• Title/Summary/Keyword: 광치료

Search Result 249, Processing Time 0.029 seconds

Effect of a Water Soluble Dimethyl Dimethoxy Biphenylate Derivative on the Carbon Tetrachloride Induced Hepatotoxicity in Rats (수용성 Dimethyl Dimethoxy Biphenylate 유도체의 간염 치료 효과)

  • Moon, Jeon-Ok;Cheung, Kyeung-Ook;Kim, Su-Hyun;Kim, Nam-Duk;Lee, Sung-Kwang;Yang, Hee-Sun;Lee, Chi-Ho
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.3
    • /
    • pp.173-179
    • /
    • 1997
  • A water-soluble DDB derivative (Bis{2-(methylamino)ethyl}-4,4-dimethoxy-5,5',6,6'-dimethylenedioxy-biphenyl-2,2'-dicarboxylate, DDB-S) was synthesized and its therapeutic effects on the liver damage induced by carbon tetrachloride in rats were evaluated. Oral administration of DDB-S reduced the aspartate aminotransferase(AST) and alanine aminotransferase(ALT) activities and increased total protein and albumin contents in the serum of the carbon tetrachloride intoxicated rat. Therapeutic effects of DDB-S by intravenous injection was also investigated using carbon tetrachloride intoxicated rats. Histological studies showed that IV injection of DDB-S had improved the typical necrosis around centrilobular area in liver tissue due to the carbon tetrachloride intoxication and also prevented the elevation of liver weigh/body weight ratio. IV administration of DDB-S to $CCl_4-treated$ rats significantly decreased AST & ALT activities and also prevented the decrease of aniline hydroxylation activity of the liver. These results indicate that i.v. administration of DDB-S is very effective in recovering the liver function in $CCl_4-treated$ rats.

  • PDF

Anti-mutagenic and Anti-septic Effects of $\beta$-glucan from Aureobasidium pullulans SM-2001 (흑효모유래 $\beta$-glucan의 패혈증 치료효과 및 항돌연변이 활성 평가)

  • Ku, Sae-Kwang
    • Korean Journal of Oriental Medicine
    • /
    • v.15 no.3
    • /
    • pp.75-82
    • /
    • 2009
  • Anti-mutagenic and anti-septic effects of $\beta$-1,3/1,6-glucan from Aureobasidium pullulans SM-2001 were evaluated on the on the cyclophosphamide (CPA)-cecal ligation puncture (CLP) and CPA-treated mice. To induce immunosuppression and mutagenicity, 150 and 110 mg/kg of CPA were single intraperitoneally injected at 3 or 1 day before CLP or initial $\beta$-glucan administration. In CLP animals, the cecum was mobilized and ligated below the ileocecal valve, punctured through both surfaces twice with a 22-gauge needle. 125 mg/kg of $\beta$-glucan were dissolved in saline and subcutaneously or orally administered in a volume of 10 ml/kg (of body weight), 4 times, 12 hrs intervals from 6 hrs after CLP or 1 day after second dose of CPA. After treatment of $\beta$-glucan, the mortalities were observed in CPA-CLP model, and the appearance of a micronucleus is used as an index for genotoxic potential in CPA model. As results of CPA-CLP sepsis, all animals (9/9, 100%) in CPA-CLP control were dead within 2 days after CLP. In addition, increase of the number of bone marrow MNPCEs indicated mutagenicity were also observed by treatment of CPA. However, $\beta$-glucan treatment effectively inhibited the mortalities in CPA-CLP, and it also reduced the CPA treatment-related mutagenicity, respectively. These results indicated that $\beta$-glucan has effective anti-septic and anti-mutagenic effects and can be used as an agents for treating sepsis and mutagenicity related to high-dose chemotherapy or radiotherapy. However, further studies should be conducted to observe more detail action mechanisms of it's anti-septic and anti-mutagenic effects.

  • PDF

Fabrication of Miniature Radiation Sensor Using Plastic Optical Fiber for Medical Usage (플라스틱 광섬유를 이용한 초소형 의료용 방사선 센서 제작)

  • Hwang, Young-Muk;Cho, Dong-Hyun;Cho, Hyo-Sung;Kim, Sin;Lee, Bong-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.9-12
    • /
    • 2005
  • In this study, film type radiation sensor tips are fabricated for remote sensing of X or g-ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by X and g-ray is guided by the plastic optical fiber and is measured by optical detector and power-meter. It is expected that the fiber-optic radiation sensor which is possible to be developed based on this study is used for remote, fast and exact sensing of X or g-ray because of its characteristics such as very small size, light weight and no interference to electromagnetic fields.

  • PDF

Cell differentiation control device capable of simultaneous stimulation of multi-wavelength LED (다파장 LED의 동시 자극 인가가 가능한 세포 분화 유도기)

  • Choe, Se-woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.2
    • /
    • pp.221-227
    • /
    • 2021
  • Recently, interests in mask-type skin care devices using light-emitting diodes have been increasing and optical stimuli at certain wavelengths have been known to have various therapeutic effects, such as skin whitening, acne treatment, elasticity and wrinkle improvement by controlling the exposure to wavelengths of light and irradiation time. In particular, light sources of different wavelengths are applied in masks for the purpose of suppressing skin aging, inducing cell proliferation, and alleviating skin inflammation. In this paper, we developed a light-emitting diode control system that is actively used in skin regeneration masks using a microcontroller. Optical stimuli with different manners were applied to skin fibroblast cells in a single or complex wavelengths, and then confirmed how they are effective in the cell differentiation. In addition, we found a specific wavelength that has a positive effect on cell proliferation rates, and confirm the effectiveness of cell proliferation by image processing based quantitative analysis.

Investigation of Scatter and Septal Penetration in I-131 Imaging Using GATE Simulation (GATE 시뮬레이션을 이용한 I-131 영상의 산란 및 격벽통과 보정방법 연구)

  • Jung, Ji-Young;Kim, Hee-Joung;Yu, A-Ram;Cho, Hyo-Min;Lee, Chang-Lae;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.72-79
    • /
    • 2009
  • Scatter correction for I-131 plays a very important role to improve image quality and quantitation. I-131 has multiple and higher energy gamma-ray emissions. Image quality and quantitative accuracy in I-131 imaging are degraded by object scatter as well as scatter and septal penetration in the collimator. The purpose of this study was to estimate scatter and septal penetration and investigate two scatter correction methods using Monte Carlo simulation. The gamma camera system simulated in this study was a FORTE system (Phillips, Nederland) with high energy, general-purpose, parallel hole collimator. We simulated for two types of high energy collimators. One is composed of lead, and the other is composed of artificially high Z number and high density. We simulated energy spectrum using a point source in air. We estimated both full width at half maximum (FWHM) and full width at tenth maximum (FWTM) using line spread function (LSF) in cylindrical water phantom. We applied two scatter correction methods, triple energy window scatter correction (TEW) and extended triple energy window scatter correction (ETEW). The TEW method is a pixel-by pixel based correction which is easy to implement clinically. The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejection window, which can overestimate or the underestimate scatter. The both FWHM and FWTM were estimated as 41.2 mm and 206.5 mm for lead collimator, respectively. The FWHM and FWTM were estimated as 27.3 mm and 45.6 mm for artificially high Z and high density collimator, respectively. ETEW showed that the estimation of scatter components was close to the true scatter components. In conclusion, correction for septal penetration and scatter is important to improve image quality and quantitative accuracy in I-131 imaging. The ETEW method in scatter correction appeared to be useful in I-131 imaging.

  • PDF

Effect of N-Acetylcysteine on the Supetoxide Release, Chemotaxis from the Neutrophils and Glutathione Level of Plasma and Neutrophils (N-Acetylcysteine이 호중구의 Superoxide, Chemotaxis 및 혈장과 호중구의 Glutathione에 미치는 영향)

  • Song, Jeong-Sup;Lee, Sook-Young;Moon, Hwa-Sik;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.475-483
    • /
    • 1994
  • Background: N-acetylcysteine(ACE) is used both orally and intravenously in a variety of experimental pathologies resembling human disease states which exhibit endothelial toxicity as a result of oxidative stress, including acute pulmonary oxygen toxicity, septicemia and endotoxin shock. Despite these observations in vivo, it is not certain how this thiol drug produces its protective effects. ACE is a cysteine derivative which is able to direct1y react with oxygen radicals and may also act as a cysteine and glutathione(GSH) precursor following deacetylation. In this paper, we tried to know whether the therapeutic doses of ACE can modify the inflammatory function of the neutrophils and can increase the glutathione level of plasma in chronic obstructive pulmonary disease(COPD) patients. In addition, the effect of ACE to the purified neutrophil in terms of superoxide release and glutathione synthesis were observed. Method: Firstly, we gave 600mg of ACE for seven days and compare the release of superoxide, luminol-enhanced chemiluminescence from the neutrophils, neutrophil chemotaxis, and plasma GSH levels before and after ACE treatment in COPD patients. Secondly, we observed the dose dependent effect of ACE to the purified neutrophil's superoxide release and GSH levels in vitro. Results: 1) Usual oral therapeutic doses(600mg per day) of ACE for seven days did affect neither on the neutrophil's superoxide release, chemiluminescence, chemotaxis, nor on the plasma GSH concentration in the COPD patients. 2) ACE decreases the purified neutrophil's superoxide release and increase the GSH production in dose dependent fashion in vitro. Conclusion: Despite the fact that oral ACE treatment did not affect on the neutrophil's inflammatory function and plasma GSH concentration in COPD patients in usual therapeutic doses, it decreases the superoxide release and increases the GSH production from the isolated neutrophils in high molar concentrations. These findings suggest that to obtain an antioxidative effects of ACE, it might be needed to increase the daily dosage of ACE or therapeutic duration or change the route of adminisration in COPD patients.

  • PDF

Increased Catalase Activity by All-trans Retinoic Acid and Its Effect on Radiosensitivity in Rat Glioma Cells (백서 교종 세포에서 레티노인산에 의한 카탈라제의 활성 증가가 방사선감수성에 미치는 효과)

  • Jin, Hua;Jeon, Ha-Yeun;Kim, Won-Dong;Ahn, Hee-Yul;Yu, Jae-Ran;Park, Woo-Yoon
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.211-216
    • /
    • 2005
  • Purpose: It has been reported that all-trans retinoic acid (ATRA) can inhibit glioma growing in vitro. However, clinical trials with ATRA alone in gliomas revealed modest results. ATRA has been shown to increase radiosensitivity in other tumor types, so combining radiation and ATRA would be one of alternatives to increase therapeutic efficacy in malignant gliomas. Thus, we intended to know the role of catalase, which is induced by ATRA, for radiosensitivity if radiation-reduced reactive oxygen species (ROS) is removed by catalase, the effect of radiation will be reduced. Materials and Methods: A rat glioma cell line (36B10) was used for this study. The change of catalase activity and radiosensitivity by ATRA, with or without 3-amino-1, 2, 4-triazole (ATZ), a chemical inhibitor of catalase were measured. Catalase activity was measured by the decomposition of $H_2O_2$ spectrophotometrically Radiosensitivity was measured with clonogenic assay. Also ROS was measured using a 2, 7-dichlorofluorescein diacetate spectrophotometrically. Results: When 36B10 cells were exposed to 10, 25 and $50{\mu}M$ of ATRA for 48 h, the expression of catalase activity were increased with increasing concentration and incubation time of ATRA. Catalase activity was decreased with increasing the concentration of AT (1, $10{\mu}M$) dose-dependently. ROS was increased with ATRA and it was augmented with the combination of ATRA and radiation. ATZ decreased ROS production and increased cell survival in combination of ATRA and radiation despite the reduction of catalase. Conclusion: The increase of ROS is one of the reasons for the increased radiosensitivity in combination with ATRA. The catalase that is induced by ATRA doesn't decrease ROS production and radiosensitivity.

Prognostic Value of the Expression of p53 and bcl-2 in Non-Small Cell Lung Cancer (비소세포폐암에서 p53과 bcl-2의 발현이 예후에 미치는 영향)

  • Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Keum, Joo-Seob;Kong, Gu;Lee, Jung-Dal
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.962-974
    • /
    • 1998
  • Background: Alteration of p53 tumor suppressor genes is most frequently identified in human neoplasms, including lung carcinoma. It is well known that bcl-2 oncoprotein protects cells from apoptosis. Recent studies have demonstrated that bcl-2 expression is associated with favorable prognosis for patients with non-small cell lung carcinoma. However, the precise biologic role of bcl-2 in the development of these tumors is still obscure. p53 and bcl-2 have important regulatory influence in the apoptotic pathway and thus their relationship is of interest in tumorigenesis, especially lung cancer. Purpose: The author investigated to know the prognostic significance of the expression of p53 and bcl-2 in radically resected non-small cell lung cancer. Method: 84 cases of formalin-fixed paraffin-embedded blocks from resected primary non-small cell lung cancer from 1980 to 1994 at Hanyang University Hospital were available for both clinical follow-up and immunohistochemical staining using monoclonal antibodies for p53 and bcl-2. Results : The histologic classification of the tumor was based on WHO criteria., and the specimens included 45 squamous cell carcinomas(53.6%), 28 adeonocarcinomas(33.3%) and 11 large cell carcinomas(13.1 %). p53 immunoreactivity was noted in 47 cases of 84 cases(56.0%). bcl-2 immunoreactivity was noted in 15 cases of 84 cases(17.9%). The mean survival duration was $64.23{\pm}10.73$ months in bcl-2 positive group and $35.28{\pm}4$. 39 months in bcl-2 negative group. The bcl-2 expression was significantly correlated with survival in radically resected non-small cell lung cancer patients(p=0.03). The mean survival duration was $34.71{\pm}6.12$ months in p53 positive group and $45.35{\pm}6.30$ months in p53 negative group(p=0.21). The p53 expression was not predictive for survival. There was no correlation between combination of the different status of p53 and bcl-2 expression in our study. Conclusions : The interaction and the regulation of new biologic markers, such as those involved in the apoptotic pathway, are complex. bcl-2 overexpression is a good prognostic factor in non-small cell lung cancer and p53 expression is not significantly associated with the prognostic factor in non-small cell lung cancer.

  • PDF

A PHOTOELASTIC STUDY ON THE STRESS DISTRIBUTION OF THE UPPER ANTERIOR TEETH WHEN RETRACT WITH HIGH PULL J-HOOK HEADGEAR (상악전치의 후방견인시 J-hook headgear의 사용이 응력분포변화에 미치는 영향에 대한 광탄성학적 연구)

  • Lee, You-Jin;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.697-709
    • /
    • 1997
  • This study was designed to investigate the stress intensity and distribution produced by 1mm activation of retraction archwire with $0^{\circ},\;7^{\circ},\;14^{\circ}$ torque and application of high polk J-hook headgear during retraction of four maxillary incisors using the photoelastic stress analysis. The photoelastic model was made with a PL-3 type epoxy resin which was substituted by alveolar bone portion. Each retraction archwire was fabricated from .020' X .025' stainless steel wire which had vertical loops in 7mm height and hooks for high pull J-hook headgear between central and lateral incisors. The high pull J-hook headgear was applied 35 degree backward and upward to occlusal plane with 200gm pet each side The findings of this study were as follows: 1. In case of $0^{\circ}$ torque, the stress was distributed from cervical 1/8 to apex of roots of central and lateral incisors which were the forms of arc mode. When the high pull J-hook headgear was applied, the stress distributed by arc mode was presented from cervical 1/2 to apex of roots of central and lateral incisors. And the stress distributed by following the root surface was presented from alveolar crest to cervical 1/2 of roots of central and lateral incisors. The stress between apecies of central and Lateral incisors was presented also. 2. In case of $7^{\circ}$ torque, the stress distributed by arc mode was presented from cervical 1/2 to apex of roots of central and lateral incisors. And the stress distributed by following the root surface was presented from alveolar crest to cervical 1/2 of roots of central and lateral incisors. When the high pull J-hook headgear was applied, the stress distributed by following the root surface was presented mote apically than without headgear. The stress between apecies of central and lateral incisors was presented also. 3. In case of $14^{\circ}$ torque, the stress distributed by following the root surface was Presented from alveolar crest to apex of roots of central and lateral incisors. When the high pull J-hook headgear was applied, the stress distributed by following the root surface was presented stronger than without headgear The stress between apecies of central and lateral incisors was presented also.

  • PDF

THE TEMPERATURE RISING IN PULP CHAMBER DURING COMPOSITE RESIN POLYMERIZATION (광중합 기전에 따른 복합레진 중합 시 치수강 내 온도변화)

  • Hwang, Dong-Hwan;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.431-438
    • /
    • 2003
  • This study investigates pulp chamber temperature rise during composite resin polymerization by plasma arc(Group III : Flipo 3 sec, Group IV : Flipo 5 sec) and LED curing units(Group V : Lux-O-Max, 40 sec) as well as conventional halogen lamp curing units(Group I : VIP mode3, 20 sec, Group II : VIP mode6, 20 sec). The results are as follows : 1. All of the investigated pulp chamber temperature rises are lower than the boundary temperature could result in irreversible damage to the pulpal tissue ($5.5^{\circ}C$). 2. In the group II, it is found the significantly higher pulp chamber temperature rise than any other groups(p<0.05). 3. In the group of composite resin light-cured with VIP, it is found the significantly higher pulp chamber temperature rise in the group II than group I(p<0.05). 4. In the group of composite resin light-cured with Flipo, it is found the significantly higher pulp chamber temperature rise in the group IV than group III (p<0.05). 5. In the case of comparing VIP and Flipo, group II is significantly higher pulp chamber temperature rise than group III, IV(p<0.05), and group IV is significantly higher pulp chamber temperature rise than group I(p<0.05), and it does not significantly differ between group I and III. 6. In the group of composite resin light-cured with Lux-O-Max, it is found the significantly lower pulp chamber temperature rise than any other groups (p<0.05).

  • PDF