• Title/Summary/Keyword: 교정상수

Search Result 47, Processing Time 0.031 seconds

A Method for Determining Dead Times of a G.M. Defector as a Function of the Count Rate

  • Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.3-7
    • /
    • 1971
  • A method for determining dead times of a G.M. detector as a function of the count rate has been investigated using the Mn$^{56}$ radioactive sample. The formula, (equation omitted), seems to be useful for determining a relation between the dead time and the count rate. Here (equation omitted)(N$_1$) is the dead time for the count rate N$_1$, N$_1$is the count rate at time zero, Nt is the count rate at time t, λ is the radioactive decay constant of the sample used, and t is the time between the first and second runs. When all the counting data were corrected for the dead times evaluated with this formula and then a variation of these corrected counting data with rime was observed, the results showed quite a good agreement with the published data for the radioactive decay of Mn$^{56}$ . Besides, it appears that the dead time decreases as the count rate increases in a dead time-to-count rate relation obtained by the same formula.

  • PDF

Construction of Low Magnetic Standard System using a Multi-layer Solenoid with Single-current (단전류-다층 솔레노이드 방법을 사용한 저자장 표준시스템 제작)

  • 박포규;김영균
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.1
    • /
    • pp.38-44
    • /
    • 2001
  • The magnetic field standard below 1 mT with the resolution of 0.26 nT has been established. Earth magnetic field (EMF) is compensated automatically down to 0.1 nT/10 min. by a closed feedback system with Cs optical pumping magnetometer and 3-axis Helmholtz coils in nonmagnetic facilities. A multi-layer precision solenoid with the optimized single-current method generates the uniform magnetic field better than 1.0$\times$10$\^$-7/ within $\pm$ 1 cm region at its center. The coil constant of solenoid determined from Helium optical pumping magnetometer is 1.231 058 9 mT/A, and temperature coefficient is 0.38 nT/$\^{C}$. This standard system is used for calibration of low field magnetometers and testing relates to low field.

  • PDF

Outlier-Object Detection Using an Image Pair Based on Regression Analysis: Noise Variance Estimation and Performance Analysis (영상 쌍에서 회귀분석에 기초한 이상 물체 검출: 잡음분산의 추정과 성능 분석)

  • Kim, Dong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.5
    • /
    • pp.25-34
    • /
    • 2008
  • By comparing two images, which are captured with the same scene at different time, we can detect a set of outliers, such as occluding objects due to moving vehicles. To reduce the influence from the different intensity properties of the images, an intensity compensation scheme, which is based on the polynomial regression model, is employed. For an accurate detection of outliers alleviating the influence from a set of outliers, a simple technique that reruns the regression is employed. In this paper, an algorithm that iteratively reruns the regression is theoretically analyzed by observing the convergence property of the estimates of the noise variance. Using a correction constant for the estimate of the noise variance is proposed. The correction enables the detection algorithm robust to the choice of thresholds for selecting outliers. Numerical analysis using both synthetic and Teal images are also shown in this paper to show the robust performance of the detection algorithm.

Case study of application on pelvic manipulation which low back pain patient in unilateral weight bearing due to pelvic imbalance (골반 불균형에 의한 편측체중지지 요통환자의 골반도수교정 적용사례)

  • Kim, Han-Il;Kim, Sang-Su;Kim, Gee-Sun;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • Purpose: to recognized that influence of decrease low back pain, change pelvic structure and balance control on unilateral weight bearing after application on pelvic manipulation which low back pain patient in unilateral weight bearing due to pelvic imbalance. Methods: The patient with low back pain in unilateral weight bearing due to pelvic imbalance was 39year female. one subject received intervention of pelvic manipulation on sidelying position and reaching exercise on sitting position which during 2 weak at the 3 time per a weak, each 30 minutes. outcomes measured were Facia l Action Coding System(FACS), Radiograph(Lumbar-Spine Anteroposterior AP.), Pressure Scan. Results: The results of this study were summarized below : 1. FACS score were Pre: min.4 - max.6 and Post: min.2 - max.4. 2. Radiograph measured Ilium width were Pre: Lt.14cm, Rt.12.7cm and Post: Lt.13.4cm, Rt.13cm which discrepancy of Ilium height were Pre: 1cm and Post: 0.2cm. 3. Pressure scan measured Pre: Lt. 36.8%, Rt.40.2% and Post: Lt.41.3%, Rt.36.2%. Conclusion: Pelvic manipulation applied a patient with low back pain in unilateral weight bearing due to pelvic imbalance suggest that can decrease low back pain, change pelvic structure and balance control on unilateral weight bearing.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

An Experimental Study for Determination of the Material Diameter of Riprap Bed Protection Structure (사석 바닥보호공 재료 입경 결정을 위한 실험 연구)

  • Rhee, Dong-Sop;Yeo, Hong-Koo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1036-1039
    • /
    • 2005
  • 하상유지시설의 하류에 설치되는 바닥보호공은 국내의 경우 일반적으로 사석(riprap)이나 돌망태(gabion mattress) 등을 이용하여 시공되고 있으며, 바닥보호공에 사용되는 재료는 유속에 따라 적절한 입경의 재료를 결정하여 사용하게 된다. 1970년대 중반부터 적절한 하상보호공 재료를 결정하기 위한 연구는 사석, 돌망태, 콘크리트 보호 블록 등에 대하여 순차적으로 이루어져 왔다, 초기 연구는 주로 사석에 대해서 이루어졌으며, 중량과 유속 관계를 이용하여 사석 입경 결정 공식을 제안하였으며, 점차 수심 및 하상 경사, 난류 강도 등을 고려하여 재료 입경 결정 공식을 정밀화시켜왔다. 공식에 난류 강도를 고려하기 시작하면서, 단순한 하상보호공 재료를 결정하기 위해서 제안되었던 공식들은 하천 구조물 하류에 설치되는 바닥보호공으로 관심의 대상이 옮겨가기 시작하였다. 기존의 공식들이 일반적인 평탄한 하상보호공으로부터 구조물 하류의 바닥보호공 까지 그 적용이 확장되었던 반면에, Escarameia와 May는 연구의 대상을 수리구조물 하류의 강한 난류 흐름이 발생하는 구간으로 범위를 한정하여 연구를 진행하였으며, Izbash 형태의 식을 기초로 하여, 난류 강도가 주요 변수가 되는 입경 결정 공식을 제안하였다. 본 연구에서는 Escarameia와 May의 연구 결과를 기초로 하여, 국내 하상유지시설 하류에 설치되는 사석 바닥보호공 재료의 입경을 결정하기 위한 실험을 수행하였다. 하천설계기준을 만족하는 실험용 보를 설치한 후 유량 및 실험에 사용된 사석의 입경을 변화시키면서, 유속을 측정하여, 입경별 한계 유속(threshold velocity)의 상관관계를 분석하였다. 실험 결과, Escarameia와 May가 제안한 공식을 더 확장하여 적용할 수 있는 실험 공식으로 개선하였으며 다양한 조건에 대한 실험을 수행하여 보다 정밀한 공식으로 개선할 수 있었다.$10,924m^3/s$ 및 $10,075m^3/s$로서 실험 I의 $2,757m^3/s$에 비해 통수능이 많이 개선되었음을 알 수 있다.함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한 HSP 환자군에서도

  • PDF

Comparison of Discharge Characteristics of NPS Pollutant Loads from Urban, Agricultural and Forestry Watersheds (유역으로부터 배출되는 비점원 오염부하의 토지이용에 따른 특성 비교)

  • Yur, Joong-Hyun;Kim, Geon-Ha;Kim, Jeong-Kon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1214-1218
    • /
    • 2005
  • 지금까지 국내에서의 수질개선을 위한 노력은 점오염원에 대한 저감만을 중심으로 진행되어 왔기 때문에, 보다 획기적인 수질개선을 위해서는 비점오염에 대한 연구와 관리가 진행되어야 한다. 그러므로 본 연구에서는 도시지역, 농촌지역, 임야지역의 토지이용특성이 다른 3유역을 대상으로 현장연구를 실시하여 비점오염물질의 발생특성 및 유역별 비교를 실시하였다. 측정은 도시지역의 가장 큰 오염원인 CSOs(Combined Sewer Overflows)에 대하여 측정을 실시하였고, 농촌지역 및 임야지역의 경우 각 유역의 출구 지점에서 측정을 실시하였다. 강우특성이 다른 15개의 강우사상을 대상으로 유량 및 SS, TCOD, TN, TP의 항목에 대하여 한 강우사상당 $15\~20$회의 측정을 실시하였다. 각각의 강우사상에 대하여 EMCs(Event Mean Concentrations)를 산출하여 도시지역, 농촌지역, 임야지역의 각 유역에 대한 확률별 EMCs를 산정한 결과 3개 유역의 EMCs는 도시지역>농촌지역>임야지역 순으로 나타났다. $EMC_{TCOD}$는 도시지역과 농촌임야지역간에 가장 큰 차이를 보이는 것으로 나타났으며, $EMC_{TN}$에서 가장 작은 차이가 나타났다. 각 유역별 EMCs의 로그-정규 확률그래프의 분산계수를 비교한 결과 농촌임야지역은 도시지역에 비하여 오염물질의 농도 변화가 강우특성에 따라 보다 큰 변화를 보이는 것으로 나타났다. 연구유역에서 $EMC_{TN}$의 발생확률 $50\% 값이 도시지역은 17.0mg/L, 농촌임야지역은 4.5mg/L로 나타났으며, 이는 유사한 유역특성을 나타내는 타 지역에서의 연구자료를 분석 값과 매우 유사한 크기를 가지는 것으로 나타났다.를 분석하였다. 실험을 수행하여 보다 정밀한 공식으로 개선할 수 있었다.$10,924m^3/s$ 및 $10,075m^3/s$로서 실험 I의 $2,757m^3/s$에 비해 통수능이 많이 개선되었음을 알 수 있다.함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해

  • PDF

Application of CFD model for the design of settling basin inlet structure (침전지 유입부 설계를 위한 CFD모형의 적용)

  • Yu Chang Hwan;Lee Jong Hyun;Kim Dae Geun;Kim Nam Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1083-1087
    • /
    • 2005
  • 하수처리장의 침전지는 고형물(SS)을 침전, 제거하여 하수를 정화하는 시설로서 생물학적처리에 의해 발생하는 슬러지와 처리수를 분리하는 것을 주목적으로 한다. 장방형침전지의 경우, 유입된 하수가 침전지의 전 단면에 걸쳐 균일하게 도달하게 하기 위하여 $6\~20\%$ 정도의 유공율을 가진 유공정류벽을 설치하며 유효 침전구역에서의 유속은 0.08 m/sec 이하가 되도록 설계되어야 한다. 지금까지 침전지 유입부의 설계시에는 상기 설계기준만을 참조하여 설계가 진행되고 있는 실정으로 보다 나은 대안을 도출하기 위한 분석은 미흡한 실정이다. 본 연구에서는 3차원 수치모형인 FLOW-3D를 이용하여 침전지의 유입부 설계를 위한 설계인자를 도출하였다. 특히 유공정류벽의 크기, 위치 유공율에 따라서 유입하수의 수리적인 특성을 3차원적으로 분석하였다. 저류벽의 위치에 따른 유량의 분배효과를 검토하기 위하여 저류벽의 폭, W를 2.4 m로 고정하고 유입부에서 저류벽까지의 거리, L을 1.5 m, 2.0 m, 2.5 m로 변화시키며 수치모의를 수행하였다. 그리고 저류벽의 폭에 따른 유량의 분배효과를 검토하기 위하여 L을 고정하고 W를 변화시키며 수치모의를 수행하였다. 유공정류벽의 유공율에 따른 유량의 연직 분배효과를 검토하기 위하여 유공율을 변화시키며 연직위치별 통과유량을 산정하였다 각 모의조건에 대한 통과유량 산정결과, 유공율이 $7\%$일때 통과유량의 표준편차가 가장 작게 발생하며, 유공율이 $7\%$보다 감소하거나 증가하면 표준편차가 증가하고 있음을 알 수 있다. 본 연구에서는 상용 CFD모형인 FLOW-3D를 계획 중인 하수처리장의 침전지 유입부 설계에 적용하였으며 저류벽의 위치와 폭, 유공정류벽의 유공율에 따른 유입하수의 분배효과를 분석하였다. 실험을 수행하여 보다 정밀한 공식으로 개선할 수 있었다.$10,924m^3/s$ 및 $10,075m^3/s$로서 실험 I의 $2,757m^3/s$에 비해 통수능이 많이 개선되었음을 알 수 있다.함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조

  • PDF

A Study on Sewage Characteristics in Hanam City (하남시 오수발생특성에 대한 연구)

  • Choi, Gye-Woon;Hyun, Ji-Hwan;Lee, Ho-Sun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1317-1322
    • /
    • 2005
  • 하수관거 설계시나 단지개발사업, 그리고 하수관거정비사업과 같이 오수처리시설의 적정 규모 결정을 위해서는 정확한 상수사용량 및 오수발생량 원단위가 요구되지만 국내의 경우 이러한 원단위에 대한 기초자료 부족과 자료의 신빙성 결여로 인해 적정 원단위를 결정하는데 어려움이 있다. 이러한 관점에서 단지개발이 이루어지는 도시에서는 도시의 규모, 입지조건, 기후조건, 생활양식 등 다양한 요인들이 고려된 오수발생패턴 및 발생량 조사가 필요하며, 조사된 원단위는 오수처리시설의 적정 규모 결정뿐 아니라 침입수/유입수 분석 및 하수관거정비에 대한 성과예측에도 활용될 수 있다. 본 연구에서는 현재 단지개발 및 하수관거정비사업이 진행중인 하남시의 표본이 될 수 있는 대표구역을 선정하고 그 지역에서 조사지역을 세부적으로 분류하여 각 지역별 오수발생특성을 분석하였다. 대상지역인 하남시는 총면적의 $97\%$가 자연녹지 및 생산녹지이며, 나머지 $3\%$는 일반주거지역 및 일반 상업지역으로 나뉜다. 그리고 도시계획상 공장지역으로 편성된 부분이 없어 앞으로도 하남시 대부분의 면적이 녹지와 주거/상업지역으로 구성될 것이다. 이러한 하남시의 특성을 고려하여 조사지역은 공장지역을 제외한 일반주거지역, 밀집주거지역, 영업지역으로 분류하였으며 이렇게 분류된 지역은 각각 오수발생패턴 및 오수농도에 대한 조사를 실시하여 오수발생특성을 분석하였고, 조사지역별 인구수 조사와 연계하여 원단위 자료를 추출하였다. 이렇게 조사된 자료들을 통해 침입수/유입수 분석에 요구되는 오수전환율, 야간생활하수량 비율을 산정하였으며, 차후 단지개발 및 관거정비 후에 발생하는 오수 발생특성과 비교분석을 통하여 하남시 지역의 오수발생특성에 대한 신뢰성 있는 자료로 활용될 것으로 기대된다. RMA2 모형을 이용하여 충주댐에서의 물의 흐름을 해석한 결과 옥순대교$\~$청풍대교 구간 사이에 댐 및 지형적 영향으로 인해 잘 발달된 와류가 하도 전체를 통하여 발생되고 있었고 이는 댐 부유물 정체현상이 나타나는 지점과 잘 일치하고 있었다.정함 후 감마분석에 의하여 구하였다. CF:CS 연령모델을 적용한 결과 깊이에 따른 supported $^{210}Pb$와 퇴적 속도는 0.91cm/year 인 것으로 산정 되었다.RS is a more advanced content-based image retrieval system than other systems which support only concepts or image features.방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주

  • PDF