• Title/Summary/Keyword: 교상

Search Result 132, Processing Time 0.032 seconds

EFFECT OF DRAINAGE VIA DENTAL ROOT CANAL & EXTRACTION WOUND IN THE UNCONSCIOUS PATIENT WITH CONTINUOUNS SELF-BITE WOUNDS (지속적인 교상을 가진 무의식 환자에서 치근관 및 발치창 통한 배농술의 효과 : 증례 보고)

  • Kim, Jong-Bae;Yoo, Jae-Ha;Choi, Byung-Ho;Moon, Seon-Jae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.457-463
    • /
    • 2001
  • In the unconscious patient with general muscle rigidity, the natural teeth can be luxated and then bite wounds may be occurred around lip, owing to the pathologic involuntary self-biting habit. If the forceful biting is generated continuously, the teeth may be avulsed and aspirated into the aerodigestive tract with the infection of biting wound. For the prevention of pulmonary aspiration of the teeth and wound infection, the biting teeth should be cared before the fact. The authors treated the teeth as endodontic drainage with removal of the crown or iodoform gauze drainage into the socket with extraction of the teeth. The prognosis was more favorable without biting wounds.

  • PDF

System Development of Molten Carbonate Fuel Cell for Power Utility(Test Results and Development Status (발전용 용융탄산염 연료전지 기술 개발(시스템 운전결과 및 개발현황))

  • Lim, Hee-Chun;Ahn, Kyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1145-1146
    • /
    • 2006
  • 분산 형 전원 및 석탄 가스화와 연계한 복합 발전이 가능한 용융탄산염 연료전지(MCFC : Molten Carbonate Fuel Cell)는 천연가스, 석탄가스 등 다양한 연료를 사용할 수 있고, 공해요인이 적고, 높은 에너지 변환효율을 가지고 있어 전력사업 분야에 적용 가능성이 가장 큰 새로운 발전방식이다. 국내에서도 1993년부터 선도기술개발 사업의 하나로 시작하여 현재 250 kW급 발전시스템 개발 연구가 진행되고 있다. 250 kW개발 전 수행한 100 kW급 MCFC 발전 시스템 개발 연구에서는 6,000cm2 급 단위전지 90장으로 구성된 50 kW급 MCFC 스택 2기 로 구성된 100 kW MCFC 스택과 이를 운전 평가를 위한 시스템을 완성하였다. 2005년부터 스택운전에 필요한 시스템 내 단위기기들에 대한 시운전을 진행 한 후 장착된 100 kW MCFC 스택 운전에서는 시스템 단위 기기의 고장으로 전 부하운전을 실시하지 못했지만 상압 상태에서 AC 50 kW 전력을 계통과 연계 운전 시험을 진행하였다. 향후 100 kW MCFC 시스템 보완후 재 운전 시험을 진행할 예정이다. 한편 병행하여 진행되는 250 kW 열병합 발전 시스템 개발에서는 시스템 상세설계 및 신형 분리판을 이용한 새로운 형태의 스택을 개발 운전시험을 진행하고 있다. 여기에서는 MCFC 발전 시스템의 개요와 시스템의 운전을 위한 운전 모드 그리고 스택 운전 내용을 요약하여 소개하고자 한다.

  • PDF

A Study on the Optimal Design of Large-scale Photovoltaic Array (대용량 PV 어레이의 최적설계에 관한 연구)

  • Hwang, In-Ho;Kim, Eui-Hwan;Ahn, Kyo-Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.8-14
    • /
    • 2011
  • Recently, a number of large-scale photovoltaic(PV) power generation system has been installed all over the world. Thus, in order to improve the system efficiency, the optimal design of the large-scale PV systems has become an important issue. DC cable loss of PV array is one of the design factors related to the system efficiency. This paper introduces the array design method of a 500kW Photovoltaic power plant. Three types of the PV array are suggested. Also, string cables, sub-array cables and array cables are designed within 1% of voltage drop in the line, and the DC cable losses are analyzed. The results of this paper show that the DC cable loss of large-scale PV array can be reduced by adopting a proper sub-array design method.

Constitution and Operation of a Molten Carbonate Fuel Cell System (용융탄산염형 연료전지 발전시스템 구성 및 운전)

  • Ahn, Kyo-Sang;Kim, Dong-Hyung;Seol, Jin-Ho;Lim, Hee-Chun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.100-103
    • /
    • 1997
  • Korea Electric Power Corporation (KEPCO) started a fuel cell project to develop alternative sources of electric power because of the rapid increase in power demand and global environmental problems. For the development of a molten carbonate fuel cell (MCFC), KEPCO started the project in 1993 to develop a 2 kW MCFC system and finished it at the end of 1996. In this project, $ASPEN^+$ was utilized to design the 2 kW MCFC generation system. Based on this simulation, a power generation system was designed and installed for operation and a long term test of internally manifolded 2 kW class MCFC stack. This stack has 20 cells with an effective electrode area of $1000\;cm^2$. It was run at 0.84 V and $150\;mA/cm^2$ and was operated for more than 3,250 hours continuously. This paper describes the system configuration and its control and measurement units. An analysis of the stack performance, the effect of gas utilization ratio, and the stack performance requirements are also discussed.

  • PDF

Epidemic Disease Spreading Simulation Model Based on Census Data (센서스 데이터를 기반으로 만든 전염병 전파 시뮬레이션 모델)

  • Hwang, Kyosang;Lee, Taesik;Lee, Hyunrok
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.2
    • /
    • pp.163-171
    • /
    • 2014
  • Epidemic models are used to analyze the spreading of epidemic diseases, estimate public health needs, and assess the effectiveness of mitigation strategies. Modeling scope of an epidemic model ranges from the regional scale to national and global scale. Most of the epidemic models developed in Korea are at the national scale using the equation-based model. While these models are useful for designing and evaluating national public health policies, they do not provide sufficient details. As an alternative, individual-based models at the regional scale are often used to describe disease spreading, so that various mitigation strategies can be designed and tested. This paper presents an individual-based epidemic spreading model at regional scale. This model incorporates 2005 census data to build the synthetic population in the model representing Daejeon in 2005. The model's capability is demonstrated by an example where we assess the effectiveness of several mitigation strategies using the model.

System Development of a 100 kW Molten Carbonate Fuel Cell IV(System commisioning for operation (100 kW급 용융탄산염 연료전지 시스템 개발 IV(MCFC 시스템 시운전))

  • Lim, Hee-Chun;Ahn, Kyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1681-1683
    • /
    • 2005
  • The molten carbonate fuel tell(MCFC) is endowed with the high potential especially in future electric power generation industry by its own outstanding characteristics. KEPCO(KEPRI) started a 100 kW MCFC system development program in 1993 and has been executed 100kW system develpilot plant successfully completed first phaseopment by 2005 on the basis of successful results of 25kW system development. In this program, the components and mechanical structure for 100 kW stack and system construction were completed on last year and now system pre-commissioning was being executed. A 100 kW MCFC power plant was constructed at the site of Boryeong Thermal Power Plant. A 100 kW MCFC system has characterized as a high pressure operation mode, $CO_2$ recycle, and externally reforming power generation system. The 100 kW MCFC system consisted with stacks which was made by two 50 kW sub-stacks, 90 cells with 6,000 cm2 active area and BOP including a reformer, a recycle blower, a catalytic burner, an inverter, and etc. The system will be operated under 3 atm pressure condition and expected to last over 5,000 hours by the end of this year.

  • PDF

Treatment of Snakebite Wound in a Dog (개에서 발생한 독사 교상 치료 1례)

  • Park, Ji-Young;Lee, Jae-Yeon;Jee, Hyun-Chul;Park, Seong-Jun;Kim, Myung-Cheol;Jeong, Seong-Mok
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.449-452
    • /
    • 2007
  • A 2 year-old intact male Shih-tzu dog was presented with a history of snakebite on the left upper lip. He was depressed and had swelling, erythema and pain around the left muzzle. Both mandibular lymph nodes were swollen. Fang marks were not clear, but there were scratch wounds and prolonged bleeding. Hemogram revealed neither thrombocytopenia nor echinocytosis. Increased CK value in serum chemistry and myoglobinuria in urine analysis meant muscle injury. With careful monitoring, fluid, corticosteroid, antihistamine and antibiotics were administered. After the application of ice pack and suction, local symptoms changed for the worse. However, any other systemic disorders were not identified. After 5 days, the facial swelling had resolved completely.

Prognostic Predictors of Outcome in Patients with Snake Bite, Based on Initial Findings in the Emergency Department (독사 교상 환자의 응급실 초기 검사에 따른 예후 예측 인자)

  • Baek, In Yeop;Kim, Tae Kwon;Jin, Sang Chan;Cho, Woo Ik
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • Purpose: This study was conducted to identify predictors of serious poisoning in patients with snake bite based on initial findings. Methods: We conducted a retrospective study of patients with snake bite who were treated at the emergency department between January 2010 and December 2016. The patients were divided into two groups according to the severity of symptoms based on the traditional snakebite severity grading scale. The mild poisoning group (MP) was classified as those who had a grade I snakebite severity during the hospital stay, and the severe poisoning group (SP) was classified as patients who had grade I at the time of admission, but progressed to grade II-IV during hospitalization. Initial clinical manifestations and laboratory findings of the two groups were compared. Results: Bite to hospital time intervals of SP were longer than those of MP (p=0.034), and the local effect score (LES) was higher in SP (p<0.001). Laboratory analyses revealed that creatine phosphokinase (p=0.044), creatine phosphokinase MB isoenzyme (CK-MB, p=0.011) and serum amylase (p=0.008) were significantly higher in SP. LES, CK-MB and serum amylase were significant prognostic predictors as indicated by univariate logistic regression analysis. Multivariate analysis revealed the following two significant predictors: LES (odds ratio=3.983, p<0.001) and serum amylase (odds ratio=1.020, p=0.017). Conclusion: In managing cases of snake bites, clinical manifestations and laboratory findings must be carefully evaluated. LES and serum amylase are predictive factors for severe poisoning, which is especially important to rapid determination of the intensive care of the patient.

Isolation and Characterization of Morganella morganii from Asian Water Monitor Varanus salvator (아시아 물왕도마뱀에서 분리된 모가넬라 모가니의 분리동정)

  • Shin, Sang-Phil;Kim, Ji-Hyung;Gomez, Dennis K.;Choresca Jr., Casiano H.;Han, Jee-Eun;Park, Se-Chang
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.391-394
    • /
    • 2009
  • An Asian water monitor Varanus salvator with physical wound due to bite which was subsequently infected with bacterium resulting to hemorrhage and pus in the skin blisters, abdominal distention and septicemia. Morganella morganii was isolated and identified from the blood and kidney of the reptile, and confirmed by PCR and biochemical tests. The sensitivity of isolated strains to different groups of antibiotics was also evaluated using the disc diffusion method. Pathogenicity test using M. morganii (SNUFPC-MM01) (1.6 ${\times}$ $10^{11}$CFU/mouse) to suckling and adult mice resulted to the death of all mice. This paper describes the first isolation of M. morganii from Asian water monitor in Korea.

Aseismatic Performance Analysis of Circular RC Bridge Piers II. Suggestion for Transverse Steel Ratio (원형 철근콘크리트 교각의 내진성능 II. 심부구속철근비 제안)

  • Park Chang-Kyu;Lee Dae-Hyoung;Lee Beom-Gi;Chung Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.775-784
    • /
    • 2005
  • In this research, major design factors have been evaluated for the establishment of the rational seismic design code of circular RC(reinforced concrete) bridge pier Previous experimental researches have drawn a conclusion that transverse confinement reinforcements have been excessively used for RC bridge piers in Korea. Thus, the objective of this study is to propose a rational design equation for transverse reinforcements of RC bridge piers in Korea which would be classified as a low or moderate seismic region. Newly proposed equation further considers the effect of the axial force ratio and the longitudinal steel ratio. Minimum transverse confinement steel ratio is also proposed to avoid probable buckling of the longitudinal reinforcing steels subjected to relatively low axial force. It is thought that these new codes seem to alleviate the rebar congestion in the plastic hinge region of RC bridge piers which contribute to the enhancement of constructibility and economization for RC bridge construction.