• Title/Summary/Keyword: 관 삽입

Search Result 262, Processing Time 0.025 seconds

Transcatheter Closure of Patent Ductus Arteriosus with a Amplatzer$^{(R)}$ Vascular Plug in Two Dogs (개에서 Amplatzer$^{(R)}$ vascular plug를 이용한 동맥관개존증의 폐쇄 2 증례)

  • Kang, Min-Hee;Kim, Jung-hyun;Moon, So-Jeung;Kim, Seung-gon;Yeo, Jung-Jin;Lee, Chang-Min;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.591-594
    • /
    • 2011
  • A 9-month-old, intact female Maltese dog and one-year-old, intact female beagle dog were presented with continuous heart murmur. These 2 dogs were diagnosed as patent ductus arteriosus (PDA) based on the two-dimensional echocardiography and angiography. Due to the large shunt size, commercially available ductal occlude device was used for transcatheter occlusion of PDA. After Amplatzer$^{(R)}$ vascular plug placement, cardiac murmur was abruptly disappeared in Maltese dog and mildly decreased in beagle dog. Complications and safety after the procedure were evaluated regularly in these 2 dogs. This is first clinical application of Amplatzer$^{(R)}$ vascular plug for transcatheter closure of PDA in two dogs in Korea.

Saline Water Treatment by Underwater Plasma

  • Yu, Seung-Min;Yu, Seung-Yeol;Park, Jun-Seok;Hong, Eun-Jeong;Hong, Yong-Cheol;Lee, Sang-Ju;Kim, Ye-Jin;No, Tae-Hyeop;Lee, Bong-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.19-19
    • /
    • 2011
  • 수중방전은 다양한 라디칼을 직접 물 속에서 발생시키기 때문에 수처리 공정에 다양한 응용이 가능하다. 특히, 최근에 선박평형수 등의 살균이 국제적인 이슈가 되고 있고, 2017년까지는 모든 선박에 살균을 위한 수처리 설비가 의무화된다. 본 연구에서는 염분이 있는 수체에서의 방전공정을 연구하고 이를 수처리공정에 적용할 수 있는 방법에 대해 연구하였다. 해수의 경우 전도도가 53mS로 자유로운 전하의 이동이 가능하기 때문에 일반적인 민물방전의 전원과 전극 등으로는 방전을 할 수 없다. 이에 세라믹과 금속의 이중구조로 되어 있는 모세관전극을 개발하여 전도성이 있는 수체에서의 방전을 이루었다. 전원장치로는 60 Hz, 380 V를 1차측에 인가하여 2차측에서 약 3 kV, 10 kW의 파워가 발생하는 12위상차 교류전원장치를 개발하여 사용하였다. 모세관 내부에 전압이 인가되면 전류가 발생하여 joule heating에 의하여 모세관 내부에 기포가 형성된다. 이 때, 전류의 단락이 이루어지면서 고전압쪽에 전하가 축적되며 기포내부의 E-field가 상승한다. 이후 기포 내에서 방전이 개시되며 각종 라디칼을 생성한다. 방전에 의해 생성되는 산화제로는 오존, OH라디칼, 과산화수소 등이 있으며, 해수에서는 Cl-의 결합에 의하여 Cl2 가스가 발생한다. 약 30,000 J/L의 체적에너지에 대하여 생성되는 총염소의 농도는 2.5 mg/L이다. 수중방전의 적용대상으로 선박평형수, 멤브레인과의 결합, 용존기포부상법을 선정하여 적용가능성을 연구하였다. 먼저 선박평형수 살균처리를 위해 해수의 처리유량을 20 lpm으로 유지하고 대장균, 바실러스, 조류(테트라셀미스) 등을 투입하여 전극 12개가 삽입된 12위상차 플라즈마 반응기를 통과시켰더니, 약 30,000 J/L의 체적에너지에 대하여 1일 후의 살균력이 각각 99.99, 99.99, 99.9%의 살균력을 나타내었다. 이는 국제해사기구에서 권장하는 살균수준인 99.9%를 초과하는 수치이다. 플라즈마를 이용한 해수살균공정의 안정적 운전을 위해 후단에 UF멤브레인을 추가하여 잔류생존 미생물을 제거할 수 있다. 이를 위해 플라즈마가 후단의 멤브레인 운전에 미치는 영향을 평가하였다. 카올린과 탄산칼슘을 오염원으로 각각 투입하여 멤브레인으로 처리를 하였을 때, 방전 직후 멤브레인에 걸리는 막간압력차가 약 30% 감소하였는데, 이는 막에 형성된 파울링이 방전에 의해 제거된 것으로 평가할 수 있다. 수중방전은 다양한 산화제를 생성함과 동시에 미세기포를 발생시키는데 이는 수중유기물의 부상분리에 적용될 수 있다. 방전모세관전극의 내부직경을 1 mm로 유지하고, 60 Hz, 교류전원으로 방전한 결과 평균입경 44 um의 기포를 발생시켰고, 이는 일반적으로 용존공기부상법에 사용되는 기포의 크기와 일치한다.

  • PDF

Determination of volatile and residual iodine during the dissolution of spent nuclear fuel (사용 후 핵연료 용해 중 휘발 및 잔류 요오드 분석)

  • Kim, Jung Suk;Park, Soon Dal;Jeon, Young Shin;Ha, Young Keong;Song, Kyuseok
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.395-406
    • /
    • 2009
  • The determination of iodine in the spent nuclear fuel and the volatile behavior during its acid dissolution have been studied by NAA(neutron activation analysis) and electron probe microanalysis (EPMA). Simulated spent fuels (SIMFUELs) were dissolved in $HNO_3$(1+1) at $90^{\circ}C$ for 8 hours. The iodine remained in a dissolver solution after dissolution, and that condensed in dissolution apparatus and trapped in the adsorbent by volatilization during the dissolution were determined, respectively. The condensed iodine was recovered by the redistillation with $HNO_3$(1+1) after transfer of the dissolver solution. The iodines in the dissolver and redistilled solution were separated by solvent extraction followed by ion exchange or precipitation method and determined by RNAA (radiochemical neutron activation analysis). The ion exchange column and filtration kit used for the isolation of iodine, which were prepared with a polyethylene tube, were used as an insert in the pneumatic tube for neutron irradiation. The iodine volatilized during the dissolution of SIMFUELs was collected in a trapping tube containing Ag-silica gel (Ag-impregnated silica gel) adsorbent, and the distribution of iodine trapped in the adsorbents were determined by EPMA. The adsorbing characteristics shown with the SIMFUELs were compared with those shown with a real spent fuel from the nuclear power plant.

New Fracture Toughness Test Method of Zircaloy-4 Nuclear Fuel Cladding (Zircaloy-4 핵연료 피복관의 신파괴인성 시험법)

  • Oh, Dong-Joon;Ahn, Sang-Bok;Hong, Kwon-Pyo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.5
    • /
    • pp.823-832
    • /
    • 2003
  • To define the causes of cladding degradation which can take place during the operation of nuclear power plants, it is required to develop the new fracture toughness test of spent fuel cladding. The fracture toughness of Zircaloy-4 cladding was estimated using the recently developed KAERI embedded Charpy (KEC) specimen. Axially notched KEC specimens cut directly from unirradiated fuel claddings, were tested in a way similar to the standard toughness test method of a Single Edge Bending (SEB) specimen. The results of KEC fracture toughness test at room temperatures were discussed and compared with those of the previous other studies. In conclusions, even though the KEC fracture toughness test of nuclear fuel claddings was easier and more reliable than those developed earlier, the results from the cladding fracture tests were not the material characteristics but the specific fracture parameters which were deeply related to the specification of claddings. In addition, the phenomenon of a thickness yielding was not observed from the fracture surface. It was closely related to the fact that the plane strain condition of the KEC specimen was changed to the plane stress condition during crack advancing. It was also supported by the fractographic evidence that the formation of ductile dimples at the crack initiation became the similar appearance such as a quasi-cleavage after the sufficient crack advancing.

Leakage-reduction Measures at a Joint between CPVC Piping for a Sprinkler System and a Pipe Expansion (스프링클러설비용 CPVC관과 신축배관 접속부분에서의 누수저감 대책에 관한 연구)

  • Lim, Chun-Ki;Lim, Yun-Tack;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.21-30
    • /
    • 2015
  • In this study, we try to suggest measures to reduce leakage at a joint between CPVC piping for a sprinkler system and a pipe expansion through reviews of domestic and foreign standards and related tests. The quality of the waterproof rubber packing material between a valve socket and pipe expansion nut was examined. In the leak test, the valve socket material over the expansion part of the metal pipe nut was found to use a metal part or a schlorinated polyvinyl chloride pipe nut part. In addition, the KS B 0221 standard for parallel pipe threads with threaded and thread inspection criteria and inspection standards in order to ensure an acceptable quality of valve socket, there is a need to amend the regulations to comply with the KS B 5223 (screw thread limit gauges parallel pipe threads). We do not have detailed standards for expansion piping nuts for waterproof rubber ring material, so we need to amend the relevant criteria for EPDM material to be used with excellent waterproofing, for which both NBR and EPDM are currently used.

The Biomechancial Effects of an Interspinous Spacer Implant on 3-D Motions for the Treatment of Lumbar Spinal Stenosis (요추부 척추관 협착증 치료를 위한 극돌기간 삽입술의 3차원 분석을 통한 생체역학적 효과 분석)

  • 이희성;신규철;문수정;정태곤;이권용;이성재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1207-1210
    • /
    • 2004
  • As many humans age, degenerative lumbar spinal stenosis (DLSS) becomes a major cause of lower limb discomfort and disability. By surgical treatment method of DLSS, the existing surgical treatment methods using internal fixation have showed degeneration changes of an adjacent vertebrae and loss of lumbar spine lordosis-kyphosis due to eliminating a motion. For solving the problems of internal fixation, a novel interspinous spacer has been developed to treat DLSS by surgical treatment method. In this study, we evaluated the biomechanical effects of the interspinous spacer on the kinematics of the porcine lumbar spine before and after insertion of the implant. For this purpose, a device that is capable of measuring 3-D motions were built based on direct linear transformation (DLT) algorithm written with MATLAB program. Results showed that in extension, a change of the mean angle between the intact and the implanted specimens at L4-L5 was 1.87 degree difference and the implant reduced the extension range of motion of the L4-L5 (p<0.05). But the range of motion in flexion, axial rotation and lateral bending at the adjacent segments was not statistically affected by the implant. In conclusion, we thought that interspinous spacer may have remedical value for DLSS by flexing human lumbar spine.

  • PDF

Hybrid Palliation for Functionally Single Ventricle with Systemic Outflow Obstruction (단심증에서의 Hybrid 고식술)

  • Cho, Won-Chul;Song, Kwang-Jae;Jung, Sung-Ho;Kim, Young-Hwee;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.927-930
    • /
    • 2006
  • Hybrid procedure was performed for a thirteen-day-old girl with a functionally single ventricle, who weighed 2.2 kg and had been prematurely born at $32^{+5}$ weeks of gestation. She underwent bilateral pulmonary artery banding using 3.5 mm Gore-Tex graft, ductal stenting using balloon expandable stent, and reverse Blalock-Taussig shunt with 3.5 mm Gore-Tex vascular graft. After discharge, she was followed up for 4 months, and underwent 2nd stage operation(extensive arch reconstruction with Damus-Kaye-Stansel anastomosis, atrial septectomy, bilateral pulmonary artery angioplasty, bidirectional cavopulmonary shunt). She has been followed up for 4 months after the 2nd operation with an excellent clinical condition.

Flow and Heat Transfer Characteristics of a Multi-Tube Inserted Impinging Jet (노즐출구에 삽입된 다중관에 의한 충돌제트의 유동 및 열전달 특성)

  • Hwang, Sang-Dong;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.135-145
    • /
    • 2004
  • An experimental study is conducted to investigate the flow and heat transfer characteristics of a multi-tube inserted impinging jet. Four different multi-tube devices are tested for various nozzle-to-plate distance. Flow visualization by smoke-wire method and velocity measurements using a hot-wire anemometer are applied to analyze the flow characteristics of the multi-tube insert impinging jet. The local heat transfer coefficients of the multi-tube inserted impinging jet on the impingement surface are measured and the results are compared to those of the conventional jet. In multi-tube inserted system the multi-tube length plays an important role in the flow and heat transfer characteristics of the jet flow. With multi-tube insert of I3d4 and I6d4 which has relatively longer tube length than the multi-tube-exit of I3d1 and I6d1, the flow maintains its increased velocity far downstream due to interaction between adjacent flows. For the small H/D of 4, the local heat transfer coefficients of multi-tube inserted impinging jet are much higher than those of the conventional jet because the flow has higher velocity and turbulent intensity by the use of the multi-tube device. At large gap distance of H/D=12, also higher heat transfer rates are obtained by installing multi-tube insert except multi-tube insert of I3d1.

Acoustic Characteristics of Mufflers with an Extended Inlet and Outlet (입출구가 연장된 동심형 소음기의 음향해석)

  • 이준신
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.503-509
    • /
    • 2002
  • Cylindrical chamber silencers with an extended inlet and outlet are extensively used in many application fields to reduce the propagated noise in ducts. The basic attenuation effectiveness in the low frequency region can be explained by the reactive wave action inside the expansion chamber associated with the geometric configurations of the inlet and outlet locations, and the area expansion of the jacket. In this study. an acoustic analysis is carried out for a concentric extended pipe inserted into a simple expansion chamber. An algebraic equation is derived by using the eigenfunction expansion and orthogonality principle in which the acoustic pressures and particle velocities defined on each subdivided surface are expressed by the separable coordinates. By using the proposed analytical method, transmission losses are predicted for several configurations of the concentric extended systems and they agree very well with experimental results.

Development of Electronic Limit Switch for the Drive Unit of Incore Detector System Application (노내 핵계측 계통 구동기기의 전자식 한계스위치 개발)

  • 박종범;양승권;이상효
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.1-7
    • /
    • 2000
  • In this paper, we study a cause of malfunction of switch to control drive motor in DFMS(Digital Flux Mapping System) which can measure incore neutron flux of the nuclear plant, and develope a method to solve this problem. DFMS has the type of generating contact signal by mechanical switch lever, which is operated whenever thimble detector inserted or withdrawed through thimble Guide Tube. However the characteristics of the lever tend to be changed by mechanical degrade or bad environment and the lever finally generates errotic contact signal. Therefore we installed electric coil ass'yin the outside of Guide Tube instead of mechanical switch assy's. In addition we applied resonance effect to control circuit and installed condenser in the input of power supply to protect noise and interference. After completion of this improvement, we tested this improved device repetitively under the various conditions. In conclusion, we identified the generation of the desired contact signal and the prevention of detector failure through plant surveillance test during normal plant operation.

  • PDF