher with under 1.0 monocular VA. Monocular VA is closely related to the focal line having better VA in the principal focal line. Glasses replacement period was analyzed as 6~12 months for the preservation of better VA. Conclusions: The final glasses prescription has to be given with full correction because continued under-correction for astigmatism causes meridional VA difference.

THE STUDY ON THE ORTHODONTIC PATIENTS WHO VISITED DEPARTMENT OF ORTHODONTICS, SEOUL NATIONAL UNIVERSITY HOSPITAL DURING LAST 10 YEARS(1985-1994) (최근 10년간 서울대학교병원 교정과에 내원한 부정교합 환자에 관한 고찰 (1985년 - 1994년))

  • Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.497-509
    • /
    • 1995
  • With socioeconomic development and change of esthetic recognition, the demand for orthodontic treatment and number of orthodontic patients has been increasing so rapidly. And frequency of malocclusion was changed. So this study was done in an attempt to provide an epidemiologic study so that we can accomodate their orthodontic needs adequately and to obtain the reliable quantitative information regarding the characteristics of orthodontic patients who visited Department of Orthodontics, Seoul National University Hospital from 1985 to 1994. Following results were obtained. 1. The total number of orthodontic patients of SNUDH during 1990-1994 increased in comparing with that of 1985-1989. And it showed that the number of annual patients was increasing trend. 2. The total number of female patients was 1.59 times as high as that of male. It showed that the annual percentage of female patients has been increasing and that of male patients has been decreasing. So demands for orthodontic treatment of malocclusion of female patients were higher than that of male patients. 3. Each total percentage of class I, class II div.1, class II div. 2 and class III was 35.98%, 14.00%, 1.74% and 48.28%. The annual percentage of class I group had been decreasing but it has increased at 1994. However that of Class III group had been increasing until 1991 but it has been decreasing. 4. Each percentage of less than 6 year-old group, D to 8 year-old group, 8 to 12 year-old group, 12 to 18 year-old group and more than 18 year-old group was 2.65%, 8.63%, 32.50%, 27.74% and 28.48%. Annual percentage of 12 to 18 year-old group ( middle & high school students group ) had been decreasing but it has been increasing. However 18 year-old group had been increasing but it has been decreasing. So entrance examination for college and university is an important factor to distribution of age group.

  • PDF

Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter (Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석)

  • Jang, Ji-Yong;Jeong, Moon-Taeg;Song, Jong-Nam;Ha, Jae-Jun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • In the surface contamination test using the end-window Geiger-Muller type counter, the wrap is used as a method for protecting the detector exposed to the outside in order to measure the beta-rays. We analyze the effect of this method on the measurement rate and the correction factor, and wanted to make it clear to radiation workers that excessive use of the wrap can affect the measured value of the beta-rays. The experimental method was to compare and analyze the change of the beta-rays measurement counting rate and the calibration factor according to the wrap thickness using the beta-rays with different energy of 3 KBq, 1.5 KBq and 0.3 KBq. The subjects of this study were the end-window Geiger-Muller type counter which were held at the calibration center certified by Korea Laboratory Accreditation Scheme (KOLAS) in March 2012, Cl-36 (Chlorine) and Sr-90 (Strontium) were used as the source of beta radiation. The measurement counting rate decreased with increasing wrap thickness, and the calibration factor increased with increasing wrap thickness. Since the changes of the measurement counting rate and the calibration factors can reduce the accuracy of the instrument readings, but also have a significant impact on detector contamination and damage, so there is a need to find out what thickness of wrap is most effective. If we using a wraps with thickness that show a low rate of change of the measurement counting rate and the calibration factor, it will protect the detector and minimize the effect on the measured value of the beta-rays.

Effect of Mechanical Stress on the Proliferation and Expression of Cell Cycle Regulators in Human Periodontal Ligament Cells (기계적 응력이 치주인대세포의 세포증식 및 세포주기 조절인자들의 발현에 미치는 영향)

  • You, Hyung-Keun;Shin, Hyung-Shik;Lee, Gene;Min, Byung-Moo
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.593-607
    • /
    • 1999
  • 치주인대세포는 치주인대의 유지와 개조에 있어서 중요한 역할을 담당하는 섬유아세포성 세포로서, 세포에 가해진 여러가지 조건에 따라 다양한 표현형의 변화를 나타내는 것으로 알려져 있다. 기계적 응력은 치주인대세포의 세포증 식과 밀접히 연관되어 있는 것으로 알려져 있으며, 이는 세포주기 조절인자들의 발현을 증가 시킴으로써 이루어질 것으로 생각되나 그 자세 한 작용기전은 알려져 있지 않다. 그러므로 이 연구의 목적은 기계적 응력이 사람 치주인대세 포의 세포증식과 세포주기 조절인자의 발현에 미치는 영향을 연구하기 위하여 사람 치주인대 세포에 기계적 응력을 가한 후 세포증식을 관찰하고 , 세포주기조절인자들인 p 53 , $p21^{WAF1/CIP1}$ cyclin-dependent kinases(cdks), cyclins 및 proliferating cell nuclear antigen(PCNA)의 단백질 발현 변화를 연구하였다. 본 연구에 사용한 사람 치주인 대세포는 교정치료를 목적으로 발거한 건전한 사람 소구치의 치주인대로부터 explantation culture하여 얻은 후 계대배양을 시행하여 제6 계대의 세포를 사용하였다. 배양한 사람 치주인 대세포를 55-mm Petriperm dish당 $1{\times}10^4$ 개를 분주하고, dish당 1kg의 기계적 응력을 가하면서 12일동안 세포배양을 시행하였다. 사람 치주인대세포의 세포증식은 기계적 응력을 가한 후 8-12일 사이에 현저히 증가하였으며, PCNA 단백질의 발현은 기계적 응력을 가한 후 6-10일 사이에 현저히 증가하였다. 또한 기계적 응력은 사람 치주 대세포의 cdk4, cdk6, cdk2 및 cyclin D1 단백질의 발현을 다소 증가 시켰으나, p53 및 $p21^{WAF1/CIP1}$ 단백질의 발현은 큰 변화가 없었다. 이상의 결과 서 기계적 응력은 사람 치주인대세포 의 p53 및 $p21^{WAF1/CIP1}$ 단백질 발현의 변화 없이 cdks 단백질 발현을 증가시킴으로써 세포증식을 증가시키는 것으로 생각된다.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFECT OF TOPICAL APPLICATION OF STANNOUS ELUORIDE TO THE STRIPPED ENAMEL SURFACE (불소가 삭제된 법랑질 표면에 주는 영향에 관한 실험적 연구)

  • Ro, Tae Rae
    • The korean journal of orthodontics
    • /
    • v.2 no.1
    • /
    • pp.23-28
    • /
    • 1971
  • In this study, sections of twenty eight teeth were used to investigate the effect of topical application of $8\%$ stannous fluoride on the decalcification rate of enamel surfaces stripped in a manner suggested for orthodontic purpose. The enamel treated with a single application of a fluoride had a significantly lower tile rate of decalcification for the first 96 hours to lactate buffer solution. After double application of fluoride, decalcification rate decreased signicantly. This study suggested that the continuing protection of stripped surfaces should be sought by regularly scheduled treatment of the enamel with the topical application of fluoride and regular use of a fluoride containing dentifrice.

  • PDF

A study on decision number of maintenance equipment with calibration for weapon system with Queueing Theory (검교정이 필요한 무기체계 정비장비의 구매 대수 결정을 위한 대기행렬이론 연구)

  • PARK, JUNGHO;LEE, IKDO;PARK, YEONKYOUNG;Kim, Du-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.153-162
    • /
    • 2017
  • Weapon systems have been developed with high technology electronic equipment due to technology growth. In addition, the capital, operational and maintenance costs of weapon systems have all increased. However, cost of operation and maintenance for weapon systems has been decreased relatively compared to the increased capital cost of weapon systems. Therefore, the defense industry needs to research the life cycle cost of weapon systems that have high operational and maintenance costs. This paper focuses on maintenance equipment for the operation and maintenance of weapon systems. Recently, it seems that the weapon systems that have periodic calibration with maintenance equipment are valid. The equipment requires periodic calibration by the manufacturer to check its own validation. Basically, customers demand high reliability devices from foreign companies that have qualified in the global market. Therefore, the tools need to be calibrated overseas. In other words, weapon systems are not available when the equipment has to be calibrated overseas because the systems require validation with valid maintenance equipment. A purpose of this paper is to compare the loss costs that arise from the calibration of the equipment overseas and the purchasing cost of the tools. Finally, the research shows the number of equipment that customers need to minimize the cost. This research will help to improve the efficiency of operation of weapon systems and solve the problems associated with the need for maintenance overseas.

Creep Characteristics Verification of FE Model for SnPb Solder (SnPb 솔더에 대한 유한요소모델의 크리프 특성 검증)

  • Han, Chang-Woon;Park, No-Chang;Oh, Chul-Min;Hong, Won-Sik;Song, Byeong-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • The heat sink system for a main board in a network server computer is built on printed circuit board by an anchor structure, mounted by eutectic SnPb solder. The solder creeping is caused by a constant high temperature condition in the computer and it eventually makes fatal failures. The FE model is used to calculate the stress and predict the life of soldered anchor in the computer. In the model, Anand constitutive equation is employed to simulate creep characteristics of solder. The creep test is conducted to verify and calibrate the solder model. A special jig is designed to mitigate the flexure of printed circuit board and to get the creep deformation of solder only in the test. Test results are compared with analysis and calibration is conducted on Anand model's constants. Precise life prediction of soldered anchor in creep condition can be performed by this model.

Application and effects of condylectomy in asymmetric patients with condylar hyperplasia (과두과증식을 동반한 안면비대칭 환자에서 과두절제술의 적용과 효과)

  • Lim, Kyoung-Sub;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.437-455
    • /
    • 2008
  • Condylar hyperplasia is a pathologic condition showing 3-dimensional skeletal hyperplasia of the mandible. The reason for condylar hyperplasia is not yet known, but the effects of hormone, trauma, infection, genetics, fetal condition, and hypervascularity are known as possible reasons. When we diagnose a patient as having condylar hyperplasia, it is important to decide if it is in progress or not. Treatment for facial asymmetry due to condylar hyperplasia are decided accordingly, including condylectomy, that is removal of growth site of the affected condyle, and conventional orthognathic surgery only or condylectomy with orthognathic surgery after the completion of growth. Therefore, it is important to determine the growth state of condylar hyperplasia in treatment stability. This is verified through bone scan and regular check-ups with 3D CT or PA cephalogram. This case report introduces an improved case of facial asymmetry with condylectomy together with orthognathic surgery.

IATROGENIC IMPACTION OF LOWER LEFT PERMANENT CANINE : CASE REPORT (하악 영구 견치의 의원성 매복에 대한 증례 보고)

  • Kim, Song-Yi;Choi, Sung-Chul;Choi, Yeong-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.339-344
    • /
    • 2008
  • When a delayed eruption of tooth is diagnosed, the causative factor should be detected before an establishment of treatment plan, if possible. Although a panoramic radiograph is enough to evaluate the position of tooth and the stage of tooth development, a 3-D Dental CT would be a powerful tool to reveal a spatial relationships between objects. The reported case showed a delayed eruption of lower left permanent canine and a mini-plate with screws adjacent to the impacted canine. Although the screws adjacent to the root of impacted tooth showed a close proximity, it was not presumed that these screws would interfere the eruption of the tooth. The impacted canine did not show any spontaneous eruption during observation. After the mini-plate and screws were removed, an orthodontic traction using elastic power chain was performed. The position of mini-plates and screws should be carefully designed to avoid damaging the tooth follicles or tooth roots in the jaw. Also the screws should be removed before an orthodontic traction to prevent damaging the root surface of impacted tooth.

  • PDF

Quantitative Analysis of Effects for Quality Control on Medical Primary Class LCD Display Devices Based on AAPM TG18 Report (AAPM TG18에 의한 진단용 LCD 디스플레이 장치 정도관리 효과의 정량적 분석)

  • Jung Hai-Jo;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.77-82
    • /
    • 2006
  • The image display is an Important component of PACS and of medical digital imaging chain. Displayed image qualify is affected by the physical characteristics of display device, appropriate clinical settings and calibrations, and ambient lighting conditions. The performance of display systems is continuously degraded over time due to luminance deterioration and changes of clinical setting parameters. A routine QC is recommended because the performance of display systems is continuously degraded over time. Ten flat panel monochrome LCD display devices were included in the evaluation of the QC effect. The effect of QC on primary class LCD medical display devices for selected QC tests was evaluated by comparing the performances, luminance response, luminance dependencies, display resolution and display chromaticity in this study, of before and after the calibration procedures. The effects of the QC are significant to luminance response and luminance spatial dependencies test and the other side, are slight to the display resolution and display chromaticity test. A routine QC of display device is essential for the consistency of medical image display and presentation. The study of the QC effects of display devices will play an important role in practical QC procedures of display devices.

  • PDF