• Title/Summary/Keyword: 광 주사 장치

Search Result 25, Processing Time 0.029 seconds

레이저 기입 광학계용 광학 장치의 계측

  • Korea Optical Industry Association
    • The Optical Journal
    • /
    • s.104
    • /
    • pp.59-69
    • /
    • 2006
  • 레이저 프린터나 디지털 복합기(MFP:MultiFunction Peripheral)에 탑재되는 레이저 기입 광 학계에는 주사 광학 소자(fθ렌즈, fθ미러)나 폴리곤 스캐너라는 광학 장치가 사용되고 있다. 본 고에서는 레이저 기입 광학계에 사용되는 광학 장치를 중심으로, 이들을 대상 으로 하는 최근의 계측 기술을 설명하면서 2020년을 향한 향후의 전망에 대하여 설명하 기로 한다.

  • PDF

Endoscopic Imaging and Fabrication of Micro-endoscope Catheter in Time-domain Optical Coherence Tomography (시간영역 광 간섭 단층촬영 시스템의 소형 엔도스코프 제작 및 영상구현)

  • Kim, Young-Kwan;Lee, Sung-Hun;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.206-213
    • /
    • 2010
  • We fabricated and characterized a compact endoscopic catheter for optical coherence tomography. The optical delay line (ODL), composed of a cylindrical piezoelectric transducer (PZT) and an optical fiber, was operated with a 1 kHz sinusoidal driving wave in the time-domain. When the ODL was driven with a sinusoidal wave function, the axial scanning speed was 6 m/s and the axial acquisition rate was 2000 line/s at a depth of about 3 mm. Endoscopic OCT images of a human finger and earhole were successfully obtained with an image rate of ten frames per second.

Development of Retina Photographing and Multi Channel Image Acquisition System for Thickness Measurement of Retina (망막 두께 측정을 위한 망막 촬영 및 다채널 영상획득장치 개발)

  • 양근호
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2004
  • In order to measure the retina thickness, the retina photographing system and the multi-channel high speed image data acquisition system is developed. This system requires the optical processing techniques and the high speed image processing techniques. The HeNe laser beam is projected the retina in artificial eye and then we sensed the reflected laser signal using APD array. The laser projection system on retina using optical instruments is implemented. In order to project the plane laser beam on retina, laser photographing system used the polygon mirror for horizontal scanning and the galvano mirror for vertical scanning. We acquired retina images in each channel of APD array, transferred computer using PCI interface the image data after real-time A/D converting.

  • PDF

Surface Measurement of Microstructures Using Optical Pick-up Based Scanner (광픽업 스캔 장치를 이용한 미소 구조물의 표면 측정)

  • Kim, Jae-Hyun;Park, Jung-Yul;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.73-76
    • /
    • 2010
  • The issue of inspection and characterization of microstructures has emerged as a major consideration in design, fabrication, and detection of MEMS devices. However, the conventional measurement techniques, including scanning electron microscopy (SEM) imaging, atomic force microscopy (AFM) scanning, and mechanical surface profiler, require often destructive process or may be difficult to measure with a wafer scale. In this paper, we characterize the surface profiles of microstructures using an optical scanner based on a DVD pick-up module. Scanning images of the microstructures are successfully generated using the intensity of reflected light from different depths of the surface profiles, based on the focus error signal (FES) from photodiodes. It is shown that the proposed optical scanner can be used as an alternative measurement system with high performance and low cost, compared to conventional measurement techniques.

The effects of fluoride releasing orthodontic sealants on the prevention and the progressive inhibition of enamel demiheralization in vitro (광중합형 및 자가중합형 교정용 전색제의 치아우식예방 및 진행억제효과에 관한 실험적 연구)

  • Chae, Seung-Won;Cho, Jae-O;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.979-995
    • /
    • 1997
  • The purpose of this study was to identify the preventive and the progressive inhibitory effects of enamel demineralization with fluoride releasing light-and self-cured orthodontic sealants(FluoroBond), in vitro, under the polarizing light microscope and the scanning electon microscope. The polarizing light microscopic group was subdivided into seven groups(Group A-Group G). The scanning electron microscopic group was also subdivided into seven groups(Group A'-Goup G'). For polarizing light microscopic evaluation, longitudinal sections were made longitudinally by Maruto cutter(Maruto Co., Japan) and Maruto grinding machine(Maruto Co., Japan). Sections were examined and photographed by the polarizing light microscope(Olympus Optical Co., Japan) using crossed polars and with the enamel rod longitudinal axis oriented at $45^{\circ}$ to the extinction position. For scanning electron microscopic evaluation, the specimens were coated with a highly conducting layer of gold palladium in a model Hus-4 high-vacuum evaporator and examined in an ISI-100B scanning electron microcope operated at 20kV. The results of this study were as follows : 1. The mean depths of artificial carious lesions under a polarized light microscope were $Group\;A(5.08{\mu}m),\;Group\;B(47.82{\mu}m,\;Group\;C(8.42{\mu}m),\;Group\;D(7.20{\mu}m),\;Group\;E(85.41{\mu}m),\;Group\;F(60.38{\mu}m),\;Group\;G(60.13{\mu}m)$. 2. There were statistically significant differences in Group B compared with Group A, C, and D(p<0.05), and also, in Group I compared with Group F and Group G(p<0.05). 3. Light-and self-cured orthodontic sealants had the preventive effects of enamel demineralization. 4. Light-and self-cured orthodontic sealants had the progressive inhibitory effects of enamel demineralization. 5. The time progress of demineralizing agent had no influence on the samples of light-and self-cured orthodontic sealants under the scanning electron microscope. 6. There was no difference between the specimens of light-and self-cured orthodontic sealants both in the polarized light microscopic group and in the scanning electron microscopic group.

  • PDF

Construction of an Optically Pumped Cesium Atomic Clock (광펌핑 세슘원자시계의 구성)

  • 이호성;오차환;양성훈
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.123-132
    • /
    • 1992
  • We designed and constructed the Cs beam tube which consists of a Ramsey cavity, four C-field rods, fluorescence detecting systems, and etc. for developing an optically pumped Cs atomic clock. A semiconductor laser was used for optical pumping and probing in the Cs beam. We observed Ramsey resonance signal by detecting the fluorescence signal in the probing region as the microwave frequency injected into the Ramsey cavity was scanned near 9192.6 MHz which corresponds to the "clock transition" of Cs atoms. We found that the linewidth of the Ramsey signal was 200 Hz, the magnetic field intensity was $8.61\muT$ when the current of 0.8A flowed in the C-field rods, and the second order Zeeman shift by the magnetic field was 3.17 Hz.s 3.17 Hz.

  • PDF

Qualitative Noise Characteristics of Rotating Polygonal Disk Applied to Digital Printer Systems (디지털 프린터에 적용되는 회전 다각형 디스크의 소음특성)

  • Jo, Jun-Hyeon;Kim, Hyeong-Chae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1425-1429
    • /
    • 2007
  • Consumer's product selection measures are being shifted from the units' operational performance to overall performance. Low noise, low vibration, and low power consumption rate, etc. which used to be additional quality indices, now become vital performance factors. Especially, noise and vibration characteristics are being considered as equivalent to/or even more critical than operational performance in certain products such as office machines and home entertainment systems, which share the same space with human being's daily life. Therefore, noise reduction and sound quality improvement technology becomes an inevitable design issue for those applications. Qualitative noise characteristics of rotating polygonal disk applied to digital printer systems are presented. Overall sound pressure level change and tonal noise variation with respect to the geometrical properties of polygonal disk, operational speed, and others are briefly discussed based on experimental results.

  • PDF

Qualitative Noise Characteristics of Rotating Polygonal Disk Applied to Digital Printer Systems (디지털 프린터에 적용되는 회전 다각형 디스크의 소음특성)

  • Jo, Jun-Hyeon;Kim, Hyeong-Chae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.606-611
    • /
    • 2008
  • Consumer's product selection measures are being shifted from the units' operational performance to overall performance. Low noise, low vibration, and low power consumption rate, etc. which used to be additional quality indices, now become vital performance factors. Especially, noise and vibration characteristics are being considered as equivalent to/or even more critical than operational performance in certain products such as office machines and home entertainment systems, which share the same space with human being's daily life. Therefore, noise reduction and sound quality improvement technology becomes an inevitable design issue for those applications. Qualitative noise characteristics of rotating polygonal disk applied to digital printer systems are presented. Overall sound pressure level change and tonal noise variation with respect to the geometrical properties of polygonal disk, operational speed, and others are briefly discussed based on experimental results.