• Title/Summary/Keyword: 광원제어기

Search Result 60, Processing Time 0.027 seconds

Growth Model of Common Ice Plant (Mesembryanthemum crystallinum L.) Using Expolinear Functions in a Closed-type Plant Production System (완전제어형 식물 생산 시스템에서 선형 지수 함수를 이용한 Common Ice Plant의 생육 모델)

  • Cha, Mi-Kyung;Kim, Ju-Sung;Cho, Young-Yeol
    • Horticultural Science & Technology
    • /
    • v.32 no.4
    • /
    • pp.493-498
    • /
    • 2014
  • The objective of this study was to make growth and yield models for common ice plant (Mesembryanthemum crystallinum L.) using expolinear functional equations in a closed-type plant production system. Three-band radiation type fluorescent lamps with a 12-hours photoperiod were used, and the light intensity was $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Nutrient film systems with three layers were used for plant growth. Environmental conditions, such as air temperature, relative humidity and $CO_2$ concentration were controlled by an ON/OFF operation. Leaf area, shoot fresh and dry weights, light use efficiency of common ice plant as function of days after transplanting, accumulative temperature and accumulative radiation were analyzed. Leaf area, shoot fresh and dry weights per area were described using an expolinear equation. A linear relationship between shoot dry and fresh weights was observed. Light use efficiency of common ice plant was $3.3g{\cdot}MJ^{-1}$ at 30 days after transplanting. It is concluded that the expolinear growth model can be a useful tool for quantifying the growth and yield of common ice plant in a closed plant production system.

Development of an Imaging-DOAS System for 2-D Remote Sensing of Atmospheric Gases (대기가스오염물질의 이차원 원격 모니터링을 위한 Imaging-DOAS 개발)

  • Lee, Han-Lim;Lee, Chul-Kyu;Jung, Jin-Sang;Park, Jeong-Eun;Kim, Young-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.150-157
    • /
    • 2006
  • Spatially resolved remote identification and quantification of trace gases in the atmosphere is desirable in various fields of scientific research as well as in public security and industrial contexts. Environmental observations investigating causes, extent md consequences of air pollution are of fundamental interest. We present an Imaging-DOAS system, a ground based remote sensing instrument that allows spatially resolved mapping of atmospheric trace gases by a differential optical absorption spectroscopy(DOAS) with sun scattered light as the light source. A passive DOAS technique permits the identification and quantification of various gases, e.g., $NO_2,\;SO_2,\;and\;CH_2O$, from their differential absorption structures with high sensitivity. The Imaging-DOAS system consists of a scanning mirror, a focusing lens, a spectrometer, a 2-D CCD, ad the integral control software. An imaging spectrometer simultaneously acquires spectral information on the incident light in one spatial dimension(column) and sequentially scans the next spatial dimension with a motorized scanning mirror. The structure of the signal acquisition system is described in detail and the evaluation method is also briefly discussed. Applications of imaging of the $NO_2$ contents in the exhaust plumes from a power plant are presented.

Real 3-D Shape Restoration using Lookup Table (룩업 테이블을 이용한 물체의 3-D 형상복원)

  • Kim, Kuk-Se;Lee, Jeong-Gi;Song, Gi-Beom;Kim, Choong-Won;Lee, Joon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.5
    • /
    • pp.1096-1101
    • /
    • 2004
  • The 3-D shape use to effect of movie, animation, industrial design, medical treatment service, education, engineering etc.... But it's not easy to make 3-D shape from the information of 2-D image. There are two methods in restoring 3-D video image through 2-D image; First the method of using a laser; Secondly the method of acquiring 3-D image through stereo vision. Instead of doing two methods with many difficulties, I figure out the method of simple 3-D image in this research paper. We present here a simple and efficient method, called direct calibration, which doesn't require any equations at all. The direct calibration procedure builds a lookup table(LUT) linking image and 3-D coordinates by a real 3-D triangulation system. The LUT is built by measuring the image coordinates of a grid of known 3-D points, and recording both image and world coordinates for each point; the depth values of all other visible points are obtained by interpolation.

ITO 전극에 성장된 ZnO 나노구조의 구조적 및 광학적 특성 연구

  • Lee, Hui-Gwan;Kim, Myeong-Seop;Yu, Jae-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.104-104
    • /
    • 2011
  • ZnO는 3.37 eV의 넓은 에너지 밴드갭을 갖는 투명 전도성 반도체이며 우수한 전기적, 광학적 특성으로 인해 광원소자 개발을 위한 새로운 물질로 많은 주목을 받아왔다. 더욱이, ZnO는 쉽게 나노구조 형성이 가능하기 때문에 이를 응용한 가스센서, 염료감응태양전지, 광검출기 등의 소자 개발이 활발히 이루어지고 있다. 최근에는 GaN 기반 발광다이오드 (light emitting diode, LED)의 광추출 효율을 향상시키기 위한 ZnO 나노구조 응용에 관한 연구가 보고되고 있다. GaN 기반 LED의 경우 반도체 물질과 공기 사이의 높은 굴절률 차이로 인하여 낮은 광추출 효율을 나타낸다. 이를 해결하기 위한 방법으로 표면 roughening, texturing 등 에칭공정을 이용해 광추출 효율을 개선하려는 연구들이 보고되고 있으나, 복잡한 공정과정을 필요로 하고 에칭공정에 의한 소자 표면 손상으로 전기적 특성이 나빠질 수 있다. 반면 전기화학증착법으로 성장된 ZnO 나노구조를 이용할 때, 보다 간단한 방법으로 쉽고 빠르게 나노구조를 형성할 수 있고 낮은 공정온도를 가지기 때문에 소자의 전기적 특성에 큰 영향을 주지 않는다. 수직방향으로 잘 정렬된 ZnO 나노구조를 갖는 LED의 경우 내부 Fresnel 반사 손실을 효과적으로 줄여 발광 효율을 크게 향상시킬 수 있다. 따라서, ZnO 나노구조의 성장제어 및 성장특성을 분석하는 것은 매우 중요하다. 본 연구에서는 ITO glass 위에 ZnO 나노구조를 성장하고 그 특성을 분석하였다. ITO glass 기판 위에 RF magnetron 스퍼터를 사용하여 Al 도핑된 ZnO (AZO)를 얇게 증착한 후 전기화학증착법으로 ZnO 나노구조를 성장하였다. 농도, 인가전압, 공정시간 등 다양한 공정조건을 변화시키면서 성장 메커니즘을 분석하였고, scanning electron microscope (SEM) 및 X-ray diffraction (XRD)을 통하여 구조 및 결정성 등을 분석하였다. 또한, UV-Visible-NIR spectrophotometer를 사용하여 투과율을 실험적으로 측정하여 ZnO 나노구조의 광학적 특성을 분석하였고, rigorous coupled wave analysis (RCWA) 방법을 사용하여 계면에서 발생하는 내부 반사율을 계산함으로써 나노구조의 효과를 이론적으로 분석하였다.

  • PDF

A Study on Image Processing For Local Dimming Of LED BLU (LED BLU 분할구동(Local Dimming)을 위한 영상처리 알고리즘에 관한 연구)

  • Kwak, Nae Joung;Han, Seung Hun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.602-606
    • /
    • 2008
  • LCD is supplied light by BLU(Back Light Unit) and the light represents color by each color filter. Also LCD adjusts the amount of light by controlling liquid crystal between the glass of upper plate and one of lower. However, it is impossible to completely exclude light due to the structural and physical characteristic of liquid crystal. Therefore, on transfering light through optical sheet and liquid crystal, many problems are generated. They are related with energy efficiency and get effective for the contrast of LCD to have lower contrast ratio than other display devices. To solve the problems, many techniques have been studied and developed but don't exist keys to solution for them. Among methods, local dimming is one example to be applied to LCD. In this paper we propose image processing algorithm for local dimming of BLU of LED used as light source. The proposed algorithm extracts maximum luminance signal and lights using each extracted signal on segmented region of BLU. Also the proposed algorithm generates image signal in corresponding to luminance of the segmented region and supplies them with LCD panel to represent image with improving luminance ratio.

  • PDF

Growth and Phytochemical Contents of Ice Plant as Affected by Light Quality in a Closed-type Plant Production System (완전제어형 식물생산시스템에서 광질에 따른 아이스플랜트의 생육과 기능성물질 함량)

  • Kim, Young Jin;Kim, Hye Min;Hwang, Seung Jae
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.878-885
    • /
    • 2016
  • A study was conducted to examine the effects of light quality on the growth and phytochemical contents of ice plant in a closed-type plant production system. Seeds were sown in a 128-cell plug tray using rockwool. The seedlings were then transplanted into a deep floating technique system with recirculating nutrient solution (EC $1.5dS{\cdot}m^{-1}$, pH 6.5) in a closed-type plant production system. The nutrient solution was supplied at two weeks after transplanting with 2.0 mM NaCl concentration in all treatments for the development of the bladder cells. The three light sources with different light qualities used were as followed; FL (fluorescent lamps), combined RW LED (red:white = 7:3), and combined RBW LED (red:blue:white = 8:1:1) at $150{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD with a photoperiod of 14/10 hours (light/dark). The results showed that the FL treatment had the greatest growth enhancement effects on the leaf area and the fresh and dry weights of the shoots and roots. The SPAD values were significantly higher under the FL and RBW LED treatments, at 29.8 and 30.6, respectively. No significant difference was observed in salinity under all treatments. Chlorophyll fluorescence was significantly higher under the FL treatment. The total phenol content and antioxidant activity were the highest under the RBW LED treatment. The total flavonoid content was significantly higher under the RBW LED and FL treatments. Hence, the results indicate that the growth of ice plant was maximized under the FL treatment. The phytochemical contents were maximized under the RBW LED treatment.

Laver(Kim) Thickness Measurement and Control System Design (해태(김)두께측정 및 조절 장치 설계)

  • Lee, Bae-Kyu;Choi, Young-Il;Kim, Jung-Hwa
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.226-233
    • /
    • 2013
  • In this study, In Laver's automatic drying device, laver thickness measurement and control devices that are associated with. Disconnect the water and steam, after put a certain amount of the mixture(water and laver) in the mold. In process, Laver of the size and thickness (weight) to determine, constant light source to detect and image LED Lamp occur Vision Sensor (Camera) prepare, then the values of these state of the image is transmitted in real time embedded computers. Built-in measurement and control with the purpose of the application of each of the channels separately provided measurements are displayed on a monitor, And servo signals sent to each of the channels and it become so set function should be. In this paper, the laver drying device, prior to the laver thickness measurement and control devices that rely on the experience of existing workers directly laver manually adjust the thickness of the lever, but the lever by each channel relative to the actuator by installing was to improve the quality. In addition, The effect of productivity gains and labor savings are.

다양한 활성제 이온이 치환 고용된 MgNb2O6 형광체의 특성

  • Kim, Ji-Seon;Jo, Sin-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.167-167
    • /
    • 2013
  • 최근에 산화물 형광체는 황화물 형광체에 비해 높은 화학적 안정성을 나타내기 때문에 백색 발광 다이오드, 전계방출 디스플레이와 플라즈마 디스플레이 패널에 그 응용성을 넓히고 있다. 마그네슘 니오베이트(magnesium niobate, MgNb2O6)는 우수한 유전 특성(상대 유전상수=18.4)을 나타내기 때문에 마이크로파 유전체로 응용 가능하며, 단일상 릴랙서 페라브스카이트(relaxor perovskite) Pb(Mg1/3Nb2/3)O3을 합성하기 위한 전구체 (precursor)로 널리 사용되고 있으며, 나이오븀산염 이온에서 다양한 색상을 방출하는 활성제 이온으로 효율적인 에너지 전달이 일어남으로써 Sm3+, Dy3+, Eu3+와 같은 희토류 이온의 좋은 모체 격자로 개발할 수 있다. 본 연구에서는 마그네슘 니오베이트 MgNb2O6 모체 결정에 다양한 활성제 이온, 즉 Eu3+, Sm3+, Dy3+, Tb3+를 선택적으로 주입하여 발광 효율이 높은 천연색 형광체를 합성하고자 한다. 특히, 모체 결정에 주입되는 활성제 이온 주위의 국소적인 환경이 반전 대칭에서 변형되는 척도를 조사하여 활성제의 주 발광 파장의 세기가 최대가 되는 최적의 조건을 결정하고자 한다. Mg1-1.5xNb2O6:REx3+ 형광체 분말 시료는 초기 물질 MgO, Nb2O5와 희토류 이온을 화학 반응식에 맞게 정밀 저울로 측량하여 플라스틱 용기에 ZrO2 볼과 함께 넣고, 소정의 에탄올을 채운 뒤 밀봉하고서, 300 rpm의 속도로 20시간 볼밀 (ball-mill) 작업을 수행하였다. 그 후, 체(sieve)로 ZrO2 볼을 걸러낸 다음에 혼합된 용액을 각 비커에 담아서 $40^{\circ}C$의 건조기에서 24시간 건조하였고, 건조된 시료를 막자 사발에 넣고 잘게 갈고 80 ${\mu}m$의 체로 걸러낸 후에, 알루미나 도가니에 활성제 이온별로 각각 담아, 전기로에 장입하여 매분당 $5^{\circ}C$의 비율로 온도를 상승시켜 $350^{\circ}C$에서 5시간 동안 하소 공정을 실시한 후에, 온도를 계속 일정한 율로 증가시켜 $1,200^{\circ}C$에서 5시간 동안 소성하여 합성하였다. 합성된 형광체 분말의 결정 구조는 $Cu-K{\alpha}$ 복사선(파장: 1.5406)을 사용하여 X-선회절장치로 측정하였으며, 형광체의 표면 형상은 전계형 주사전자현미경으로 관측하였다. 흡광와 발광스펙트럼은 제논 램프를 광원으로 갖는 형광 광도계를 사용하여 측정하였다. 모체 결정에 활성제 이온 Eu3+, Sm3+, Dy3+, Tb3+가 도핑된 형광체 분말은 각각 적색, 주황색, 황색, 녹색 발광이 관측되었다. 각 발광 스펙트럼과 결정 입자의 크기와 형상 사이의 상호 관계를 조사하였다. 실험 결과로부터, 각 형광체의 발광 파장은 활성제 이온의 종류 와 서로 밀접하게 관련되어 있으며, 형광체 시료 합성시 활성제 이온의 농도를 선택적으로 조절함으로써 발광의 세기를 제어할 수 있음을 확인하였다.

  • PDF

Effects of Light Intensity, Light Quality and Photoperiod for Growth of Perilla in a Closed-type Plant Factory System (완전제어형 식물공장에서 광량과 광질, 광주기가 들깨의 생장에 미치는 영향)

  • Sul, Seonggwan;Baek, Youngtaek;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.180-187
    • /
    • 2022
  • In order to select suitable light in a plant factory, electric energy use efficiency and light use efficiency should be considered simultaneously to consider operating costs as well as quantitative and functional aspects. The growth characteristics, electric energy use efficiency, light use efficiency by light intensity, LED ratio, and photoperiod conditions were compared together. Light intensity is 60, 130, 230, and 320 µmol·m-2·s-1 treatments, and light quality is the mixing ratio of red light and blue light 8:2, 6:4, 4:6, and 2:8 treatments. Photoperiod is 9, 12, 15, and 18 hours treatments based on the daytime. In the light intensity experiment, the growth rate increased as the light intensity increased, but there was no significant difference in the light use efficiency. When comparing the leaf fresh weight per power consumption, only the 320 µmol·m-2·s-1 treatment group showed significantly low efficiency, and there was no significant difference in the other treatments, so 230 µmol·m-2·s-1, which produced the most, was the most efficient. In the light quality experiment, the ratio of red light and blue light was measured to be high at the same time as the growth rate and light use efficiency in RB 8:2, and there was no significant difference in color difference and flavonoids content, so a Red:Blue ratio of 8:2 was the most suitable condition. In the photoperiod experiment, the longer the photoperiod, the higher the growth rate. However, there was no significant difference in the growth rate over 12 hours of daytime, so 12 hours considering the light consumption efficiency was a suitable condition. Based on the above results, LED light environmental conditions for perilla growth in plant factories were light intensity, light quality, and day length of 230 µmol·m-2·s-1 or more, 8:2, and 12 hours or more, respectively.

Growth Characteristics of Common Ice Plant (Mesembryanthemum crystallinum L.) on Nutrient Solution, Light Intensity and Planting Distance in Closed-type Plant Production System (완전제어형 식물 생산 시스템에서 배양액, 광도 및 재식거리에 따른 Common Ice Plant의 생육 특성)

  • Cha, Mi-Kyung;Park, Kyoung Sub;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • This study was conducted to determine the optimum nutrient solution, pH, irrigation interval, light intensity and planting density to growth of common ice plant (Mesembryanthemum crystallinum L.) in a closed-type plant production system. Three-band radiation type fluorescent lamps with a 12-h photoperiod were used. Nutrient film technique systems with three layers were used for the plant growth system. Environmental conditions, such as air temperature, relative humidity and $CO_2$ concentration were controlled by an ON/OFF operation. Treatments were comparison of the nutrient solution of Horticultural Experiment Station in Japan (NHES) and the nutrient solution of Jeju National University (NJNU), pH 6.0 and 7.0, irrigation interval 5 min and 10 min, light intensity 90 and $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and within-row spacing 10 cm, 15 cm, 20 cm and 25 cm with between-row spacing 15 cm. Optimum macronutrients were composed N 7.65, P 0.65, K 4.0, Ca 1.6 and Mg $1.0mM{\cdot}L^{-1}$. There were no significant interactions between pH 6.0 and 7.0 about shoot fresh weight and shoot dry weight of common ice plant. Irrigation interval 5 min and 10 min was also the same result. Shoot fresh weight and shoot dry weight were highest at $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Shoot fresh weight and shoot dry weight were decreased according to increasing the planting density. From the above results, we concluded that optimum nutrient solution, optimum levels of pH, irrigation interval, light intensity and planting density were 6.0-7.0 and 10 min, $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and $15{\times}15cm$, respectively for growth of common ice plant in a closed-type plant production system.