• Title/Summary/Keyword: 광시야

Search Result 157, Processing Time 0.019 seconds

Catadioptric Omnidirectional Optical System Using a Spherical Mirror with a Central Hole and a Plane Mirror for Visible Light (중심 구멍이 있는 구면거울과 평면거울을 이용한 가시광용 반사굴절식 전방위 광학계)

  • Seo, Hyeon Jin;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.2
    • /
    • pp.88-97
    • /
    • 2015
  • An omnidirectional optical system can be described as a special optical system that images in real time a panoramic image with an azimuthal angle of $360^{\circ}$ and the altitude angle corresponding to the upper and lower fields of view from the horizon line. In this paper, for easy fabrication and compact size, we designed and fabricated a catadioptric omnidirectional optical system consisting of the mirror part of a spherical mirror with a central hole (that is, obscuration), a plane mirror, the imaging lens part of 3 single spherical lenses, and a spherical doublet in the visible light spectrum. We evaluated its image performance by measuring the cut-off spatial frequency using automobile license plates, and the vertical field of view using an ISO 12233 chart. We achieved a catadioptric omnidirectional optical system with vertical field of view from $+53^{\circ}$ to $-17^{\circ}$ and an azimuthal angle of $360^{\circ}$. This optical system cleaniy imaged letters on a car's front license plate at the object distance of 3 meters, which corresponds to a cut-off spatial frequency of 135 lp/mm.

Optical Simulation Study of the Improvement of Color-rendering Characteristics of White Light-emitting Diodes by Using Red Quantum-dot Films (적색 양자점 필름을 이용한 백색 발광 다이오드의 연색성 개선에 대한 광학 시뮬레이션 연구)

  • Lee, Gi Jung;Hong, Seung Chan;Lee, Jung-Gyun;Ko, Jae-Hyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.4
    • /
    • pp.163-171
    • /
    • 2021
  • Conventional white light-emitting diodes (LEDs) for lighting applications consist of blue LEDs and yellow phosphors, the spectrum of which lacks deep red. To improve the color-rendering characteristics of white LEDs, a red quantum-dot film was applied to the diffuser plate of LED lighting. The mean free paths of the quantum dots and the concentration of the TiO2 particles in the diffuser plate were adjusted to optimize the optical structure of the lighting. The color-rendering index (CRI) was greater than 90 for most conditions, which demonstrates that adoption of the red quantum-dot film is an effective way for improving the color-rendering properties of conventional white LEDs. The angular dispersion of color coordinates could be removed by utilizing the optical cavity formed between the diffuser plate and the reflector on the bottom of the lighting, where multiple passages of the light through the quantum-dot film reduced the differences in optical path length depending on the viewing angle.

Design and Fabrication of Binary Diffractive Optical Elements for the Creation of Pseudorandom Dot Arrays of Uniform Brightness (균일 밝기 랜덤 도트 어레이 생성을 위한 이진 회절광학소자 설계 및 제작)

  • Lee, Soo Yeon;Lee, Jun Ho;Kim, Young-Gwang;Rhee, Hyug-Gyo;Lee, Munseob
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.267-274
    • /
    • 2022
  • In this paper, we report the design and fabrication of binary diffractive optical elements (DOEs) for random-dot-pattern projection for Schlieren imaging. We selected the binary phase level and a pitch of 10 ㎛ for the DOE, based on cost effectiveness and ease of manufacture. We designed the binary DOE using an iterative Fourier-transform algorithm with binary phase optimization. During initial optimization, we applied a computer-generated pseudorandom dot pattern of uniform intensity as a target pattern, and found significant intensity nonuniformity across the field. Based on the evaluation of the initial optimization, we weighted the target random dot pattern with Gaussian profiles to improve the intensity uniformity, resulting in the improvement of uniformity from 52.7% to 90.8%. We verified the design performance by fabricating the designed binary DOE and a beam projector, to which the same was applied. The verification confirmed that the projector produced over 10,000 random dot patterns over 430 mm × 430 mm at a distance of 5 meters, as designed, but had a slightly less uniformity of 84.5%. The fabrication errors of the DOE, mainly edge blurring and spacing errors, were strong possibilities for the difference.

Design a Four Layer Depth-Encoding Detector Using Quasi-Block Scintillator for High Resolution and Sensitivity (고분해능 및 고민감도를 위한 준 블록 섬광체를 사용한 네 층의 반응 깊이 측정 검출기 설계)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.65-71
    • /
    • 2024
  • To achieve high resolution and sensitivity of positron emission tomography (PET) for small animals, the detector is constructed using very thin and long scintillation pixels. Due to the structure of these scintillation pixels, spatial resolution deterioration occurs outside the system's field of view. To solve this problem, we designed a detector that could improve spatial resolution by measuring the interaction depth and improve sensitivity by using a quasi-block scintillator. A quasi-block scintillator size of 12.6 mm x 12.6 mm x 3 mm was arranged in four layers, and optical sensors were placed on all sides to collect light generated by the interaction between gamma rays and the scintillator. DETECT2000 simulation was performed to evaluate the performance of the designed detector. Flood images were acquired by generating gamma-ray events at 1 mm intervals from 1.3 mm to 11.3 mm within the scintillator of each layer. The spatial resolution and peak-to-peak distance for each location were measured in an 11 x 11 array of flood images. The average measured spatial resolution was 0.25 mm, and the average distance between peaks was 1.0 mm. Through this, it was confirmed that all locations were separated from each other. In addition, because the light signals of all layers were measured separately from each other, the layer of the scintillator that interacted with the gamma rays could be completely separated. When the designed detector is used as a detector in a PET system for small animals, it is considered that excellent spatial resolution and sensitivity can be achieved and image quality can be improved.

PROPOSAL OF NEW DENIAL COLOR-SPACE FOR AESTHETIC DENIAL MATERIALS (치과용 심미 수복 재료들의 색상 연구를 통한 새로운 치과용 색체계의 제안)

  • Oh, Yun-Jeong;Park, Su-Jung;Kim, Dong-Jun;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • The purpose of this study is to develope new dental color-space system. Twelve kinds of dental composites and one kind of dental porcelain were used in this study. Disk samples (15 mm in diameter, 4 mm in thickness) of used materials were made and sample's CIE $L^*a^*b^*$ value was measured by Spectrocolorimeter (MiniScan XE plus, Model 4000S, diffuse/$8^{\circ}$ viewing mode, 14.3 mm Port diameters, Hunter Lab USA) The range of measured color distribution was analyzed. All the data were applied in the form of T### which is expression unit in CNU Cons Dental Color Chart. The value of $L^*$ lies between 80.40 and 52.70. The value of $a^*$ are between 10.60 and 3.60 and $b^*$ are between 28.40 and 2.21. The average value of $L^*$ is 67.40, and median value is 67.30. The value of $a^*$ are 2.89 and 2.91 respectively. And for the $b^*$, 14.30 and 13.90 were obtained. The data were converted to T### that is the unit count system in CNU-Cons Dental Color Chart. The value of $L^*$ is converted in the first digit of the numbering system. Each unit is 2.0 measured values. The second digit is the value of $a^*$ and is converted new number by 1.0 measured value. For the third digit $b^*$ is replaced and it is 2.0 measured unit apart. T555 was set to the value of $L^*$ ranging from 66.0 to 68.0, value of $a^*$ ranging from 3 to 4 and $b^*$ value ranging from 14 to 16.

ALGORITHMS FOR MOVING OBJECT DETECTION: YSTAR-NEOPAT SURVEY PROGRAM (이동천체 후보 검출을 위한 알고리즘 개발: YSTAR-NEOPAT 탐사프로그램)

  • Bae, Young-Ho;Byun, Yong-Ik;Kang, Yong-Woo;Park, Sun-Youp;Oh, Se-Heon;Yu, Seoung-Yeol;Han, Won-Young;Yim, Hong-Suh;Moon, Hong-Kyu
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.4
    • /
    • pp.393-408
    • /
    • 2005
  • We developed and compared two automatic algorithms for moving object detections in the YSTAR-NEOPAT sky survey program. One method, called starlist comparison method, is to identify moving object candidates by comparing the photometry data tables from successive images. Another method, called image subtraction method, is to identify the candidates by subtracting one image from another which isolates sources moving against background stars. The efficiency and accuracy of these algorithms have been tested using actual survey data from the YSTAR-NEOPAT telescope system. For the detected candidates, we performed eyeball inspection of animated images to confirm validity of asteroid detections. Main conclusions include followings. First, the optical distortion in the YSTAR-NEOPAT wide-field images can be properly corrected by comparison with USNO-B1.0 catalog and the astrometric accuracy can be preserved at around 1.5 arcsec. Secondly, image subtraction provides more robust and accurate detection of moving objects. For two different thresholds of 2.0 and $4.0\sigma$, image subtraction method uncovered 34 and 12 candidates and most of them are confirmed to be real. Starlist comparison method detected many more candidates, 60 and 6 for each threshold level, but nearly half of them turned out to be false detections.

A Clinical Study on the Surgical Treatment of the Rheumatic Cardiac Valve Disease (류마티스성 심장판막질환의 외과적 치료에 대한 임상적 연구)

  • 김종원;정황규;이성광;김병준;신영우
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.346-352
    • /
    • 1998
  • Rheumatic valvulitis produces at least three distinct pathologic changes, the degree varying widely among the patients: fusion of the valve leaflets at the commissures; fusion and shortening of chordae tendinae: and fibrosis of the leaflets with subsequent stiffening, contraction and calcification. The most extensive changes usually are seen in patients with recurrent attacks of rheumatic fever. We studied on outcome of the surgical treatments of rheumatic valvular diseases that have been experienced for 12 years since 1982 at Pusan National University Hospital. The diagnoses were made by rheumatic fever history, echocardiographic findings, gross operative findings and microscopic findings. Total 502 patients were performed surgery for valvular heart diseases and 440 patients of rheumatic origin have bene analysed. There were more female than male patients as 1.3:1, and the mean age was 37.8 years old. 96.3% of them affected to the mitral valve, 19.8% to aortic valve, 16.3% affected to the tricuspid valve. Most of them underwent valve replacement, and valve repair was done in 3.9% of patients. There were 36 hospital deaths(8.2%) mainly from low cardiac output syndrome, and 15 late deaths equally due to embolism and hemorrhage. Follow up was 90.1% completed(2890 patient- year). Linealized rates of late complication events are follows : thromboembolism 1.3% per patient year; anticoagulant related hemorrhage 0.8% per patient year. Overall actuarial survival including hospital mortality was 92.7+/-2.9% in 1 year, 88.0+/-4.5% in 5 year, 82.3+/-7.7% in 10 year. We conclude that the rheumatic disease is still the most frequent and the most important cause of heart valve disease. So more intensive study is needed in spite of the abrupt decreasing rate of rheumatic fever in U.S.A. and other industrial country.

  • PDF