• Title/Summary/Keyword: 교정용 선재

Search Result 17, Processing Time 0.027 seconds

Evaluation of the Cytotoxicity and Mechanical Strength of Dental Duplex Stainless Steel Orthodontic Wire (치과 교정용 듀플렉스 스테인리스 스틸 와이어의 기계적 강도 및 세포독성 평가)

  • Lee, Myung-Kon;Kim, Chi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.309-317
    • /
    • 2010
  • The stainless steel wire is extensively used for the orthodontic treatment. But, the stainless steel wire that has commonly superior corrosion resistance has caused hypersensitive reaction or allergy as side effects because of corrosion in the oral environment. For improving the problem of corrosion, we was evaluated the suitability of the duplex stainless steel(DSS) as orthodontic wire through this study. The DSS wire was evaluated the mechanical strength and bio-stability for suitability and bio-compatibility as orthodontic wire. In this work, the DSS and stainless steel(SS) as common use of medical grade were prepared for the tensile strength test. The DSS wire were treated by heat. and Temperature conditions of the heat treatment were $28^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$, $800^{\circ}C$, $900^{\circ}C$, respectively. And the DSS wires that treated by heat on the optimum temperature condition were conducted the bending moment test and calculated the S-Max value and the modulus of elasticity. For evaluating the bio stability, each materials were conducted in vitro test for measuring the cell survival rate. The most interesting results was that the tensile strength test of SS wire($8.17\times10^4\;N/mm^2$) and DSS wire($8.05\times10^4\;N/mm^2$) that treated at $500^{\circ}C$ by heat were similar in mechanical strength. In the bio-stability study, the DSS has no cytotoxicity (p=0.05) Thus, we could make a conclusion that the duplex stainless steel wire has vastly superior corrosion resistance was suitable as orthodontic wire.

The Frictional Resistance Of Tin Ion-Plated Co-Cr Orthodontic Wire (TiN 피막처리된 Co-Cr계 교정용 선재의 마찰저항력)

  • Lee, Ho-Kyu;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.123-133
    • /
    • 1998
  • The effectiveness of TiN ion-plating was examined with TiN ion-plated Co-Cr wires(.016“, .016”x.022“) on three different types of bracket(TiN ion-plated metal bracket ceramic bracket and plastic bracket). Maximum static frictional forces and characteristic curves obtained from the frictional characteristic graph, were compared and surface roughness of wires and bracket slots before and after friction experiment was observed by SEM. The obtained results were as follows $\cdot$The frictional forces of TiN ion-plated wires were significantly lower than those of non ion-plated wires(p<0.05). $\cdot$On the effect of wire shape, the frictional forces of round wires were significantly lower than those of rectangular wires(p<0.05) $\cdot$As the result of the SEM observation on the wires and bracket slots after the friction experiment the surface of non ion-plated wires was rougher than that of TiN ion-plated ones. $\cdot$The difference between the static frictional forces and the kinetic frictional forces was not significant in case of the TiN ion-plated round ins, but the static frictional forces were a little higher than the kinetic frictional forces in the TiN ion-plated rectangular wires. $\cdot$The static frictional forces were much higher than the kinetic frictional forces in the case of non ion-plated wires.

  • PDF

The moment generated by the torque of the orthodontic rectangular wire : Three-dimensional finite element analysis (교정용 각형선재에 부여된 torque가 브라켓에 발생시키는 모멘트에 관한 유한요소법적 분석)

  • Ha, Do-Won;Kim, Young-Suk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.335-346
    • /
    • 2001
  • The purpose of this study was to investigate the ideal clinical torque(In the SWA rectangular wire, the torque by the angle between the plane part and twisted part to move the tooth) of the orthodontic rectangular wire which produce the proper labiolingual movement of the single tooth during finishing stage of the orthodontic treatment. The clinical torque is the sum of the play and the active torque which generates the moment at the bracket. The play is calculated by the formula and the active torque is calculated by the computer aided three-dimensional finite element method. The finite element model was consist of the three brackets which formed a row and 3 kinds of orthodontic rectangular wire(stainless steel, TMA, NiTi) which inserted in brackets. Both sides of the model were twisted and the moment generated in the center bracket was calculated. The sizes of seven wires which were used commonly were .016'X.022', .017'X.022', .017'X.025', .018'X.025', .019'X.025', .020'X.025', .021'X.025'. In 018' bracket, 016'X.022', .017'X.022', .017'X.025' wires were inserted and in 022' bracket, all the sizes of wires except .016'X.022' were inserted and tested. The following conclusions could be drawn from this study. 1. The moments generated on the same size of the wires by the same active torque were equal regardless of the bracket slot size. 2. The moments were increased with the size of the wires. The moment generated on the .021'X.025' wire was about 1.75 times as large as that on the .016'X.022' wire regardless of the material. 3. The moments were increased in the order of the NiTi, TMA stainless steel. The moment of the TMA wire was 0.35 times as small as that of the stainless steel wire and the moment of the NiTi was0.16 times as small as that of the stainless steel wire. 4. The moment was decreased as the interbracket distance was increased. 5. To get a desired moment with the specific size and material of the wire on the specific bracket slot, the formula and the results were displayed.

  • PDF

Evaluation of cytotoxicity of electroplated stainless steel orthodontic wire (전기도금한 교정용 스테인레스스틸 선재의 세포독성에 관한 연구)

  • Lee, Gye-Hyeong;Cho, Jin-Hyoung;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.127-136
    • /
    • 2005
  • The purpose of this study was to examine the cytotoxicity of orthodontic wire which had an increased diameter through electroplating, and to evaluate its possible clinical applications, First. nickel plating was carried out on the commercially available stainless steel wire using an electroplating technique For the comparison of the electroplated wire with ready made stainless steel wire and titanium or copper. each wire was incubated for 72 hours in a medium. The release of the metal ion was measured using ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrophotometer). Balb/c 3T3 mouse fibroblast was put on a microplate and placed in an incubated medium of 75%, 50%, and 20% dilation. An MTT analysis was used to compare with the medium only. The change in absorbency value of each wire group and the difference of absorbency value according to the change of dilution was measured The results of ICP-AES analysis showed that great amount nickel iou was isolated from electroplated orthodontic wires and great amount copper ion was isolated from copper. The results of the MTT analysis showed that there was no difference in the absorbency value of titanium at any dilution. However, the electroplated wires (p<0.001) the stainless steel wires (p<0.05) and the copper (P<0.001) were statistically significantly lower than those of medium only at all dilutions. Assessment as per ISO 10993, part 5, showed that electroplated wire was alloted to 'moderate cytotoxic' the titanium and stainless steel wire were 'non-cytotoxic' The results of this study indicate that the electroplated orthodontic wires need additional efforts to decrease cytotoxicity for their clinical applications.

Changes in frictional resistance between stainless steel bracket and various orthodontic wires according to a change in moment (모멘트 변화에 따른 브라켓과 교정용 선재 사이의 마찰력 변화)

  • Jeong, Hye-Jin;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.137-149
    • /
    • 2007
  • Objective: The purpose of this study was to compare changes in frictional resistance between the bracket and wire under dry and wet conditions according to a change in moment. Methods: A stainless steel bracket of $0.022"{\times}0.028"$ slot, and $0.019"{\times}0.025"$ stainless steel, beta-titanium, and nickel-titanium wires were used. A 10 mm length lever was attached to the test (sliding) brackets to generate a moment. The experimental model was designed to allow tipping until contacts were established between the wire and the mesiodistal edges of the bracket slot. The moment was generated by suspending a 100 g or 200 g weight on the end of the lever. The moments applied were $1000g{\cdot}mm\;(100g{\times}10mm)\;and\;2000g{\cdot}mm\;(200g{\times}10mm)$. The test brackets were ligated with elastomeric ligature for a constant ligation force and the fixed brackets were ligated with stainless steel ligature. Brackets were moved along the wire by means of an universal testing machine, and maximum frictional resistances were recorded. Results: Stainless steel wire showed least frictional resistance and there was no significant difference between beta-titanium and nickel-titanium except at $2000g{\cdot}mm$ moment in wet conditions. Frictional resistance of all wires increased as the moment increased from $1000g{\cdot}mm\;to\;2000g{\cdot}mm$. Under wet conditions, the frictional resistance of stainless steel wires increased in both $1000g{\cdot}mm\;and\;2000g{\cdot}mm$ moment conditions, but frictional resistance of nickel-titanium and beta-titanium increased only in $2000g{\cdot}mm$ conditions. Conclusion: These results indicated that various conditions influence on frictional resistance. Therefore, laboratory studies of frictional resistance should simulate clinical situation.

Change of physical properties after diameter increase by electroplating of orthodontic rectangular stainless steel wire (전기도금을 이용한 스테인레스 스틸 각형 선재의 굵기 증가 후 물성 변화)

  • Lee, Jeong-Seok;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.131-140
    • /
    • 2003
  • The purpose of this study was to evaluate clinical applications of electroplating method through investigation of the physical properties of orthodontic rectangular wires according to varying their cross section. For the study, it was accomplished to electroplate the 0.016-inched orthodontic rectangular stainless steel wire. The cross section of stainless steel orthodontic rectangular wire increased from $0.016{\times}0.016inch\;to\;0.017{times}0.017inch$ by electroplating. The wire was heat treated to improve an adhesion between the wire and electroplated metal. h three-point bending test and torsion test were conducted in order to compare physical properties among three wire groups; $0.016{\times}0.016wires(group 016),\; electroplated\;0.016{\times}0.016wires(group\;016P)\;and\;0.017{\times}0.017$ wires (group 017). Through the investigations of each wire group, following results were obtained 1. At three-point bending test, the group Ol6P showed higher tendency in the degree of stiffness, yield strength and ultimate tensile strength than the group 016. Stiffness and ultimate tensile strength showed statistically significant differences between two groups at three-point bending test (p<0.05). 2. Stiffness, yield strength, and ultimate tensile strength of the group 016P showed lower tendency than those of the group 017 Stiffness showed statistically significant differences between two groups at three-point bending test (p<0.05). 3. Torque/twist rate, yield torsional moment, and ultimate torsional moment of the group 016P showed higher tendency than those of the group 016. All measurements showed statistically significant differences between two groups alter torsion test (p<0.05). 4. Torque/twist rate, yield torsional moment, and ultimate torsional moment of the group 0166P showed lower tendency than those of the group 017. Yield torsional moment, and ultimate torsional moment showed statistically significant differences between two groups after torsion test (p<0.05).

A comparative study of electroplating and electroless plating for diameter increase of orthodontic wire (교정용 선재의 직경 증가를 위한 전기도금법과 무전해도금법의 비교연구)

  • Kim, Jae-Nam;Cho, Jin-Hyoung;Sung, Young-Eun;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.145-152
    • /
    • 2006
  • The purpose of this study was to evaluate electroless plating as a method of increasing the diameter of an orthodontic wire in comparison with eletroplating. After pretreatment plating of the 0.016 inch stainless steel orthodontic wire, electroless plating was performed at $90^{\circ}C$ until the diameter of the wire was increased to 0.018 inch. During the process of electroless plating, the diameter of the wire was measured every 5 minutes to examine the increasing ratio of the wire's diameter per time unit. And to examine the uniformity, the diameter at 3 points on the electroless-plated orthodontic wire was measured. An X-ray diffraction test for analyzing the nature of the plated metal and a 3-point bending test for analyzing the physical property were performed. The electroless-plated wire group showed a increased tendency for stiffness, yield strength, and ultimate strength than the electroplated wire group. And there was a statistically significant difference between the two groups for stiffness and ultimate strength. In the electroless-plated wire group, the increasing ratio of the diameter was $0.00461{\pm}0.00003mm/5min$ (0.00092 mm/min). In the electroplated wire group, it was $0.00821{\pm}0.00015mm/min$. The results of the uniformity test showed a tendency for uniformity in both the plating methods. The results of this study suggest that electroless plating of the wire is closer to the ready-made wire than electroplating wire in terms of the physical property. However, the length of plating time needs further consideration for the clinical application of electroless plating.

An experimental study of dynamic frictional resistance between orthodontic bracket and arch wire (교정용 브라켓과 강선 사이의 운동마찰저항력에 관한 실험적 연구)

  • Lee, Jae-Hwan;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.31 no.4 s.87
    • /
    • pp.467-477
    • /
    • 2001
  • This investigation was designed to determine the effects of wire size, bracket width and the number of bracket on bracket-wire dynamic frictional resistance during simulating arch wire-guided tooth movement in vitro. For simulation of an arch wire-guided tooth movement, we simulated tooth, periodontal ligament and cancellous bone. Maxillary premolar and 1st molar were simulated as real sized resin teeth, the simulated resin teeth which its root was coated by polyether impression material which its elastic modulus is similar to periodontal ligament were embedded in steel housing with inlay wax which its elastic modulus is similar to cancellous bone. Stainless steel wires in four wire size (0.016, 0.018, $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch) were examined with respect to three (stainless steel) bracket widths (2.4, 3.0, 4.3mm) and the number of medium bracket(one, two, three) included in the experimental assembly under dry condition. The wires were ligated into the brackets with elastomeric module. The results were as follows : 1. In all the brackets, frictional resistance increased with increase in wire size. But, statistically similar levels of frictional resistance were observed between 0.018 inch and $0.016\;{\times}\;0.022$ inch wires in narrow bracket and also between 0.016 inch and 0.018 inch wire in wide backet. 2. The frictional forces produced by 0.016 inch wire were statistically similar levels in all the brackets. In 0.018 inch round wire, wide bracket was associated with lower amounts of friction than both narrow and medium brackets. In $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch rectangular wire, wide bracket produced target friction than both narrow and medium brackets. In all the wirer, narrow and medium bracket demonstrated no statistical difference in levels of frictional resistance. 3. Frictional resistance increased with increase In number of medium bracket. 0.016 inch round wire demonstrated the greatest increment in frictional resistance, followed by $0.019\;{\times}\;0.025,\;0.016\;{\times}\;0.022$ inch rectangular wire which were similar level in increment of frictional resistance, 0.018 inch wire demonstrated the least increment. The increments of frictional resistance were not constantly direct proportion to number of bracket.

  • PDF

An experimental study on diameter increase of orthodontic wire by electroplating (전기도금을 이용한 스테인레스 스틸 선재의 직경 증가에 관한 실험적 연구)

  • Cho, Jin-Hyoung;Sung, Young-Eun;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.121-130
    • /
    • 2003
  • The purpose of this study was to evaluate the possibile clinical application of electroplating to increase diameter of an orthodontic wire, through examining the change of physical properties. The diameter of stainless steel orthodontic wire was increased from 0.016 inch to 0.018 inch by electroplating in a bath of nickel sulfate 100g/L, nickel chloride 60g/L, boric acid 30g/L, and sodium chloride 50g/L, under the conditions of 1.7V, $25\~29^{\circ}C\;and\;3.1\~3.3pH$. During the electroplating, the rate of diameter increase was measured every minute. To investigate uniformity, the diameter was measured at three different locations of each wire specimen aster electroplating. An X-ray diffraction test was performed to analyze the nature of the electroplated metal. Following heat treatment to improve adhesion between the wire and electroplated metal, a three-point bending test was conducted to compare stiffness, field strength, and ultimate strength among four wire groups; 0.016 inch, electroplated 016, electroplated and heat-treated 016, and 0.018 inch wires. Through the comparison of each wire group, following results were obtained. 1. In the load-deflection graph, the curve of the electroplated group was Placed between that of the 0.016 inch group and the 0.018 inch group, and the owe was closer to the 0.018 inch group by heat treatment. 2. In the electroplated and heat-treated 016 wire group, the values of stiffness, yield strength and ultimate strength showed higher tendency than in the original 0.016 Inch group. Stiffness and ultimate strength showed statistically significant differences between two groups. 3. Stiffness, yield strength, and ultimate strength of electroplated wire presented lower values than those of 0.018 inch wire group. 4. Stiffness, yield strength, and ultimate strength of electroplated and heat-treated wire showed higher tendency than those of electroplated wire group, and ultimate strength showed statistically significant difference between two groups. 5. After electroplating, the difference in diameter between the three locations was within $0.1\~0.3\%$ variation, and showed no statistical significance.

A STUDY CONCERNING THE CHARACTERISTICS OF KOREAN NI-TI ALLOY ORTHODONTIC WIRE (국산 Ni-Ti합금 교정용 선재의 특성에 관한 연구)

  • Park, Dong-Ok;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.187-200
    • /
    • 1995
  • To estimate the characteristics of Korean Ni-Ti alloy orthodontic wire, this study investigated compositions, tensile properties, bending properties, heat treatment effects, and ion releasing degrees, and compared these characteristics to those of the imported Ni-Ti alloy wire. The results obtained are as follows ; 1. Ti and -Ni elements in ORTHOLLOY were in a range showing superelasticity, and there was a little difference in the Ni and Ti contents of ORTHOLLOY as compared with those of SENTALLOY. 2. The results of the tensile test concerning ORTHOLLOY exhibited a superelastic effect, indicating an area of a definite amount of stress in spite of the changes in the range from $2\%\;to\;8\%$ in the strain rate. 3. ORTHOLLOY presented higher load values than SENTALLOY in the same deflection values when the wire was tested in three-point bending. A load range displaying a superelastic effect was 80-l00g, 140-l80g, and 130-200g respectively, in wire diameters of 0.014', 0.016', and 0.018' 4. By heat treatments at $400^{\circ}C$ and at $500^{\circ}C$, a load range showing the effect of superelasticitly was lessened by the duration of the heat treatment time. The superelastic effect was destroyed as a result of the 10 minutes heat treatment at $600^{\circ}C$. 5. The quantity of the Ni ion released from ORTHOLLOY, tended to be greater than the amount of released Ni ion in SENTALLOY. The Co ion released was very little(<0.01ppm) in SENTALLOY and ORTHOLLOY irrespective of the lapse of time. Released Ni ions on the 1st day were at the maximum, and the releasing rate showed plateaus after three days. 6. The surface morphology of SENTALLOY was relatively regular irrespective of the lapse of rime, and the corrosion tendency was not observed. However, the surface morphology of ORTHOLLOY was rather irregular and shelved fitting corrosion after immersion.

  • PDF