• Title/Summary/Keyword: 광도측정

Search Result 337, Processing Time 0.031 seconds

Experience of Reticulocytes Measurement at 720 nm Using Spectrophotometer (분광광도계를 이용한 720 nm에서 망상적혈구 측정 경험)

  • Sung, Hyun-Ho;Seok, Dong-In;Jung, You-Hyun;Kim, Dae-Jung;Lee, Seok-Jae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.382-389
    • /
    • 2017
  • Currently, reticulocyte experimental calculation technology used in clinical laboratories are divided two types: manual and automated. Manual reticulocyte counting using a microscopy lacks accuracy due particularly to its low reproducibility, affecting the accuracy of manual reticulocyte count. Moreover, Automatic blood corpuscle analyzer flow cytometry is difficult to be used in underdeveloped countries and small scale laboratories due to relatively high cost. Therefore, this study tried to find a new method to complement these drawbacks. The aim of this study was to compare the stained reticulocytes count by spectrophotometer and also to analyze the statistics of spectrophotometer and flow cytometer. The same 8 EDTA samples were repeated 36 times to compare the agreement between spectrophotometer and flow cytometer. This study measured the specimen diluted 600 times at 700~780 nm by 10 differences. Wavelength between 710 to 730 by absorbance showed a positive correlation between standard data and test data (r=0.967, p<0.01), presenting a correlation between variables. Statistical analyses of regression for test and standard parametric data, the optimal dilution factor was 600 times. Therefore, this study tried to technical utilizes such as contributing economical for the reticulocyte absorbance apply from the auto spectrophotometer, a monitoring system for the reticulocyte relation anemia, etc. Therefore, more extensive studies, including an auto chemical analyzer application, will be needed.

A Study on the Fabrication LiNbO3 Optical Waveguide (LiNbO3 광도파로 제작에 관한 연구)

  • Kim, Sun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6221-6226
    • /
    • 2015
  • In this paper, waveguide analysis was interpreted as an optical waveguide using the feedback perturbation method simple and easy to apply compared to the analysis method, while the other almost identical to the numerical calculation method. In addition, efficient coupling with an optical transmission line of optical fiber and the waveguide form the thin film of different functional elements is required in order to achieve the full optical communication system. However, problems arise, such as the light field (field) and the decrease of the access efficiency due to inconsistency in the distribution characteristics of the connection surface by the difference in size of the cross section thereof when connecting the optical fiber and the waveguide directly to the combination of a thin film. Therefore propose a new type of connector structure to increase the efficiency of the connection when connecting the optical fiber waveguide and the thin film was analyzed by applying a coupled mode theory, the binding efficiency of the modified contactor. And by diffusing Ti on the $LiNbO_3$ substrate and a wide range of applications in the manufacture of integrated optical material made of a current low-loss Ti: $LiNbO_3$ optical waveguide and making the Y-branch waveguide, and the properties were confirmed.

Development of Active thin Film Optical Waveguide $C^{2+}$ -ion Sensor (능동형 박막 광도파로 칼슘 이온 센서의 개발)

  • Lee, Su-Mi;Gang, Sin-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.49-54
    • /
    • 2000
  • A new functional organic thin film optical waveguide ion sensor is designed, which can select a specific ion, i.e., $Ca^{2+}$ -ion. The sensing membrane was composed of PVC-PVAC-PVA copolymer matrix based on anionic cation-selective chromoionophor(ETH5294), neutral ionophore(K23El), anionic site and plasticizer and it was coated on the etched glass substrate as embeded type optical waveguide itself. The sensor sensitivity dependence on waveguide length and thickness, contence of chromoionophore, and each mode was investigated. And this sensor could detect $Ca^{2+}$ ion in concentrations ranging from 1$\times$10­6~1M(with 0.05M tris-HCI buffer solution of pH7.4) by measuring the absorbance change at 514nm of light. Utilizing thin film membrane, the fast response time and high sensitivity are obtained. Also, it is expected that this sensor can be applied to various biochemical important ions.ons.

  • PDF

Photosynthetic Characteristics of Sedum takevimense on Various Moisture Conditions in a Green Roof System (옥상녹화시스템에서 수분 조건에 따른 섬기린초의 광합성 특성)

  • Li, Hong;Kang, Tai-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.140-146
    • /
    • 2013
  • This experiment was conducted in order to study the physiological characteristics of Sedum takevimense in different moisture conditions. The photosynthetic rate, water use efficiency and the respiratory rate were determined by using a photable photosynthesis system. According to the results, the best illumination range and moisture range were explicitly selected. The highest photosynthetic rate was at $600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and after this value, the trend showed a reduction. When the moisture was 11.31%, the photosynthetic capacity and water use efficiency reached maximum value, but the respiratory rate reached maximum value at 7.91%. According to the measured values, the best illumination range was $600{\sim}1,200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and the best moisture range was 7.09~11.31%.

Fabrication of Wavelength Division Demultiplexing Photodetectors Using Quantum Well Intermixing (다중양자우물의 상호 섞임 현상을 이용한 다중파장검출기의 제작)

  • Yeo, Deok-Ho;Yoon, Kyung-Hun;Kim Sung-June
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.9
    • /
    • pp.1-6
    • /
    • 2000
  • Utilizing impurity free vacancy diffusion (IFVD) method, area selective intermixing of InGaAs/InGaAsP multi-quantum well (MQW) structure was done. After this, wavelength division demultiplexing waveguide type photodetectoers was integrated and measured. It showed large blue shift in bandgap due to intermixing of MQW. Photodetectors are based on typical p-i-n structure and devices having large and small bandgap areas line up linearly. Width of waveguide and length of each photodetector are 20 and 250 ${\mu}m$, respectively, TE/TM polarized light from tunable laser was butt-coupled to the photodetector and spectral response was measured. Photodetectors can demultiplexing 1480 and 1550 nm wavelength.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH BY PLASMA ARC CURING SYSTEM FOR BRACKET BONDING (Plasma arc curing system을 이용한 브라켓의 접착에 관한 연구)

  • Kim, Jung-Yoon;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.638-642
    • /
    • 2001
  • Recently, plasma arc curing system for curing resin composites has been introduced. This is characterized by a high output of light energy, which has the advantage of reducing the chair time and thereby making the treatment more comportable for the patients as well as for the dentist. The purpose of this study was to compare the shear bond strengths of light-cured orthodontic adhesive polymerized with conventional halogen light and plasma arc light. The 2 curing devices used were the XL3000 (3M, USA) conventional curing light and the Flipo (LOKKI, France) plasma arc light. The results from the present study can be summarized as fellows; 1. The mean shear bond strength for three groups were quite similar for 50 second conventional light group, 2 second plasma arc curing light group, 5 second plasma arc curing light group. 2. There was no statistically significant difference for three groups(p>0.05).

  • PDF

Measurement and Analysis of Image Brightness in Fiber-optic Imageguide for Ultrathin Endoscope (미세내시경용 광섬유 영상가이드의 영상광도 측정 및 분석)

  • 이봉수
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.263-268
    • /
    • 2002
  • The image quality of imageguide depends on the structure, material, length of microfibers and the phenomena such as cross-talk and leaky ray between adjacent fibers. These Parameters should be considered as important factors in the image transmission qualify of fibers. However it is considered to be very difficult to assess all the parameters in a consistent way Therefore. two image characteristics, image resolution and image brightness are measured and analyzed to determine the image quality of imageguide. But the exact methods to measure two image characteristics of imageguide are not reported. In this study, the image brightness of imageguide for ultrathin endoscope is determined by measuring of the numerical aperture. the packing fraction and the attenuated power ratio of imageguide. Especially it is possible to obtain more exact results from measuring the numerical aperture of whole image guide than those from theoretical calculation of the single microfiber in an image guide. The image brightness of the image guide which has $3.1\mu m$ microfibers is about 37% less than that with $4.1\mu m$ microfibers.

비전리방사선

  • 김윤신
    • Environmental engineer
    • /
    • s.65
    • /
    • pp.18-24
    • /
    • 1992
  • 우리나라와 같이 전기제품의 수출이 전체수출의 많은 부분을 차지하는 상태에서는 전자파장해의 정확한 측정기술의 개발, 전자파대책 부품과 기술개발 등의 연구가 요구되고 있다. 특히 레이저, 마이크로 웨이브 오븐, 고광도 광원 등과 같은 방사선을 이용하거나 발산하는 전자 창작품의 생산이 급격한 성장을 보이고 있는 가운데 비전리 방사선에 의한 공중건강에 관심이 높아지고 있다.

  • PDF

회원사 탐방 - (주)옵토스타

  • Korea Association for Photonics Industry Development
    • Photonics industry news
    • /
    • s.33
    • /
    • pp.20-21
    • /
    • 2006
  • 최고의 성능과 품질을 가진 제품과 서비스로 고객에게 봉사한다는 신념으로 지난 2002년 3월에 설립된 옵토스타(대표 심재기 http://www.optosta.com)는 ETRI Spin-off 기업으로 광도파로 소자 공정, 측정, 패키징 및 신뢰성 시험 등 광집적회로 소자분야의 전문기업이다.

  • PDF