• Title/Summary/Keyword: 광응답

Search Result 303, Processing Time 0.531 seconds

Relationship between Transverse-Mode Behavior and Dynamic Characteristics in Multi-Mode VCSELs (다중모드 VCSEL의 모드 특성과 동특성 사이의 관계)

  • Kim Bong-Seok;Kim Sang-Bae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.19-26
    • /
    • 2005
  • We have studied the relationship between static mode behavior and dynamic characteristics of multiple transverse-mode VCSELs by measuring the modal L-I and I-V characteristics. Dependence of the resonance frequencies of RIN (relative intensity noise) spectra on the injection current can be understood by modal L-I characteristics and mode-coupling effects. Each transverse mode behaves as an independent diode laser with the different threshold current in large active-area VCSELs, and the multiple-step turn-on is observed when step-current input is applied. This multiple-step turn-on is a result of different turn-on delay times of the transverse modes. Since the multiple-step turn-on increases the rise-time significantly, the wide active-area VCSELs are not suitable for high-speed optical transmitters unless the input current is adjusted for single transverse-mode operation.

Contrallable P-type method for WSe2 using Octadecyltrichlorosilane (OTS) (Octadecyltrichlorosilane (OTS)을 사용한 WSe2의 농도조절이 가능한 P형 도핑 방법)

  • Kim, Jin-Ok;Gang, Dong-Ho;Park, Jin-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.193.2-193.2
    • /
    • 2015
  • 최근 3차원 반도체의 물질적인 한계를 극복하기 위해 2차원 전이금속 칼코게나이드(TMD)에 대한 연구가 활발히 진행되고 있다. 하지만 TMD 물질의 도핑 방법에 대한 수많은 연구에도 불구하고 대부분이 n채널 물질인 MoS2에 대한 것에 국한되어 있다. 게다가 이전의 TMD 도핑 기술 연구 결과는 채널이 도체화 될 정도의 매우 높은 농도의 도핑 현상만을 보여주었다. 이 연구에서 우리는 WSe2로 만든 p형 채널 트랜지스터에서 Octaecyltrichlorosilane(OTS)층의 농도 조절로 제어가 가능한 약한 농도의 p형 도핑기술을 보여준다. 이 p형 도핑 현상은 OTS의 메틸기(-CH3)그룹에 의한 양성 쌍극자모멘트가 WSe2내의 전자 농도를 낮추는데서 기인한다. 제어가 가능한 p형 도핑은 $2.1{\times}10^{11}cm^{-2}$ 사이에서 $5.2{\times}10^{11}cm^{-2}$로 degenerate되지 않은 정도로 WSe2 기반의 광, 전기적인 소자에서 적절한 농도로 최적화 될 수 있다. (도핑 정도에 따른 문턱전압 상승, 전류 on/off율 상승, 전계효과 이동도 상승, 광응답성 하락, 광검출성 하락) 또한 OTS에서 비롯한 p도핑 효과는 대기중에서 오랜시간이 지나도 작은 성능 변화만을 보여주며(60시간 후 18~34% 문턱전압 감소변화량) $120^{\circ}C$의 열처리를 통하여 저하된 성능이 거의 완벽하게 회복된다. 이 연구는 Raman 분광법과 전기적, 광학적 측정을 통하여 분석되었으며 OTS 도핑현상이 WSe2 박막의 두께와 무관함 또한 확인했다.

  • PDF

A Study on the Reception Sensitivity of the Optical Receiver with the Order Change of the Optical Filter in Optical Preamplifier System (광 전치 증폭시스템에서 광필터의 차수변화에 따른 광수신기의 수신감도에 관한 연구)

  • Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.218-223
    • /
    • 2016
  • This study examined the order of the Butterworth filter for the correlation on the sensitivity of the receiver in the receiver of an optical system. In the general case, the sensitivity of the receiver is increased if the order of the filter was increased more. This is because increasing the order of the filter response of the normalized frequency of the filter is similar to the rectangular wave. For that reason, the method used to increase the order of the filter increases the sensitivity of the receiver. On the other hand, a method of increasing the order of the filter and makes the system complicated increases the cost of the system. This study examined the correlation between the order of the sensitivity of the receiver filter and to configure the system by simply looking for ways to reduce the cost of the system. The simulation results showed that increasing the order of the filter resulted in a receiver that can determine if the sensitivity is raised. In addition, the order of the Butterworth filter range that does not reduce the sensitivity of the receiver was 2. Therefore, it will be possible to implement an inexpensive optical system of the receiver using the data from this study.

A Novel Luminance Adaptation Effect Model in Pixel Intensity Domain for Image Quality Assessment: Theory and Application (영상 화질 측정을 위한 픽셀 강도 영역의 새로운 광적응 효과 모델: 이론 및 적용)

  • Bae, Sung-Ho;Kim, Munchurl
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2015.07a
    • /
    • pp.78-80
    • /
    • 2015
  • 광적응(Luminance Adaptation; LA) 효과는 영상의 배경 밝기에 따른 왜곡에 대한 시각 인지 민감도가 달라지는 특성을 의미한다. 기존 영상 화질 측정(Image Quality Assessment; IQA) 방법들은 베버의 법칙(Weber' s law) 모델을 이용하여 LA 효과를 IQA 방법에 반영해왔다. 그러나, 이러한 IQA 방법들에 있어서 베버의 법칙 기반 LA 효과 모델은 다음 두 가지 이유로 부정확하게 동작한다: (i) 전통적인 베버의 법칙 모델은 실제 광도(luminance)에 대한 인지 민감도 응답값을 정확히 반영할 수 없다는 것이 밝혀졌다, (ii) 대부분 IQA 방법들은 픽셀 강도 영역에서 계산되지만, 베버의 법칙과 같은 LA 효과 모델들은 광도 영역에서 개발되었다. 따라서 광도와 픽셀 강도간 비선형 관계로 인해 IQA 방법에 반영된 베버의 법칙 기반 LA 효과 모델들은 부정확하게 동작한다. 이 문제를 해결하기 위해, 본 논문에서 처음으로 픽셀 강도 영역에서의 LA 모델을 이론적으로 유도한다. 본 논문에서 제안하는 픽셀 강도 영역에서의 LA 효과 모델은 감마 교정 함수(Gamma correction function)와 광도 영역에서의 LA 효과 모델인 제곱-법칙(power-law) 모델을 기반으로 하는 테일러 급수 확장 근사화를 통해 유도된다. 제안하는 픽셀 강도 영역 LA 효과 모델의 효과를 검증하기 위해, 제안하는 LA 효과 모델을 PSNR 에 도입하여 광범위한 실험을 수행한다. 실험 결과, 제안하는 LA 효과 모델 기반 PSNR 은 PSNR 및 베버의 법칙 기반 PSNR 대비 괄목할 만한 주관적 화질 예측 성능 향상을 보였다.

  • PDF

A study on the transmittance-controlled liquid crystal cell (광 투과도 제어형 액정 셀 연구)

  • Yang, Seong-Soo;Kim, Phil-Jung;Oh, Byeong-Yun
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1224-1229
    • /
    • 2019
  • In this study, a liquid crystal (LC) cell was manufactured for smart window applications, such as blinds, and a system for controlling the light transmission rate was developed. The threshold voltage of the LC cell was 1.325 V and when the transmission rate was 10%, the voltage showed 2.370 V, indicating that the LC cell manufactured is driven at low voltage. The LC cell also operated reliably after being heated for 10 min at 80℃. with a response time of less than 30ms. The operation system designed the applied voltage of the LC cell with a interval of about 0.5 V from 0.15 V to 3.53 V and confirmed that the light transmission rate of the LC varies depending on the actual applied voltage. These results suggest that LC cells are likely to be smart window applications.

Geometrical Analysis and Implementation of the Real-Time Tuning Structure Using Spatial Light Modulator in Photorefractive Tunable Filter (광굴절 가변 필터에서 공간광학변조기를 이용한 실시간 튜닝 구조의 기하학적 해석 및 구현)

  • An, Jun-Won;Kim, Seong-Goo;Kim, Nam
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.12
    • /
    • pp.43-52
    • /
    • 1999
  • We propose a new method for tuning of center wavelength in photorefractive filter using $LiNbO_3$ crystal doped with 0.015Wt.% Fe. through the filter bandwidth property analysis using the geometrical method, a new wavelength selectivity theory was presented. In this scheme, the tuning of the center wavelength can be achieved by the real time incident angle control of the received heam, which was gotten by the spatial light modulator. So, tuning time depend on the response time of the SLM and results in the high speed turing. Because the use of thermally fixed grating in our filter, it has uniform diffraction property to the all filtering wavelength. Designed tunable filter has 4nm bandwidth and composed of the three channel with 10nm space. From the optical experiment, we get the 4.5nm, 4.25nm, 4nm bandwidth and 1530.5nm, 1540.5nm, 1549.5nm center wavelength respectively.

  • PDF

Photonic-Crystal-Based Thin Film Sensor for Detecting Volatile Organic Compounds (광결정 기반의 휘발성 유기 화합물 검지 박막 센서)

  • Chang, Hyung-Kwan;Park, Jungyul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.149-155
    • /
    • 2016
  • Early detection of toxic gases, such as volatile organic compounds (VOCs), is important for safety and environmental protection. However, the conventional detection methods require long-term measurement times and expensive equipment. In this study, we propose a thin-film-type chemical sensor for VOCs, which consists of self-assembled monosize nanoparticles for 3-D photonic crystal structures and polydimthylsiloxane (PDMS) film. It is operated without any external power source, is truly portable, and has a fast response time. The structure color of the sensor changes when it is exposed to VOCs, because VOCs induce a swelling of the PDMS. Therefore, using this principle of color change, we can create a thin-film sensor for immediate detection of various types of VOCs. The proposed device evidences that a fast response time of just seconds, along with a clear color change, are successfully observed when the sensor is exposed to gas-phase VOCs.

Performance Improvement for Visible Light Communications Using Pre-Equalizer and Optical Design (전치 등화기와 광학설계를 이용한 가시광통신 전송 용량 및 거리 향상 연구)

  • Kwon, Do-Hoon;Yang, Se-Hoon;Kim, Hyun-Seung;Son, Yong-Hwan;Han, Sang-Kook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.6
    • /
    • pp.476-481
    • /
    • 2014
  • In this paper, we design the pre-equalizer of transmitter circuit in order to enhancement modulation bandwidth of white LED which is light source of VLC (Visible Light Communication). Also, we eliminate yellow light component by optical filtering which mitigate frequency response of white LED. Power loss by optical filtering is overcome by using convex lens. By applying proposed system, 3 dB bandwidth deciding modulation bandwidth of white LED increases from 3 MHz to more than 25 MHz and the transmission distance increases by optical design which secure additional signal power. We optically modulate NRZ-OOK signal to LED and receive light signal using APD. We analyze received data using CSA and RFSA. As a result, we experimently demonstrate the possibility that transmits NRZ-OOK signal up to 30 Mbps in 4.5 m, 50 Mbps in 1.5 m through the pre-equalizer and optical design.

Development of Radiation Detector with Intensifying Screen (증감지를 이용한 방사선검출기 개발)

  • Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.859-863
    • /
    • 2023
  • In this study, simple and portable radiation detection system using X-ray intensifying screen, optical sensor and micro-controller unit for education was proposed. The system was simply composed of detection unit consisting of an optical sensor and intensifying screen, micro-controller unit, and was designed to be suitable for portable. Radiation was measured using developed detection system and absorbed dose dosimeter with changing tube voltage from 50 to 100 kVp. The tube current and SDD were fixed on 100 mAs and 100 cm, and dose were measured repeated ten times at each tube voltage. The response and linearity of the detection system were confirmed using the measured values. It was confirmed that the comparison measurement results of the detection system and absorbed dose dosimeter showed a high correlation(r : 0.998, p<.001). In this results, the feasibility of the detection system with intensifying screen and micro-controller unit based was confirmed, and we considered that the developed detection system could be applied to portable, compact, low cost system for education.

Flavor and taste characteristic of black pepper by different nonthermal sterilization methods (비가열 살균 후추의 향미특성)

  • Lee, Gwang Min;Shin, Jung Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.551-557
    • /
    • 2019
  • The purpose of this study was to investigate the changes of flavor and taste characteristics of black pepper treated with three different nonthermal sterilization methods, which are intense pulsed light (IPL), ultraviolet (UV), and cold plasma (CP). Also, the sensorial and instrumental evaluation of black pepper before and after nonthermal treatments were analyzed. As a result of color value, UV and CP treatments did not show chromacity difference (ΔE), but IPL treatment showed a significant difference of 6.58. Piperine contents of sample before nonthermal treatments was 10.7±0.53 mg/g and the piperine contents of all samples decreased after nonthermal treatments. The result of the electronic nose analysis were divided into two groups before and after nonthermal treatments, and divided into three group by principle component analysis. According to the intensity test, after nonthermal treatments, all sample had low flavor and taste, and the intensity was in the order of IPL, CP, and UV. In thirteen sensory attribute languages developed through quantitiative descriptive analysis (QDA), the intensity value of the samples were low after nonthermal treatments.