• Title/Summary/Keyword: 관측점

Search Result 1,256, Processing Time 0.033 seconds

Oceanic Skin-Bulk Temperature Difference through the Comparison of Satellite-Observed Sea Surface Temperature and In-Situ Measurements (인공위성관측 해수면온도와 현장관측 수온의 비교를 통해 본 해양 피층-표층 수온의 차이)

  • Park, Kyung-Ae;Sakaida, Futoki;Kawamura, Hiroshi
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.273-287
    • /
    • 2008
  • Characteristics of skin-bulk sea surface temperature (SST) differences in the Northeast Asia seas were analyzed by utilizing 845 collocated matchup data between NOAA/AVHRR data and oceanic in-situ temperature measurements for selected months from 1994 to 2003. In order to understand diurnal variation of SST within a few meters of the upper ocean, the matchup database were classified into four categories according to day-night and drifter-shipboard measurements. Temperature measurements from daytime drifters showed a good agreement with satellite MCSST (Multi-Channel Sea Surface Temperature) with an RMS error of about $0.56^{\circ}C$. Poor accuracy of SST with an rrns error of $1.12^{\circ}C$ was found in the case of daytime shipboard CTD (Conductivity, Temperature, Depth) measurements. SST differences between MCSST and in-situ measurements are caused by various errors coming from atmospheric moist effect, coastal effect, and others. Most of the remarkable errors were resulted from the diurnal variation of vertical temperature structure within a few meters as well as in-situ oceanic temperatures at different depth, about 20 cm for a satellite-tracked drifting buoy and a few meters for shipboard CTD or moored buoy. This study suggests that satellite-derived SST shows significant errors of about ${\pm}3^{\circ}C$ in some cases and therefore it should be carefully used for one's purpose on the base of in-depth understanding of skin-bulk SST difference and vertical temperature structure in regional sea.

Accuracy Analysis on Geodetic Network in Jeju area using GPS (GPS에 의한 제주지역의 측지기준망 정확도 분석)

  • Kang, Sang-Gu;Jung, Young-Dong;Yang, Young-Bo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.14 no.1 s.35
    • /
    • pp.65-74
    • /
    • 2006
  • A rapidly developed satellite technology is used in comprehensive fields such as spatial data aquisition and applications. Especially a GPS positioning is expected to reinvigorate at the national reference system changes to ITRF(International Terrain Reference Frame). Currently the National Geographic Information Institute(NGII) issues a triangulation point coordinate by separating old and new coordinates and in the year of 2007 it will be scheduled to be changed ITRF. The triangulation point coordinate in Cheju area causes some problems due to the difference original observation and re-observation. Thus in this study a GPS observation is conducted after re-organizing geodetic network based on 1st and 2nd order triangulation in order to check the current triangulation points in Cheju area. After the GPS observation data analysis, stable points were extracted, proposed a geodetic network and its application.

  • PDF

Deformation Monitoring of a Structure Using Kinematic GPS Surveying Technology (Kinematic GPS 측량기법에 의한 구조물의 변형 모니터링)

  • 이진덕
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.1
    • /
    • pp.27-40
    • /
    • 1998
  • This paper addresses the suitability of GPS positioning technology to monitoring deformation and movement of structures. The first part of the study is an empirical quantitative study of the repeatability of GPS observations and the second part is a performance evaluation of kinematic GPS, which requires only a few minutes per a point, for monitoring deformation of an engineering structure. On the test network for monitoring of a earth am, four observations have been conducted repeatedly on different seasons and water levels. The reference network was observed in static mode, and monitoring points were observed respectively in rapid-static mode as well as in kinematic mode in each epoch and then the results were compared with those obtained by conventional surveying techniques. The repeatability of baseline vectors to better than average 7 mm in three dimensions was achieved in base line observations between reference points and also the unclosure of reference networks showed the range of 4 ppm to 27 ppm. Compared with conventional surveying techniques, the kinematic approach showed the differences of 3∼4 m in slope distances which were observed from reference points to monitoring points, and showed the differences of 4∼8 m in height. It was ascertained that the kinematic GPS technology provides an efficient alternative to deformation monitoring by conventional means which are capable of detecting movements in the order of 5 mm.

  • PDF

A Dataset from a Test-bed to Develop Soil Moisture Estimation Technology for Upland Fields (농경지 토양수분 추정 기술 개발을 위한 테스트 베드 데이터 세트)

  • Kang, Minseok;Cho, Sungsik;Kim, Jongho;Sohn, Seung-Won;Choi, Sung-Won;Park, Juhan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2020
  • In this data paper, we share the dataset obtained during 2019 from the test-bed to develop soil moisture estimation technology for upland fields, which was built in Seosan and Taean, South Korea on May 3. T his dataset includes various eco-hydro-meteorological variables such as soil moisture, evapotranspiration, precipitation, radiation, temperature, humidity, and vegetation indices from the test-bed nearby the Automated Agricultural Observing System (AAOS) in Seosan operated by the Korea Meteorological Administration. T here are three remarkable points of the dataset: (1) It can be utilized to develop and evaluate spatial scaling technology of soil moisture because the areal measurement with wide spatial representativeness using a COSMIC-ray neutron sensor as well as the point measurement using frequency/time domain reflectometry (FDR/TDR) sensors were conducted simultaneously, (2) it can be used to enhance understanding of how soil moisture and crop growth interact with each other because crop growth was also monitored using the Smart Surface Sensing System (4S), and (3) it is possible to evaluate the surface water balance by measuring evapotranspiration using an eddy covariance system.

Development of a CPInterface (COMSOL-PyLith Interface) for Finite Source Inversion using the Physics-based Green's Function Matrix (물리 기반 유한 단층 미끌림 역산을 위한 CPInterface (COMSOL-PyLith Interface) 개발)

  • Minsu Kim;Byung-Dal So
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.4
    • /
    • pp.268-274
    • /
    • 2023
  • Finite source inversion is performed with a Green's function matrix and geodetic coseismic displacement. Conventionally, the Green's function matrix is constructed using the Okada model (Okada, 1985). However, for more realistic earthquake simulations, recent research has widely adopted the physics-based model, which can consider various material properties such as elasticity, viscoelasticity, and elastoplasticity. We used the physics-based software PyLith, which is suitable for earthquake modeling. However, the PyLith does not provide a mesh generator, which makes it difficult to perform finite source inversions that require numerous subfaults and observation points within the model. Therefore, in this study, we developed CPInterface (COMSOL-PyLith Interface) to improve the convenience of finite source inversion by combining the processes of creating a numerical model including sub-faults and observation points, simulating earthquake modeling, and constructing a Green's function matrix. CPInterface combines the grid generator of COMSOL with PyLith to generate the Green's function matrix automatically. CPInterface controls model and fault information with simple parameters. In addition, elastic subsurface anomalies and GPS observations can be placed flexibly in the model. CPInterface is expected to enhance the accessibility of physics-based finite source inversions by automatically generating the Green's function matrix.

Intercomparison of Middle and Low Tropospheric Temperature from Satellite with ECMWF Reanalyses; Temporal and Spatial Variability (위성관측에서 유도된 중간 및 하부 대류권 온도와 ECMWF 재분석 결과 사이의 상호 비교; 시.공간 변동)

  • 이은주;유정문
    • Proceedings of the KSRS Conference
    • /
    • 2000.04a
    • /
    • pp.43-48
    • /
    • 2000
  • 중간 및 하부 대규권의 열적 상태에 대한 결과들의 상대적인 정확성을 평가하기 위하여 대기대순환 모델의 재분석(1980-93년) 그리고 세 종류의 위성관측 자료들(1980-97년)을 태평양, 한반도 부근에 대한 시.공간 분석으로 상호 비교하였다. 중간 대류권 온도를 반영하는 위성자료는 본 연구에서 유도된 Microwave Sounding Unit (MSU) 채널2 직하점 밝기온도(MSU2)와 Spencer and Christy(1992a)가 전체 주사자료를 사용하여 유도된 채널2 밝기 온도(SC2)이고, 하부 대류권 온도를 반영하는 위성자료는 Spencer and Christy(1992a)가 유도한 것이다(SC2R). 또한, 모델 자료는 ECMWF 재분석 온도이며, 위성관측 자료와의 비교를 위하여 재구성되었다. 한편, 각 위.경도 격자에서 위성관측과 모델 재분석의 월평균 값들의 상관도 전구적으로 조사하였다. 세 종류의 관측 자료들 간의 상관은 중.고위도에서 높았으나(r$\geq$0.9), 저위도 그리고 대류가 활발한 열대 서태평양 및 콩고강 부근에서 낮았다(r~0.65). 특히 SC2R에 대한 다른 자료의 상관이 상대적으로 낮았다. 이는 하부 대류권의 열적 상태를 반영하는 SC2R이 수적 및 지표방출의 영향으로 잡음을 크게 내포하기 때문인 것으로 추정되었다. 관측들과 모델 온도에 대한 월평균과 아노말리 값의 분석에서 시.공간 변동은 대체로 유사하였다. 관측 및 모델 자료는 열대 태평양 이외의 지역에 대한 월평균 값 모드1에서 연주기를 보였으나, 열대 태평양의 경우 모드2에서 보였다. 열대 태평양의 MSU2 모드1은 Walker 순환에 의한 동.서 대비를 보인 반면, 다른 위성관측과 모델 자료에서는 이러한 형태가 현저하지 않았다. 이 지역의 아노말리 값 모드2에서 위성관측들은 엘리뇨 기간에 적도를 중심으로 열대 동태평양 부근에서 아령모양의 대칭 형태를 보였으나 모델 결과에서는 이러한 특징이 약하였다. 관측과 모델 모두는 열대 태평양에 대한 아노말리 값의 모드 1,2에서 엘니뇨와 라니냐에 의한 경년변동을 뚜렷하게 보였다.

  • PDF

Effects analysis of multipath in the Static GPS (정적 GPS 측위에서 멀티패스 영향 분석)

  • 박운용;장상규;이현우;김진수
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.87-90
    • /
    • 2003
  • 정밀한 위치결정에 사용되는 GPS는 초기 군사목적을 벗어나 자동차, 선박, 비행기 등의 항법은 물론 측량분야, 지각 및 구조물의 변위 감시, 우주, 통신, 국방 분야 등 매우 광범위한 분야에서 활용되고 있으며, 그 이용도가 급속히 증가하는 추세이다. 그러나 GPS 관측값은 부정오차와 정오차 등 많은 오차를 포함하고 있기 때문에 이를 소거하거나 최소화하여야 한다. GPS 오차는 크게 위성궤도나 위성시간 오차등 위성에 관련된 오차, 수신기 잡음이나 다중경로 등 수신기 관련 오차, 그리고 대류권이나 전리층에 의한 전파 오차로 구분할 수 있다. 이들 오차들은 대부분 차분방법과 수학적 알고리즘에 의해 소거되거나 최소화되지만, 다중경로와 수신기 잡음은 소거하거나 축소할 수 없다. 다중경로는 관측당시의 수신기 주변환경에 따라 바뀌기 때문에 수학적으로 소거할 수 없으며, 수신기 잡음은 수신기 내부의 노이즈로 인하여 발생하기 때문에 소거하기가 상당히 어렵다. 본 연구에서는 다중경로에 의한 GPS 기선변화를 알아보기 위해서 여러 조건하에서 정적 GPS 측량을 실시하였다. 먼저 정확한 좌표를 알고 있는 한 점에 GPS를 설치하고 다른 두 대의 GPS을 임의 점에 설치하였고, 이들 두 GPS 중에 하나의 수신기에 다중경로 환경을 설정하였다 정적 GPS 관측시 기선에 어떠한 변화가 오는 파악하기 위해서 기선처리와 망조정을 통해 기선길이와 좌표값을 산출하였다. 이러한 다중경로 실험은 구조물 모니터링 등 mm 정확도를 요구하는 GPS 측량에 유용하게 사용될 수 있을 것이다.

  • PDF

A Study on Spatio-Temporal Analysis Using AWS Data in Seoul (AWS자료를 활용한 서울지역 강수량의 시공간적 특성분석)

  • Moon, Young-Il;Son, Chan-Young;Kwon, Hyun-Han;Moon, Jang-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.374-374
    • /
    • 2011
  • 이상기후 및 기상변동성의 증가로 극치강수량의 시공간적인 변동성이 크게 증가되고 있다. 서울시에 2010년 9월 21일에 내린 폭우사례와 같이 공간적으로 변동성이 큰 형태의 강우가 발생하는 사례가 빈번해지고 있다. 이러한 점에서 과거 강우자료로부터 시공간적인 추출하고 이를 범주화하는 연구는 방재관점에서 매우 중요한 정보로 활용할 수 있다. 이러한 강수의 시공간적 특성을 평가하기 위해서는 상대적으로 조밀한 강수관측망이 요구된다. 서울시의 경우 기상청에서 운영하는 관측소이외에도 서울시에서 운영하는 강수관측지점이 다수 존재한다. 이러한 점에서 착안하여 본 연구에서는 서울시에 운영하고 있는 26개의 AWS자료를 활용하여 시공간적인 강수변동성을 추출하고 평가하는데 목적이 있다. 본 연구에서는 시간강수량 및 일강수량을 대상으로 연구를 진행하였으며 공간상관성분석, 지체상관분석을 실시하여 서울시 강수량 특성을 정량화 하였다. 강수의 공간적인 변동성은 2002년부터 2009년까지 26개 강수지점으로부터 추정된 150mm이상 최대강우사상 10개와 일강수량이 20mm미만이 10개의 강우사상의 지점별 표준편차를 통해서 대표적으로 분석하였다. 일강수량을 대상으로 공간적인 특성을 평가해본 결과 강수량의 크기가 클수록 서울시 강수장의 특성은 매우 불균질한 특성을 보여주고 있으며 반대로 강수량이 작은 경우 상대적으로 균질한 특성을 보여주고 있다.

  • PDF

A STUDY ON THE GROSS ERROR DETECTION AND ELIMINATION IN BUNDLE BLOCK ADJUSTMENT (번들블럭조정에 있어서 과대오차 탐색 및 제거에 관한 연구)

  • 유복모;조기성;신성웅
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.9 no.1
    • /
    • pp.47-54
    • /
    • 1991
  • In this study, the accuracy of three dimensional location was improved by self calibration bundle method with additional parameter, which is to correct systematic error through detection and elimination of the gross error from updated reference variance for observation values in photogram-metry. In this study, with the result of comparing accuracy of each method, correcting systematic error is more effective after gross error detection and when observation values are contained more than two gross error the point with maximum correlation value is detected by masking effect of least square adjustment.

  • PDF

Speed Sensorless Control for the trapezoidal BLDC Motor Using an Instantaneous Speed Observer (순시 속도 관측기를 사용한 사다리꼴형 브러시리스 직류 전동기의 속도 센서리스 제어)

  • Lee, Dong-Hoon;Lee, Kyo-Beum;Song, Joong-Ho;Choy, Ick;Yoo, Bum-Jae;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1117-1119
    • /
    • 2003
  • 기존의 사다리꼴형 브러시리스 직류 전동기(BLDCM)의 센서리스 제어는 전류전환 시점을 알기 위하여 홀 센서 대신 단자 전압과 중성점 전압을 이용한다. 하지만, 속도 제어를 위해서는 엔코더나 레졸바와 같은 센서를 사용해야한다. 2극기 BLDC 모터의 경우 단자전압을 이용한 위치정보는 모터 한 회전 당 12번의 신호가 출력된다. 엔코더 혹은 레졸바를 제거하고, 이 신호를 이용하여 속도 정보를 만들 경우, 속도를 만들기 위한 위치 정보의 펄스 간격이 넓게 되어 순시 속도를 만들지 못하게 된다. 이로 인하여 실제 속도의 변화를 민감하게 추정하지 못하게 된다. 따라서 이렇게 만들어진 속도 정보는 실제 시스템에서 사용할 수 없게 된다. 이러한 문제를 해결하려고 본 논문에서는 순시 속도 관측기를 사용한다 단자전압과 중성점 전압에 의한 위치정보를 가지고 순시 속도 관측기를 속도 제어 주기보다 빠르게 갱신함으로써 순시 속도를 예측한다. 또한 이 순시 속도는 속도 제어기로 피드백 되어 속도 센서리스를 실현한다. 이에 대한 타당성은 시뮬레이션을 통해 검증한다.

  • PDF