• Title/Summary/Keyword: 광역에너지

Search Result 217, Processing Time 0.027 seconds

A Comparative Study on the Plans for Strategic Environmental Assessment in Korea and Foreign Countries (국내외 전략환경평가 대상계획 비교 연구)

  • Oh, Jinkwan;Kwon, Younghan
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.3
    • /
    • pp.244-259
    • /
    • 2015
  • The Strategic Environmental Impact Assessment(SEIA) in Korea has been introduced and implemented for 15 policy-level plans and 86 project-level plans since 2012. Lately an important issue of the Environmental Impact Assessment(EIA) policy has been emerged regarding the expansion of the policy-level plans subjected to SEIA. Thus, we propose the plans that need to be included in the system, compared with those subjected to the Strategic Environmental Assessment(SEA) enforced in the law or the guideline of 10 foreign counties, especially with those of Germany, France, Italy, the United Kingdom, and Netherlands. Specifically the study suggests that plans related to energy as well as land use, which are well known to cause potential environmental impacts and subjected to the federal-level SEA in those countries, should be the subject of SEIA.

A Study on the Algorithm for the Determination of Fault Section in Bidirectional Distribution Line (양방향 배전선로에서 고장구간 판단 알고리즘 연구)

  • Park, Hak-Yeol;Seo, Dong-Kwen
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.521_523
    • /
    • 2009
  • 최근 고유가에 따른 발전비용 증가와 교토의정서 발휘로 인한 $CO_2$ 저감의무 등 환경보전이라는 사회적 요구와 맞물려 새로운 신재생에너지 분야에 관심이 고조되고 있는 실정이다. 이러한 신재생에너지로 대표되는 풍력, 태양광, 연료전지 등을 이용하는 발전방식은 저용량의 발전으로 대규모 집중형 전원이 아니 전력 수요지 근방에서 설치되는 비교적 작은 규모의 분산형전원(DG;Distribution Generator)으로 배전선로에 직접 연계됨에 따라 배전계통에도 큰 변화가 일고 있다. 분산전원(DG)이 배전계통에 연계됨에 따라 전압변동에 따른 전압조정, 고조파 계통유입에 따른 전기품질, 계통고장시의 분산전원의 단독운전 방지, 고장전류의 분산에 따른 선로의 보호협조 등 다양한 새로운 문제점이 대두되고 있고 이를 해결하기 위해 연구개발 및 신기자재개발 등이 활발히 진행되고 있다. 현재 배전자동화시스템에 적용되고 있는 고장검출 알고리즘은 단방향으로 전기를 공급하던 전통적인 배전방식에서 단순 과전류요소에 의해 고장검출하는 알고리즘을 적용하고 있기 때문에 분산전원이 연계된 양방향 전기공급 배전계통에서는 정확하게 고장구간을 검출하기 어렵다. 이로 인해 고장판단 문제점과 보호기기의 오동작 등으로 정확하게 고장구간을 판단하지 못하여 광역정전이 발생되고 고장복구가 장시간 소요되고 있는 실정이다. 본 논문에서는 이를 해소하기 위해 양방향 전기공급 배전계통에서 고장이 발생시 고장점으로 유입되는 고장전류의 파형형태를 분석하여 고장 구간을 판단하는 알고리즘을 소개하고자 한다. 또한 다기능 mFRTU(mFRTUmulti-function Feeder Remote Terminal Unit) 의 고장 구간 판단 알고리즘의 신뢰성을 검증하기 위해 실선로에서 실증시험을 시행하였으며, 그 결과를 분석하여 타당성을 제시하고자 한다.

  • PDF

Distribution characteristics of geothermal anomalies related with direction of faults and lineaments (지열분포와 단층 및 선구조 방향성과의 상호연관성)

  • Baek, Seung-Gyun;Kim, Hyoung-Chan;Lee, Cheol-Woo;Park, Jeong-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.608-610
    • /
    • 2009
  • 지열 분포에 관련된 지질구조의 특성을 파악하기 위하여 지온경사, 지열류량 자료와 인접한 선구조의 방향성에 대한 상관성 분석을 실시하였다. GIS를 이용하여 지열정보데이터베이스에서 발췌한 209개 지온경사 자료와 218개 지열류량 자료에 대하여 전국 광역단열도로부터 가장 인접한 선구조를 추출하고 10도 간격의 방향별 지온경사 및 지열류량 자료 빈도 및 평균값을 그래프에 도시하였다. 인접 선구조의 방향별 지온경사 평균은 $N30^{\circ}{\sim}40^{\circ}W$, $N10^{\circ}{\sim}20^{\circ}E$ 방향에서 $58.9^{\circ}C/km$, $54.9^{\circ}C/km$로 가장 높았고, 인접 선구조의 방향별 지열류량 평균은 $N80^{\circ}{\sim}90^{\circ}W$, $N50^{\circ}{\sim}60^{\circ}W$ 방향에서 98.71 $mW/m^2$, $98.70mW/m^2$로 가장 높았다. 각 선구조 상의 좌표들을 이용하여 지열류량 분포도에서 지열류량 값을 추출한 결과 $N10^{\circ}W{\sim}N40^{\circ}E$, $N60^{\circ}{\sim}70^{\circ}W$, $N50^{\circ}{\sim}60^{\circ}E$ 방향의 지열류량 높은 것으로 나타났다. 결과적으로 지온경사와 지열류량 자료에 대한 인접 선구조의 방향은 북북동, 북서, 서북서 방향이 우세한 것으로 나타났다. 이는 우리나라 조구조 운동과 관련한 단층, 절리 등의 단열구조의 우세 방향과 잘 일치하는 것으로 해석된다.

  • PDF

Analyzing the Effects on Korean Regional Economy-Energy-Environment Gaps of GFGs Reduction (온실가스 감축의 지역간 격차 영향 분석)

  • Kim, Jae Hyun;Jeong, Kiho
    • Environmental and Resource Economics Review
    • /
    • v.20 no.2
    • /
    • pp.199-228
    • /
    • 2011
  • In this study, the effect on the economy-energy-environment gap among regions of reducing GHGs is analyzed under various scenarios, using a multiregional dynamic CGE model. Regions in Korea are classified as six metropolitan areas. Scenarios are set in three cases such as self-regulatory measures, carbon tax and emissions trading scheme. The reduction target under each scenario is again classified according to volume basis and intensity basis. In results, self-regulation is shown to deepen the economic divide mostly, followed by a carbon tax, emissions trading scheme in order. This result could be interpreted such that a system based on market incentives gives less effect on the gap among regions. However, market incentives based system is expected to take time to build. Thus in implementing policies to increase short-term effects of the reduction targets, complementary policies are needed to reduce the regional devide.

  • PDF

Mapping of Areal Evapotranspiration by Remote Sensing and GIS Techniques (RS/GIS수법을 이용한 廣域蒸發散量의 추정)

  • 安忠鉉
    • Korean Journal of Remote Sensing
    • /
    • v.11 no.1
    • /
    • pp.65-80
    • /
    • 1995
  • Remote Sensing data with ancillary ground-based meteorological data provides the capalility of computing threeof the four surface energy balance components(i.e. net radiation, soil heat flux and sensible heat flux) at different spatial and temporal scales. As a result, this enablis the estimation of the remaining term, latent heat flux. One of the practical applications with this approach is to produce evapotranspiration maps over large areas. This results could estimate and reproduce areal evapotranspiration over large area as much as several hundred sequare kilometers. Moreover, some calculating simulations for the effects of the land use change on the surface heat flux has been made by this method, which is able to estimate evapotranspiration under arbitracy presumed condition. From the simulation of land use change, the results suggests that the land use change in study area can be produce the significant changes in surface heat flux. This preliminary research suggests that the future research should involve development of methods to account for the variability of meteorological parameters brought about by changes in surface conditions and improvements in the modeling of sensible heat transfer across the surface atmosphere interface for partical canopy conditions using remote sensing information.

Analysis of Determinants of Carbon Dioxide Emissions in Korea: Considering Cross-sectional Dependence and Heterogeneous Coefficient (우리나라 이산화탄소 배출량 결정요인 분석: 횡단면 의존성과 계수 이질성을 고려하여)

  • Kim, So-youn;Ryu, Suyeol
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.400-410
    • /
    • 2021
  • This study analyzed the determinants of carbon dioxide emissions through the expanded STIRPAT model using panel data from 16 metropolitan cities and provinces in Korea from 2000 to 2019. After testing cross-sectional dependence and coefficient heterogeneity of panel data, we performed analysis using MG, CCEMG, and AMG estimation methods reflected these characteristics. The results of analysis using the AMG estimation method are as follows. The coefficients of income, population, and energy intensity were statistically significant with a positive sign, but urbanization was statistically insignificant. Reduction of carbon dioxide emissions in Korea can be achieved through an increase in energy efficiency and sustainable economic growth. It is necessary to establish a policy that can contribute to sustainable economic growth by inducing productivity improvement through technology innovation reducing carbon dioxide emissions in the long-term as well as building a low-carbon society through active development of carbon dioxide reduction technology.

Application of analytic hierarchy process technique for selecting a hydrothermal energy site (수열에너지 입지 선정을 위한 계층화분석법의 적용)

  • Joohyun Ahn;Suwan Park;Changhyun Oh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.2
    • /
    • pp.69-81
    • /
    • 2024
  • In this study, an evaluation system that can be used to evaluate the feasibility of developing and supplying hydrothermal energy for the operation of large-scale complex facilities was developed. To this end, this study derived factors to be considered when selecting a location for the use of hydrothermal energy using raw water from multi-purpose dams and regional water supply systems through literature survey and expert interviews. The evaluation indicators derived from this study are divided into four sectors: hydrothermal energy utilization factors, location factors, planning factors, and disaster safety factors, and are composed of 10 mid-level indicators and 34 detailed planning indicators. The relative importance of all factors was derived using the Analytic Hierarchy Process (AHP) technique, and the developed evaluation indicators and relative importance were applied to four multi-purpose dam regions in the country. As a result, it was found that in the development and use of hydrothermal energy utilizing regional raw water supply line the urban planning conditions of the supply site can have a greater impact on the location selection results than the hydrothermal energy development itself. Due to the characteristics of the evaluation indicators developed in this study and their nature as comprehensive indicators, it is believed that the results should be applied to determine the overall adequacy of site selection in the early stages of hydrothermal energy development. In the future, it is believed that it will be necessary to analyze the problems in supplying and operating hydrothermal energy using raw water from multi-purpose dams and regional water resources. Based on the analysis the evaluation system developed in this study is expected to be improved and supplemented.

The Evaluation Technique of Surface Region using Backward-Radiated Ultrasound (후방 복사된 초음파를 이용한 표면 지역의 평가 기술)

  • Kwon, S.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.4
    • /
    • pp.241-250
    • /
    • 1997
  • The velocity dispersion of surface acoustical wave(SAW) of Si layer/mesh Au/Si substrate was measured by the frequency analysis technique of backward radiation at liquid/solid interface. The difference of backward radiation patterns depending on used transducers (2, 5, 10MHz) confirmed that the backward radiation phenomenon was caused by the energy radiation from SAW generated in surface region. An ultrasonic goniometer was constructed to measure continuously the angular dependence of backscattered intensity. The angular dependences of backward radiation(5MHz) were measured for Ni layer/Al substrate specimens that were bonded by epoxy involving different content of Cu powder. It was known that the width and pattern of backward radiation had informations such as the velocity dispersion, bonding quality and structure of surface region.

  • PDF

Real-Time Pump Scheduling Technique for Optimal Operation of Water Distribution System (관망운영 최적화를 위한 실시간 펌프스케줄링 기법 개발)

  • Woo, Hyoung Min;Kim, Ju Hwan;Ahn, Hyo Won;Yoon, Jae Heung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1316-1320
    • /
    • 2004
  • 생활수준의 향상과 기술발전에 따라 상수도 관망시스템에 관할 관점 또한 기존의 설계 및 해석의 개념에서 안정적이고 효율적인 용수공급 운영의 측면으로 변화하고 있다. 본 연구에 서는 상수도 시스템을 효율적으로 운영하기 위한 방법을 관망운영의 측면에서 모색하였으며, 수도권 광역상수도를 대상으로 하여 시범 적용하였다. 본 연구는 현재 시점에서 안정적인 용수공급이 가능한 가능최소 에너지 비용을 구하는 것이 목적이다 용수수요량의 변화 등 운영여건이 바뀌게 되면, 수리적 안정성이 확보되는 범위내에서 가능한 최적의 펌프운영패턴을 도출하였다. 현재 용수공급량 변동시 또는 연계운영 방법의 변경시와 같은 운영여건 변동에 따른 경제적운영 방안 등에 대한 연구가 미비하여 가장 최적의 운영방안 도출이 어려운 실정이므로, 본 연구를 통하여 연계운영에 최적화 기법의 적용 및 운영방안의 도출을 수행하였다. 운영여건의 변경시 펌프장 등에서의 전력원단위 변화 등 각 단계별 수도시설의 종합적 고려를 통한 경제적 운영방안을 검토할 수 있는 상수관망 최적운영모형의 실제 탑재 모델을 개발하였으며, 이를 기반으로 하여 실제 현장에서 담당자가 쉽게 사용할 수 있는 사용자 편의 환경을 개발하였다.

  • PDF

A Study on Investigating Actual State of Operation of Building Integrated Photovoltaic for the Spread of BIPV (건축물에 적용된 태양광발전시스템의 운전실태 조사 및 보급 확대에 관한 연구)

  • Kim, Byung-Joon;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.327-330
    • /
    • 2005
  • Today, the need for alternative energy has increased due to the global environmental problems and energy depletion. In order to solve a global environmental matter and an energy issue simultaneously, the application of the renewable energies in building has been constantly demanded. therefore, we must develop new energy resources that are abundant and provide substitutes for fossil fuels and we must study the application method of the renewable energies in building. Among renewable energies, the solar energy(photovoltaic system) is clean, inexhaustible, and available everywhere in the world and is judged to have the application possibility in building. Daegu city has a plan of putting a photovoltaic system on large buildings. For instance, EXCO, exhibition and convention building, and dormitory in Kyungpook National University, Dongho elementary school, Osan building in Keimyung University, Young korea academy in Daegu, are on the process of having a photovoltaic system. Therefore a study on the performance of photovoltaic system is important for the system design and maintenance. this paper describes the first invest cost, and performance test of the 95kW utility-interactive photovoltaic power system.

  • PDF