A Study on the Thermal Crack Control of the In-Ground LNG Storage Tank as Super Massive Structures (지하식 LNG 저장탱크 구조물의 온도균열 제어에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.773-780
    • /
    • 2011
  • In this study, thermal stress analysis are carried out considering material properties, curing condition, ambient temperature, and casting date of the mass concrete placed in bottom slab and side wall of the in-ground type LNG tank as a super massive structure. Also, based on the numerical results, cracking possibility is predicted and counter measures to prevent the cracking are proposed. For the tasks, two optimum mix proportions were selected. From the results of the thermal stress analysis, the through crack index of 1.2 was satisfied for separately caste concrete lots except for the bottom slab caste in 2 separate sequences. For the double caste bottom slab, it is necessary introduce counter measures such as pre-cooling prior to the site construction. Also, another crack preventive measure is to lower the initial casting temperature by $25^{\circ}C$ or less to satisfy 1.2 through crack index criterion. In the $1^{st}$ and $2^{nd}$ caste bottom slab, the surface crack index was over 1.2. Therefore, the surface cracks can be controlled by implementing the curing conditions proposed in this study. Since the side wall's surface crack index was over 1.0, it is safe to assume that the counter preventive measures can control width and number of cracks.

Analysis of Fiber Damage data Due to Physical and Chemical Causes (물리적, 화학적 원인에 의한 섬유 손상 데이터 분석)

  • Ji-Young, Seo;You, Jae-Doo;Dong-Min, Lee;Cho-Won, Park;Young-Wook, Woon
    • Journal of Industrial Convergence
    • /
    • v.21 no.2
    • /
    • pp.93-101
    • /
    • 2023
  • In this study, the physical and chemical fiber damage caused by knives, scissors, and chemicals was analyzed and used as technical data to determine the cause of the damage. Using 4 types of knives, 5 types of scissors and 4 types of chemicals(Sulfuric Acid, Hydrochloric Acid, Sodium Hydroxide, Potassium Hydroxide) physical and chemical to Cotton, Wool, Polyester, Rayon, T/C (Polyester 50%, Cotton 50%), T/W (Polyester 50%, Wool 50%) Damages were created and analyzed for damage caused by tools and chemicals. For penetrating damage caused by knives and scissors, 'V' type damage was generally seen when the blade part was penetrated, 'T', 'ㅁ', ''C' type damage was found, and in the case of scissors, 'Y' ' This type of damage was common. Fiber damage caused by chemicals showed various damage such as remanent trace, corrosion, degraded, contracting, and color changes. Physical damage of fibers showed differences in characteristics according to the shape characteristics of tools, and chemical damage showed differences in characteristics according to chemicals and types of fibers.

A study on new development of Power Cable for countermeasuring of IEC801-4 (EFT IEC801-4 대책용 Power Cable 개발에 관한 연구)

  • 배대환
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1995.04a
    • /
    • pp.109-116
    • /
    • 1995
  • 프로세서 제어기기에서 오동작의 주요원인은 EFT로 국제전기기술위원회 (IEC)는 EFT에 대한 내성을 평가하기 위해 의사적인 신호를 규정하고 프로세서 제어기기의 내성을 시험하도록 권고하고 있다 본 논문에서는 IEC에서 규정한 의사 EFT신호를 Frequency domain에서 분석하고 이에 대한 대책용 부품개발에 대한 연구를 수행하였다 대책용 부품의 구성은 전원코드의 입력측에 관통형 컨덴서를 Cy 형태로 취부하고 전선자체에는 CM성분의 임피던스를 높이기 위해 고투자율 재료를 전선의 2차피복에 혼합하거나 감는 구조로 되어있다 그리고 전선자체에 CM성분의 임피던스를 높이는 고토자율 재료 대신에 Permalloy를 취부하여 비교하였다 측정 결과 개발된 전원코드는 EFT신호에 대해 넓은 주파수 대역에 걸쳐 매우 우수한 감쇠특성을 가지는 것이 확인되었다 특히 컴퓨터를 피즉정물로 하여 즉청한 dynamic 특성은 3.6Kv까지 견디는 우수한 특성을 나타내었다. 고안된 전원 케이블의 응용범위는 산업용 설비외에도 군용기기 의료기기등의 정상적인 동작확보에 사용될 수 있을 것이다 뿐만 아니라 사용방버에 따라 전원성을 통해 방사되는 EMI중 대책이 어려운 60MH이상 수GHz 대역의 발생전자파 대책에 좋은 특성을 가질 것으로 판단되면며 부품의 선택방법에 따라 EFT의에 IEC801-2,3,5,6, 모든 내성시험 항목에 효과가 기대된다.

  • PDF

Characteristics of Insertion Loss of Transmission Line with Different Line Length Crossing a Rectangular Aperture in a Backplane (백 플레인의 개구를 통과하는 길이가 다른 전송 선로의 삽입 손실 특성)

  • Jung, Sung-Woo;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.237-243
    • /
    • 2008
  • This paper presents the backplane effects for two-wire transmission line with different line length crossing the rectangular aperture in an infinite ground backplane. The FDTD method is used to determine the characteristics of the backplane insertion loss and return loss of the transmission line in accordance with the transmission line spacing and additional wire lengths. The results show that the insertion gain is obtained for the narrow spacing of the transmission line and the insertion loss is appeared for the transmission line with the additional wire The measurements of return loss are performed to verify the theoretical analysis.

Analysis of Hull-Induced Flow Noise Characteristics for Wave-Piercing Hull forms (파랑관통형 선형의 선체유기 유동소음특성에 관한 연구)

  • Choi, Woen-Sug;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung;Seo, Jeong-Hwa;Rhee, Shin-Hyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.619-627
    • /
    • 2018
  • As ships become faster, larger and are required to meet higher standards, the importance of flow noise is highlighted. However, unlike in the aeroacoustics field for airplanes and trains (where flow noise is considered in design), acoustics are not considered in the marine field. In this study, analysis procedures for hull-induced flow noise are established to investigate the flow noise characteristics of a wave-piercing hull form that can negate the effect of wave-breaking. The principal mechanisms behind hull-induced flow noise are fluid-structure interactions between complex flows underneath the turbulent boundary layer and the hull. Noise induced by the turbulent boundary layer was calculated using wall pressure fluctuation and energy flow analysis methods. The results obtained show that noise characteristics can be distinguished by frequency range and hull region. Also, the low-frequency range is affected by hull forms such that it is correlated with ship speed.

Crash survival analysis and tests for the capsule of voyage data recorder (항해자료기록기 캡슐의 극한환경시험 해석 및 시험에 관한 연구)

  • Lee, Byoung-Ho;Lee, Sock-Kyu;Park, Suk-Hwan;Choi, Ji-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.32-39
    • /
    • 2011
  • The purpose of VDR capsule is to maintain a stored information securely and retrievably in the extreme environment like voyage incident. This study shows the modellings, the analyses and the experiments of the survivability test of penetration, high and low temperature fire. The capsule housing is used to protect capsule against penetration and the influences of its thickness are studied by the modelling and analysis of penetration using LS-DYNA. The phase change material and thermal insulation material are used to protect capsule against high and low temperature fire test. The thermal characteristics of various volume ratios of phase change material to thermal insulation material were conducted. Also the tests were conducted to confirm the structural and thermal reliability.

Seismic Performance of Built-up Concrete Filled Square Composite Column-to beam Connection with Through Diaphragm (관통형 다이아프램을 갖는 조립형 콘크리트 충전 각형 합성기둥-보 접합부의 내진성능)

  • Kim, Sun Hee;Yom, Kyong Soo;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.431-439
    • /
    • 2014
  • Concrete filled tubular columns are widely used because the mutual reaction between the concrete and the tube improves strength and ductility of the columns. In an attempt to secure efficient use of members, built-up square columns featuring large width-thickness ratio and the use of thin steel plates are suggested in this study. In order to evaluate the structural characteristics and seismic performance of the column-to-beam connections of the new shape columns, cyclic load test of T-shaped column-to-beam connections was conducted with variables of diaphragms and concrete-filling. Moment-rotational angle relationship, dissipated energy and failure behavior were compared to evaluate stress transfer mechanism of the new shape built-up square column-to-beam connections associated with the variables.

Guided Wave Mode Selection and Flaw Detection for Long Range Inspection of Polyethylene Coated Steel Gas Pipes (폴리에틸렌 코팅 가스배관의 광범위탐상을 위한 유도초음파 모드 선정 및 결함 검출)

  • Song, Sung-Jin;Park, Joon-Soo;Shin, Hyeon-Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.406-414
    • /
    • 2001
  • Ultrasonic guided waves were explored to apply them to the long range inspection of polyethylene coated steel gas pipes. The steel pipes have such dimensions as 190.7mm inside diameter and 5.3mm thickness. The outside surface of the pipe is coated by a polyethylene layer of $1.9{\pm}0.5mm$ thickness. Non-axisymmetric guided waves were excited on the outside surface of the polyethylene coated pipe by using a 0.5MHz transducer with a variable angle shoe. Frequency and phase velocity tuning was used to find optimum guided wave modes for the inspection. The dispersive characteristics of the modes were analyzed in time-frequency representation obtained by short time Fourier transforms. Sample results were presented for artificial defects such as wall thinning and hole.

  • PDF

Deformation behavior of tunnels crossing weak zone during excavation - numerical investigation (연약대를 통과하는 터널의 시공중 변위거동 - 수치해석 연구)

  • Yoo, Chungsik;Park, Jung-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.4
    • /
    • pp.373-386
    • /
    • 2014
  • This paper concerns the deformation behavior of tunnels crossing weak zone during excavation. A three dimensional finite element model was adopted in order to conduct a parametric study on the orientation of weaj zone in terms of strike and dip angle relative to the tunnel longitudinal axis. The results of the analyses were then analyzed so that the tunnel displacements in terms of the ratios between the crown settlement and springline displacement can be related to the orientation of the weak zone. The results indicate that the displacement ratios between the tunnel crown and springline tend to quantitatively change when a weak zone exists near or ahead of the tunnel suggesting that the displacement ratios can be effectively used to predict the weak zone during tunnelling. Practical implications of the findings are discussed.

Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment II: Fire Resistance Test for Piece Material and Insulation Types (A60급 구획 적용 격벽 관통용 관의 열전달 특성 II: 관 재질 및 단열재 종류에 따른 방화시험)

  • Park, Woo-Chang;Song, Chang Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.340-349
    • /
    • 2019
  • In the case of a fire accident on a ship or an offshore plant, the design of the bulkhead penetration piece must be verified via a fire test procedure (FTP), as specified by the Maritime Safety Committee (MSC). The purpose of this study is to verify both the numerical analysis results and the design specifications for penetration pieces that could be applied to the A60 class bulkhead division. In this study, the FTP was carried out in accordance with the test procedure prescribed in the MSC regulation. In order to review the fire resistance performance according to the material type, bulkhead penetration pieces for the FTP were made from brass, carbon steel for machine structures (S45C), and austenite stainless steel (SUS316). In addition, spray-type insulation and mechanical fastener-type insulation were applied to investigate the fire resistance performance according to the type of insulation. To verify the heat transfer numerical analysis results for the A60 class bulkhead penetrating piece from this test study, the design specifications of the penetrating piece material and the insulation type applicable to a ship and an offshore plant were identified.