• Title/Summary/Keyword: 교정시험

Search Result 247, Processing Time 0.034 seconds

Standard Neutron Irradiation Facility for Calibration of Radiation Protection Instruments by Radioactive Neutron Sources (방사성 중성자선원에 의한 방사선방어측정기의 교정을 위한 표준 중성자 조사장치 연구)

  • Choi, Kil-Oung;Lee, Kyung-Ju;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.66-70
    • /
    • 1989
  • In routine testing, the radioactive neutron sources are particularly suitable for producing standard. neutron fields. The ISO TC-85 has proposed neutron reference radiation for the calibration of neutron measuring devices used for radiation protection purposes. Radiation laboratory of KSRI has installed a standard irradiation facility using $^{252}Cf$ and $^{241}Am-Be$ sources for calibrating personal dosimeters according to the recommendations given in ISO TC-85. In this study, correction factors for calibration related to neutron scattering and anisotropy are obtained by experiments with commercial rem meter for demonstration purposes.

  • PDF

The Reference System For The Test of Precision Power Meter And Watthour Meter (정밀전력계와 적산전력량계의 시험을 위한 기준시스템)

  • Park, Y.T.;Yu, G.M.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.928-930
    • /
    • 2000
  • 교류전력을 측정하기 위하여 알고 있는 직류전력과 동시에 비교할 수 있는 전력비교기를 개발하였으며 이 비교기를 기본으로 하여 정밀 전력계와 전자식 전력량계를 교정하거나 시험검사 할 수 있는 기준시스템인 전력표준기를 개발하였다. 특히 Push-Pull 기술을 이용한 전력비교기는 간단하며 정확도가 매우 높은 것으로 평가되었으며 전력비교기의 전체 불확도는 30 $\mu$ W/VA로 평가되었다.

  • PDF

Evaluation of Energy Dependency for Air Kerma Area Product by RQR Beam Quality and Indirect Calibration (RQR 선질에 따른 공기커마 면적선량계의 에너지 의존성 평가와 간접 교정)

  • Kim, Jung-Su;Kim, Sung-Hwan;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.769-776
    • /
    • 2018
  • According IEC 60601-1 ed3.1 and IEC 60601-2-45 regulation, diagnostic X-ray equipment should be display to measured and calculated air kerma area product. On the clinical X ray equipment, air kerma area product dosimeter would like to have an evidence for dosimeter accuracy and energy dependency. This study was performed to indirect calibration and energy dependency test for attached type air kerma area product (KAP) dosimeter by RQR standards beam quality. On the RQR5 beam quality, attached KAP dosimeter error showed -7.5%, respectably. On the RQR9 beam quality, attached KAP dosimeter error showed -10.4%, respectably. All RQR beam quality, average absolute error was $8.30%{\pm}2.85%$, respectably. On this study, attached KAP dosimeter was satisfied to IEC 60580 and AAPM TG 190. This calibration method of KAP dosimeter will help to performance maintain for clinical KAP dosimeter.

CDN을 이용한 전자파 전도내성시험의 측정불확도

  • Mun Jun-Cheol;Im Yeong-Chae
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.56
    • /
    • pp.84-92
    • /
    • 2005
  • 본 논문은 CDN(Coupling/Decoupling Network)을 이용한 전자파 전도 내성 시험의 측정 불확도를 연구하였다. 측정 불확도의 영향 인자를 추출하여 인자별 불확도를 산출하였다. 측정 불확도 인자는 인가 레벨 교정시 반복 측정, $150\sim50\Omega$ 아답터의 삽입 손실, 신호 발생기의 정확도, 파워미터의 정확도, 전력 증폭기의 하모닉, 전력 증폭기와 CDN의 부정합, CDN과 파워미터 사이의 부정합에 의한 불확도를 고려하였다. 불확도 산출 결과 확장 불확도는 95% 신뢰 구간에서 1.17 dB(k=)를 가지며, 정보기기의 경우 시험 전압 3 V에서 ${\pm}0.42V$의 오차 범위를 가지는 것을 알 수 있었다. 또한 시험기기간의 부정합에 의한 불확도가 불확도 인자에서 가장 큰 영향을 미치는 것을 알 수 있었으며, 전자파 전도 내성 시험의 경우 임피던스 매칭이 가장 중요한 것으로 나타났다.

Change of physical properties after diameter increase by electroplating of orthodontic rectangular stainless steel wire (전기도금을 이용한 스테인레스 스틸 각형 선재의 굵기 증가 후 물성 변화)

  • Lee, Jeong-Seok;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.131-140
    • /
    • 2003
  • The purpose of this study was to evaluate clinical applications of electroplating method through investigation of the physical properties of orthodontic rectangular wires according to varying their cross section. For the study, it was accomplished to electroplate the 0.016-inched orthodontic rectangular stainless steel wire. The cross section of stainless steel orthodontic rectangular wire increased from $0.016{\times}0.016inch\;to\;0.017{times}0.017inch$ by electroplating. The wire was heat treated to improve an adhesion between the wire and electroplated metal. h three-point bending test and torsion test were conducted in order to compare physical properties among three wire groups; $0.016{\times}0.016wires(group 016),\; electroplated\;0.016{\times}0.016wires(group\;016P)\;and\;0.017{\times}0.017$ wires (group 017). Through the investigations of each wire group, following results were obtained 1. At three-point bending test, the group Ol6P showed higher tendency in the degree of stiffness, yield strength and ultimate tensile strength than the group 016. Stiffness and ultimate tensile strength showed statistically significant differences between two groups at three-point bending test (p<0.05). 2. Stiffness, yield strength, and ultimate tensile strength of the group 016P showed lower tendency than those of the group 017 Stiffness showed statistically significant differences between two groups at three-point bending test (p<0.05). 3. Torque/twist rate, yield torsional moment, and ultimate torsional moment of the group 016P showed higher tendency than those of the group 016. All measurements showed statistically significant differences between two groups alter torsion test (p<0.05). 4. Torque/twist rate, yield torsional moment, and ultimate torsional moment of the group 0166P showed lower tendency than those of the group 017. Yield torsional moment, and ultimate torsional moment showed statistically significant differences between two groups after torsion test (p<0.05).

A Study on Embankment Compaction Control System using RI Gauge (I) -Focuses on the Inspection and Calibration of Radio-Isotope Density/Moisture Gauges- (RI계기를 이용한 성토시공 관리기법 연구 (I) -RI계기의 검증실험 및 교정식 작성-)

  • Koo, Bon Hyo;Na, Kyung Joon;Lee, Jin Hoo;Hong, Sung Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.203-216
    • /
    • 1994
  • The laboratory methods for compaction of soil (KSF 2312) and for moisture of soil (KSF 2306) in combination with the soil density in place by the sand-cone method (KSF 2311) are generally used for compaction control of soils. However, these methods have limitations in number of test and in accuracy. ]n addition, they are time-consuming. Therefore, they are not adequate for speedy control of embankment compaction in a project with huge amount of earthwork. The RI (Radioisotope) gauges for measurement of soil density and/or of soil moisture are widely used for the compaction control of soils in many countries. But in Korea, they have had a limited usage and available informations for uses of RI gauges are insufficient. Therefore, this study promotes efficient and safe use of RI gauges in geotechnical engineering. In this paper, fundamental aspects such as the priciples of RI gauges, gauge inspection techniques and the applicability and limitations of RI gauges for field usage were reviewed. And a new calibration curves suitable for the Korean soils were suggested.

  • PDF

Fracture strength of tie wings in a newly-developed polycarbonate bracket (국산 폴리카보네이트 브라켓 윙의 파절 강도에 관한 연구)

  • Sun, Min-Kyu;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.204-211
    • /
    • 2007
  • Objective: With an increasing demand for esthetic orthodontic appliances, the interest in polycarbonate brackets has also increased. However, polycarbonate bracket wings are prone to fracture. The purpose of this study was to evaluate the clinical usefulness of a newly-developed polycarbonate bracket by measuring the fracture strength of bracket tie wings. Methods: Alice (K.M. Daicom, Seoul, Korea) and Spirit MB (Ormco, Glendora, CA, USA) brackets were used as an experimental and control bracket respectively. Each bracket group was divided into halves. One half was untreated and the other half was treated with 2,000 times of thermocycling between $5^{\circ}C\;and\;55^{\circ}C$. The fracture strength of the wing was measured by a universal testing machine. Results: Alice bracket wings showed significantly higher strength than Spirit MB bracket wings in both untreated and thermocycled bracket cases. Conclusion: Alice brackets may be used clinically in terms of the strength of bracket wings.